Modeling a Sprinkler System or a System With Nozzles

Similar documents
STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

Comparative study of the flow within water mist and sprinkler fire protection systems by means of CFD

ASSESSMENT REGARDING THE FLUID EQUATION. W = PV (WORK = PRESSURE x VOLUME) AS IT RELATES TO THE WORKING CAPABILITY OF PRESSURISED FLUIDS APPLIED IN

LX SERIES Low-Pressure Gas Compressors

LX-SERIES Low-Pressure Gas Compressors

Control Valves & Coil Packs

Case Study Balancing a System

AR No. # Low Pressure Irrigation

Familiarize yourself with the pressure loss phenomenon. The Discussion of this exercise covers the following point:

MOV MICRO OIL VALVES SELF-CLEANING

MERCER VALVE GENERAL INFORMATION THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

MAXIMUM PIPING OPERATING PRESSURE AS RECOMMENDED BY THE ASME PROCESS PIPING CODE Jacques Chaurette 2015

Troubleshooting Pumps in a System

Plastic pipe is now commonly used in irrigation and other pipelines. (acrylonitrile-butadiene-styrene), and PE (polyethylene)

CASH VALVE K SERIES BACK PRESSURE VALVES

3-way 1/2-2 Globe Valves

ABL FIRE PROTECTION 300 HOKE STREET RALEIGH, NC

Engineering & Design Data

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

TECHNICAL DATA SHEET. Medium Velocity Water Spray Nozzle. Page 1. Description. Technical and Environmental Specification. Installation & Maintenance

Motor-CAD End Winding Spray Cooling Model

599 Series Zone Valve Bodies:

Components of Hydronic Systems

Sleeve Valves Energy Dissipaters

USE OF MAZZEI INJECTORS IN PRESSURIZED SPRINKLER APPLICATIONS

Experiment (4): Flow measurement

The Discussion of this exercise covers the following points:

Extracting Tire Model Parameters From Test Data

CAMERON HYDRAULIC DATA

Quick Start User Guide

LX SERIES Low-Pressure Gas Compressors

3-way control valve in mixing and diverting design

700 LARGE SIZE SERIES

Specification: Industrial Mixing Center

Series DK Type DKV and DKM

High Pressure 2-way 2 1/2-6 Globe Valves

Washtenaw County DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Chapter 13: Application of Proportional Flow Control

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

TECHNICAL DATA. Q= C v P S

BERMAD Waterworks. BERMAD 700 Large Size Series. 700 Series. Features and Options. Model: 700-M5, 700-M6, 700-M5L

THERMOSETTER Recirculation thermal balancing valve

Installation, Operation and Maintenance Manual

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

Powermite 599 Series MT Series Terminal Unit Three-way Valves

TECHNICAL DATA 1-1/2 (dn40)

Series

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

TYPE D50 PRESSURE REDUCING VALVE REDUCING VALVE D50 PRESSURE. PRESSURES to 300 PSIG at 420 F

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

Hydraulic Drive Head Performance Curves For Prediction of Helical Pile Capacity

Assessing Your Sprinkler Irrigation System

Transient Effects on Dynamic Torque for Butterfly Valves

MERCER VALVE SERIES Flanged THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

TECHNICAL DATA. Table Standard Materials

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Model DDX Deluge Valve 8 (200mm) Features

Contents. Pressure measurement technology Pressure calibrators 18 Exercises 19-20

Model 5400 / 5450 Control Valve

VFC-5 to VFC-500 FLO-COATER

T205 Series Tank Blanketing Regulators

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

599 Series Zone Valve Bodies:

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Features 1. Differential Latch-type, lightweight, dependable

MERCER VALVE 1400 SERIES THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

OBSOLETE DESIGN DATA. 3", 4", 6" and 8" CONCENTRATE CONTROLLERS

Thermostatic Control Valve

Pipe Fitting Friction Calculation Can Be Calculated Based

Sprayer. Agricultural. Calibration

MODEL: HV-AS & HV-BS TECHNICAL DATA : MAINTENANCE DESCRIPTION PRESSURE (3/4 NPT OPTIONAL)

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Characterized Port -CP Three-Way Ball Valves

MODELS F822 THRU F834

Fisher DFA Variable Geometry Desuperheater

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442.

DP143, DP143G and DP143H. Pilot Operated Pressure Reducing Valves with Cast Steel Bodies

To ensure proper installation, digital pictures with contact information to before startup.

TECHNICAL DATA. mixture, with a freeze temperature

Baumann Series Sanitary Regulators

AutoFilt RF3 Automatic Self-Cleaning Filter

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

TECHNICAL INSTRUCTIONS Heavy Duty Bronze Series

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

MERCER VALVE GENERAL INFORMATION

Thermostatic Control Valve

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

394C. Series 6400/6600. Safety Valves for Power Boiler Service

Capacity Charts. Direct Spring Acting Safety Relief Valves for Air, Gas, Liquid, and Steam Service

In order to discuss powerplants in any depth, it is essential to understand the concepts of POWER and TORQUE.

