Model : LMHS-40 Please read this manual carefully before using the instrument Labnics Equipment

Similar documents
Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

OPERATING MANUAL. Mega 17R HIGH SPEED REFRIGERATED CENTRIFUGE HANIL SCIENCE INDUSTRIAL CO., LTD. PRINTED IN KOREA

Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment

Model : LHT-002A Please read this manual carefully before using the instrument Labnics Equipment

Operating Manual Cellspin

Operation Manual Supra R22

OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.

624R User s Manual. Compact Bench-Top Refrigerated Centrifuge

1236R User s Manual. Multi-Purpose, High Speed Centrifuge

BLOOD BANK REFRIGERATED CENTRIFUGE

1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd.

Shaking Incubators & Shakers

Multi-Purpose, High Speed Centrifuge 1248R/1580R User s Manual

Operating Manual. Multi Purpose Centrifuge Combi - 514R

CLEMENTS. Orbital 160 Benchtop Centrifuge. CEN V 50Hz. User Manual. Manual No. CEN Issue 4

Bio Lion Table Top Centrifuge XC-H165

L550 Table-Top Low-Speed Large Capacity Centrifuge

REFRIGERATED CENTRIFUGE. LRF-A2 Series

GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd

Bio Lion Table Top Centrifuge XC-L5

OPERATION MANUAL OM3121

BlueSpin Cryo. (Cat. No. BSD-CRYO)

Comfy Dry Bath Incubator

Centrifuge Operator / Service Manual

Instruction Manual for Table Top Refrigerated Centrifuge Z 36 HK

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

Heal Force Multipurpose Centrifugeses

CLEMENTS. Orbital 260 Benchtop Centrifuge. CEN V 50/60Hz. User Manual. Manual No. CEN Issue 5

Instruction Manual for Microliter Centrifuge Z 233 M-2

3 Liter Programmable Centrifuges

PrO-Ed Centrifuges. Centurion. C1015 Micro Prime Centrifuge. A Micro that offers: Education, Schools. C1015. (230V 50/60Hz). 1.C1015.

ISO-9001:2008 CENTRIFUGES CATALOG. Phone: Fax: Web: expotechusa.com


REFRIGERATED CENTRIFUGE. LRF-A1 Series

Instruction Manual for Table Top Centrifuge Z 366

Centrifuge. Model XC-2000 Operating Manual

PrO-ASTM Centrifuges. Centurion. C1015 Micro Prime Centrifuge. A Micro that offers: Oil testing. Petroleum testing, ASTM methods

XCM12 Mini-Centrifuge

EEMB CO., LTD. Specification

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

EEMB CO., LTD. Specification

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection

Multi-Purpose Rotor & Micro Rotor can be used in this convenient unit.

swing-out rotor MULTIBAS+

Centrifuge 5804 / 5804 R / 5810 / 5810 R. Instruction Manual Mode d'emploi succinct Instrucciones breves

SERVICE MANUAL SM3121

INSTRUCTION MANUAL FOR BENCH TOP CENTRIFUGE Z 200 A

PrO-Vet Centrifuges. Centurion. Veterinary, Equine & Cytology. Scientific Limited

EEMB CO., LTD. Specification

Max. 22,000 rpm / 48,700 xg, full 3 liter capacity

EEMB CO., LTD. Specification

Jouan B4i Multifunction Centrifuge Series

LCD Centrifuge MDCEN-302

OPERATING INSTRUCTIONS. Models SI-1400 through SI-1406

Rugged steel cabinet construction ensures quiet operation and long term reliability.

It s Your Turn. Eppendorf Centrifuge 5702, 5702 R and 5702 RH

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

HIGH SPEED REFRIGERATED CENTRIFUGE.

