PRE Series 125 Amp Plugs and Sockets Increased Safety

Similar documents
PRE Series 63 Amp Plugs and Sockets Increased Safety

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety

ATX DPD Series Distribution Panelboards Flameproof

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

Unicode 2 Series Pre-Drilled Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Page Title Page Subtitle Page Subtitle Notes

JBDA and JBDF ECDA and ECDF Series Customized Enclosures Flameproof

Mechanical features. Spring-loaded elastic terminals: resist vibrations

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Panelboards & Motor Starters

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

FL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

EX-REPAIR AND MAINTENANCE RECEPTACLES

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plug and Socket Devices SolConeX 16 A Series 8570

ATX D Series Actuators, Pilot Lights, Contact Blocks, Switches and Accessories Flameproof

I Ex-Safety switches I

I Ex-safety switches I

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

A good connection. International approvals.

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Safety Switches Series 8537

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

Products for. Section

M-0. M-0... series control, monitoring and signalling devices. Ex e

10 Load and Motor Switchgear

I Ex-safety switches I

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

A good connection. International approvals.

DECONTACTOR. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

DNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A SILVER-NICKEL BUTT CONTACTS

Unused flameproof threads for cable glands have to be closed with certified plugs.

CCAI, CCAIF, CCAIF..H

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Linear fittings EVDL LED fitting - zones 21, & 22

Easy and safe installation

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

SWITCH SHOULD BE ON THE UPPER SIDE!

SWITCH SHOULD BE ON THE UPPER SIDE!

Linear fittings EVNL LED fitting - zones 2, & 22

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Ex eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

International approvals.

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

New products Ex Equipment 2015

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

YFC. Limit switch. Ex d. 24 operating head types

Floodlight LED Series 6525

Tank Inspection Lights Series 6122

Internationally approved.

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

11 Control Panels, Distribution Panels and Components

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

LED Linear Luminaire Series EXLUX 6402

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Junction boxes for control, monitoring and control panel Ex tb

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Floodlight LED Series 6525

Terminal Boxes in Stainless Steel SLS**.T

EXEL-L. Detail of the internal side. Transparent polycarbonate

Ex e, ia Junction boxes TNCN. Features

DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves

Load disconnect switch Series 8146/5-V11

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

Transcription:

s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 125 Amp s and Sockets - IK10 Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator sets Air conditioning Compressors Pumps For use in corrosive atmospheres and installations in Zones 1, and 2 and 21 and 22 of oil and gas industry, such as Refineries Chemical and petrochemical plants Pipelines Onshore and offshore drilling platforms Features Positive polarization: only ATX plugs of same style, number of poles and ampere rating may be used with these sockets. Interlocked 3-pole or 4-pole Ex de disconnecting on-load switch, with auxiliary early break contact capacity 2.5 mm 2 (0.004 in 2 ) maximum. is mechanically locked in socket when switch is ON. Switch operating handle can be padlocked in OFF position (max 4 padlocks). cannot be inserted or removed unless switch is in OFF position. Standard Materials Socket: 316L stainless steel Flap cover and plug: polyamide ATEX/IECEx Certifications and Compliances Certification Type PC125X Gas: Zones 1 and 2 Conforming to ATEX 94/9/CE: CE 0081 II 2 G ATEX/IEC Protection: Ex de IIC T-Rating: T6 for Ta +40 C (+104 F) and 5 for Ta 55 C (+131 F) Dust: Zones 21 and 22 Conforming to ATEX 94/9/CE: CE 0081 II 2 D ATEX/IEC Protection: Ex td A21 Surface Temperature: T90 C (T194 F) Ambient Temperature: -30 C to +55 C (-22 F to +131 F) CE Declaration of Conformity: 50218 ATEX Certificate: LCIE 99 ATEX 6031 IEC Certificate: LCIE Ex 99.017 Other Cetifications: GOST Ingress Protection (solid and liquid): Impact Resistance (shock): IK10 Ex Standards: EN/IEC 60079-0; 60079-1; 60079-7; 61241-0; 61241-1 Product Standards: EN/IEC 60309-1, 60309-2 Other Standards: EN/IEC 60529 (IP), 62262 (IK) Wall Mounting Socket NBR IEC Brazilian Certifications and Compliances Certification Type PC125X Gas: Zones 1 and 2 Dust: Zones 21 and 22 IEC Protection: ; T6 for -30 C Ta +40 C (-22 F Ta +104 F) and T5 for +40 C Ta +55 C (+104 F Ta +131 F) Ambient Temperature: -40 C to +55 C (-40 F to +131 F) Inmetro Certificate: BR230596 Ingress Protection (solid and liquid): Ex Standards: NBR IEC 60079-0; 60079-1; 60079-7 Other Standards: NBR IEC 60529 (IP) 1376

