INSTALLATION INSTRUCTIONS

Similar documents
Factory Option Codes L M E S P R D V F F H E

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

ENERGY RECOVERY SYSTEM 60 HZ

A. NU2035 HRV Specifications NU2035

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

The newest addition to RenewAire s broad line of Energy Recovery Ventilators.

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

ERU ENERGY RECOVERY UNIT

ECONOMIZERS. 5/2012 Supersedes

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

Model 8144NC Fresh Air Ventilator

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

INSTALLATION INSTRUCTIONS FOR ENERGY RECOVERY VENTILATOR (FIXED) USED WITH GOODMAN ROOFTOP UNIT MODELS 7 ½ TO 12 ½ TON UNITS

Safety & Installation Instructions

Installation Instructions

ENERGY RECOVERY WHEEL

INSTALLATION INSTRUCTIONS

ZHA/ZHB SERIES WARNING

Installation Instructions

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

LXIPEB33 505,038M MARCH 14, 2012 SUPERCEDES

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

Products for Indoor Air Quality and Control

ECONOMIZERS. 1/2012 Supersedes

FAN POWERED TERMINAL UNITS

Cooling Capacity CFM in. w.c. (125 Pa)

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

Package Unit Modulating Economizer Installation Instructions

STAND ALONE ERV D-SERIES

Cooling Capacity CFM in. w.c. (125 Pa)

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

Electronically Commutated Motor Wiring Manual

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

STAND ALONE ERV S-SERIES

STAND ALONE ERV M-SERIES

STAND ALONE ERV O-SERIES

INSTALLATION INSTRUCTIONS FOR ROOFTOP STAND ALONE ENERGY RECOVERY UNIT IN SIDE BY SIDE DESIGN

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

INSTALLATION INSTRUCTIONS FOR ENERGY RECOVERY VENTILATOR (FIXED) USED WITH TRANE ROOFTOP UNIT MODELS YCD/TCD 15 TO 20 TON UNITS

CH5000 Heat Recovery Ventilator

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature

ENERGY RECOVERY WHEEL

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

Engineering Data Book

Cooling Capacity CFM in. w.c. (125 Pa)

INSTALLATION INSTRUCTIONS FOR ROOFTOP STAND ALONE ENERGY RECOVERY UNIT IN VERTICAL (UP/DOWN) AIRFLOW DESIGN

Cooling Capacity CFM in. w.c. (125 Pa)

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

FAN POWERED TERMINAL UNITS

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Installation Instructions

CHP

Fan Coil Unit (FCU) Fan Motor Control

SUNLINE 2000 (WORLD 50 HZ)

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

INSTALLATION INSTRUCTIONS FOR ENERGY RECOVERY VENTILATOR (PIVOTING) USED WITH GOODMAN ROOFTOP UNIT MODELS 2 TO 5 TON UNITS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

Direct Gas-Fired Heating

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FN Fan-Coil Units High-Performance, Horizontal

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

UPFLOW/ HORIZONTAL GAS FURNACE

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

ENERGY RECOVERY WHEEL

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Installation, Operation and Maintenance Manual

Package Air Conditioners

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

Installation, Operation and Maintenance Manual

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

Fan Powered Low Profile Variable Volume Terminal Units

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

Transcription:

MiniCOREVentilator ENERGY RECOVERY CORE INSTALLATION INSTRUCTIONS MC500-1ERV JANUARY 10, 2018 SUPERSEDES: NONE INSTALLATION INSTRUCTIONS FOR MINICORE VENTILATOR (MCV) WITH FACTORY INSTALLED OPTIONS USED AS A STAND ALONE OR WITH SPLIT SYSTEMS UNITS Energy recovery COMPONENT certified to the AHRI Air-to-Air Energy Recovery Ventilation Equipment Certification Program in accordance with AHRI Standard 1060-2000. Actual performance in packaged equipment may vary. ETL Certified per UL 1995 and CSA 22.2 I - Shipping And Packing List Package 1 of 1 contains: 1 - MiniCore Ventilator Assembly II - Shipping Damage Check unit for shipping damage. Receiving party should contact last carrier immediately if shipping damage is found. III - General These instructions are intended as a general guide and do not supersede local codes in any way. Authorities having jurisdiction should be consulted before installation. IV - Requirements When installed, the unit must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with the current National Electric Code, ANSI/NFPA No. 70. V - Application MiniCore ventilators are used as a stand alone indoor option for heat recovery ventilators used in light commercial applications. These ventilators conserve energy by transferring heat energy across two opposing air streams using a polymer core heat exchanger. This process works in the summer by rejecting the heat energy from incoming intake air and in the winter by conserving the heat energy from the exhaust air, allowing outdoor ventilation rates to be increased by factors of three or more without additional energy penalty or increase in size of the heating or air conditioning systems. VI - Rigging Unit For Lifting CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. WARNING Electric shock hazard. Can cause injury or death. Before attempting to perform any service or maintenance, turn the electrical power to unit OFF at disconnect switch(es). Unit may have multiple power supplies. VII - Installation When choosing a location to mount the MiniCore Ventilator take into consideration ductwork layout as well as access for future filter changes and Core cleaning. See maintenance section on Page 4 for dimensions. 1. Maximum weight of unit is: Model# MCV-500 MCV-1000 Net Weight 182 222 Ship Weight 230 270 2. Remove carton. 3. All panels must be in place for rigging. 4. Lift unit into place with a winch or jack. Figure 1 Normal installation of the MiniCore Ventilator unit is hanging from the 4 corners using the included hanging kit though the units can be mounted on a shelf or on the floor of a mechanical room using optional floor vibration isolators. 1

