Electric Mortice Locks

Similar documents
Electric Mortice Locks

Lockwood Security Products Pty Limited Series. Electric Mortice Lock Collection

Electromechanical Bolts

6 assaabloy.com.au

Electric Strikes. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

3580 Series Cylinder Mortice Locks. Keeler Hardware. telephone

EL110 Electric Cabinet Lock

Key in Lever and Key in Knob Locksets

002 Digital DX Deadlatch

Series. Electric Mortice Lock Collection. An ASSA ABLOY Group brand

Locksets Nexion. Mechanical Locksets

Mechanical Entrance Locksets

3540 Series Short Backset Mortice Locks. ASSA ABLOY, the global leader in door opening solutions 2

693 Pin Tumbler Cupboard Lock. Deadbolts

Mechanical Entry Locksets

Mechanical Digital Locks

Lockwood Keyless Locking Solutions

ELECTRIC LOCKS. Europrofile range

Access Control Electric Locking. Security Systems. Reader Technology

E. Electromechanical Solutions

Mechanical Entry Locksets

Floor Closers. Floor Closers Concealed Overhead Transom Door Closers Door Closers

Rimlocks. ASSA ABLOY, the global leader in door opening solutions

Contents. Hydraulic Door Closer Series. Arrow A2600 Series Size Power Adjustable Hydraulic Door Closer

Rimlocks Overview 2.36

Rimlocks. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Security Screen Door Hardware

EL Series. Electric Cabinet Lock. General Description. Key Features. Applications. Technical

Key in Lever and Key in Knob Locksets. Locksets Key in Knob and Key in Lever

Trimec Product Brochure

PRODUCT BULLETIN NO. 032

Pentagon Mortice Locks

Electromechanical Door Solutions. The global leader in door opening solutions

Contents Introduction, Performance Features, Services & Guarantee Dimensional Details, Ordering Procedure & Handing Chart 6100 Series Vestibule Locks

3540 Series Short Backset Mortice Locks. Keeler Hardware. telephone

Sliding Door Hardware

Keyless Entry. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Electromechanical Door Solutions

Electric locks ELECTRIC LOCKS

Lockwood Security Products Pty Limited. Key in Lever. Locksets

RIM LOCKS. An ASSA ABLOY Group brand ASSA ABLOY

Synergy Mortice Locks

Information provided by H. A. Reed Locksmiths Locksets 530 Series Key in Knob Locksets 2.61 Mechanical Locking Solutions

E-Plex 5700 Series E-PLEX

Bolts. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

SECTION E. Hinged Door Hardware. Lever Compression Lock Twin Bolt French Door Lockset. Cylinders E13-14 Securiturn Key in Knob Sets E16-19.

Door closers catalogue 2008

E-Plex 5700 Series E-PLEX

TRADITIONAL DOOR LOCK

Electromechanical Door Operators and Closers. Electromechanical Door Operators Door Closers

Keeler Hardware. telephone Rimlocks. ASSA ABLOY, the global leader in door opening solutions

CK4400 Series. Standard Duty Cylindrical Knob Locksets

Window Balance System

Window Locking 10YEAR. whitco.com.au

Interconnected Locksets. ANSI/BHMA Grade 2 Certified Mechanical Electronic. An ASSA ABLOY Group brand

Commercial Mortice Locks Pentagon 3P70 series Mortice Locks overview

3200 Series Cylindrical Lock

High Security Mortise Lock and M-9200 MOGUL Institutional Mortise Lock

3400 Series

Door Closers. Surface Mounted Door Closers

COMMERCIAL DOOR HARDWARE PRODUCT CATALOG HOME DEPOT EXCLUSIVE SPECIAL ORDER PROGRAM FOR MORE INFORMATION

4500/4600/4300 SERIES KEY IN LEVER LOCKSETS. ainsborough now offers a broad selection of key in lever lockset

Door Stays. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Product Catalog Series High Security Mortise Lock and M-9200 Series MOGUL Institutional Mortise Lock

Our passion for quality and service means we are the only brand in our market sector which offers:

MODELS TRUE WOOD DOOR OPERATIONAL HARDWARE EXIT DEVICE MODELS LEVER X LEVER MODELS DOORS WITH FLUSHBOLTS:

Our passion for quality and service means we are the only brand in our market sector which offers:

EL2000 Series Lockcase

Master the Mood with Lockwood

Grade 1 Heavy-Duty Cylindrical Locksets DORMA CL800 CK800

Supplied standard with D and T strikes and spacer rings.

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

Lock Functions Single Cylinder Deadbolt Functions

Fire control. Electromagnetic fire Door Retainers. Available Models

Light/Medium-Duty Knob Locksets. CK4700 Series

Table of Contents Auxiliary Locks

LS-SERIES Features LS-1 LS-2 & LS-2P LS-2P

Table of Contents 20 Series Exit Device

Electromechanical Door Closers and Operators

Non-handed, pre-assembled for left hand door installation easily changed in the field

SECTION D. Bi-Folding Window and Door Hardware

4.5. Electronics. Electric Strikes. Electronics

ANSI/BHMA CODE. PRODUCT OPTIONS DEDUCT ADD LESS CYLINDER: Specify "x LC" Cylinder rings/collars not furnished with locksets ordered less cylinders.

