Leeson Single Phase Electric Motor characteristics and applications

Similar documents
Most home and business appliances operate on single-phase AC power. For this reason, singlephase AC motors are in widespread use.

Pretest Module 21 Unit 4 Single-Phase Motors

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

Motor Basics AGSM 325 Motors vs Engines

Single-Phase AC Induction Squirrel Cage Motors. Permanent Magnet Series Wound Shunt Wound Compound Wound Squirrel Cage. Induction.

ECET 211 Electric Machines & Controls Lecture 5-1 Electric Motors. Lecture 5-1 Electric Motors

5. The force required to bring an object weighing 65 lb from rest to a speed of 50 fps in 10 sec is approximately

Unit 34 Single-Phase Motors

14 Single- Phase A.C. Motors I

PAC TRAINING PUMP MOTORS

Single Phase Induction Motors

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

chapter6 Electrical machines and motors Unit 1 outcome 6

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

10. Starting Method for Induction Motors

Motor capacitors. Run Capacitors. Start Capacitors. Service notes. Two types 1. Run Capacitors 2. Start Capacitors

Special-Purpose Electric Machines

Principles of iers (intelligent

Chapter 3.2: Electric Motors

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc.

IT 318 SUPPLEMENTARY MATERIAL CHAPTER 4

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

MEBS Utilities services Department of Electrical & Electronic Engineering University of Hong Kong

Date: Name: ID: LABORATORY EXPERIMENT NO. 8 INDUCTION MOTOR/GENERATOR 8-1

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

Institute of Technology, Nirma University B. Tech. Sem. V: Electrical Engineering 2EE305: ELECTRICAL MACHINES II. Handout: AC Commutator Motors

AC MOTOR TYPES. DESCRIBE how torque is produced in a single-phase AC motor. EXPLAIN why an AC synchronous motor does not have starting torque.

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. 3/4 thru 25 Hp NEMA 56 thru 324T

IMPROVING MOTOR SYSTEM EFFICIENCY WITH HIGH EFFICIENCY BELT DRIVE SYSTEMS

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

Table 1. Lubrication Guide

V1000, A1000, E7, F7, G7,

Application Note : Comparative Motor Technologies

Chapter 2: AC Gearmotors and Motors

SECTION MOTOR REQUIREMENTS for HVAC

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

Hybrid Motor Technology to Achieve Efficiency Levels Beyond NEMA Premium

The Wound-Rotor Induction Motor Part I

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

Low Voltage Fuses For Motor Protection

Baldor Basics: Motors

ULTRACAPACITORS FOR UNINTERRUPTIBLE POWER SUPPLY (UPS)

AND LOAD PARAMETERS IMPORTANT MOTOR. Torque x Speed Constant. Horsepower= Mechanical Power Rating Expressed in either horsepower or watts

Motors- Basic principles. Expertise, performance, innovation

CradlePoint Vehicle Best Practices Installation Guide

AutomationDirect AC Motors Selection Overview

MOTORS, VOLTAGE, EFFICIENCY AND WIRING. A Deeper Understanding

UPS Ratings-Not so Apparent

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

Stator rheostat, Autotransformer Star to Delta starter and rotor resistance starter.

Doubly fed electric machine

Refrigeration and Air Conditioning Motor Types

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. Applications: Fans, blowers, machine tools, hoists, conveyors, pumps.

Solar Electric Systems. By Andy Karpinski

SERVICE SHOP NOTES. Use ohmmeter to check the resistance between the leads.

Induction motors advantages of induction motors squirrel cage motor

Starting of Induction Motors

Full Voltage Starting (Number of Starts):

Desensitizing Electric Motor Controls

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2

AC motors DR J (LSPM technology) / DRL / DRK / DRM

MOTOR INSTALLATION. Knowledge of proper installation techniques is vital to the effective operation of a motor

FASCO FACTS TIME-SAVING MOTOR REPLACEMENT TIPS

Installation, Operating & Maintenance Instructions

BELT-DRIVEN ALTERNATORS

Energy Independence & Securities Act Frequently Asked Questions

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

Shaft Grounding Rings. Protecting VFD Driven Motors from Bearing Currents

Drive Fundamentals. Motor Control Bootcamp May 15-18, Copyright 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC CO900H

SINGLE PHASE TEFC CAGE MOTORS

TYPES OF SINGLE PHASE INDUCTION MOTOR EBOOK

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

Single Phase Induction Motor. Dr. Sanjay Jain Department Of EE/EX

For motors controlled

Gener. Instructor: Center

Is Your Wiring System Safe and Energy Efficient?

