QMXTubular Mixed Flow Product Guide 1

Similar documents
Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Inline and Roof Mounted Fans

Fixed Pitch Vane Axial Fan

Tubular Centrifugal Fans

Centrifugal Plenum Fan

Tube Axial Fan Page Specifications & Dimension Data Performance Data

TUBULAR CENTRIFUGAL INLINE FANS

Square Inline Fans with Multi-Directional Discharge

Mixed Flow Inline Fan, Model MFSI

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

LORENIZED Fan Finish. The COOK Powder Coating Process. Free design tools. Culture of Quality. Independent Certification. Download

VANEAXIAL & TUBEAXIAL FANS

Inline Fans [ 14 ] * UL is optional and must be specified.

Tube Axial Inline Fans

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

High Performance Axial Fans

Air Moving Solutions. low pressure mixed flow fans. QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat)

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Roof Upblast and Sidewall Exhaust

LOW PRESSURE MIXED FLOW FANS

Roof Upblast and Sidewall Exhaust

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Air Moving Solutions. axifan adjustable blade vaneaxial fans

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Centrifugal Utility Fans - SFD/SFB

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications...

Twin City Fan & Blower

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

SECTION CENTRIFUGAL HVAC FANS

& 12" 96" / TABD CATALOG

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Twin City Fan & Blower

SECTION AXIAL HVAC FANS

LINEA Low Discharge Roof Exhausters

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

AXIFAN VANEAXIAL FANS

DESIGN GUIDELINES FANS PAGE 1 of 7

Bulletin VX05 VANEAXIAL FANS

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Turning Air Into Solutions. AXIFAN VANEAXIAL & TUBEAXIAL FANS TCVS/TCTS TCVSSH/TCTSSH

SECTION HVAC POWER VENTILATORS

Centrifugal Filtered Supply Roof Blowers

Defining Innovation. mixed flow fans. TYPE QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) QFE (Fume Hood Exhaust)

2. Backward inclined / backward curved centrifugal wheel fans. 3. Axial / backward curved mixed flow impeller bifurcated fans.

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MIXED FLOW FANS QSL QSLR QSLSH CATALOG 1060 MARCH 2017

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

forward curved inline duct blowers

Centrifugal Spun Aluminum Products

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

Vane Axial Fans Models VAB and VAD. Belt and Direct Drive

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Centrifugal Fans - M41

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

Laboratory Exhaust Systems

EXHAUST FANS CUD & CUB UPBLAST FANS

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

Turning Air Into Solutions. PLUG FANS TYPE BCPL

EcoWatt Products. Advancing Ventilation

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

The Industrial Choice. Model AMX MIXED FLOW FANS. Model AMX (Standard) Model AMXR (Restaurant) Model AMXSH (Smoke & Heat)

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

Energy Recovery Laboratory Exhaust

Industry best 5 year fan housing warranty, 1 year motor warranty

Twin City Fan & Blower

Centrifugal, Tubular Inline Fan, Model CIR

HIGH VELOCITY FUME EXHAUST FANS

Type VA Vanax Fans. Models VA, VAD, & VAB

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Filtered Kitchen Supply Packaged Ventilator

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Industry best 5 year fan housing warranty, 1 year motor warranty

Defining Innovation. backward curved FANs

Centrifugal Fans - Series 21 & 41

Propeller Upblast Roof Fans

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

Filtered Air Supply Package Page

ROUND CENTREX Centrifugal Inline Fans

Industrial Mini Vent Sets

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Centrifugal Spun Aluminum Products

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Industry best 5 year fan housing warranty, 1 year motor warranty

Centrifugal Spun Aluminum Products

Transcription:

QMXTubular Mixed Flow Product Guide 1

INTRODUCTION QMX has a wide range of benefits. These features make QMX your ideal solution when low sound, high efficiency or compact size are required. DESIGNED FOR supply, exhaust or return air movement applications EQUIPPED WITH the Cook Contour axialcentrifugal hybrid impeller EXTRA BENEFITS DESIGNED WITH the latest Computational Fluid Dynamics (CFD) and Finite Element Analysis (FEA) softwares PERFORMANCE RANGE 500-179,000 CFM 18+ REDUCED fan size, motor horsepower and fan sound levels when compared to other inline fans OFFERED IN 18 SIZES ranging from 90 to 600 QMX utilizes a relatively large diameter wheel in a small housing, which results in slower wheel speeds and quieter operation. UL/cUL 705 Listing is standard on all QMX models. QMX's Cook Contour mixed-flow wheel combines the high airflow features of an axial fan with the pressure capabilities and static efficiency of a centrifugal blower. STATIC PRESSURES up to 15 w.g. CHOOSE FROM three different wheel types: QMX, QMXHP, QMXXP QMX can be 2 3 fan sizes smaller than an equivalent performing tubular inline blower, resulting in significant space and cost savings. 2