20 Series. Exit Device

SARGENT 8200 Nomenclature

Briton. Door hardware and security products. Normbau. Coloured nylon design systems. Randi. Scandinavian stainless steel design systems CISA

Smart access means Dorma and Kaba Joining Forces

Table Of Contents. 30 Series Exit Device. On The Cover

MB1 Series ANSI Grade 1 Extra Heavy Duty Lever Locks

ADAMS RITE. ADAMS RITE MANUFACTURING COMPANY Sliding Hardware/Exit Devices Series Turns

4700LN Series ANSI/BHMA Grade 1 Certified Cylindrical Lever Locks. An ASSA ABLOY Group brand

!!!! ! Lock housing dimensions: 230mm L x 44mm W x 44mm D! Receptacle housing dimensions: 120m L x 44mm W x 44mm D. ! Surface mount housing for LK120

GRADE 1 ELECTRIFIED CYLINDRICAL & UNIT LOCKS

CI/SfB (31.59) X. June Briton. Cylinder Lockcases

Australian Price Book

Simplex. Cylindrical Knob Series. Grade 1 Extra Heavy Duty Cylindrical Knob

Locks TABLE OF CONTENTS. A Armor Fronts (Mortise)

8800 series grade 1 mortise locks

RETRO SOLUTIONS PRODUCT CATALOG

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Transcription:

Electric Mortice Locks

Strikes Contents 3570 Series Electric Mortice Lock 2 3570/3670 Series Proximity Mortice Lock & Furniture 8 3570 Series Room Guard Electric Mortice Locks & Controller 12 3580 Series Electric Mortice Lock 14 EL402 Solenoid Lock 20 EL502 Solenoid Lock 22 EL580 Solenoid Lock 24 EL648 Motor lock 26 Power Transfer Cover 28 1

3570 Series Electric Mortice Lock General Information Designed and manufactured in Australia, the 3570 series electric mortice is a high performance lock of superior quality. It is constructed from high grade zinc alloy, with a stainless steel latch bolt and face plate and is suited for all commercial applications. The lock can be operated by push buttons, intercom systems and key switches; or integrated with electronic access control systems for use with higher security devices such as keypads or card readers. Key Features Designed with flexibility in mind, the one lock can cover all functions and is easily configured on site for the required application. Available in non monitored and monitored versions. Monitoring features: Dead latched and Locked Door position/reed switch Dual key override monitoring Request to exit/rex LED indication Field Changeable settings: Fail safe/fail secure configuration. Multi-voltage - will work on 12-24 Vdc systems. Handing - left hand and right hand doors Selection of free lever or locked lever on both sides of the door Key override monitoring either side of the door Monitoring contacts normally closed, normally open (for key override and request to exit only) Standards and Compliance S3 D3 4 Hour (Security) Australian Lock Standard (AS4145.2.1993) (when used with equivalent security level keying system) (Durability) Australian Lock Standard (AS4145.2.1993) Successfully fire rated up to 4hrs on fire door assemblies in accordance with AS1905.1. 2005 (Part 1: Fire resistant door sets) C-Tick Certified 3570 Series: SCEC endorsed for intruder resistant areas 3579 Series: SCEC endorsed for secure areas 2 assaabloy.com.au

3570 Series Electric Mortice Lock A 37 26 14 24 68 39 18 Reed Magnet 28.5 64 124 175 57 15 70 30 15 19 54 1.5 4 B 25 18 28.5 32 46 Note: width of case increases from 19mm to 23 mm for 3579 series SCEC lock 38 Dimension A 60 89 127 B 100 129 167 3570 Technical Information Voltage Current LED Current Monitoring Environment 12Vdc - 24Vdc Operating Voltage 500mA (max) 80mA holding @ 12Vdc 275mA (max) 50mA holding @ 24Vdc When LED s are fitted, add 15mA (max) to total current draw Dual Key override Deadlatched Locked Door closed Request to exit Microswitches: 500mA (max) @ 30Vdc each circuit. Reedswitch: 100mA (max) @ 30Vdc Operational temperature range -20c to + 60c Specification Statement The lock should be capable of operation on voltages between 12 24Vdc and have a current consumption not more than 80mA (holding) @12Vdc and 50mA (holding) @24Vdc. Monitored locks must be capable of monitoring the following functions: Key override, door position / reed switch, selectable hub / Request to exit, & locking bar status. All monitoring outputs must have the ability to be wired independently. All settings including: fail safe / fail secure, handing, hub selection must be field configurable. Case/ Cover Latch bolts Door Clearance Door thickness Cylinder Cabling Furniture Standard Finishes High purity Zinc alloy construction 60mm standard, 89 & 127 mm available Reversible with Stainless Steel construction. 3 6.5 mm Standard applications 32 to 50mm. Standard Lockwood oval shaped cylinders. 1.6 metre length of cable with 12 pin socket supplied with each lock. Recommended cable: 18AWG (0.82mm²) cable runs up to 30m. Compatible with Lockwood series door furniture. Satin Chrome(SC) standard. Bright Chrome (CP) and Polished Brass(PB) finishes available Note: For detailed electrical specifications, turn to page 7. 3

3570 Series Electric Mortice Lock Ordering Procedure Sample Part Number 3572ELAM2RSC is made up of several sections. Choose your product by selecting an option from each section. For example: Fixing Lock Functions Electric Lock Safety Function Sub Function Handing Finish 3 5 72 EL A M2 R SC 60 mm 3 89 mm 4 127 mm 5 Fixing Standard 5 Securafix 6 Lock Functions Primary lock 70 Vestibule lock 72 Combination lock 74 Secure Area Rated Lock 79 Electric Lock Electric Lock Nominate backset as required, eg 60mm 3 Fixing Select the desired fixing method, eg Standard Fixing 35 35 EL Safety Function Fail Safe (Power to lock) Fail Secure (Power to unlock) Sub Function Non-monitored lock (0 Cylinders) N0 Non-monitored lock (1 Cylinders) N1 Non-monitored lock (2 Cylinders) N2 Fully monitored lock including KOM (0 Cylinders) M0 Fully monitored lock including KOM (1 Cylinder) M1 Fully monitored lock including KOM (2 cylinders) M2 KOM- (Key overrride moitoring) A E Right Handing Right Handing Left Handing Finish Satin Chrome Chrome Plate Polished Brass R L SC CP PB Ordering Notes 3570 Primary Locks can be set to achieve all lock functions post purchase, and should be the preferred option when ordering. Lock Function Select function, eg Vestibule Lock 3572 Electrical Variant Indicate that this is an Electric Lock Safety Function Select whether lock should be Fail Secure or Fail Safe, eg Fail Safe 3582EL 3572ELA Customised locks are available upon request and incur an additional surcharge and 10 day lead time. Securafix locks are available in 60mm backset only and are made to order. 10 day lead time. Monitoring and Key Override Options Select monitoring and cylinders to be supplied, eg Monitored Lock with two cylinders Handing Determine left or right handing, eg Right Handed Finish Specify appropriate finish, eg Satin Chrome 3572ELAM2 3572ELAM2R 3572ELAM2RSC See over page for Primary Lock part numbers. Handing Chart RIGHT HAND DOOR OPENING IN INSIDE OUTSIDE LEFT HAND DOOR OPENING OUT INSIDE RIGHT HAND OUTSIDE LEFT HAND 4 assaabloy.com.au