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Design, Engineering, and Manufacturing of Motors for Electric Vehicle Applications

Primer. Stepper Motors

TOSVERT VF-S11. V/F control functions

RECOMMENDATIONS FOR USING FREQUENCY INVERTERS WITH POSITIVE DISPLACEMENT REFRIGERANT COMPRESSORS

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

Table of Contents Lesson One Lesson Two Lesson Three Lesson Four Lesson Five Lesson Six Lesson Seven Lesson Eight Lesson Nine Lesson Ten

Fundamentals of Motors

Selective Coordination

PRIMELINE. Induction Generator. Now Introducing Single Bearing Designs. Simple, Reliable Power For Wind or Engine Driven Applications

Some practical considerations

Understanding NEMA Motor Nameplates


ENERGY SAVING MAINS-FED PM SYNCHRONOUS MOTOR WITH INTEGRATED SOLID STATE STARTER

SELECTING A BRUSH-COMMUTATED DC MOTOR

FREQUENCY INVERTER INSTALLATION & USER GUIDE

PI Electrical Equipment - Course PI 30.2 MOTORS

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective

Crompton Greaves Limited

Transcription:

1 of 5 19/10/2006 5:49 PM Single-phase Electric Motors Characteristics & Applications by Kevin Heinecke, LEESON Electric Corporation Back to Web Merlin General Information Mechanical Electrical Metric IEC Maintenance Conversions/Formulas Warranty Reference Single-phase AC motors are as ubiquitous as they are useful -- serving as the prime power sources for a seemingly limitless array of small-horsepower applications in industry and in the home. Knowing how to apply the various types is the key to successful design. Where three-phase power is unavailable or impractical, it's single-phase motors to the rescue. Though they lack the higher efficiencies of their three-phase siblings, single-phase motors -- correctly sized and rated -- can last a lifetime with little maintenance. Occasionally a manufacturing defect can result in early motor failure. However, most failures result from inappropriate application. Pay careful attention to the application requirements before choosing a motor for replacement of a failed one or for a new design application. Not choosing the correct motor type and horsepower can cause repeated motor failure and equipment downtime. Obviously, you don't want to specify a motor too small for the application, thus resulting in electrical stresses that cause premature motor failure. But neither should you specify a motor too powerful -- either because of its power or its inherent design characteristics. It can also have serious effects. For example, a motor with high locked-rotor and breakdown torques can damage the equipment it drives. Also, running a motor at less than full rated load is inefficient, costing you money for power wasted. The key: First, size the motor to the application but, just as importantly, understand the characteristics of the major types of single-phase motors -- characteristics that go right to the heart of matching a motor to an application. In general, an ac polyphase squirrel-cage motor connected to a polyphase line will develop starting torque. A squirrel-cage motor connected to a single-phase line develops no starting torque, but having been started by some external means, it runs approximately like a polyphase motor. The many types of single-phase motors are distinguished by the means by which they are started.

2 of 5 19/10/2006 5:49 PM Split-phase The split phase motor, also called an induction-start/induction-run motor, is probably the simplest single-phase motor made for industrial use, though somewhat limited. It has two windings : a start and a main winding, Figure 1. The start winding is made with smaller gage wire and fewer turns relative to the main winding to create more resistance, thus putting the start winding's field at a different angle than that of the main winding, and causing the motor to rotate. The main winding, of heavier wire, keeps the motor running the rest of the time. A split-phase motor uses a switching mechanism that disconnects the start winding from the main winding when the motor comes up to about 75% of rated speed. In most cases, it is a centrifugal switch on the motor shaft. The split-phase motor's simple design makes it typically less expensive than other single-phase motor types made for industrial use. However, it also limits performance. Starting torques are low, typically 100% to 175% of rated load. Also, the motor develops high starting currents, approximately 700 to 1,000% of rated. Consequently, prolonged starting times cause the start winding to overheat and fail; so don't use this motor if you need high starting torques. Other split-phase motor characteristics: Maximum running torques range from 250 to 350% of normal. Plus, thermal protection is difficult because the high locked-rotor current relative

3 of 5 19/10/2006 5:49 PM to running current makes it tricky to find a protector with trip time fast enough to prevent start-winding burnout. And, these motors usually are designed for single voltage, limiting application flexibility. Good applications for split-phase motors include small grinders, small fans and blowers, and other low starting torque applications with power needs from 1/20 to 1/3 HP. Avoid any applications requiring high cycle rates or high torques. Capacitor start/induction run Here is a true wide-application, industrial-duty motor. Think of it as a split-phase motor, but with a beefed-up start winding that includes a capacitor in the circuit to provide a start "boost", Figure 2. Like the split-phase motor, the capacitor start motor also has a starting mechanism, either a mechanical or solid state electronic switch. This disconnects not only the start winding, but also the capacitor when the motor reaches about 75% of rated speed. Capacitor start/induction run motors have several advantages over split-phase motors. Since the capacitor is in series with the start circuit, it creates more starting torque, typically 200 to 400% of rated load. And the starting current, usually 450 to 575% of rated current, is much lower than the split-phase due to the larger wire in the start circuit. This allows higher cycle rates and reliable thermal protection. The cap-start/induction-run motor is more expensive than a comparable split phase design because of the additional cost of the start capacitor. But the application range is much wider because of higher starting torque and lower starting current. Use them on a wide range of belt-drive applications like small conveyors, large blowers and pumps, as well as many direct-drive or geared applications. These are the "workhorses" of general-purpose single-phase industrial motors. Permanent split capacitor A permanent split capacitor (PSC) motor, Figure 3, has neither a starting switch, nor a capacitor strictly for starting. Instead, it has a run-type capacitor permanently connected in series with the start winding. This makes the start winding an auxiliary winding once the motor reaches running speed. Because the run capacitor must be designed for continuous use, it cannot provide the starting boost of a starting capacitor. Typical starting torques of PSC motors are low, from 30 to 150% of rated load, so these motors are not for hard-to-start applications. However, unlike split-phase motors, PSC motors have low starting currents, usually less than 200% of rated load current, making them excellent for