ENGINEERING SOFTWARE The QMX was designed using the latest Computational Fluid Dynamics (CFD) software. CFD helps cultivate rapid, highly efficient and vastly innovative product design. APPLICATION ADVANCEMENTS CFD and FEA software allows our engineers to fully optimize our fan design to a targeted design criteria. Physical prototypes verify the performance and durability of the design. Designing with this process results the quietest and most efficient fans in the industry. 3

MIXED-FLOW ADVANTAGES The Cook Contour mixed-flow wheel produces a highly efficient, quiet and compact tubular inline fan. Proper airflow is crucial for high fan efficiency. Let's see how it works. These illustrations show cross sections of typical mixed-flow, tubular centrifugal and axial fans. Flow lines developed with CFD software and added to the illustrations show the different air patterns between each type of fan. Areas in red indicate high turbulence zones that result in loss of efficiency and excess noise. MIXED-FLOW AXIAL CENTRIFUGAL Two gentle changes in airflow direction Lower RPM required for equal flow and pressure Highest static efficiency of inline fans Smallest diameter with equal performance Lowest sound levels of equal size units Large inlet opening yields low inlet velocities Design allows for close wall proximities when used in built-up air handlers. Airflow straight through with no direction changes High airflow volume in a relatively small diameter May require inlet bell and outlet cone Less efficient at high pressures 4 Two abrupt 90 changes in airflow directions High pressure capability Higher RPM required for equal flow and pressure Larger size required for equal performance

PERFORMANCE COMPARISON Efficiency 80 70 60 50 40 30 Compare the QMX static efficiency, horsepower, and sound power performance to our CIC and VAB units to see why the QMX is the superior choice. STATIC EFFICIENCY HORSEPOWER SOUND POWER 12,000 17,000 22,000 CFM Horsepower *270 QMX vs comparably sized CIC (tublar centrifugal) and VAB (vane axial) fans. PERFORMANCE ADVANTAGES 25 20 15 10 5 0 70 12,000 17,000 22,000 12,000 17,000 22,000 CFM Static Efficiency Horsepower Sound Power (LwA) Performance Size* QMX Mixed Flow CIC Tubular Centrifugal VAB Vane Axial QMX Mixed Flow CIC Tubular Centrifugal VAB Vane Axial QMX Mixed Flow CIC Tubular Centrifugal VAB Vane Axial 10,000 CFM @ 1" w.g. 225 QMX 55% 31% 49% 2.84 5.14 3.02 83 93 89 10,000 CFM @ 4" w.g. 225 QMXHP 66% 57% 53% 9.57 11.00 11.30 91 96 102 10,000 CFM @ 7" w.g. 225 QMXXP 69% 63% - 16.00 17.50-91 100-40,000 CFM @ 3" w.g. 445 QMX 72% 51% 62% 26.40 36.60 29.10 88 98 100 40,000 CFM @ 6" w.g. 445 QMXHP 74% 59% 48% 51.10 63.40 75.20 94 101 111 40,000 CFM @ 9" w.g. 445 QMXXP 64% 62% - 87.80 91.00-101 105 - *Size based on closest comparable housing diameter. 5 LwA 110 100 90 80 CFM KEY: CIC VAB QMX

PERFORMANCE COMPARISON The QMX, QMXHP and QMXXP are each designed for a specific performance range. The curves chart below illustrates typical performance limits of the QMX, QMXHP and QMXXP. SP (incw) 20.00 16.00 12.00 8.00 QMXXP QMXHP Optimized for typical Class-3 static pressures of 8" to 15" w.g. Airflow capacity up to 179,000 CFM Utilizes a true airfoil blade to achieve maximum efficiency at highest static pressures Optimized for typical Class-2 static pressures of 4" to 8" w.g. Airflow capacity up to 118,000 CFM Utilizes a true airfoil blade to achieve maximum efficiency at higher static pressures 4.00 0.00 5000 10000 15000 20000 25000 35000 Volume (CFM) 6 QMX Optimized for typical Class-1 static pressures of 0.5" to 4" w.g. Airflow capacity up to 124,000 CFM Utilizes a contoured, single thickness blade with 3D curvature to achieve maximum airflow and efficiency while maintaining low sound levels