3570 Series Electric Mortice Lock Ordering Notes Primary locks can be set post purchase to achieve all desired lock settings e.g. fail safe or fail secure, left hand or right hand, combination lock (locked both sides) or vestibule lock (locked outside & free lever inside) All locks are Multi-voltage 12-24Vdc 3570 Primary locks (std 60mm backset) are stocked items. All other items are made to order, 10 day lead time. Primary Electric Mortice Lock Ordering Procedure Description - Non-Monitored Cylinders Part No Electric Mortice Lock 3570 Primary Lock 60 mm Non Monitored No Cylinder 3570eln0sc Electric Mortice Lock 3570 Primary Lock 60 mm Non Monitored 1 Cylinder 3570eln1sc Electric Mortice Lock 3570 Primary Lock 60 mm Non Monitored 2 Cylinder 3570eln2sc Electric Mortice Lock 4570 Primary Lock 89mm Non Monitored No Cylinder 4570eln0sc Electric Mortice Lock 4570 Primary Lock 89 mm Non Monitored 1 Cylinder 4570eln1sc Electric Mortice Lock 4570 Primary Lock 89 mm Non Monitored 2 Cylinder 4570eln2sc Electric Mortice Lock 5570 Primary Lock 127 mm Non Monitored No Cylinder 5570eln0sc Electric Mortice Lock 5570 Primary Lock 127 mm Non Monitored 1 Cylinder 5570eln1sc Electric Mortice Lock 5570 Primary Lock 127 mm Non Monitored 2 Cylinder 5570eln2sc Description - Monitored (hub, deadlatch, solenoid, door position, key override monitoring all as standard) Cylinders Part No Electric Mortice Lock 3570 Primary Lock 60 mm Monitored No Cylinder 3570ELM0SC Electric Mortice Lock 3570 Primary Lock 60 mm Monitored 1 Cylinder 3570ELM1SC Electric Mortice Lock 3570 Primary Lock 60 mm Monitored 2 Cylinder 3570ELM2SC Electric Mortice Lock 4570 Primary Lock 89 mm Monitored No Cylinder 4570ELM0SC Electric Mortice Lock 4570 Primary Lock 89 mm Monitored 1 Cylinder 4570ELM1SC Electric Mortice Lock 4570 Primary Lock 89 mm Monitored 2 Cylinder 4570ELM2SC Electric Mortice Lock 5570 Primary Lock 127 mm Monitored No Cylinder 5570ELM0SC Electric Mortice Lock 5570 Primary Lock 127 mm Monitored 1 Cylinder 5570ELM1SC Electric Mortice Lock 5570 Primary Lock 127 mm Monitored 2 Cylinder 5570ELM2SC 5

3570 Series Electric Mortice Lock 14 Accessories - Rebate Kits 12.7 4 29 Finish A Part Number 26.5 1.5 Bright Chrome 32 3570-2905BC 46 3570-3905BC Polished Brass 32 3570-2905PB 46 3570-3905PB Satin Stainless Steel 32 3570-2905SC 46 3570-3905SC 177 184 51 75 A Accessories - Long Lipped Strikes Finish A Part Number Bright Chrome 43.5 3570-5353CP 47.5 3570-5653CP Polished Brass 43.5 3570-5353PB 47.5 3570-5653PB Satin Stainless Steel 43.5 3570-5253SSS 47.5 3570-5453SSS 1.5 46 28.5 70 54 38 Long Lipped Strike A Accessories Ordering Information Product Description Part Number LED assembly to suit 3570/3580 SP572-3129 (suits furniture for monitored locks) 7.5m extended 12 wire cable SP3570-1055 9/12 wire adaptor to suit 3570 series electric lock SP3570-5861 323mm Power Transfer Cable LC8810 543mm Power Transfer Cable LC8811 Extended Cylinders Extended cylinders should be considered when door thickness exceeds 50 mm or when the lock is mounted off centre in the door edge. A range of cylinders is available to suit various door thicknesses. Refer to ASSA ABLOY Australia Keying and Restricted Price List for further information. Extended Cylinders A A Cylinder Projection Cylinder Length Recommended Door Thickness 41 37 50 to 60 52 48 60 to 84 64 60 84 to 108 80 76 108 to 132 88 84 132 to 156 6 assaabloy.com.au

3570 Series Electric Mortice Lock Electrical Specifications Circuit Diagram Note: Diagram depicts fail safe RH opened door, with handle and key in rest state. 12 Pin Connector DIL Switch Settings Hub Monitor Switch Number 1 2 3 4 Lock Side Normal Function ON OF F A N / C ON OF F A N / O ON OF F ON OF F B B N / C N / O Deadlatched and locked centre tap (White) Key Override Monitor Selection SIDE B Key Override Monitor Selection N/O N/C K.O.M SWITCH SELECTION Key Override Monitor Selection Set the 2 way switch to desired setting Hub Monitor Selecion Solenoid Activation Operating Voltage: 12-24Vdc Operating Current: 500mA (max) 80mA holding @ 12Vdc 275mA (max) 50mA holding @ 24Vdc For confirmation of the above mentioned operating current, please see installation manual. LED Current Where LEDs are fitted, add 20mA (max) to total operating current. Monitoring Circuits Microswitches: 500mA (max) @ 30Vdc each circuit Reedswitch: 100mA (max) @ 30Vdc Colour Black Red Green Yellow Pink Light Blue Grey White Brown Blue Orange Violet Function Solenoid (0Vdc) Solenoid Positive (12Vdc - 30Vdc) LED (12Vdc - 30Vdc) Door closed Reedswitch (NC) Door closed Reedswitch (common) Deadlatched and Locked (NC) Deadlatched and Locked (common) Deadlatched and Locked centre tap Hub monitor (NO or NC) Hub monitor (common) Key override monitor (NO or NC) Key override monitor (common) 7