The maximum weight of a MiniCore Ventilator is less than 225 lbs, Using 3/8" all-thread and the included hanging brackets is the preferable method of supporting the unit though the use of metal strap to hang the unit is also acceptable. When hanging the unit be sure to take into account the need to provide access for filter replacement and Core removal as well as blower balancing or removal through the bottom access panels. While orientation of the heat exchanging core inside of the MiniCore Ventilator is important for maximizing airflow orientation of the Ventilator itself is not, the MiniCore can be mounted in a vertical or horizontal fashion. Additionally the Fresh Air intake and Return intake can either be mounted on the side of the MiniCore or on the end by switching the duct collar and cover panel attached using 5/16" screws. See Figure 2. Duct Option 1 High voltage: 115V: Connect the high voltage wires to L1 (Hot) & L2 (Common), hook the ground wire to the provided grounding nut. See Wiring Diagrams on Pages 6-7. 208/230V: Single phase: Connect the high voltage wires to L1 (Hot) & L2 (Common) connect the ground wire to the provided ground nut. Check Voltage into the unit and adjust the voltage input to the transformer from 230V to 208V if necessary by switching wires at transformer. See Wiring Diagrams on Pages 6-7. Low voltage: Standard units: Pass low voltage wire through the provided knockout on the 2 gang terminal strip access box next to the power disconnect, and connect R to terminal #1 of terminal block TB38 and G to terminal #3. See Wiring Diagrams on Pages 6-7 and Figure 3 The MiniCore Ventilator can be controlled by any dry contact closure like those in a CO 2 sensor with relay, switch or timer. Duct Option 2 Figure 3 Figure 2 Once the MiniCore Ventilator is hung connect ductwork to proper sectors of the unit with ¼" screws, use tape to seal seams. Supply and Exhaust are labeled on the outside of the cabinet and are determined by the orientation of the Core inside of the MiniCore Ventilator, a sticker on the Core will indicate the supply (outdoor air) vector. The Outside Air and Return connections will always be on the opposite side of the MiniCore Ventilator from their respective Supply and Exhaust blowers. See Figure 2. Wiring A ¾" knock out is provided for high voltage on the top and bottom of the high voltage disconnect switch mounted on the side of the unit. ECM units: Pass the low voltage wiring through the provide knockout on the terminal access box and connect R to terminal #1 on 7 pin terminal box TB38 and G to #3. The default wiring for the MiniCore Ventilator with ECMs is to operate in the modulating speed mode terminals #4-7 are for speed control. To control both blowers in unison wire the 0-10vdc control signal to terminals 4 (10vdc+) and 5 (10vdc com) and add a jumper between terminals 4 and 6. If the Blowers are controlled independently then wire the exhaust blower signal to terminals 4 &5 and the supply signal to terminals 6 & 7, See Adjusting Blower Speed in Section IX - System Check for balancing information. To use the motor in 2 speed operation attach the blue wires from TB39 and TB40 to relays K163 & K164 at pin #4. With the blue BL-25 and BL-30 wires in place the ECM with default to 2 speed operation. See Wiring Diagram on page 7 and Figure 4. 2 MC500-1ERV