4 of 5 19/10/2006 5:49 PM applications with high cycle rates. Breakdown torque varies depending on the design type and application, though it is typically somewhat lower than with a cap start motors. PSC motors have several advantages. They need no starting mechanism and so can be reversed easily. Designs can be easily altered for use with speed controllers. They can also be designed for optimum efficiency and high power factor at rated load. And they're considered to be the most reliable of the single phase motors, mostly because no starting switch is needed. Permanent split capacitor motors have a wide variety of applications depending on the design. These include fans, blowers with low starting torque needs, and intermittent cycling uses such as adjusting mechanisms, gate operators and garage door openers, many of which also need instant reversing. Capacitor start/capacitor run This type, Figure 4, combines the best of the capacitor-start/induction-run motor and the permanent split capacitor motor. It has a start-type capacitor in series with the auxiliary winding like the capacitor-start motor for high starting torque. And, like a PSC motor, it also has a run-type capacitor that is in series with the auxiliary winding after the start capacitor is switched out of the circuit. This allows high breakdown or overload torque. Another advantage of the capacitor-start/capacitor-run type motor: It can be designed for lower full-load currents and higher efficiency. Among other things, this means it operates at lower temperature than other single-phase motor types of comparable horsepower. The only disadvantage to a cap-start/cap-run motor is its higher price -- mostly the result of more capacitors, plus a starting switch. But it's a real powerhouse, able to handle applications too demanding for any other kind of single-phase motor. These include woodworking machinery, air compressors, high-pressure water pumps, vacuum pumps and other high torque applications requiring 1 to 10 hp. Shaded-pole Unlike all the previous types of single-phase motors discussed, shaded-pole motors have only one main winding and no start winding, Figure 5. Starting is by means of a design that rings a continuous copper loop around a small portion of each motor pole. This "shades" that portion of the pole, causing the magnetic field in the ringed area to lag the field in the unringed portion. The reaction of the two fields gets the shaft rotating.

5 of 5 19/10/2006 5:49 PM Because the shaded pole motor lacks a start winding, starting switch or capacitor, it is electrically simple and inexpensive. Plus, speed can be controlled merely by varying voltage, or through a multi-tap winding. Mechanically, shade-pole motor construction allows high-volume production. In fact, these are usually considered "disposable" motors, meaning they are much cheaper to replace than to repair. The shaded pole motor has many positive features, but it also has several disadvantages. Its low starting torque is typically 25 to 75% of full load torque. It is a high slip motor with running speed 7 to 10% below synchronous speed. Also, it is very inefficient, usually below 20%. Low initial cost suits shaded pole motors to low-horsepower or light-duty applications. Perhaps their largest use is in multi-speed fans for household use. But low torque, low efficiency, and less sturdy mechanical features make shaded-pole motors impractical for most industrial or commercial uses where higher cycle rates or continuous duty are the norm. The preceding information establishes guidelines for determining the proper motor type for your application. However, there are always special cases and applications in which it is acceptable to vary from these guidelines. Make it a point to check with your motor manufacturer for technical support in these areas. Capacitor Details Start Capacitor :The electrolytic start capacitor helps the motor achieve the most beneficial phase angles between start and main windings for the most locked-rotor torque per locked-rotor ampere. It is disconnected from the start circuit when the motor reaches about 75% of full-load speed. The start capacitor is designed for short-time duty. Extended application of voltage to the capacitor will cause permature failure, if not immediate destruction. Typical ratings for motor start capacitors range from 100 to 1,000 microfarad (uf) capacitance and 115 to 125 volts AC. However, special applications require 165 to 250-Vac capacitors, which are physically larger than capacitors of lower voltage rating for the same capacitance. Capacitance is a measure of how much charge a capacitor can store relative to the voltage applied. Run Capacitor : These are constructed similarly to start capacitors, except for the electrolyte. They are designed to serve continuously in the run circuit of a capacitor-start /capacitor-run motor. They withstand higher voltages, in the range of 250 to 370 Vac. They also have lower capacitance, usually less than 65 uf.