3570/3670 Series Proximity Mortice Lock & Furniture General Information When security, safety, functionality and stylish design are a priority, there s only one solution Lockwood Proximity Furniture! Incorporating proximity technology within its sleek external door plate, the reader connects directly to a Lockwood electric mortice lock. Easy to install and operate, Lockwood Proximity Furniture is available in a wide range of stylish levers and finishes to enhance any contemporary building design, bringing a new dimension to commercial security locking solutions. One Install One Connect. Comprising the Lockwood Electric Mortice Lock, HID Proximity Reader and Door Furniture. Proximity Furniture is available in standard through fix and Securafix specifications. Key Features Integrated proximity reader -125 Khz HID Prox One install one connect Fully monitored Monitoring features: Dead latched and locked Door position/reed switch Dual key override Request to exit/rex Field Changeable settings: Fail safe/fail secure configuration. Standards and Compliance Multi-voltage - will work on 12-24 Vdc systems. Handing - left hand and right hand doors Selection of free lever or locked lever on both sides of the door LED indication Monitoring contacts normally closed, normally open (for key override and request to exit only) S3 D3 4 Hour (Security) Australian Lock Standard (AS4145.2.1993) (when used with equivalent security level keying system) (Durability) Australian Lock Standard (AS4145.2.1993) Successfully fire rated up to 4hrs on fire door assemblies in accordance with AS1905.1. 2005 (Part 1: Fire resistant door sets) C-Tick Certified 8 assaabloy.com.au

3570/3670 Series Proximity Mortice Lock & Furniture A 37 15 15 19 24 18 28.5 64 124 175 18 Reed Magnet 57 30 26 14 70 4 B 25 54 1.5 68 39 28.5 32 46 38 3570/3670 Technical Information Specification Statement HID Reader Lock Voltage Current Indicator Monitoring HID 125KHz Proximity Reader Data Output: Weigand Supply voltage: 5-12Vdc LED: visual indication of reader / lock status 12Vdc - 24Vdc 500mA (max) 80mA holding @12Vdc 275mA (max) 50mA holding @24Vdc LED signalling door status Dual Key override Deadlatched Locked Door closed Request to exit Microswitches: 500mA (max) @ 30Vdc each circuit. Reedswitch: 100mA (max) @ 30Vdc The lock and door furniture should encompass an integrated proximity reader, capable of reading HID 125khz proximity technology with card formats up to 85bits. Operational voltage should be between 12-24Vdc. The lock must be capable of monitoring the following functions: Key override, door position / reed switch, independent hub / Request to exit, & locking bar status. All settings including: fail safe / fail secure, handing, hub selection must be field configurable. Environment Operational temperature range -20 C to + 60 C Case/ Cover Latch bolts Door Clearance Door thickness Cylinder Cabling Mortice Lock Standard Finishes Furniture: Solid Brass construction Lock: High purity zinc alloy construction Lock available in 60mm backset only Reversible 15mm Stainless Steel construction. 3 6.5mm Standard applications 32 to 45mm standard. Standard Lockwood oval shaped cylinders. 1.6 metre length of cable with 12 pin socket Recommended cabling: 18AWG (0.82mm²) cable runs up to 30m Compatible with Lockwood 3572PL and 3672PL electric mortice lock Satin Chrome(SC) standard. Bright Chrome (CP) and Polished Brass(PB) finishes available Note: For detailed electrical specifications, turn to page 11. 9

3570/3670 Series Proximity Mortice Lock & Furniture Ordering Procedure Sample Part Number 3570PLM0SC is made up of several sections. Choose your product by selecting an option from each section. For example: Ordering Notes All 3570 & 3670 series proximity locks are non handed and can be set to required settings post purchase 3 Fixing 5 Lock Functions 70 Proximity Lock PL Monitoring M0 Finish SC Accessories Ordering Information Product Description Part Number Lock Functions Monitoring 12 Wire cable extension 7.5m length 3570-1055 60 mm 3 Fixing Standard 5 Primary Lock 70 Proximity Lock Proximity Lock PL Monitored Lock including KOM (0 cylinders) Monitored Lock including KOM (1 cylinders) M0 M1 125 Khz HID reader assembly for prox furniture prox1-125khz Securafix 6 Finishes Satin Chrome Bright Chrome Polished Brass SC CP PB Proximity Furniture Ordering Procedure Sample Part Number 1878SF70RCP55 is made up of several sections. Choose your product by selecting an option from each section. For example: Plate Type Plate Function Fixing Lever/ Knob Handing Finishes Door Thickness 18 78 SF 70 R CP 55 Plate Type Fixing Handing Door Thickness Exterior Square End 18 Standard (no suffix) Right handed R 32-45mm (no suffix) Exterior Round End 28 Securafix SF Left Handed L 45-55mm 55 Plate Function Exterior plate with HID 125 khz Proximity Reader 78 Internal Plain plate & lever 05 Lever/Knob Specify lever or knob. Subject to existing tier structure Tier 1 00, 20, 32, 39, 40, 60, 70, 71, 78, 80, 83, 87, 90, 97. Finishes Chrome Plate Polished Brass Satin Chrome CP PB SC 55-65mm 65 65-75mm 75 Tier 2 41, 43, 44, 45, 48, 50, 53, 54, 57, 59, 61, 69, 72, 73, 74. Securafix Ordering Notes: One internal plate and one external plate is required for each lock. For each set of furniture plates, one must be handed R and one handed L. Furniture plates are ordered separately to the Lock. The handing of Securafix plates cannot be changed. RIGHT HAND RIGHT HAND DOOR OPENING IN INSIDE OUTSIDE DOOR OPENING OUT INSIDE OUTSIDE LEFT HAND LEFT HAND 10 assaabloy.com.au

