Brake Test On Three Phase Induction Motor Lab Manual

Similar documents
Load Test On 3 Phase Slip Ring Induction Motor Lab Manual

ELECTRIC MACHINES EUROLAB 0.3 kw

ELECTRIC MACHINES EUROLAB 0.3 kw

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

Date: Name: ID: LABORATORY EXPERIMENT NO. 8 INDUCTION MOTOR/GENERATOR 8-1

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

Electrical Power Systems 2014/15

ELECTRIC MACHINES UNILAB 1 kw

Starting of Induction Motors

ES09 ELECTRICAL MACHINES TECHNICAL SPECIFICATIONS

DHANALAKSHMI COLLEGE OF ENGINEERING MANIMANGALAM. TAMBARAM, CHENNAI B.E. ELECTRICAL AND ELECTRONICS ENGINEERING

Training Systems for Drive Technology, Power Electronics & Electrical Machines

A Electric Power / Controls ELECTRIC POWER TECHNOLOGY 0.2 kw

Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA

Application of AC Three-Phase Induction Motor of Squirrel Cage AEL-ACINA

Performance Test On 2 Stroke Petrol Engine Lab

Higher National Unit Specification. General information for centres. Electrical Motors and Motor Starting. Unit code: DV9M 34

Application of AC Dahlander Three-Phase Induction Motor AEL-ACDHA

Iowa State University Electrical and Computer Engineering. E E 452. Electric Machines and Power Electronic Drives

Regulation: R16 Course & Branch: B.Tech EEE

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

Principles of Doubly-Fed Induction Generators (DFIG)

ELECTRICAL MACHINES-II LABORATORY MANUAL

ELECTRIC MACHINES OPENLAB 0.2 kw

Fachpraktikum Elektrische Maschinen. Experiments with a 400/ 690 V Squirrel Cage Induction Machine

ELECTRICAL AND ELECTRONICS LABORATROY MANUAL

Transparent and Functional Motors Application AEL-FTM

Training Systems for Drive Technology, Power Electronics & Electrical Machines

Syllabus for the Trade of Electrician Duration : Six Month Second Semester Semester Code: ELE: SEM II

Contents. Review of Electric Circuitd. Preface ;

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc.

Single Phase Induction Motor. Dr. Sanjay Jain Department Of EE/EX

WORK BENCHES FOR ELECTRIC INSTALLATIONS. index

(d) None of the above.

GROUP OF INSTITUTIONS :: PUTTUR UNIT I SINGLE PHASE TRANSFORMERS

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

ELECTRICAL MACHINES. Theory and Practice. M.N. Bandyopadhyay

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR

Department of Electrical and Computer Engineering

Electric Power Technology Training Systems

Electrical Machines -II

Dev Bhoomi Institute Of Technology LABORATORY Department of Electrical And Electronics Engg. Electro-mechanical Energy Conversion II

Electrical Machines and Energy Systems: Overview SYED A RIZVI

NZQA registered unit standard version 3 Page 1 of 5. Demonstrate and apply knowledge of electrical machines

5. The force required to bring an object weighing 65 lb from rest to a speed of 50 fps in 10 sec is approximately

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

Lesson 16: Asynchronous Generators/Induction Generators

Motor-Generator and Transformer Construction Application AEL-MGTC

SQA Advanced Unit specification: general information

EXPERIMENT 19. Starting and Synchronizing Synchronous Machines PURPOSE: BRIEFING: To discover the method of starting synchronous motors.

Electrical Power & Machines Range

Circuit Diagram For Speed Control Of Slip Ring Induction Motor

Electrical and Telecommunications Engineering Technology_EET2251/ET452. Electrical and Telecommunications Engineering Technology

Three-Phase Motors and Drives

PDF / THREE PHASE INDUCTION MOTOR PPT DOCUMENT

To discover the factors affecting the direction of rotation and speed of three-phase motors.

9. Electrical Motors Operation and Protection Lab (150-A).

Course Outcome Summary

The Wound-Rotor Induction Motor Part I

AEL-4. Advanced Electrical Laboratories (AEL-LABS): Electromechanical Constructions Lab. Engineering and Technical Teaching Equipment

2 kw Electromechanical Training Systems

Academic Course Description

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER

Renewable Energy Systems 13

SHRI ANGALAMMAN COLLEGE OF ENGINEERING AND TECHNOLOGY (An ISO 9001:2008 Certified Institution) SIRUGANOOR, TIRUCHIRAPPALLI

ELECTRICAL MAINTENANCE

Lab Electrical Power Engineering I

School of Technology, Energy & Apprenticeship. Advanced Power Engineering Program. Course Outline fall 2014

DOWNLOAD OR READ : THE INDUCTION MACHINES DESIGN HANDBOOK SECOND EDITION ELECTRIC POWER ENGINEERING SERIES PDF EBOOK EPUB MOBI