LEVEL COMPARISON The QMX is available in three construction levels. Each level has been designed to meet various specific requirements. See below for key differences between levels. PRESSURE RANGE LEVEL 1 LEVEL 2 LEVEL 3 Up to 4 Up to 8 Up to 15 PRICE $ $$ $$$ WEIGHT AVAILABLE ARRANGEMENTS 9 3, 4, 9 9, 4 AVAILABLE SIZES 165 600 90 600 150 600 WHEEL OPTIONS QMX QMXHP QMX QMXHP QMXXP QMXXP 7

LEVEL ONE FEATURES The Level One standard construction features are shown below on the QMXHP Arrangement 9. INLET VIEW Sealed Belt Guard Adjustable Motor Plate Shaft Seal OUTLET VIEW Air-Handling Quality Ball or Roller Bearings Lifting Lugs Inlet Duct Collar Straightening Vanes Extended Lube Lines Outlet Duct Collar Aerodynamic Inlet Cone High Efficiency Mixed Flow Wheel Continuously Welded Housing Lorenized Powder Coating 8 Adjustable Horizontal Mounting Feet

LEVEL TWO FEATURES The Level Two standard construction features are shown below on the QMX Arrangement 9. INLET VIEW OUTLET VIEW Sealed Belt Guard Adjustable Motor Plate Shaft Seal Air-Handling Quality Ball or Roller Bearings Lifting Lugs Inlet Duct Collar Straightening Vanes Extended Lube Lines Outlet Duct Collar Aerodynamic Inlet Cone High Efficiency Mixed Flow Wheel Continuously Welded Housing Lorenized Powder Coating Adjustable Horizontal Mounting Base 9

LEVEL THREE FEATURES The Level Three standard construction features are shown below on the QMXXP Arrangement 9. INLET VIEW OUTLET VIEW Sealed Belt Guard Heavy Duty Adjustable Motor Plate Shaft Seal Air-Handling Quality Ball or Roller Bearings Lifting Lugs Inlet Duct Collar Full Length Straightening Vanes Outlet Duct Collar Extended Lube Lines Aerodynamic Inlet Cone High Efficiency Mixed Flow Wheel Continuously Welded Housing Lorenized Powder Coating Adjustable Horizontal Mounting Base 10

ADDITIONAL ARRANGEMENTS The QMX/QMXHP Arrangements 3 and 4 shown below offer additional construction features. The Arrangement 4 is also available in a Dual Door version and a Bifurcated version. ARRANGEMENT 3 ARRANGEMENT 4 Sealed Belt Guard Inlet Duct Collar Continuously Welded Housing Straightening Vanes Continuously Welded Housing Straightening Vanes Lifting Lugs Inlet Duct Collar Extended Lube Lines Outlet Duct Collar Lorenized Powder Coating Outlet Duct Collar Adjustable Horizontal Mounting Base Adjustable Horizontal Mounting Base Fixed Motor Plate 11

ADDITIONAL CONFIGURATIONS The QMX models QMXU/QMXHPU AND QMXE/QMXS/ QMXHPE/QMXHPS shown below offer additional construction features for mixed-flow blowers. QMXU UPBLAST EXHAUST Lifting Lugs QMXE/QMXS EXHAUST/SUPPLY (QMXS shown) Butterfly Damper Continuously Welded Steel Windband Birdscreen Spun Aluminum Top Cap Motor Cover Integral Curb Cap Motor Cover Integral Curb Cap 12

QMX ACCESSORIES Beyond the QMX Standard Construction Features, Cook offers accessories to fit your custom air-movement requirements and/or preferences. Flanged Outlet Outlet Safety Guard Outlet Companion Flange ARRANGEMENT 9 Details on next page. Flanged Inlet Access Door Inlet Safety Guard Belt Tunnel Motor Cover External IVD Mounting Rail Inlet Companion Flange Isolator 13