3570/3670 Series Proximity Mortice Lock & Furniture Pin Colour Function 1 Black Common 0Vdc 2 Red Soleniod Positive 3 L. Blue Deadlatch Monitor N/C 4 Blue Door Monitor Reed N/C 5 Grey Hub Monitor N/O or N/C 6 Violet Key Override Monitor N/O or N/C 7 Brown Monitor Common 8 Pink Reader Power 5-12Vdc 9 Orange Green LED 10 Yellow Reader 0Vdc 11 Green Weigand Data 0 12 White Weigand Data 1 Plug Housing From Electric Lock To Power Supply Receptacle Housing 11

3570 Series Room Guard Electric Mortice Locks & Controller The Room Guard Privacy controller system provides electronic lock control of multiple doors for any room requiring privacy by the occupants. The most common applications are shared ensuites in hospitals and conference rooms with two or more entry doors. INSIDE ROOM The system allows all doors to be locked and unlocked from any door in the system. Each lock provides a clear visual indication, both inside and outside, which displays the locked/unlocked status of the door at a glance. Features Uses standard 3570EL series mortice lock 12Vdc regulated power supply Emergency override switches (outside room) Room Guard Privacy Controller Non handed all settings are field configurable One touch privacy Clear visual indication - LED furniture Unique integrated turn knobs Emergency override Applications Shared ensuites/toilets Power Transfer Device LED Turn Knob Darkroom studios Conference rooms Laboratories Any area for which one touch privacy locking is required Function In the dormant state, all locks are unlocked and the LED on the external furniture plate indicates green. To lock the lock 1. Close all doors 2. Activate one of the turn knobs located on the inside of the door 3. Simultaneously the lever handles on the outside of each door will lock and the LED furniture indication will change to red. (inside lever will remain free at all times) To Unlock the Room 1. Operate the inside lever of either lock. 2. Simultaneously the locks will unlock and the LED furniture indication will return to green. Standards and Compliance S3 D3 4 Hour 3570 EL Electric Mortice Lock (Security) Australian Lock Standard (AS4145.2.1993) (when used with equivalent security level keying system) (Durability) Australian Lock Standard (AS4145.2.1993) Successfully fire rated up to 4hrs on fire door assemblies in accordance with AS1905.1. 2005 (Part 1: Fire resistant door sets) C-Tick Certified Power Transfer Device 12 assaabloy.com.au

3570 Series Room Guard Electric Mortice Lock & Controller Room Guard Privacy Controller Standard Two Door Connection 3570 EL Electric 3570 EL Electric Pink Pink 3570 Series Room Guard Technical Information Voltage Current LED Current Monitoring Environment Case/Cover Latch bolts Door Clearance Door thickness Cylinder Cabling Furniture Standard Finishes 12Vdc - 24Vdc 500mA (max) 80mA holding @ 12Vdc 275mA (max) 50mA holding @ 24Vdc When LED s are fitted, add 15mA (max) to total current draw Microswitches: 500mA (max) @ 30Vdc each circuit. Reedswitch: 100mA (max) @ 30Vdc Operational temperature range -20c to + 60c High purity Zinc alloy construction 60mm standard, 89 & 127 mm available Reversible with Stainless Steel construction 3 6.5 mm Standard applications 32 to 50mm Standard Lockwood oval shaped cylinders 1.6 metre length of cable with 12 pin socket supplied with each lock Recommended cable: 18AWG (0.82mm²) Compatible with Lockwood series door furniture Satin Chrome(SC) standard. Bright Chrome (CP) and Polished Brass(PB) finishes available Note: For detailed electrical specifications, turn to page 7. Accessories Ordering Information Product Description Part Number 7.5m extended 12 wire cable SP3570-1055 9/12 Wire adapter to suit 3570 series electric lock SP3570-5861 Specification Statement Locking control of the room must be via a standalone door controller independent of the building electronic access control system. The controller shall be capable of providing simultaneous locking/unlocking of up to 4 locks via internal integrated turn knobs. Emergency egress or unlocking to be achieved via single downward action of internal lever or externally mounted override switch. The locks should be capable of operation on voltages between 12 24Vdc. All lock settings including: fail safe/fail secure, handing, hub selection must be field configurable. Ordering Information Product Description Room Guard Privacy Controller plus regulated power supply (12Vdc, 1.5AMP). Room Guard Privacy Controller. Turn knobs, designed for the integrated assembly with Lockwood electric mortice locks. Other finishes available upon application. RG2PS RG2 RG3SC 1 x Room Guard Privacy Controller RG2PS or RG2 2 x Room Guard Privacy Controller turn knobs RG3SC 2 x Electric Mortice Locks 3570ELM0SC 2 x Power transfer devices LC8810 Part Number A typical room with two doors requires the following equipment: 2 x Exterior door furniture 1822/70SC 2 x Interior door furniture 1920/70SC 2 x 7.5M extended cables SP3570-1055 Note: Due to the variety of installation décor, Lockwood does not supply emergency release push buttons. However we recommend a Clipsal model 31 architrave mounting plate with model 30MBP push button, or equivalent, available from most electrical wholesalers. 13

3580 Series Electric Mortice Lock Designed and manufactured in Australia, the 3580 series electric mortice is a high performance lock of superior quality. It is constructed from high grade zinc alloy, with a stainless steel latch bolt and face plate and is suited for all commercial applications. The lock can be operated by push buttons, intercom systems and key switches; or integrated with electronic access control systems for use with higher security devices such as keypads or card readers. The 3580 series is available in a wide variety of configurations to suit varying requirements and is especially suited to narrow style or short backset applications. Key Features Available in non monitored and monitored versions. Monitoring features: Dead latched Door position/reed switch Key override Request to exit/rex Available configurations: Fail safe or fail secure 12Vdc or 24Vdc Field changeable monitoring contacts normally closed, normally open Field changeable handing - Left hand and right hand doors Selection of free lever or locked lever on both sides of the door Key override monitoring Standards and Compliance S2 D3 (Security) Australian Lock Standard (AS4145.2.1993) (Durability) Australian Lock Standard (AS4145.2.1993) C-Tick Certified LED indication 14 assaabloy.com.au

