MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09

Similar documents
MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R6 08/17

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R8 08/18

3000 psi (207 bar) Output/ min. 115 VAC 10cc (0.61 cu. in.) 24 VDC 12cc (0.73 cu. in.) Discharge Element Output Port.

MultiPort II Lubricator

MultiPort II Lubricator

SureFire II Lubricator

CXL2 Injectors & Manifolds

FZ-A Lubricator. Electric, Oil & Grease. General. Application. Operation. Features. Adjustment of Discharge Rate R2 03/09

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - 13C MAY FORM Page. Section - Q3

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3. MAY FORM Section

Series 3000 Divider Valve Manifold

Model CHASSIS LUBE ELECTRIC GREASE PUMP Series "C"

Fill cap with inlet strainer (40 mesh) Automatic approved quick connect inlet (no strainer)

MOTOR. The electric motor. DC - direct current voltage.

Operators Manual TTN LUBRICATOR Series Progressive r#9

SureFire II Lubricator

M OTO R. The electric motor. DC - direct current voltage.

Quicklub Lubrication Systems

Modular Lube Lubrication Systems

400 psi (28 bar) PDI & INJ. 100 psi (7 bar) PDI & INJ

Your machinery deserves genuine Bijur parts.

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3

Electric grease pump series L-EGP 230VAC / 400VAC

DP33 Pump. 60:1, 3+3, Air-operated, Grease. General. Operation. Technical Data. Installation R2 08/15

Airmatic Lubricator. Pneumatic Operation, Oil. General. Application. Operation. Technical Data

DP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended)

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

Features and Benefits

Series 1000 Divider Valve Manifold

Versa II SLR Lubricator

QLS 321 SOLUTIONS. Compact and Rugged Easy to Install and Use Multiple Standard Features. Quicklub Lubrication Systems.

Operation and service manual

Grease and Oil Injectors

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

lubrication systems CME Electric pump for oil and soft grease volumetric

DUOFLEX lubrication pumps

number of outlets 1 2 lubricant output per lever movement 2 cm 3 (0.122 in 3 ) 2x1 cm 3 (2 X in 3 )

LubeSite 500 Series. Grease, Metal Base, Corrosion Resistant. General. Application. Operation. Technical Data R0 06/09

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

AX1, 2 & 3 SERVICE & SERVICE and MAINTENANCE MANUAL MAINTENANCE. for INTERLUBE MANUAL

Centro-Matic. Automated Lubrication Systems

Operators Manual Electric Barrel Pump r#0

Hand Operated Hydraulic Pumps PHP121DAH65 PHP121DA95. Engineering & Manufacturing Solutions

CLP - Cartridge Lube Pump

LubePro Series Pumps For Simple, Injector-based Automatic Lubrication Systems

Centralized & Automated Lubrication Systems. I design Quicklub and other systems to satisfy each customer s unique requirements.

Low Profile J Series Power Unit with Vane Pump

Mizer Single Pump and Starter Box

surefire PDI OPERATORS MANUAL Three Phase Models (230/480 VAC) 35027E R

THE REVOLUTIONARY P653S ELECTRIC CENTRO-MATIC PUMP

SOLUTIONS. International Solutions. FOR A Global Marketplace. In This Issue:

Product description Electric Lubrication pump Dynamis Maxx APPLICATION PRODUCT CHARACTERISTICS ADVANTAGES

QUICKLUB CENTRALIZED & AUTOMATED LUBRICATION SYSTEMS

Pumping Ratio 50:1. ( bar) Max. Output 7500 psi. Air Inlet. Material Outlet. Airmotor Bore Dia. 3 in. (76.2 mm) Stroke

Motor-driven pump unit GSJB

+\YH4(*;4 >H[LY 7YLZZ\YL )VVZ[LY :`Z[LT 0UZ[HSSH[PVU 0UZ[Y\J[PVUZ +\YH4(*

farval DUaLINE SYSTEMS Ideally suited for heavy industry Continuous duty operation Over 80 years of excellence

50:1 Grease Pump Kits

Lubemaster Pump DESCRIPTION

SUREFIRE SLR. Centralized Lubricating System. + SureFire SLR Automatic Lubricator + Resistance Fittings + Distribution Components + Accessories

SOLUTIONS. Airless Spray System. In This Issue: Airless Spray System pg. 2. Improved FlowMaster pg. 5

DM Valve LINE 1 LINE 1 LINE 2. Positive indication at every bearing. adding or subtracting points at every bearing. Has only two moving parts.