Figure 4 VIII - Operation How It Works The unit uses a dpoint polymer based ERV core which offers latent and sensible energy recovery with no cross contamination and no moving parts. In the summer outside heat and humidity is rejected from the incoming outside airstream and exhausted out the building, while in the winter the same process works to conserve wasted heat and humidity making the building more efficient, healthier and more comfortable. The dense polymer membrane uses selective transfer technology to allow heat and water vapor to permeate through, while blocking contaminant compounds. The transfer is driven by temperature and humidity differentials between the airstreams. This allows you to reduce the size of the cooling system by 30% while still meeting outside air requirements. The Cores material is designed to prevent mold and bacteria growth the material was ISO 846 tested with a rating of 0, is designed to avoid virus transfer ASTM Method F-1671 tested with 0 penetration, and eliminate cross contamination from exhaust air 0% EATR certified to AHRI 1060. It s polymer construction also means that it is washable with water for easy cleaning. IX - System Check 1. Turn off power to the unit 2. Remove access cover for the terminal strip access box and add a jumper to terminals 1 & 3. 3. Restore power to the unit. Observe that both blower motors are running. 4. Adjustments to the speed of the motors can be made by changing the input on the multi tap blower motors, the speed control on EC Motors or by adjusting the optional speed control. A - Blower Speed Adjustment MCV500/1000 - Both fresh air and exhaust air blowers are direct drive multi-tap motors. Both blowers are factory set at "high" speed for maximum airflow. To determine air flow setting, external static pressure readings will need to be read across the MiniCore. B - Air Balancing Adjustment 1. Remove plastic plugs in access panels (4 total). 2. With a manometer measure pressure drop [inches of water column] diagonally across the MiniCore. Unit CFM for 3 speed PMC motors is determined then by referring to Table #1 on Page 5. 3. Repeat the same process for the other airflow vector of MiniCore. 4. System can be balanced by adding dampers to ductwork or by adjusting blower speed. C - Adjusting Blower Speed 3 speed PCM motors: Standard units have 2 terminal blocks available (TB39 for exhaust and TB40 for supply) where the speed taps on the 3 speed motors can be changed. Move the Black wire from terminal #1 to terminal #2 (med) or #3 (low) to lower blower speeds. An additional 115 or 230 volt speed control is available (part #s?) to balance each blower with in these ranges. The speed control is wired in line on the Black BK-102 or BK-101 wires before the terminal block, and is mounted externally in a 2 gang work box on or near the MiniCore. Speed is reduced by turning the knob counter clockwise until cfm is met. See Table #1 on Page 5 for balancing data.. Variable speed ECM units: MiniCore Ventilators with electronically commutated motors are shipped with blue (BL-25 and BL-30) wires attached to terminal #1 of TB39 and TB40 in the blower compartment (See Figure?) locking the ECM in low speed mode, to switch to high speed move the Blue wires to terminal #2. To use the Variable speed option these blue wires need to be disconnected from the relays (K163 & K164?) they are attached to and 0-10 VDC control wiring should be connected to terminals 4 through 7 detailed in the Low Voltage connections on Page 2. See Wiring Diagram on Pages 7. X - Maintenance 1. All motors use prelubricated sealed bearings; no further lubrication is necessary. 2. Make visual inspection of filters, motor assemblies and MiniCore Ventilator s Heat exchange core during routine maintenance. 3. Filters should be checked periodically and replaced when necessary. Filters are located in front of Core in the unit. MC500-1ERV 3

A - Core Removal (See Figure 5) B - Filter Removal (See Figure 6) 1. Remove Access panels by opening each panel and then releasing the spring loaded pins in the hinges by pinching the tabs together. 1. Open the Filter Access panel by opening the two spring loaded latches to expose filters. 2. Remove the center divider panel by removing the two 5/16" screws at with end of the panel on the side of the MiniCore. 2. Slide filters outwards. 3. Carefully slide the core outwards. Figure 6 B C A Unit MCV500 MCV1000 A B C 42 1/4 51 15 1/2 20 3/4 Figure 5 4 MC500-1ERV