3580 Series Electric Mortice Lock Limiting Dimensions 36.5 3 25 Dimension X 23 25.4 30 38 32 Y 36.4 39 43.6 51.7 90 28 212.5 155.5 79 1.5 46 24 15 1.5 20 260 32 Y 70 54 38 100 54 86 39 24 15 X 18 28.5 27 1.5 Reed Magnet 15 18 25 3580 Series Technical Information Voltage Current LED Current Monitoring Available in 12Vdc or 24Vdc 12Vdc ± 5% 250mA (max) 24Vdc ± 5% 125mA (max) When LED s are fitted, add 15mA (max) to total current draw Key override Deadlatched and door closed Request to exit Hub/Deadlatch/Key override monitor: max ratings 500mA@30Vdc Door Status Monitor: max ratings 3W, 250mA (max) @ 12Vdc, 125mA (max) @24Vdc Environment Operational temperature range -20 c to + 60 c Case/ Cover Latch bolts Door Clearance Door thickness Cylinder Cabling Furniture Standard Finishes High purity zinc alloy construction 23mm standard. 25.4, 30 & 38 mm extended available 15mm Stainless Steel construction 3 6.5 mm Standard applications 32 to 50mm Extension kits available Standard Lockwood oval shaped cylinders 3.6 metre length of cable with 9 pin socket supplied with each lock. Recommended cabling: 18AWG (0.82mm²) cable runs up to 30m Compatible with Lockwood series door furniture Satin Chrome(SC) standard. Bright Chrome (CP) and Polished Brass(PB) finishes available Accessories Ordering Information Product Description Anti-Clockwise Rebate Kit Replace ## with finish code (SC, CP, PB) Part Number 3580-2902AC## Clockwise Rebate Kit Replace ## with finish code (SC, CP, PB) 35802902CW## LED Assembly to suit 3570/3580 SP572-3129 7.5m extended 9 wire cable SP3580-1052 Specification Statement The lock should be capable of operation on voltages of 12 or 24Vdc and have a current consumption not more than 250mA (max) @12Vdc and 125mA (max) @24Vdc. Monitored locks must be capable of monitoring the following functions: Key override, door position/reed switch & independent hub/ Request to exit. All monitoring outputs must have the ability to be wired independently. The lock must be capable of operating fail safe or fail secure, left or right hand, and have field configurable hub selection. Note: For detailed electrical specifications, turn to page 18. 15

3580 Series Electric Mortice Lock Ordering Procedure Sample Part Number 3582ELAM2RSC62 is made up of several sections. Choose your product by selecting an option from each section. For example: Door Material Lock Function New Product Safety Function Sub Function Handing Finish Options 3 58 2 EL A M2 R SC 62 Lock Function Safety Function Handing 23 mm 3 25.4 mm 4 30 mm 5 38 mm 6 Vestibule lock 2 Combination Lock 4 New Product Fail Safe (Power to lock) Fail Secure (Power to unlock) A E Right Handing Left Handing Finish R L Door Material Metal 58 Timber 59 EL Sub Function Non-monitored lock (0 Cylinders) N0 Non-monitored lock (1 Cylinder) N1 Bright Chrome Polished Brass Satin Chrome Options CP PB SC Non-monitored lock (2 Cylinders) N2 24 volt model 62 Monitored Lock (0 Cylinders) M0 Monitored Lock (1 Cylinder) M1 Monitored Lock (2 Cylinders) M2 Monitored Lock including KOM (0 Cylinder) M4 Monitored Lock including KOM (1 Cylinder) M5 KOM- (Key overrride moitoring) Nominate backset as required, eg 23mm 3 Door Material Nominate door material, eg Metal 358 Lock Function Select function, eg Vestibule Lock 3582 Electrical Variant Indicate that this is an Electric Lock Safety Function Select whether lock should be Fail Secure or Fail Safe, eg Fail Safe Monitoring and Key Override Options Select monitoring and cylinders to be supplied,eg Monitored Lock with 2 cylinders Handing Determine left or right handing, eg Right Handed Finish Specify appropriate finish, eg Satin Chrome Options Specify 24Vdc opion when required 3582EL 3582ELA 3582ELAM2 3582ELAM2R 3582ELAM2RSC 3582ELAM2RSC62 16 assaabloy.com.au

3580 Series Electric Mortice Lock Accessories Rebate kits to suit 13 mm rebated timber doors with a minimum backset of 30 mm includes an adaptor to mount the lock and a special strike plate. Handing of the rebate kits is determined by the opening movement of the door on which the lock is fitted. 12.7 4 14 29 26.5 1.5 Finish Anti-clockwise Clockwise Satin Chrome 3580-2902ACWSC 3580-2902CWSC Bright Chrome 3580-2902ACWCP 3580-2902CWCP Polished Brass 3580-2902ACWPB 3580-2902CWPB 177 184 51 75 A Extended Cylinders Extended cylinders should be considered when door thickness exceeds 50 mm or when the lock is mounted off centre in the door edge. A range of cylinders is available to suit various door thicknesses. Refer to ASSA ABLOY Australia Keying and Restricted Price List for further information. A A Cylinder Projection Cylinder Length Recommended Door Thickness 41 37 50 to 60 52 48 60 to 84 64 60 84 to 108 80 76 108 to 132 88 84 132 to 156 17

3580 Series Electric Mortice Lock Electrical Specifications Circuit Diagram Note: Diagram depicts fail safe 12V RH opened door, with handle and key in rest state. 9 Pin Connector 1 Common Red Solenoid Protection Diode EXTERNAL LED Green Resistor Reedswitch 2 3 Solenoid 12V dc Common Deadlatch and door closed status Hub Monitor Switch No. 1 2 3 4 ON OFF Lock Side A Normal Function N / C C NO NC (1) 4 5 Deadlatch and door closed status LED ON OFF A N / O (2) 6 Hub monitor common ON OFF ON OFF Key Override Monitor Selection Set the 2 WAY DIL SWITCH to desired setting, refer to table. Switch No. Normal 1 2 Function ON OFF N / O B B N / C N / O C NO NC (1) (2) C C LHS RHS NO NC NO NC (3) (4) DIL SWITCH 7 8 Hub monitor ( LH/RH, NO/NC ) Key override monitor ( NO/NC ) ON OFF N / C DIL SWITCH 9 Key override monitor common Pin Colour Function 1 Black Common (0Vdc) 2 Red Solenoid (12Vdc or 24Vdc) 3 Grey Deadlatch and door closed status (common) 4 Yellow Deadlatch and door closed status 5 Green LED 6 Brown Hub monitor (common) 7 Blue Hub monitor (RH/LH, NO/NC) From electrical lock 8 Orange Key override monitor (NO/NC) 9 Violet Key override monitor (common) Plug Housing Receptacle Housing To power supply 18 assaabloy.com.au