LABORATORY LOW SPEED CENTRIFUGE

PrO-Cyto Centrifuges 61

LABORATORY LOW SPEED REFRIGERATED CENTRIFUGE

Supra R30. High Speed Centrifuges. High Speed Centrifuge. Supra R30 / Supra R22 / Supra R17 / Supra R12

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL

Marin Control Digital

Neofuge 13/13R. Laboratory Centrifuge. Applications. Heal Force leads you to healthier life

Large Centrifuge. Continent 512R I Continent 512R Plus I Combi 514R I Combi 408. Large Centrifuge

Bench Centrifuge or Bench Centrifuge with Trolley

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Incubators. Incubators

Centrifuge. Model XC-1000 Operating Manual

1236R // 1248R LOW. capacity. HIGH G-Force High g-force 25,910 x g for fast centrifugation and efficient separation FAST HIGH

Instruction /Service Manual ALC Centrifuge Model PK130R

STANDARD OPERATING PROCEDURES SOP: 1002 PAGE: 1 of 5 REV: 0.0 DATE: 12/23/96

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Operation Manual. H6000 Series

Cassia Siamia BLOOD BANK REFRIGERATED CENTRIFUGE MP 6000 R. Technical Data (MP 6000 R)

Thermo Scientific Sorvall BP 8 and 16 Blood Banking Centrifuges. Proven productivity, built around you

HITACHI HIGH-SPEED REFRIGERATED CENTRIFUGES CR22G/CR21G

Instruction Manual for Compact Centrifuge Z 206 A

Instruction Manual for the Z 216 MK Refrigerated Microcentrifuge

INOCULATION TANKS 15 GALLON # GALLON #

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

Operation Manual Cole-Parmer MPR16 Multipurpose Refrigerated and MP16 Multipurpose Ambient Centrifuges Models , -25, -50, -55


Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

CRAFTAP 3 Brief Manual

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

Micro. Centrifuges.

Mini Centrifuge. Mini-13K/Mini-14K High Speed Centrifuge. Mini-6KC Centrifuge. Specification. Features: Two speed options. Quick release rotor

Maintenance Adjustments

MODEL 853VES Model 853VES Operator s Manual

2. INSTALLATION 1. MANUFACTURER IMPORTANT: AT LEAST 2 PEOPLE ARE REQUIRED TO LIFT THE CENTRIFUGE FROM THE PALLET AND PLACE IT ON THE BENCH.

High Speed Micro-Centrifuge User manual

Operating Manual. Operating Manual HYBRIDIZATION INCUBATOR. combi-h12 combi-d24 combi-v12 combi-sv12 combi-sv120

Simple design with easy-to-use features

DIGITAL TORQUE GAUGE MODEL BTGE-G

HERAEUS LABOFUGE 400 AND 400 R GENERAL PURPOSE CENTRIFUGES. Great value and functionality for routine work

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

Transcription:

HIGH SPEED CENTRIFUGES Instruction Manual Model : LMHS-40 Please read this manual carefully before using the instrument Labnics Equipment

Table of Content CHAPTER CONTENT PAGE No. 1 Introduction 1 1.1 Specifications 1 1.2 Caution 1 1.3 Safety Devices 2 2 Note for Installation 2 2.1 Location 2 2.2 Balance 3 2.3 Electrical Requirements 4 3 Parts Description 4 3.1 Control Panel 4 4 Operation Procedure 5 4.1 Standard Operation 5 4.2 Programmed Operation 5 5 Maintenance 7 7 Service Report 8

CHAPTER 1. INTRODUCTION : 1.1 Specifications:- Model No. Max. Speed Max. RCF Max. Capacity Timer Acceleration/Deceleration Display Power requirement Dimension(W x D x H) Weight LMHS-40 13,000 rpm 13,982 x g 20X1.5/2.0ml 99 minutes 59seconds 3 steps (Positive Action Break System) Digital type Speed, Time, Program, Breaking Steps Single Phase, 220V/50, 60Hz 270W x 355D x 280H mm 14 kg 1.2 Caution:- OVERSPEED Be sure that Rotor speed is not more than maximum rotation speed. Don't cross the maximum speed of rotor. When the rotor is subjected to relative centrifugal force over the allowed seal intensity, the destruction of rotor occurs because the shape of rotor is designed to be able to stand an external force in accordance with the allowed seal intensity of the rotor. IMBALANCE OF CYTO-UNIT Put the exact samples to be measured in each tube and load tubes symmetrically into the rotor, So that the tubes with equal volume are placed opposite to each other, otherwise serious turbulence will occur during rotation and the motor, rotor and the shaft gets damaged. Tubes should be symmetrically loaded on the rotor. - 1 -

