XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

Similar documents
XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XACA871 pendant control station XAC-A - 8 pushbuttons

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

XACA871 pendant control station XAC-A - 8 pushbuttons

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

OsiSense XMLP Pressure Transmitters for Industrial Applications. Catalog

Pressure sensors - Nautilus

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

K50H004UP cam changeover switch - 4-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Type A-10 General Purpose Pressure Transmitters

OEM Pressure Transmitters

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

XMLRppp Electronic pressure switch

Electronic pressure switch with integrated analogue output

Electronic flow switch With display, for liquid media Model FSD-3

XACA871 pendant control station XAC-A - 8 pushbuttons

Type A-10 General Purpose Pressure Transmitter

Electronic Pressure Switch EDS 3000

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Electronic Pressure Switches

K50F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting

XACA871 pendant control station XAC-A - 8 pushbuttons

Surface mounting, flush mounting, and DIN track mounting

Temperature switch. Switching output 2 transistors PNP Logger Ring buffer: 3518 data points Sampling time: s, Off (0)

Electronic Pressure Switches

Electronic pressure switch with two switching outputs

Proximity, Photoelectric, and Ultrasonic Sensors, Limit Switches, Pressure Sensors, Machine Safety, Encoders, RFID, and Machine Cabling

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Model Pressure range ON/OFF output Linear output

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

Differential pressure sensor

BMI0703P17F servo motor BMI 3-phase - keyed IP54 multiturn p/t x 4096 t - brake

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Differential Pressure Sensors

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

M5200 Industrial Pressure Transducer

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

BMH1001P17F2A servo motor BMH Nm rpm - keyed shaft - with brake - IP54

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

VW3A4552 line/motor choke - 4 mh - 10 A - 3 phases - 65 W - for variable speed drive

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Pressure Sensors. for liquid and gaseous media

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

PRODUCT SPECIFICATION. Foot Switches. Series.

Electronic pressure sensors OsiSense XM For control circuits

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Differential Pressure Sensors

Model Number Structure

Model Pressure range ON/OFF output Linear output

Differential Pressure Sensor

Pressure Transmitter JUMO dtrans p30 Type

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Industrial Power Supplies

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Pressure transmitter for industrial applications Type MBS 4500

Pressure transmitter for industrial applications Type MBS 4510

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

BMH0701P07F2A servo motor BMH Nm rpm - untapped shaft - with brake - IP54

Beck. The differential pressure transmitter for air with IP65

JUMO MIDAS S05 Pressure transmitter Type

Solid State Relays, 3-phase

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

OEM Pressure Transmitters

FPT Applications. Features

EB100 High Accuracy Miniature Pressure Transducer

Transcription:

Characteristics Pressure sensors XMLR 400bar - G 1/4-24VDC - 0..10 V - NPN - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short name Pressure sensor size Maximum permissible accidental pressure Destruction pressure Controlled fluid Sep 11, 2018 OsiSense XM Electronic pressure sensors Pressure transmitter Pressure transmitter with 1 switching output XMLR 400 bar 5800 psi 1200 bar 17400 psi 120 MPa 2400 bar 34800 psi 240 MPa Fresh water (0...80 C) Air (-20...80 C) Hydraulic oil (-20...80 C) Refrigeration fluid (-20...80 C) Fluid connection type G 1/4 (female) conforming to DIN 3852-Y [Us] rated supply voltage Complementary Current consumption Electrical connection Analogue output function Type of output signal Analogue output function Discrete output type Maximum switching current Contacts type and composition Scale type Voltage drop Adjustable range of switching point on rising pressure 24 V DC SELV, voltage limits: 17...33 V <= 50 ma 4 pins M12 male connector 0...10 V Analogue + discrete 0...10 V Solid state NPN, NO/NC programmable 250 ma NO/NC programmable Fixed differential <= 2 V 32...400 bar 464...5800 psi 3.2...40 MPa 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Adjustable range of switching point on falling pressure Minimum differential travel Materials in contact with fluid Front material Housing material Operating position Protection type Response time on output Time delay range Display type Local signalling Display response time type Delay first up Accuracy Linearity error Hysteresis Measurement accuracy Repeat accuracy Drift of the sensitivity Drift of the zero point Display accuracy Mechanical durability Depth Height Width Product weight [Uimp] rated impulse withstand voltage Electromagnetic compatibility 20...388 bar 290...5626 psi 2...38.8 MPa 12 bar 174 psi 1.2 MPa 316L stainless steel Polyester Polyacrylamide 316L stainless steel Any position, but disposals can falsified the measurement in case of upside down mounting Overload protection Overvoltage protection Reverse polarity Short-circuit protection <= 10 ms for analog output <= 5 ms for discrete output 0...50 s in steps of 1 second 4 digits 7 segments 1 LED yellow for light ON when switch is actuated Fast 50 ms Normal 200 ms Slow 600 ms <= 300 ms <= 1 % of the measuring range <= 0.5 % of the measuring range <= 0.2 % of the measuring range <= 0.6 % of the measuring range <= 0.2 % of the measuring range +/- 0.03 % of measuring range/ C +/- 0.1 % of measuring range/ C <= 1 % of the measuring range >= 10000000 cycles 42 mm 88 mm 41 mm 0.186 kg 0.5 kv DC Electrostatic discharge immunity test - test level 8 kv air, 4 kv contact conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields - test level 10 V/m (80...2000 MHz) conforming to EN/IEC 61000-4-3 Electrical fast transient/burst immunity test - test level 2 kv conforming to EN/IEC 61000-4-4 Surge immunity test - test level 1 kv conforming to EN/IEC 61000-4-5 Immunity to conducted RF disturbances - test level 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 Environment Marking Product certifications CE CULus EAC Standards UL 61010-1 EN/IEC 61326-2-3 Ambient air temperature for operation -20...80 C Ambient air temperature for storage -40...80 C IP degree of protection IP65 conforming to EN/IEC 60529 IP67 conforming to EN/IEC 60529 Vibration resistance 20 gn (f = 10...2000 Hz) conforming to EN/IEC 60068-2-6 Shock resistance 50 gn conforming to EN/IEC 60068-2-27 2

Offer Sustainability RoHS (date code: YYWW) REACh Compliant - since 1351 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold 3

Dimensions Drawings Dimensions (1) Fluid entry: G 1/4 A female 4

Connections and Schema Connections and Schema Connector Wiring (1) I Out or V Out 5

Performance Curves Analogue Output Description Analogue Output Signal X : Pressure Y : Analogue output signal (1) An offset of +/-5% of nominal pressure can be compensated (with Cof Configuration menu. Cof: Offset Compensation) (2) The Analogue curve can be adjusted from -25% to +25% of nominal pressure (with AEP Configuration menu. AEP: analogue end point). 6

Performance Curves Switching Output Description. Hysteresis Mode The hysteresis switching mode is typically used for the pumping and/or emptying applications. X : Time Y : Pressure (1) Output NP : Nominal Pressure SP : Set point (adjustable from 8 % to 100 % NP) rp : Reset point (adjustable from 5 % to 97 % NP) 7

Performance Curves Switching Output Description. Window Mode The window switching mode is typically used for the pressure regulation applications X : Time Y : Pressure (1) Output NP : Nominal pressure FH : High switching point (adjustable from 8 % to 100 % NP) FL : Low switching point (adjustable from 5 % to 97 % NP) 8

Performance Curves Switching Output Description. Time Delay The Time Delay is typically used to filter out the fast pressure transients. The output only switches after a time ds and dr adjustable from 0 to 50 seconds. X : Time Y : Pressure (1) Output SP : Set point rp : Reset point ds : Time delay on the set point dr : Time delay on the reset point 9