ACCESSORIES EXPLAINED Beyond the QMX Standard Construction Features, Cook offers accessories to fit your custom air-movement requirements and/or preferences. ACCESS DOOR An access door is available in a bolted or hinged configuration. The access door provides access to the wheel for cleaning and inspection. It is standard on QMXU, QMXHPU, QMXE, QMXS, QMXHPE and QMXHPS on all Arrangement 3 units. ENCLOSED BELT TUNNEL The belt tunnel encloses the belts and isolates the belts and drives from the air stream. Cataloged performance is based on fans without belt tunnel. The belt tunnel is standard on QMXE, QMXHPE, QMXS, QMXHPS, QMXU and QMXHPU. EXTERNAL IVD An external inlet vane damper, IVD, is used to provide precise air volume control while maintaining maximum efficiency and stable operation at reduced load conditions. The external IVD also requires the flanged inlet option. FLANGED INLET/OUTLET Flanged inlet/outlet connections are available for applications requiring flanged duct connections. INLET/OUTLET COMPANION FLANGE Inlet/outlet companion flanges are available for use in conjunction with the optional flanged inlet/outlet. The companion flanges are attached to the adjacent ductwork to provide an exact mate to the flanged connection on the fan. INLET/OUTLET SAFETY GUARDS Inlet/Outlet safety guards protect personnel and prevent debris from entering the fan. Safety guards are constructed of either expanded metal or wound spiral rings and are factory installed. (Discharge Guard on QMXU) MOTOR COVER The motor cover encloses the motor and shields the motor from dirt, dust, moisture and other contaminants. Standard on QMXU, QMXHPU, QMXE, QMXS, QMXHPE and QMXHPS. MOUNTING RAILS/BASE Mounting rails or base are available for applications where the motor center of gravity is offset with respect to the fan center of gravity. Additional accessories not pictured. DRAIN A drain coupling can be attached to the bottom of housing. The coupling is continuously welded to the housing. A drain is standard on QMXU and QMXHPU. EXTENDED LIFE BEARINGS Extended life bearings provide L10 life in excess of 200,000 hours. Ratings are calculated per AFBMA Standards and based on maximum operating conditions. FLEXIBLE DUCT CONNECTOR The flexible duct connector provides a flexible connection between the fan and the attached ductwork. The connector is constructed of reinforced neoprene fabric and aluminum bands. NOT to be used for UL762 or smoke control units or temperatures in excess of 250 F. ROOF CURB Roof curbs are used as roof support structures for fans and ventilators. They are available for flat, pitched and ridged roofs with or without insulation. RUB RING The aluminum rub ring lines the hole through which the shaft passes to prevent the shaft and wheel from contacting the inner drum of the QMX. SHAFT SEAL The shaft seal reduces air leakage around fan shaft in high pressure applications. It is constructed of aluminum and aramid fiber/nbd gasket material. Requires belt tunnel. ALUMINUM WHEEL An aluminum wheel can be substituted in applications where spark resistance or reduced starting torque is necessary. NOT to be used in smoke control applications. MOTOR HEAT SHIELD The heat shield is a foil backed insulation placed between the outer housing and motor to protect the motor from elevated airstream temperatures. METAL LUBE LINES Extended lube lines are available in copper or Stainless Steel. 14

QMX ISOLATORS Cook offers six types of isolators which reduce vibration transmission from equipment to building structure. HOUSED SPRING floor mounted FREE STANDING SPRING floor mounted RUBBER-IN-SHEAR ceiling mounted RESTRAINED SPRING floor mounted SPRING ceiling mounted RUBBER-IN-SHEAR floor mounted 15

ACCESSORY PACKAGES Cook also offers two accessory packages, Spark Resistant and High Temperature. These provide a quick and simplified purchasing process. SPARK-RESISTANT PACKAGE HIGH TEMP PACKAGE Type Description Included Options A B C All parts of the Air Moving Device (AMD) in contact with the air or gas being handled shall be made of non-ferrous material. The AMD shall have an entirely non-ferrous wheel or impeller and non-ferrous ring about the opening through which the shaft passes. The AMD shall be so constructed that a shift of the wheel or impeller or shaft will not permit two ferrous parts of the AMD to rub or strike. Spark-Resistant Package Notes: Bearings shall not be placed in the air or gas stream All aluminum construction Stainless steel shaft and hardware Shaft seal Enclosed belt tunnel Aluminum wheel Rub ring and shaft seal Enclosed belt tunnel Rub ring and shaft seal Enclosed belt tunnel The user shall electrically ground all AMD parts Aluminum Dampers: QMXU Arr. 9 only Arr. 9 only Arr. 9 only 16 Temperature Range ( F) Construction Requirements -20-180 `Standard ` Construction 180-230 231-300 (Arrangement 9 only) 301-500 (Arrangement 9 only) * Only required when above 1/2" w.g. `Enclosed ` Belt Tunnel `Standard ` Bearings (Arr. 9) `High ` Temperature Bearings (Arr. 3) `Metal ` Lube Lines `Enclosed ` Belt Tunnel `High ` Temperature Paint `Motor ` Heat Shield `RPM ` Limited to 96% of Max at 300 F `Shaft ` Seal* `High ` Temperature Bearings* `Metal ` Lube Lines `Enclosed ` Belt Tunnel `High ` Temperature Paint `High ` Temperature Bearings `Motor ` Heat Shield `RPM ` Limited to 91% of Max at 500 F `Steel ` Wheel Construction `Shaft ` Seal* `Shaft ` Cooler* `Ventilation ` Tube* `Metal ` Lube Lines