If the numbers of tubes are not symmetrical, load another tube having same weight as other's have. 1.3 Safety Note:- Power On/Off An automatic circuit breaker protects the instrument circulation when it is overpowered in emergency situations, such as power surges, which could damage the unit. DOOR When door opens, the door limit switch by sensor makes the rotor be still. IMBALANCE & VIBRATION During rotation, if rotor is operated with imbalance over standard, motor also moves. In this case, the danger is detected by measuring the vibration of motor. With an alarm imbalance LED lit up and the rotation stops by preset deceleration level. Safety device as above keeps the instrument from an accident during operator's absence in Lab. CHAPTER 2. NOTE FOR INSTALLATION:- 2.1 Location:- Best Location The rotating instrument should be set on the flat and solid surface. In the case of setting the instrument at the incline surface, it is possible the shaft become bent by the heavy weight rotor because of a long time of rotation in inclining of the shaft and ground. - 2 -

AIR CIRCULATION For the circulation of air, the distance of at least 30 must be observed around the centrifuge during operation. Avoid to set it on the dusty place. TEMPERATURE & HUMIDITY The centrifuge which is controlled by a high-tech microprocessor is affected by the external conditions such as temperature or humidity. If a room temperature is extremely high by the direct ray of light or heater, or very low, the accuracy and reliance of instrument are reduced by errors of electronic parts. Even the high humidity makes the corrosion of rotor or parts. A proper temperature and humidity should be maintained accordingly. AVOID CORROSIVE GAS Place the centrifuge at the place which the corrosive gas can't occur. If there is sulfur dioxide or chlorine gas in atmosphere, it causes a corrosion of rotor and shaft, and cause great damage of metals. 2.2 Balance:- BALANCING The shaft has to be perpendicular to the ground. The shaft has to be perpendicular to the ground. At this time, a balancing gauge should be placed on the head part, mounting rotor on the instrument. If you measure a balancing gauge not on the shaft but on the main body of the instrument. It can't support the shaft to be rotated normally. - 3 -

2.3 ELECTRICAL REQUIREMENTS:- POWER REQUIREMENT The standard power requirements are a single phase and 220V but those are changeable depending on User's request. Therefore, plug in after checking the name plate located on the rear panel. Be sure not to be three phases. CHAPTER 3. PARTS DESCRIPTION:- 3.1 Control Panel:- SPEED SETTING REPRESENTED SPEED IN PROGRAM RECALL / SAVE INPUT IME, SPEED AND ETC., SAVE AND RECALL FOR REPEATED USE. RPM AND g-force in RCF. TIME DISPLAYED AND SET UP TO 9 HOURS 59 MINUTES 59 SECONDS TEMPERATURE REFRIGERATED AND INPUT TO ONE PLACE TO DECIMAL SPEED TIME TEMPERATURE PROGRAM MODE SPEED TIME TEMPERATURE xvsd STATUS START STOP OVER SPEED OVER TEMP. START STOP DOOR IMBALANCE BRAKE NUMERIC DOOR IMBALANCE LAMP FLASHES WHEN ABNORMALITY IN SYSTEM, TEMPERATURE, SPEED AND VIBRATION, AND STOP OPERATING WITH ALARM. 10 BREAK STEPS. SETTING PRESS NUMERICAL KEY TO INPUT SPEED, TIME, TEMPERATURE PROGRAM AND BRAKING. PRESS DOOR TO OPEN THE DOOR. LAMP FLASHES WHEN DOOR OPENS. - 4 -

CHAPTER 4. OPERATION PROCEDURE:- 4.1 Standard Operation- 1. Power Supply Turn on the main power switch at the back of the instrument. Turn "on" the keys switch located in front of the instrument. 2. Input desired setting parameters. Set the desired data for RPM, Time, Temp. Brake system Press the control button to change the data for speed, time, temperature and so on. Input desired parameters. Press "Enter" button after inputting the data. 3. Press start button to run the instrument Press "start" button to run the unit without changing any parameters such as rpm, time and temperature. The refrigeration system will run to calibrate temperature and the rotor will not run when the actual temperature is not in the temperature limit range. The centrifuge will start to decelerate when it reaches the time limit. Door will open when it stops and setting parameters will be displayed. Press the "stop" button to stop operation. 4.2 Programmed Function:- 1. Speed (RPM) :- When you set the desired speed, press the "RPM" key and set it by the up-down direction key. After that, press the "Enter" key. It is not possible to input higher speed than max.speed. This is to prevent the accident by overspeed. 2. RCF (x g) :- To calculate the Relative Centrifugal Force, it is made to calculate automatically RCF to Speed by using the Maximum Radius. RPM and RCF are calculated mutually so if RPM is input, RCF is calculated automatically and if reversely is same like above. It is like either during operation. SETTING- Press the RCF key and input the data by using up-down direction key. After that, press the Enter key. 3. Time :- The display range of time is 99mins and shows the 2 digits. The change of time counts down from setting time after running. Timer is proceeding by a unit of 1 minute and under 1 minute is used with a unit of second. - 5 -