Air/Hydraulic Actuators

ELECTRIC GREASE AND OIL PUMPS ILC-MAX

FARVAL DUALINE SYSTEMS + + Ideally suited for heavy industry + + Continuous duty operation + + Over 80 years of excellence

Pump Autolub-M. Product description APPLICATION PRODUCT CHARACTERISTICS FUNCTION

DD & DM Valves. Dualine, Grease & Oil. General. Operation. Features. DM Valve. DD Valve R5 09/12

LUBRICATION PUMP UCF CENTRAL LUBRICATION

DIESEL Engine Fire Pump Controllers Features

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

FARVAL DUALINE SYSTEMS. + Ideally suited for heavy industry + Continuous duty operation + More than half a century of excellence

EZ-View. Flow Meters ISO CERTIFIED 9001

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

MODEL B ELECTRIC HYDRAULIC PUMP

Lincoln Quicklub centralized and automatic lubrication systems

G3 Electric Lubrication Pump. For Series Progressive and Injector-based Systems

OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET

Safety & Shut-off Blocks

Automatic SingleLine Greasing System

Centro-Matic Automatic Lubrication Systems FlowMaster Hydraulic Pump

HYDRAULIC STEERING MANIFOLD HM260 TABLE OF CONTENTS. 1. GENERAL INFORMATION... p TECHNICAL SPECIFICATIONS... p. 01

M SERIES Multi-Jet Cold Water Meter

TWO-LINE ELECTRIC CHANGE-OVER VALVE

Form No Parts List for: RWP55 RWP55-4 MODEL C HYDRAULIC PUMP AIR DRIVEN WITH REMOTE CONTROL GENERAL ASS'Y SIDE VIEW SECTION A-A

Automated Lubrication System

Air / Hydraulic Pump

Lubrication Systems. Section 26

Operating Instructions & Parts Manual

blocks Interconnection fuses &

Electric barrel pump EFP-1 and EFPM-2 General, Fields of application und types of systems

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

Automated Lubrication System

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

DESCRIPTION OPERATION. Product descripption SureFire Electrical Pump

Troubleshooting Bosch Proportional Valves

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#2

ASSEMBLY MANUAL. Keep With Operator s Manual

OPERATORS MANUAL Single Phase Models (24VDC, 115VAC and 230VAC) 35139E r

Transcription:

MultiPort Lubricator Electric motor-driven, Grease and Oil General The MultiPort Lubricator is a rugged, motor-driven, electric lubricator, equipped with fixed output pumping elements to discharge grease or oil over a wide operating range. Low level switches are standard on this compact unit. Up to three independent feed lines can be used with the MultiPort Lubricator. A selection of timers and controller/monitors are available to program MultiPort Lubricators. Technical Data Reservoir Capacity, 4 and 8 liter (4, 8 and 6 lb) Lubricant Grease NLGI grade (Max) Oil Up to 5000 SUS Maximum Working Pressure Grease 3600 psi (40 bar) Operating Voltage Operating Temperature Range Pumping Elements to 3 Output per rpm Motor Low Level Switch Discharge Element Output Port Oil 900 psi (80 bar) As noted below 0 F to 0 F (-8 C to 49 C) 0.6cc (0.0 cu. in.) As noted below Available on some models (normally closed) /4" NPTF Fill Connection Grease Male filler fitting, quick disconnect Materials Motor Oil Fill cap Plastic, Steel (0/440 VAC grease) IP Enclosure Rating HP Rating Voltage Amperage Grease IP-55 0.068 VDC 4 FLA 4 VDC FLA 0.08 0 VAC.83 FLA 0/440 VAC 0.63 FLA Oil IP-55 0.068 4 VDC FLA Operates at 40 rpm @ 68 F, 000 psi back pressure Operates at 3 rpm (60 Hz) @ 68 F, 000 psi back pressure 0.08 0 VAC.83 FLA 0/440 VAC 0.63 FLA