INSTALLATION & MOUNTING Recommended horizontal installation and mounting are shown here for various motor positions. Additional detail can be found in the QMX Installation, Operation and Maintenance Manual. Recommended Mounting Rails A Recommended Mounting Rails DESIGN BENEFITS CEILING G C Horizontal mounting configurations are provided with a standard support for both ceiling and floor applications. F D The mounting configurations and the motor position can be changed in the field. E A Lifting lugs are provided to assist in product installation. H B G FLOOR Recommended Mounting Rails Recommended Mounting Rails C Mounting rails are recommended for horizontal configurations with motor positions B, C, D, F, G and H with vibration isolation. Motor position is determined by viewing fan outlet. 17

INSTALLATION & MOUNTING Recommended vertical installation and mounting. Additional detail can be found in the QMX Installation, Operation and Maintenance Manual. CEILING FLOOR Recommended Mounting Base Recommended Mounting Base Vertical mounting configurations are provided with four heavy duty mounting brackets welded to each end. DESIGN BENEFITS The brackets allow a unit to be installed in either ceiling or floor configuration in both upblast and downblast applications. 18 ` ` Vertical mounting base are suggested for any vertical installation with vibration isolation.

STANDARD COATING The QMX is available with six coatings. The Lorenized TM coating in gray is standard. Lorenized TM is also available in 12 other colors shown. LORENIZED TM COATING Electrostatically applied, baked polyester powder coating Undergoes a five-stage environmentally friendly pretreatment/wash process before coating Baked and cured at 400 F; final coating thickness of 2.5 3.5 mil Coating is required to exceed 1,000 hour salt spray under ASTM B117 test method Offers strong chemical resistance, efficient mechanical performance and tough protection from outdoor elements Lorenized TM standard coating on QMX all 13 available Lorenized TM colors 19

OPTIONAL COATINGS Each type of coating offers unique qualities, benefits and color availability. COOK HIGH TEMP COATING Solvent based, heat resistant liquid coating which exhibits good corrosion resistance and color stability Final coating thickness is 0.8 1.5 mil Withstands service temperatures up to 1,000 F Available in BLACK. COOK EPOXY POWDER Electrostatically applied, baked epoxy powder coating Final coating thickness is 2.5 3.5 mil For outdoor applications, an optional UV resistant topcoat is available to prevent coating deterioration Available in DARK GRAY. AIR DRY PHENOLIC HERESITE VR-514 Conventional spray applied phenolic resin coating Final coating thickness is 2.0 4.0 mil For outdoor applications, an optional UV resistant topcoat (Heresite UC-5500) is required to prevent deterioration of the coating Available in BROWN. COOK EASY-CLEAN POWDER Electrostatically applied, baked modified epoxy silicone powder coating High temperature "non-stick" coating Final coating thickness is 1.0 2.0 mil Available in BLACK. COOK PHENOLIC EPOXY POWDER Electrostatically applied, baked phenolic epoxy powder coating Final coating thickness is 1.5 4.0 mil For outdoor applications, an optional UV resistant topcoat is required to prevent coating deterioration Available in LIGHT GRAY and BROWN. See our Coatings Brochure for more information. 20