Electric Mortice Locks 19

ABLOY EL402 Solenoid Lock General Description ABLOY EL402 is typically used in the interior doors of business premises and educational buildings. The locks include a special double action bolt for quick and easy use and offer a cost-effective way of electric locking without compromising performance. The locks can be controlled by a variety of electrical impulse generating equipment such as card readers, keypads and timers. The locks can be connected to automatic swing door operators and are an excellent solution for access control systems. The new revolutionary adjustable backset feature offers unique flexibility that s never been available before. Because of its symmetrical trigger bolt, ABLOY EL402 can be used in double swing doors. The lock can always be opened mechanically by key or by thumb turn and the bolt deadlocks automatically when the door closes. Key Features Field selectable Fail Safe/Fail Secure configuration Non Handed Symmetrical trigger bolt Visual Lock Status indicator Immediate release of Deadlocking Push or Pull operation Wide Operating Voltage Adjustable Between 25 35 to suit most narrow style applications. Applications Offices Storage rooms Consulting rooms (All Narrow style) Top of glass doors 180 Note: The EL402 is not recommended For use in doors with seal force For use in fire doors Note: EL 412 & EL 413 are replaced with EL 402 20 assaabloy.com.au

ABLOY EL402 Solenoid Lock 12 1.5 40 / 43 / 45 / 48 / 50 25 / 28 / 30 / 33 / 35 5.5x2 19 + 12-24 Vdc Common Locked Open black yellow blue red black yellow blue green 15 8 23.5 24-153.5 4 225 200 24 13 14.5 87 47.5 129.5 25 3 40 41.5 EL402 Solenoid Lock Technical Information Voltage Current Monitoring Environment Case/Cover 12-24 Vdc -10%/ +15% STAB 550mA (max) 240mA holding @12Vdc 270mA (max) 110mA holding @24Vdc Microswitch 0.4A 30V AC (deadlock status) Operational temperature range -20 C to +60 C High Purity zinc alloy Specification Statement The mortice lock must consist of High grade pure zinc alloy, the lock needs to have an adjustable backset 25,28,30,33 and 35mm. The latch bold must be no less than 14.5mm with complete double action trigger. The voltage must be variable between 12-24Vdc with tolerance of 10% up or down. The lock and unlocked status must be fully monitored by means of dry contacts. Forend Latchbolts 25mm 25, 28, 30, 33, 35mm (adjustable) Double action latch 14.5mm Ordering Information Product Description Part Number Door Clearance Cylinder Cabling Furniture Standard Finishes 3-5 mm ABLOY classic or ABLOY Disklock Pro Recommended cable: 18AWG (0.82mm2) cable runs up to 30m ABLOY Architectural Hardware Chrome plated forend, lock case yellow chrome plated ABLOY EL 402 Narrow Style Electric Mortice Solenoid Lock EL402 Cable 6m for EL402 EA211 Accessories Furniture (Narrow Style) 4/0645 21

ABLOY EL502 Solenoid Lock General Description ABLOY EL502 is typically used in the interior doors of business premises and educational buildings. The locks include a special double action bolt for quick and easy use and offer a cost-effective way of electric locking without compromising performance. The locks can be controlled by a variety of electrical impulse generating equipment such as card readers, keypads and timers. The locks can be connected to automatic swing door operators and are an excellent solution for access control systems. The new revolutionary adjustable backset feature offers unique flexibility that s never been available before. Because of its symmetrical trigger bolt, ABLOY EL502 can be used in double swing doors. The lock can always be opened mechanically by key or by thumb turn and the bolt deadlocks automatically when the door closes. Key Features Field selectable Fail Safe/ Fail Secure configuration Non Handed Symmetrical trigger bolt Visual Lock Status indicator Immediate release of Deadlocking Push or Pull operation Wide Operating Voltage 50mm Applications Offices Storage rooms Consulting rooms Note: The EL402 is not recommended; For use in doors with seal force For use in fire doors Note: EL 512 & EL 513 are replaced with EL502 22 assaabloy.com.au

ABLOY EL502 Solenoid Lock 102 50 6.5 75 29 12 19 30 30 203 225 105 147 10.5 8 15 25.5 37.5 + 12-24 Vdc - Common Locked Open black yellow blue red black yellow blue green 6.5 4 24 13 14.5 5.5 22 3 EL502 Solenoid Lock Technical Information Voltage Current Monitoring Environment Case/ Cover Forend Latchbolts Door Clearance Cylinder 12-24 Vdc -10%/ +15% STAB 12V Max 550 ma, Normal 240mA 24V Max 270mA, Normal 110mA Microswitch 0.4A 30V AC (Deadlock status) Operational temperature range -20 C to +60 C High Purity zinc alloy 22mm 50mm Double action latch 14.5mm 3-5 mm ABLOY classic or Abloy Disklock Pro Scandanavian oval type Specification Statement This mortice lock must consist of High grade pure zinc alloy, the lock needs to have a backset 50mm. The latch bold must be no less than 14.5mm with complete double action trigger. The voltage must be variable between 12-24Vdc with tolerance of 15% up or 10% down. The lock and unlocked status must be fully monitored by means of dry contacts. Ordering Information Product Description ABLOY EL 502 Electric mortice Solenoid Lock Cable 6m for EL502 Part Number EL502 EA211 Cabling Furniture Standard Finishes Recommended cable: 18AWG (0.82mm2) cable runs up to 30m ABLOY Architectural Hardware Chrome plated forend, lock case yellow chrome plated 23