Start Up Instructions.. 3. 4. The motor must be securely and adequately grounded. The power voltage must be correct. The motor rotating direction must be same as the arrow on motor end housing. The grease/oil must be clean. Fill the reservoir through fill cap and screen (oil). Fill the reservoir through the grease fill fitting (grease). Troubleshooting Symptom Possible Cause Remedy Pump does not deliver lubricant. Reservoir is empty. Fill up lubricant and run to charge elements. Electric connection of geared motor has been polarized in the wrong way. Check pin connections. Pump does not run. Voltage is incorrect. Check voltage. Pump element does not deliver lubricant. Voltage supply is interrupted. Lubrication point is blocked or air pocket is present. Pump element is inoperative. Check voltage and the source. To find out which lubrication points and/or which lubrication point group is blocked, loosen pipe connections at pump elements one after the other. When the blocked bundle has been loosened, the pump must start running again. Localize the lubrication points concerned by loosening the connection lines. The failure may have been caused by dirt accumulation in the lubrication point, blocked up lubrication points or squeezed lines. To release air pocket, loosen pipe connections at pump elements and run pump until you have uninterrupted lubricant flow out of the elements. By loosening the pipe connections at the pump you will find the pump element which does not deliver lubricant after the pump has been switched on. Dirt accumulation within the piston element is a possible reason for the failure. If removal and purification of the pump element do not result in an improvement, the pump element must be replaced by a new one.

How To Order Name Lubricant Voltage Reservoir Capacity Low Level Switch Part # MultiPort Grease VDC liter (4 lb) No 30785-NF 3099-NF 4 liter (8 lb) No 857-NF 4 VDC liter (4 lb) No 8566-NF 30787-NF 4 liter (8 lb) No 857-NF 3037-NF 0 VAC liter (4 lb) No 8569-NF 0/440 VAC Three Phase 430-NF 4 liter (8 lb) No 8575-NF 380-NF liter (4 lb) No 8570-NF 4 liter (8 lb) No 8576-NF 4 liter (8 lb) 30559-NF 8 liter (6 lb) 8730-NF Oil 4 VDC liter (4 lb) 30787-NFO 4 liter (8 lb) 3037-NFO 0 VAC liter (4 lb) 430-NFO 0/440 VAC Three Phase 4 liter (8 lb) 380-NFO 4 liter (8 lb) 30559-NFO 8 liter (6 lb) 8730-NFO When ordering, specify by name, lubricant, voltage, reservoir capacity and part number, e.g. MultiPort, grease, 0 VAC, liter (4 lb) reservoir with low level switch, Part #430-NF. 3

Service Parts Grease Models Oil Models 7 3 8 4 6 7 5 8 9 3 4 5 6 9 0 3 0 4 4 Item Description Part # Low level switch 30544 Nut 076-5 3 Tie rod: liter (4 lb) 435-4 Tie rod: 4 liter (8 lb) 435-5 4 Reservoir: liter (4 lb) * 465- Reservoir: liter (4 lb) 805- Reservoir: 4 liter (8 lb) 805-5 Bottom reservoir seal 4583-6 Copper seal 5589-7 7 Copper seal 5589-5 8 Pump element w/ relief valve 878-3 9 VDC motor & worm gear 3703-4 VDC motor & worm gear 3703-0 VAC motor & worm gear 37-0/440 VAC motor & worm gear 37-4 0 Plug** 454 Grease fill fitting U4BC Fill fitting cover U43B * For reservoirs with rubber lid ** Copper seal (part #5589-7) required for installation. Item Description Part # Din connector 409 Low level tube: liter (4 lb) 4066-4 Low level tube: 4 liter (8 lb) 4066- Low level tube: 8 liter (6 lb) 4066-3 3 Low level switch B9640 4 Tie rod: liter (4 lb) 435-4 Tie rod: 4 liter (8 lb) 435-5 5 Reservoir: liter (4 lb) 4077- Reservoir: 4 liter (8 lb) 4077-6 Bottom reservoir seal 4583-7 Fill cap 34 8 Screen 36 9 Copper seal 5589-7 0/ Pump element w/relief 878-3 /4" NPT outlet* 49 3 4 VDC motor & worm gear 3703-0 VAC motor & worm gear 37-0/440 VAC motor & worm gear 37-4 4 Plug 454 * Included with items 0/.

Dimensional Schematics MultiPort VDC & 4 VDC Measurements shown in millimeters. 90 95 86 6 A B C 65 35 4 Reservoir A B C liter (4 lb) 45 35 90 4 liter (8 lb) 55 45 90 MultiPort 0 VAC, 0/440 VAC & Three Phase 90 375 86 6 A B C 65 5 305 Reservoir A B C liter (4 lb) 405 35 90 4 liter (8 lb) 505 45 90 8 liter (6 lb) 705 65 490 5

Wiring 0 VAC 0 VAC & 380/440 VAC Three Phase Z U U C V 0 VAC V Z CONNECTION W U V U V W CONNECTION Y W U V 0 VAC 380/440 VAC U V W VDC & 4 VDC YELLOW RED BLACK 6