QMX CERTIFICATIONS Through professional third party companies, the following information explains which products have obtained and maintained the title of "certified" here at Loren Cook Company. AMCA SOUND AND AIR AMCA Certified Ratings Seal Loren Cook products that bear the AMCA Certified Ratings Seal are licensed by AMCA International. These products meet the AMCA Standard and are within the product scope of AMCA International. SEISMIC Seismically Qualified The below QMX models have been shake table tested to exceed spectral response accelerations covering the most severe seismic conditions found within the United States. UL 705 LISTED Power Ventilator The UL 705 Listing is the standard for electrical safety for permanently connected power ventilators. All QMX models are constructed in accordance with UL 705, only when with motors. QMX QMXD QMXHP QMXHPD Level 2 Only QMX QMXHP QMXXP All Models SEISMICALLY QUALIFIED For more information, see Seismic Certification Flyer. Listed 21

CERTIFICATIONS CONTINUED The Cook products shown below are either UL Listed for Power Ventilator for Smoke Control Systems or UL 762 Listed for Restaurant Exhaust Appliances. SMOKE CONTROL Power Ventilator for Smoke Control Systems The UL Listing Power Ventilator for Smoke Control Systems is a test procedure and category initiated by Loren Cook Company and developed in a joint effort with UL in 1990. The products below are UL Smoke Control Listed. UL 762 LISTED Power Ventilator Restaurant Exhaust Appliances Loren Cook Company products that bear the UL 762 Listing are designed to exhaust contaminated or grease-laden air. The products shown below are UL Listed to operate continuously at the shown elevated temperatures. Sizes 90 600 QMX QMXHP QMXU QMXHPU Max. Temp. 300 F QMX QMXHP QMXU QMXHPU Sizes 150 600 QMXD QMXHPD QMXDU QMXHPDU QMXXP QMXXPU QMXXP QMXXPU Max. Temp. 500 F QMX QMXHP QMXXP QMXXPU Listed UL Requirements Unit must be listed under UL 705 Unit must be supplied with belt tunnel, motor heat shield, steel wheel construction Unit must withstand specified elevated air stream temperature for specified duration Listed UL Requirements Unit must be supplied with drain, access door, flanged inlet and outlet, belt tunnel and motor heat shield Outdoor applications must be supplied with a weather cover For more information, see UL Smoke Control Flyer. 22 For more information, see UL 762 Restaurant Flyer.

OVERALL DIMENSIONS The following overall dimensions are in inches. For more detailed dimensions, see the product submittal. ARRANGEMENT 9 LEVEL 1 Height Length Width Unit Size 165 180 202 225 245 270 300 330 365 402 445 490 540 600 Height 39 15/16 43 7/16 47 1/8 50 1/4 55 3/8 61 3/8 66 1/2 70 1/2 76 11/16 84 11/16 92 15/16 99 9/16 109 1/8 120 1/4 Length 33 35 37 1/2 41 44 1/2 47 54 58 1/2 64 68 1/2 74 80 1/2 87 95 1/2 Width 26 1/2 28 5/8 31 3/4 34 15/16 37 3/4 41 5/16 45 1/2 49 3/4 54 3/4 59 15/16 66 1/16 72 3/8 79 7/16 88 23

OVERALL DIMENSIONS The following overall dimensions are in inches. For more detailed dimensions, see the product submittal. ARRANGEMENT 9 LEVEL 2 Height Length Width Unit Size 90 120 135 150 165 180 202 225 245 270 300 330 365 402 445 490 540 600 Height 28 1/8 34 5/8 36 7/8 39 1/2 43 7/16 45 7/16 49 1/8 53 3/4 56 7/8 61 3/8 68 1/2 72 1/2 80 11/16 88 11/16 94 15/16 103 9/16 111 1/8 122 1/4 Length 19 7/8 24 27 30 33 35 37 1/2 41 44 1/2 47 54 58 1/2 64 68 1/2 74 80 1/2 87 95 1/2 Width 15 7/8 20 1/16 22 1/4 24 3/8 26 1/2 28 5/8 31 3/4 34 15/16 37 3/4 41 5/16 45 1/2 49 3/4 54 3/4 59 15/16 66 1/16 72 1/2 79 9/16 88 3/8 24