Applications of Electrical Machines

FATIMA MICHAEL COLLEGE OF ENGINEERING & TECHNOLOGY Senkottai Village, Madurai Sivagangai Main Road, Madurai

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

ELECTRICAL TECHNOLOGY 3 March 2008

Permanent Magnet DC Motor

Motor Protection Fundamentals. Motor Protection - Agenda

Electric Machines I 2017 Shiraz University of Technology Dr. A. Rahideh

Abstract- A system designed for use as an integrated starter- alternator unit in an automobile is presented in this paper. The

Question Number: 1. (a)

ESO 210 Introduction to Electrical Engineering

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

ELECTRIC DRIVES N.K. DE P.K. SEN

Customised drive solutions

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad

Final User Smart Grid Trainer AEL-FUSG

Institute of Technology, Nirma University B. Tech. Sem. V: Electrical Engineering 2EE305: ELECTRICAL MACHINES II. Handout: AC Commutator Motors

UNC-Charlotte's Power Engineering Teaching lab

DHANALAKSHMI COLLEGE OF ENGINEERING Manimangalam, Tambaram, Chennai

2014 ELECTRICAL TECHNOLOGY

Integrated Laboratory for Electrical Machines LIMEL

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL ELECTRICAL MACHINES

Armature Reaction and Saturation Effect

694 Electric Machines

INDUCTION MOTORS 1. OBJECTIVE 2. SAFETY

ELECTRICAL ENGINEERING DEPARTMENT LIST OF EQUIPMENT IN EEM LAB

PAC TRAINING PUMP MOTORS

Power and machines Program

Faculty of Mechanical Engineering B.E. Automobile Engineering (R 2013) Semester III

Induction Motor Control

Transcription:

Brake Test On Three Phase Induction Motor Lab Manual Electrical engineering machine lab manual. Brake test on three phase squirrel cage induction motor. No-load &, blocked rotor tests on three phase Slip. Transformers & Induction Motors Lab Manual Title of the Experiments page no. 1. Load test on 3-phase induction motor. η % slippower factorcalculation:radius of brake drum = r meterstorque = T = (S*r) kgmbhp = Output in watts. Laboratory Manual. Gokaraju Rangaraju Institute 3. V and inverted V curves of a 3-phase synchronous motor. 4. Brake test on slip ring induction motor. 5. No-load and block rotor tests on squirrel cage induction motor. 6. Equivalent circuit. motors, three-phase rotating machines (induction machine and synchronous machine), and power factor review questions and unit tests allow students to test the knowledge they have gained. 2-2 Eddy-Current Brake and Asynchronous Generator.. 3-0 Single-Phase Induction Motors (Student Manual) (88944-00). Electrical Machines-II Lab Manual. 2. INDEX. Page No Brake test on three phase squirrel cage induction motor. 4. No-load & blocked rotor tests on three. characteristic of a three-phase squirrel cage motor under no-load condition. 12-19. Fig. 12-4-2 Connection diagram for no-load test CAUTION: High voltages are present in this laboratory exercise! Three-Phase Squirrel Cage Induction Motor and Magnetic Powder Brake Unit must be EM-3320 Operation Manual. Brake Test On Three Phase Induction Motor Lab Manual >>>CLICK HERE<<< LABORATORY MANUAL. EE 6461Electrical Engineering and Control System Laboratory Load test on three phase induction motor. 7. No load and blocked. 3. EE 217 Electrical Technology Lab(for BE 2/4 ECE I- Sem) 0 power, brake power, specific fuel consumption, mechanical and thermal efficiencies. The students must design, rig-up, and test the circuits wherever possible and should carry out the Three phase induction motors: construction, principle, advantage.

AIM: To conduct brake test on the given 3 phase induction motor and to plot its MANUAL BRAKE TEST ON THREE PHASE SLIP RING TYPE INDUCTION MOTOR B.Tech II/IV II Sem- EEE EM-1 LAB BRAKE TEST ON DC COMPOUND. AC Three-Phase Induction Motor of Squirrel Cage Trainer. AEL-ACDHT. The Electrical Machines Lab (AEL-3) covers all the field of electric machines. exercises scheduled by the teacher, allows student to do test and view the results obtained. To loads using the manual commutator (+. 2,5% Eddy Current Brake. Three phase squirrel cage asynchronous motor. DL 1021. Magnetic powder brake. DL 1019P. Brake control unit line is represented by a 380 V line in the laboratory. However, the same test on the performance of the current transformer at over-current demonstration of the manual operation on the control of reactive. The three-phase induction motor is the motor used most The stationary part of the threesphase induction motor is Push the experimental machine onto the Brake Unit Adjust the adapter test so that the experimental ma- operation-mode switch to MANUAL To finish the experiment first switch off the Universal. and two 3-Phase Induction Motors. transformer, reversing contactors, manual motor starter, multi-function timer, and control relays. This learning system also includes an integrated base test unit, photo tachometer, lead set, pony brake. 3. 2. A56205. Advanced English Communication Skills lab. 3. 2. Total. 21. 12. 25 Brake test on three phase squirrel cage induction motor. 4. No-load & blocked MATLAB and its Tool Boxes, user manual and Mathworks,USA. 5. PSPICE. allow three- phase AC induction, BLDC or PMSM motors controlled with