ABLOY EL580 Solenoid Lock General Information ABLOY EL580 Locks are suitable for interior or exterior doors of business premises and the exterior doors of apartment buildings and detached houses. Abloy EL580 is suitable for use in exit doors as the inside handle is free for egress at all times. The locks are automatically deadlocked from the Exterior when the door is closed. The locks can be controlled by a variety of electrical impulse generating equipment, such as a card reader, keypad and timer. Key Features Interchangeable handing Changeable function of handle control Configurable fail safe or fail secure 12-24Vdc operating voltage Configuration of deadbolt either 14mm or 20mm Increased protection against manipulation Low current feature while continuous control Applications Offices Storage rooms Consulting rooms Fire Doors EL580 Solenoid Lock Technical Information Voltage Current Environment Case/ Cover Latchbolts Cylinder Cabling Furniture Standard Finishes 12-24Vdc -10%/ +15% STA 12V Max 550 ma, Normal 270mA 24V Max 240mA, Normal 110mA Operational temperature range -20 C to +60 C High purity Zinc alloy construction 50mm Bolt throw: 14mm or 20mm configurable Scandinavian Oval or Finnish type cylinder Recommended cable: 18AWG (0.82mm2) cable runs up to 30m ABLOY Architectural Hardware Chrome plated forend Specifier Statement The mortice lock must consist of High grade pure Zinc alloy The lock needs to have a backset of 50mm. The latch bolt must be configurable between 14-20mm. It also needs to be field selectable for the fail safe and fail secure configuration. The voltage must be variable between 12-24Vdc. The following parts need to be fully monitored; bolt position, handle down and REX by means of dry contacts. Ordering Information Product Description ABLOY EL580 Electric Mortise Solenoid Lock Cable 6m for EL580 24 assaabloy.com.au Part Number EL580 EA210

Electric Mortice Locks 25

ABLOY EL648 Motor Lock General Information The EL648 is a heavy duty motor lock with hook bolt for narrow style doors. They provide superior mechanical strength against physical attack. The EL648 is used in high security auxiliary lock in applications such as gates and exterior doors of industrial premises, shopping centres, business premises etc. The lock is especially suited for sliding doors as it can be installed in the door frame or the door leaf. EL648 is ideal for night locking that requires greater strength and security. The lock can be controlled by a variety of electrical impulse generating equipment such as a card reader, keypad or timer. This lock is suitable for use with sliding door operators. Key Features High security motor bolt. Lock case is connected with a separate control unit. 12-24Vdc operating voltage Configuration of deadbolt either 14mm or 20mm Increased protection against manipulation Striker plate includes door position magnet. Fully monitorered, bolt in/bolt out, door position manual operation Can configure lock in fail safe and fail secure (Backup card required to set the lock case to go to desired position in case of power failure) Note: Lock requires EA460 Control unit to operate. 26 assaabloy.com.au

ABLOY EL648 Motor Lock EL648 Motor Lock Technical Information Voltage Current Monitoring Environment Case/ Cover Latchbolts Cylinder Cabling Furniture Standard Finishes 24Vdc ± 15% stabilised Idle 70mA, Normal 150mA and Max 750mA Door position, Bolt Position Mechanical trigger Operational temperature range -25 C to +70 C High purity Zinc alloy construction 25mm or 35mm Bolt throw: 22mm Hook bolt Scandinavian oval type, Finnish type Recommended cable: 18AWG (0.82mm2) cable runs up to 30m ABLOY Architectural Hardware Chrome plated steel forend, yellow chrome, lacquered lock body. Specification Statement The mortice lock must consist of high grade pure zinc alloy. The bolt must be controlled by means of motor and the shape of the bolt must be in hook shape for added security. A separate controller needs to be connected to the lock to enable trigger and monitoring functions. The voltage must be variable between 12-24Vdc with tolerance of 15% up or down. The following parts need to be fully monitored; bolt position, door position by means of dry contacts. The lock must be suitable for internal and external use. Ordering Information Product Description ABLOY EL 648 Electric mortice Solenoid Lock Cable 6m for EL648 Strike plate with integrated magnet Accessories Control Unit Part Number EL648 EA214 EA300 EA460 Abloy Oy Wahlforssinkatu 20 Abloy Oy Wahlforssinkatu 20 P.O. Box 108 27

Power Transfer Lead Lockwood Power Transfer Cover LC8810 The LC8810 and LC8811 Power Transfer Lead Covers are designed to ensure unbroken transfer of wires between door and frame in electric locking situations. Features: Provides unbroken connection from controller to lock, for cable up to 8 mm diameter. Vandal-resistant chrome plated steel flexable. Completely concealed when the door is closed. Applications LC8810 The LC8810 is a shorter unit suitable for hinged doors which open to 90 (maximum of 120 ). LC8811 The LC8811 is designed for use on doors which open more than 120, or have a gap from pin hinge to door frame of more than 20 mm. NB. Not suitable for centrally pivoted doors. Standards and Compliance 4 Hour Successfully fire rated up to 4hrs on fire door assemblies in accordance with AS1905.1. 2005 (Part 1: Fire resistant door sets) 28 assaabloy.com.au

Power Transfer Lead LC8810 The LC8810 is a shorter unit suitable for hinged doors which open to 90 (maximum of 120 ). LC8811 The LC8811 is designed for use on doors which open more than 120, or have a gap from pin hinge to door frame of more than 20 mm. NB. Not suitable for centrally pivoted doors. 90 120 120 Door Frame Door Frame O12 323 299 258 O12 250 20 29 O10 O12 543 519 478 460 20 29 O10 O12 23.8 17 17 17 Ordering Information Product Description 323mm Power Transfer Cable 543mm Power Transfer Cable Part Number LC8810 LC8811 29

ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. ASSA ABLOY is represented in all major regions, in both mature and emerging markets, with leading positions in Australia, Europe and North America. As the world s leading lock group, ASSA ABLOY offers a more complete product range of door opening solutions than any other company on the market. Head Office ASSA ABLOY Australia Pty Limited 235 Huntingdale Road, Oakleigh Victoria, 3166 Australia 1300 LOCK UP (1300 562 587) info.au@assaabloy.com assaabloy.com.au AAA-CAT-069 0609 MS0458 ASSA ABLOY Australia Pty Limited ABN 90 086 451 907 2009