OVERALL DIMENSIONS The following overall dimensions are in inches. For more detailed dimensions, see the product submittal. ARRANGEMENT 9 LEVEL 3 Height Length Width Unit Size 150 165 180 202 225 245 270 300 330 365 402 445 490 540 600 Height 43 44 15/16 48 15/16 52 5/8 57 3/4 60 7/8 65 3/8 74 1/2 78 1/2 84 11/16 90 11/16 96 15/16 103 9/16 111 1/8 129 1/4 Length 30 33 35 37 1/2 41 44 1/2 47 54 58 1/2 64 68 1/2 74 80 1/2 87 95 1/2 Width 25 1/4 27 3/8 28 1/2 32 5/8 35 13/16 38 5/8 42 3/16 46 3/4 51 56 3/4 61 15/16 68 13/16 75 7/8 85 15/16 92 7/8 25

OVERALL DIMENSIONS The following overall dimensions are in inches. For more detailed dimensions, see the product submittal. ARRANGEMENT 3 Height Length Width Unit Size 180 202 225 245 270 300 330 365 402 445 490 540 600 Height 45 7/16 49 1/8 53 3/4 56 7/8 61 3/8 68 1/2 72 1/2 80 11/16 88 11/16 94 15/16 103 9/16 111 1/8 122 1/4 Length 29 1/4 31 13/16 33 13/16 35 13/16 38 37 13/16 40 1/8 44 47 15/16 52 9/16 57 15/16 64 3/8 70 15/16 Width 28 5/8 31 3/4 34 15/16 37 3/4 41 5/16 45 1/2 49 3/4 54 3/4 59 15/16 66 1/16 72 1/2 79 9/16 88 3/8 26

OVERALL DIMENSIONS The following overall dimensions are in inches. For more detailed dimensions, see the product submittal. ARRANGEMENT 4 Height Length Width Unit Size 150 165 180 202 225 245 270 300 330 365 402 445 490 540 600 Height 25 3/8 27 9/16 29 13/16 33 1/8 36 1/2 39 3/8 43 1/8 47 1/2 51 7/8 57 3/16 62 11/16 69 1/16 75 5/8 83 1/16 93 15/16 Length 30 1/4 33 1/4 35 1/8 37 3/4 41 1/4 44 3/4 47 1/4 54 1/4 58 3/4 65 1/4 69 3/4 75 1/4 81 3/4 88 1/4 96 3/4 Width 24 3/8 26 1/2 28 5/8 31 3/4 34 15/16 37 3/4 41 5/16 45 1/2 49 3/4 54 3/4 59 15/16 66 1/16 72 1/2 79 9/16 88 3/8 27

OVERALL DIMENSIONS The following overall dimensions are in inches. For more detailed dimensions, see the product submittal. ARRANGEMENT 9 QMXE/QMXS EXHAUST/SUPPLY QMXS Height Diameter QMXE Height Width Unit Size 90 120 135 150 165 180 202 225 245 270 300 QMXE Height 39 3/16 39 5/8 43 15/16 46 15/16 51 1/8 57 3/4 60 1/2 64 64 7/16 67 3/16 74 QMXS Height 45 3/4 46 11/16 53 3/4 56 3/4 62 1/2 71 13/16 76 1/16 79 9/16 75 7/16 78 3/16 85 9/16 Diameter 28 9/16 32 13/16 43 9/16 43 9/16 47 5/8 52 5/8 62 5/8 62 5/8 73 5/8 73 5/8 73 5/8 Width 37 3/8 43 5/8 46 1/2 51 55 57 3/4 61 13/16 68 1/8 71 13/16 76 5/16 85 28

OVERALL DIMENSIONS The following overall dimensions are in inches. For more detailed dimensions, see the product submittal. ARRANGEMENT 9 QMXU Height Length, Sqr. Width Unit Size 90 120 135 150 165 180 202 225 245 270 300 330 365 402 445 490 540 600 Height 40 9/16 45 11/16 49 11/16 54 11/16 58 11/16 61 11/16 65 11/16 70 11/16 76 5/8 80 7/8 90 1/4 96 3/4 104 7/8 112 3/8 120 7/8 131 3/8 141 7/8 154 3/8 Length 20 1/4 24 1/4 26 1/4 30 1/4 35 1/4 37 1/4 40 1/4 43 1/4 46 1/4 50 1/4 54 1/4 58 1/4 64 1/4 69 1/4 75 1/4 82 3/8 90 3/8 98 3/8 Width 37 3/8 43 5/8 46 1/2 51 55 57 3/4 61 13/16 68 1/8 71 13/16 76 5/16 82 89 1/4 96 1/4 105 112 7/16 122 1/2 131 7/8 142 29

2015 E. Dale St. Springfield, MO 65803 417-869-6474 Fax: 417-862-3820 lorencook.com