Performance of VAV Parallel Fan-Powered Terminal Units: Experimental Results and Models

Suction Diffusers. Applications PROTECTION PUMP. Pressures to 790 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZE RANGES RATINGS

Flowrite 599 Series Two-Way Valves 1/2 to 2-inch Bronze Body

11.02 Mechanical-T Bolted Branch Outlets

Operability and Performance Analysis of Various Control Valves

XP-300 Series Sprinklers Installation & Service Instructions

Transcription:

This article is also available for viewing online at http://kb.eng-software.com/questions/270/ Modeling a Sprinkler System or a System With Nozzles There are several ways to model a sprinkler system or a system with nozzles in PIPE-FLO. Sprinklers, fire suppression nozzles, and spray nozzles are typically characterized by a Discharge Coefficient which some nozzle manufacturers represent with the letter K, used in the following equation: This conflicts with the way PIPE-FLO uses the letter K, which is used to represent the Resistance Coefficient of valves and fittings. This inconsistent use of nomenclature has resulted in confusion when modeling a spray nozzle within PIPE-FLO. For a spray nozzle, increasing the value of the discharge coefficient increases the flow rate through the nozzle, but when using the resistance coefficient to describe a spray nozzle, increasing the resistant coefficient decreases the flow rate through the nozzle. The nozzle discharge coefficient is also equivalent to the flow coefficient (Cv) when used with water at 60 degf (SG=1.0), using U.S. units (N 1 =1.0), and no piping fittings (F p =1.0), as shown in the following equation for Cv for a control valve: When using the Darcy Weisbach calculation method, the nozzle can be modeled as a: 1. component 2. fixed Cv 3. equivalent fixed resistance (K) fitting in a pipeline When using the Hazen Williams calculation method, the nozzle should be modeled as a component with a curve. The fixed Cv and fixed resistance cannot be used because dp is calculated using Q 2 for these methods, whereas Hazen Williams uses Q 1.85 to calculate the head loss and dp. Consider the following graph given by a nozzle manufacturer for a range of available nozzles: kb.eng-software.com/questions/270/ print 1/7

Nozzle as a Component (Darcy or Hazen-Williams Method) To model the nozzle as a component with a K nozzle =7.2, several data points can be generated for the component dialog box data table using the nozzle equation, Q=K(dP) 0.5 as shown below (these values were calculated in Excel). The data points can be confirmed on the manufacturer's graph. The nozzle component has an outlet pipe of very short length (0.001 ft) with a spray boundary pressure of 0 psig. Now PIPE-FLO will use the component data to interpolate between values for any flow rate that is calculated for the component, as shown below for the component with a flow of 45 gpm. The calculated dp can be compared to the manufacturer's graph at 45 gpm. kb.eng-software.com/questions/270/ print 2/7

Nozzle as a Fixed Cv (Darcy Method ONLY) The nozzle can also be modeled as a fixed Cv installed as a fitting in a pipeline of very short length, as shown below. Again, as the flow rate changes, the correct differential pressure will be calculated, as shown below and confirmed in the manufacturer's graph above. Conversely, as the inlet pressure of the nozzle changes, the correct flow rate will be calculated. Nozzle as a Fixed K (resistance) (Darcy Method ONLY) Modeling the nozzle as a fixed resistance (K) requires the use of the dp calculator and taking a data point off the graph or calculating the data point. In the dialog box below, a data point of 50.9 gpm and 50 psig is used to calculate the resistance coefficient, K=23266. kb.eng-software.com/questions/270/ print 3/7

The use of the fixed K can be confirmed by comparing another point on the manufacturer's curve, in this case at 55 gpm, PIPE-FLO calculates a dp of 58.38 psi. This corresponds to the value on the graph. Modeling a Fire Suppression System Modeling nozzles as components can be seen in the following fire suppression system in which PIPE-FLO is used to size the fire pump to ensure at least 20 gpm at each nozzle (discharge coefficient = 3.2 from the manufacturer's graph above). Each nozzle is modeled as a component using calculated data points from the nozzle equation. The Darcy calculation method is used. The figure below shows a scenario in which the entire system is activated on both floors. The pump was selected based on a design point of 500 gpm and 110 ft of head. kb.eng-software.com/questions/270/ print 4/7

Below is the same system except that the nozzles are modeled as fixed Cv fittings in the pipeline. Flow rates are caparable to the system above, with the exception of a slight variation due to the linear interpolation method used in the components above. kb.eng-software.com/questions/270/ print 5/7

Here is the same system using components to model the nozzles and using the Hazen-Williams method to calculate the head loss. In this situation the flow rates and dp are comparable to the two models above, but this is highly dependent on the Hazen- Williams "C" factor, the pipe sizes, and the use of water at 60 degf. kb.eng-software.com/questions/270/ print 6/7

kb.eng-software.com/questions/270/ print 7/7