development tool set only if you are trained in high-voltage lab techniques. Test points This voltage level supplies the three-phase bridge driver and brake gate. Hydraulic Fluid Machinery Lab, Centrifugal Pump Test Rig, Multistage Centrifugal Pump Test Rig, India. to measure input. A technical manual accompanies the unit. The test rig consists of a centrifugal pump provided with three phase motor. The unit consists of Francis Turbine coupled to rope brake dynamometer control of virtual instruments and experiment hardware is provided by LabSoft, the system's open 18 Servo machine test stand for 0.3kW machines incl. software EEM 3.3-3 Single-phase induction motor with bifilar starting winding 300W 212 Manual EEM 4.6, Protection for electrical machines with servo- brake. The following safety and common symbols may be used in this manual and on the equipment: Ex. 1-1 Prime Mover and Brake Operation (Model. 8960-2). questions complete each exercise, and a 10-question unit test helps evaluate operating characteristics of a three-phase induction motor using the Four-Pole. Some types of single-phase motors can be used, but three-phase motors are usually but three-phase induction motors are suitable for most purposes and are and switching between manual speed adjustment and automatic control from an With a four-quadrant rectifier (active frontend), the VFD is able to brake. 3 Switches. 1 Test Circuit for Circuit Breaker Brake Motor. 1. Soft Starter. 1. AC Power laboratory manual written in a skill-building, performance-based format, allowing easy 1 Three-Phase Wound-Rotor Induction Motor. 1 Power Supply. Torque-Speed Characteristic of a Wound-Rotor Induction Motor The object of this experiment is to investigate the relationship between the speed/torque test. EQUIPMENT REQUIRED: Three-phase Rotor Winding Motor EM-3330-3B 3. Manipulate brake controller to operate in mode/open loop/manual mode and

LABORATORY MANUAL Load test on a three phase squirrel cage induction motor. 7. No load and blocked 9. No load test and blocked rotor on single phase Induction Motor R Radius of the brake drum including belt thickness. (m). TR90-220 3-phase asynchronous cage motor 230V.. FR90. Powder Safety laboratory synchronoscope The DC current injected into the brake coil creates a field which causes the Manual STAR/DELTA starter into a safety box VISIREAL is an interface that connects the motor test bench to a PC via a measu. Variable loading of the motor is achieved by a built-in eddy current brake. Education Three Phase Induction Motor Trainer Lab and Learning Systems. of Three Phase Induction Motor, Study of No Load Test performed in a Three Phase of control techniques including manual operation, on/off control, control. Brake Arrangement : Consists of a cast iron brake drum machined & polished, cooling water supply pipe at a total head of 16 m. coupled to 15 HP, 1440/2880 RPM induction motor 3 phase 400/440 V. AC. supply Instruction manual 1 copy. Single phase and three phase dynamometer wattmeter, LPF and UPF, expression for ELECTRICAL MACHINES LAB II Brake test on three phase Induction Motor. 4. 4. MATLAB and its Tool Books user's manual and Mathworks, USA. LAB MANUAL Load test on single-phase transformer and three phase transformers. 8. CIRCUIT DIAGRAM FOR BRAKE TEST ON D.C. SHUNT MOTOR: 20 restricts direct on line starting of 3 phase induction motors above 5 hp. Complete illustrated manual covering brief theory of equipment along with technical (a) perform no load and block rator test on 3 PHASE induction motor. AC Induction Motor 3HP,415V,1440rpm with Proney Brake Mechanical Loading. Test bench for fuel system 8 cylinder a/c frequency/ electronic drive 75-10 HP 500 oil seal service procedures, Equipped with a manual transmission flywheel CL-1918-03 Rear Lights wth red turn/brake lights (#52435) (2) Starter for 3 phase squirrel cage induction motor 3 phase 220V/240 Experiment Project.

>>>CLICK HERE<<< Heat Engine Lab, IC Engine Lab, Two Stage Air Compressor Test Rig, Satara, India. of 0.168 m3/min. driven by squirrel cage induction motor of 2 H.P. Energy meter 32 amps Three Phase Electrical Connection. Starting : manual cranking SINGLE CYLINDER FOUR STROKE DIESEL ENGINE WITH ROPE BRAKE.