PRE Series 125 Amp s and Sockets - IK10 Wall Mounting Socket One M63 cable gland for unarmored cable Ø 36 to Ø 44 mm (Ø 1.42 to Ø 1.73 ) and one M25 blanking plug. Terminal capacity 120 mm 2 (0.186in 2 ). One integrated cable entry for unarmored flexible cable Ø 30 to Ø 48 mm (Ø 1.18 to Ø 1.89 ). Terminals capacity 50 mm 2 (0.078in 2 ). ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles 160 Amps Main Contacts Rated Insulation Voltage 690 Vac Rated Operating Voltage 690 Vac Rated Operating Current 125 Amp Rated Surge Voltage 8 KV Switching Capacity AC 21 A / AC 22 A 125 Amp 400 Volt to 690 Volt s and Receptacles AC 23 A 80 kw 400 Volt 110 kw 500 Volt 55 kw 690 Volt AC 3 90 kw 400 Volt 70 kw 500 Volt DC 21 125 Amp 440 Volt DC 22 100 Amp 440 Volt DC 23 63 Amp 440 Volt Auxiliary Contacts Rated Insulation Voltage 230 Volt Rated Operating Voltage 230 Volt Rated Operating Current 10 Amp Switching Capacity: AC 15 6 Amp 230 Volt Others Termination (flexible/solid) 120 mm 2 (0.007 in 2 ) 2 contacts connected in series per pole. 1377

s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 125 Amp s and Sockets - IK10 Catalog Numbering Guide IECEx Internationally Certified s and Receptacles PRE 4 12 R R A 3 T Series: PRE - PRE Series Zone 1, 2, 21 and 22 ATEX / IEC Certified Pin Configuration: 4-5 - 3P+N+E Amps: 12-125A Equipment: P - R - Receptacle (Wall Mounting) Voltage: R - 380-415 Vac N - 480-500 Vac R1-440 - 460 Vac 60 Hz N1-600 - 690 Vac Catalog Numbering Guide NBR IEC Brazilian Certified s and Receptacles Cable Type: A - Armored U - Unarmored Cable Entry Size: 3 - M32 4 - M40 5 - M50 6 - M63 Options: T - Through-wired N PRE 4 12 R R A 3 T NBR IEC Series: PRE - PRE Series Zone 1, 2, 21 and 22 NBR IEC Certified Amps: 12-125A Voltage: R - 380-415 Vac N - 480-500 Vac R1-440 - 460 Vac 60 Hz N1-600 - 690 Vac Cable Entry Size: 3 - M32 4 - M40 5 - M50 6 - M63 Pin Configuration: 4-5 - 3P+N+E Equipment: P - R - Receptacle (Wall Mounting) Cable Type: A - Armored U - Unarmored Options: T - Through-wired LV: Low Voltage Red Black Red 1 Black 1 380/415 Vac 480/500 Vac 440/460 Vac 600/690 Vac With one M25 plugged entry. 1378

PRE Series 125 Amp s and Sockets - IK10 Description Pin Configuration Weight kg (lb) Volume dm 3 (in 3 ) 380/415 Vac 50/60Hz Red Catalog Number IECEx 1.1 (0.04) 13.0 (793.31) PRE412PR NPRE412PR NBR 16.0 (0.63) 70.0 (4271.66) PRE412RRU6 NPRE412RRU6 16.0 (0.63) 70.0 (4271.66) PRE512RRU6 NPRE512RRU6 3P+N+E (1) 1.1 (0.04) 13.0 (793.31) PRE512PR NPRE512PR (1) 200/346 V 240/415 Vac 440/460 Vac 60 Hz Red 16.0 (0.63) 70.0 (4271.66) PRE412RR1U6 NPRE412RR1U6 1.1 (0.04) 13.0 (793.31) PRE412PR1 NPRE412PR1 16.0 (0.63) 70.0 (4271.66) PRE512RR1U6 NPRE512RR1U6 3P+N+E (2) 1.1 (0.04) 13.0 (793.31) PRE512PR1 NPRE512PR1 (2) 250/440 V 265/460 Vac 60 Hz 480/500 Vac Black 16.0 (0.63) 70.0 (4271.66) PRE412RNU6 NPRE412RNU6 ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles s and Receptacles 1.1 (0.04) 13.0 (793.31) PRE412PN NPRE412PN 16.0 (0.63) 70.0 (4271.66) PRE512RNU6 NPRE512RNU6 3P+N+E (3) 1.1 (0.04) 13.0 (793.31) PRE512PN NPRE512PN (3) 277/480 V 288/500 Vac 600/690 Vac Black 16.0 (0.63) 70.0 (4271.66) PRE412RN1U6 NPRE412RN1U6 1.1 (0.04) 13.0 (793.31) PRE412PN1 NPRE412PN1 16.0 (0.63) 70.0 (4271.66) PRE512RN1U6 NPRE512RN1U6 3P+N+E (4) 1.1 (0.04) 13.0 (793.31) PRE512PN1 NPRE512PN1 (4) 347/600 V 400/690 Vac 1379