SETTING- Press the "TIME" key. When Alarm sounds, it is possible to set. Input the desired time by using the up-down direction key. If you input the wrong data, Press "T" key and re-input the correct data. Press the "Enter" key and if the "Start" key is pressed, it starts to count down, and decelerate after over setting time. In one minute, it is showed as a second unit. Free run: You can use the "Free run" function for long time operation. For that, input the "0" in display of time and start to run. 4. Declaration : 3 Steps: High, Middle, Low -SETTING- Press the "Brake" key. Whenever the brake key is pressed, the lamp of H, M, L light on and the level of brake is changed. 5. Program Save : 10 Programs all can be saved and the range is 0 to 9. The data of RPM/Time, etc are saved in Program function. -SETTING- The desired data should be input by up-down key. If press the program, the lamp of "P" key lights on with sound and press "Enter". 6. Calling : The program saved between 0 to 9 can be called. -SETTING- Press the "Program" key to call the program saved before. When the lamp lights on "P" key with alarm, press the "P" again and turn off the lamp and alarm. After that, input the number to be called by up-down direction key and press the "Enter" key. At that time, the data of the pertinent program is showed. 7. Imbalance : When the rotor loses the balance of normal standard and vibrates seriously, Imbalance LED turns "ON" with the alarm and stops according to Decel Time as a pre-input. 8. DOOR:- To open the door, turn the dial on the right side of the instrument. When the door closes, "Door" lights off and when the door opens, the "Door" lights on. Close the door and press the "Start" key. Caution! : Don't open the door during the spinning. - 6 -

CHAPTER 5. MAINTENANCE:- This chapter explains how to keep your unit in good operating order. It includes instructions for cleaning, decontaminating and storing. This chapter also covers the cover interlock by pass. Care and cleaning: Keep your centrifuge cleans, to ensure good operation, and to extend it's life. Clean the sample chamber, rotor and lid at the end of each works day and immediately after any spill. To clean the chamber, use a damp sponge, warm water, and a mild liquid detergent, suitable for washing dishes by hand. Don't use caustic detergents or detergents that contain chlorine ions. These attack metals. Remove stubborn stains with a plastic scrub pad. Don't use steel wool, wire brushes, abrasives, or sandpaper. They create corrosion sites. Never pour water directly into the rotor chamber. Scrub the rotor's tube cavities with a stiff test tube brush that has end bristles and a non-metallic tip. Dry each part, after cleaning, with a clean, absorbent towel. If glass breakage occurs, remove all broken glass embed in the plastic or rubber accessories. Glass particles can come in contact with new glass tubes, creating pressure points that may results in breakage recurring. Glass particles, in the chamber, grind to a fine gray dust, during centrifugation. This dust can coat the inside of the centrifuge. Storage Store parts on a soft surface, to avoid damage. Rotors and other parts should be clean and dry. Store them opened to the air, not in a plastic bag, so that any residual moisture evaporates. Face the parts upward to avoid moisture retention in the cavities. - 7 -

SERVICE REPORT Customer s Address : Contact Person / Designation : Tel.No.: Fax No.: Weekly Off.: Dept.: Date From Time To System Configuration Model Serial No. Date : Status : OK SR. No. Not OK Installation Warranty Demonstration Maintenance Repairs Contract Application Calibration Billable Validation Courtesy Nature of Problem : Observation & Action Taken : Customer s Remarks : Parts Replaced : Parts Recommended / Action Required : Yes Service Engineer s Name & Signature No Requisition Number : Customer s Name, Signature, Date & Stamp Page Of -- 13 8 --

Labnics Equipment 43040 Christy St., Fremont, CA 94538 USA. Toll Free : (877) 620 9992 Tel. : (925) 271 4322 Fax : (925) 886 0400 Email : info@labnics.com Website : www.labnics.com