MultiPort Lubricator Electric motor-driven, Grease and Oil General The MultiPort Lubricator is a rugged, motor-driven, electric lubricator, equipped with fixed output pumping elements to discharge grease or oil over a wide operating range. Low level switches are standard on this compact unit. Up to three independent feed lines can be used with the MultiPort Lubricator. A selection of timers and controller/monitors are available to program MultiPort Lubricators. Technical Data Reservoir Capacity, 4 and 8 liter (4, 8 and 6 lb) Lubricant Grease NLGI grade (Max) Oil Up to 5000 SUS Maximum Working Pressure Grease 3600 psi (40 bar) Operating Voltage Operating Temperature Range Pumping Elements to 3 Output per rpm Motor Low Level Switch Discharge Element Output Port Oil 900 psi (80 bar) As noted below 0 F to 0 F (-8 C to 49 C) 0.6cc (0.0 cu. in.) As noted below Available on some models (normally closed) /4" NPTF Fill Connection Grease Male filler fitting, quick disconnect Materials Motor Oil Fill cap Plastic, Steel (0/440 VAC grease) IP Enclosure Rating HP Rating Voltage Amperage Grease IP-55 0.068 VDC 4 FLA 4 VDC FLA 0.08 0 VAC.83 FLA 0/440 VAC 0.63 FLA Oil IP-55 0.068 4 VDC FLA Operates at 40 rpm @ 68 F, 000 psi back pressure Operates at 3 rpm (60 Hz) @ 68 F, 000 psi back pressure 0.08 0 VAC.83 FLA 0/440 VAC 0.63 FLA
Start Up Instructions.. 3. 4. The motor must be securely and adequately grounded. The power voltage must be correct. The motor rotating direction must be same as the arrow on motor end housing. The grease/oil must be clean. Fill the reservoir through fill cap and screen (oil). Fill the reservoir through the grease fill fitting (grease). Troubleshooting Symptom Possible Cause Remedy Pump does not deliver lubricant. Reservoir is empty. Fill up lubricant and run to charge elements. Electric connection of geared motor has been polarized in the wrong way. Check pin connections. Pump does not run. Voltage is incorrect. Check voltage. Pump element does not deliver lubricant. Voltage supply is interrupted. Lubrication point is blocked or air pocket is present. Pump element is inoperative. Check voltage and the source. To find out which lubrication points and/or which lubrication point group is blocked, loosen pipe connections at pump elements one after the other. When the blocked bundle has been loosened, the pump must start running again. Localize the lubrication points concerned by loosening the connection lines. The failure may have been caused by dirt accumulation in the lubrication point, blocked up lubrication points or squeezed lines. To release air pocket, loosen pipe connections at pump elements and run pump until you have uninterrupted lubricant flow out of the elements. By loosening the pipe connections at the pump you will find the pump element which does not deliver lubricant after the pump has been switched on. Dirt accumulation within the piston element is a possible reason for the failure. If removal and purification of the pump element do not result in an improvement, the pump element must be replaced by a new one.
How To Order Name Lubricant Voltage Reservoir Capacity Low Level Switch Part # MultiPort Grease VDC liter (4 lb) No 30785-NF 3099-NF 4 liter (8 lb) No 857-NF 4 VDC liter (4 lb) No 8566-NF 30787-NF 4 liter (8 lb) No 857-NF 3037-NF 0 VAC liter (4 lb) No 8569-NF 0/440 VAC Three Phase 430-NF 4 liter (8 lb) No 8575-NF 380-NF liter (4 lb) No 8570-NF 4 liter (8 lb) No 8576-NF 4 liter (8 lb) 30559-NF 8 liter (6 lb) 8730-NF Oil 4 VDC liter (4 lb) 30787-NFO 4 liter (8 lb) 3037-NFO 0 VAC liter (4 lb) 430-NFO 0/440 VAC Three Phase 4 liter (8 lb) 380-NFO 4 liter (8 lb) 30559-NFO 8 liter (6 lb) 8730-NFO When ordering, specify by name, lubricant, voltage, reservoir capacity and part number, e.g. MultiPort, grease, 0 VAC, liter (4 lb) reservoir with low level switch, Part #430-NF. 3
Service Parts Grease Models Oil Models 7 3 8 4 6 7 5 8 9 3 4 5 6 9 0 3 0 4 4 Item Description Part # Low level switch 30544 Nut 076-5 3 Tie rod: liter (4 lb) 435-4 Tie rod: 4 liter (8 lb) 435-5 4 Reservoir: liter (4 lb) * 465- Reservoir: liter (4 lb) 805- Reservoir: 4 liter (8 lb) 805-5 Bottom reservoir seal 4583-6 Copper seal 5589-7 7 Copper seal 5589-5 8 Pump element w/ relief valve 878-3 9 VDC motor & worm gear 3703-4 VDC motor & worm gear 3703-0 VAC motor & worm gear 37-0/440 VAC motor & worm gear 37-4 0 Plug** 454 Grease fill fitting U4BC Fill fitting cover U43B * For reservoirs with rubber lid ** Copper seal (part #5589-7) required for installation. Item Description Part # Din connector 409 Low level tube: liter (4 lb) 4066-4 Low level tube: 4 liter (8 lb) 4066- Low level tube: 8 liter (6 lb) 4066-3 3 Low level switch B9640 4 Tie rod: liter (4 lb) 435-4 Tie rod: 4 liter (8 lb) 435-5 5 Reservoir: liter (4 lb) 4077- Reservoir: 4 liter (8 lb) 4077-6 Bottom reservoir seal 4583-7 Fill cap 34 8 Screen 36 9 Copper seal 5589-7 0/ Pump element w/relief 878-3 /4" NPT outlet* 49 3 4 VDC motor & worm gear 3703-0 VAC motor & worm gear 37-0/440 VAC motor & worm gear 37-4 4 Plug 454 * Included with items 0/.
Dimensional Schematics MultiPort VDC & 4 VDC Measurements shown in millimeters. 90 95 86 6 A B C 65 35 4 Reservoir A B C liter (4 lb) 45 35 90 4 liter (8 lb) 55 45 90 MultiPort 0 VAC, 0/440 VAC & Three Phase 90 375 86 6 A B C 65 5 305 Reservoir A B C liter (4 lb) 405 35 90 4 liter (8 lb) 505 45 90 8 liter (6 lb) 705 65 490 5
Wiring 0 VAC 0 VAC & 380/440 VAC Three Phase Z U U C V 0 VAC V Z CONNECTION W U V U V W CONNECTION Y W U V 0 VAC 380/440 VAC U V W VDC & 4 VDC YELLOW RED BLACK 6