Blower Data for PSC Motors MCV 500 Cabinet External Static Pressure 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Low 649 634 586 510 402 313 233 129 NA NA NA CFM Medium 786 768 709 618 487 379 282 157 NA NA NA High 957 935 927 929 900 853 800 738 688 632 535 MCV1000 Cabinet External Static Pressure 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Low 1146 1124 1079 1042 1006 969 895 918 892 853 826 CFM Medium 1388 1361 1307 1262 1218 1174 1084 1112 1080 1033 1001 High 1618 1586 1524 1471 1420 1368 1264 1296 1259 1204 1166 Table #1 Performance Test for MCV500 with ECM Motor Supply External Static Pressure (in wc) Input Voltage (v) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2 259 253 158 3 345 337 254 112 4 431 421 350 232 83 CFM 5 516 504 447 353 228 132 49 6 602 588 543 473 373 290 216 120 7 688 672 639 593 518 448 383 301 273 216 159 8 773 755 736 714 663 607 551 481 472 430 389 9 859 839 832 834 808 765 718 662 618 568 481 10 860 840 833 835 809 766 719 663 618 568 481 Exhaust External Static Pressure (in wc) Input Voltage (v) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2 38 3 138 80 15 4 238 182 121 52 CFM 5 339 284 226 164 101 50 6 439 386 332 275 216 164 7 539 488 438 386 331 278 227 175 123 71 19 8 640 590 543 498 446 393 347 298 249 200 151 9 740 692 649 609 561 507 467 421 375 330 284 10 741 693 650 610 562 508 456 410 373 326 291 Performance Test for MCV1000 with ECM Motor Supply External Static Pressure (in wc) Input Voltage (v) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2 3 4 642 561 472 325 CFM 5 795 734 664 575 459 301 123 6 986 953 879 815 734 643 534 396 166 7 1237 1178 1129 1050 995 935 854 795 700 604 467 8 1377 1358 1347 1290 1214 1179 1114 1066 994 914 845 9 1408 1388 1392 1366 1339 1334 1300 1284 1263 1240 1186 10 1409 1394 1370 1349 1339 1317 1310 1290 1280 1255 1239 Exhaust External Static Pressure (in wc) Input Voltage (v) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2 3 4 393 333 232 122 CFM 5 582 508 420 346 208 137 36 6 775 721 651 567 506 431 266 196 120 7 974 915 860 796 735 671 588 522 414 284 208 8 1168 1119 1084 1028 987 938 881 837 757 694 612 9 1304 1270 1225 1187 1137 1094 1052 1004 945 888 801 10 1375 1352 1328 1308 1285 1232 1192 1159 1111 1071 1024 MC500-1ERV 5

Notes: 1. Selective voltage terminal for proper unit voltage. MCV500 / MCV1000 UNIT WIRING DIAGRAM Mini Ventilator W/ Factory Installed Options 115V / 230V (1 PH) Unit#: 01-C45/C75/C150-02xH-01 / -21 6 MC500-1ERV

MCV500E / MCV1000E UNIT WIRING DIAGRAM Notes: 1 Selective voltage terminal for proper unit voltage. 2 Omit BL-25, BL-30 for 0-10V Signal Control, Wire BL-25 to TB39-1 and BL-30 to TB40-1; for low speed, Wire BL- 25 to TB39-2, BL-30 to TB40-2; for high speed. Mini Ventilator W/ Factory Installed Options 115V / 230V (1 PH) Unit#: 01-C45/C75/C150-02xE-01 / -21 MC500-1ERV 7

Incoming Voltage L1-L2 Running Voltage L1-L2 Secondary Voltage START UP INFORMATION SHEET VOLTAGE - MCV UNIT AMPERAGE - MCV MOTORS Intake Motor: Nominal HP Rated Amps Running Amps Exhaust Motor: Nominal HP Rated Amps Running Amps Wheel Motor: Nominal HP Rated Amps Running Amps AIRFLOW Intake Design CFM Pressure Drop Calculated CFM Exhaust Design CFM Pressure Drop Calculated CFM Amb. db Temp Return Air db Temp* Tempered Air db Temp* Amb. wb Temp Return Air wb Temp* Tempered Air wbtemp* * Measure after 15 minutes of run time INSTALLATION CHECK LIST MiniCore Model # Serial # Owner Owner Phone # Owner Address Installing Contractor Start Up Mechanic Inspect the unit for transit damage and report any damage on the carrier's freight bill. Check model number to insure it matches the job requirements. Install field accessories and unit adapter panels as required. Follow accessory and unit installation manuals. Verify field wiring, including the wiring to any accessories. Check all multi-tap transformers, to insure they are set to the proper incoming voltage. Verify blower wheels are centered. Realign if needed. Prior to energizing the unit, inspect all the electrical connections. Power the unit. Bump the motor relay to check rotation. If blower motor fans are running backwards, deenergize power to the unit, then swap reversing plug on motors to change direction. Re-check. Perform all start up procedures outlined in the installation manual shipped with the unit. Fill in the Start Up Information as outlined on the opposite side of this sheet. Provide owner with information packet. Explain the thermostat and unit operation. 8 MC500-1ERV