Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Similar documents
Burst-Firing 74B5 LISTED INDUSTRIAL CONTROL EQUIPMENT. User Manual

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

Thyristor power units TC3000. Three-phase load control. User Manual

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

TC abc. Three phase thyristor for resistive, inductive and temperature dependent (complex) loads CONTROLS DATA MANAGEMENT PROCESS AUTOMATION

INDUSTRIAL POWER SUPPLIES SFL-SERIES

CD3000S-1PH Thyristor Unit Heater Break version

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Switching DC Power Supply

The High Power Stack Horizon

CD3000S-1PH Thyristor Unit Analog Input version

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

SOLSTART Instruction Manual

Solid State Relays contactor with Integrated Fuse Type RGC1F

GTS 15/25/40/50/60/75/90/120A

GTS-L4 5 / 10 / 15 TECHNICAL DATA

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

Rental Industry Safety Tester Safe Check 5s

J TS 7090 Thyristor power switch

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Model Number Structure

RVS-AX Instruction Manual

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Technical Documentation

HIB Enclosed Inverter User Guide

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Appendix: Safety and application notes for... 15

REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Compact System NRGS 11-2 NRGS Original Installation Instructions English

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

GTZ 25 / 40 / 55. TECHNICAL DATA General features. Category of use: AC51, AC53a

Appendix: Safety and application notes for 19

Electromotoric Actuators

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Power Switching Principles

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

SMT-BM 20 A BMM 05 F BMM 05 AF

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Solid State Relays, 3-phase

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

ABB component drives ACS150, 0.5 to 5 Hp

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Electromotoric Actuators

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

SIRIUS 3RU2 Thermal Overload Relays

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

DC/DC converters - MINI-PS DC/ 5-15DC/

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

DX³ RCCBs - ID 4P up to 100 A

GQ 15 / 25 / 50 / 90 A SINGLE PHASE SOLID STATE RELAYS

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

GTZ 25 / 40 / 55. THREE-PHASE SOLID STATE RELAYS WITH LOGIC CONTROL Vdc / Vac PROFILE. TECHNICAL DATA General features

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Technical Data Sheets

1329I Integrated Drive/Motor CE Filter Option Kit

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

MINI MCR-SL-UI-UI(-SP)(-NC)

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

DC POWER SUPPLY ALIMENTATION C.C.

Modular contactors and relays

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

Differential pressure sensor

This manual is to be given to the end user. Optional RFI filter. Drive. Stop. Thermal protection device. Start / Reset +DC.

QF(19) - Series Miniature Circuit Breakers

Industrial Power Supplies

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Open Chassis Star-Delta Starter User Guide

MINI MCR-SL-UI-UI(-SP)

Dimensions WxHxD [mm] Weight [kg]

Declaration of Conformity

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

COUNTIS E22 Three-phase energy meter Direct - 80 A

Industrial Chargers and

G3PE-Single-phase. Solid State Relays for Heaters

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

Electronic overload relay EF65, EF96 and EF146

Emotron FDU and VFX 2.0

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Power consumption In operation At rest For wire sizing

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

QF(13) - Series Miniature Circuit Breakers

Transcription:

Thyristor power controller TE10A Burst-firing Single-cycle Advanced Single-cycle Control of short-wave infrared elements and loads of constant resistance up to 20kW User Manual Copyright Eurotherm Automation 1996 All rights reserved. All reproduction or transmission in any form or using any procedure, without written authorisation from EUROTHERM AUTOMATION, is strictly prohibited. User manual TE10A HA175247ENG Issue 2 1

TE10A Industrial thyristor power controller Burst-firing, Single-cycle or advanced Single-cycle CONTENTS SAFETY DURING INSTALLATION AND USE......... 3 EUROPEAN DIRECTIVES.......................... 4 TECHNICAL SPECIFICATION...................... 6 PRODUCT CODE.................................. 8 FUSES........................................... 8 CURRENT DERATING (as a function of ambient temperature)....................................... 8 INSTALLATION AND DIMENSIONAL DETAILS....... 9 FRONT FACIA................................... 10 TERMINALS AND CONNECTORS.................. 11 WIRING........................................ 12 Control of TE10A by temperature controller............ 12 Local control by potentiometer....................... 13 Local control by contacts............................ 13 Auxiliary power supply (option)...................... 14 INPUT SIGNAL.................................. 15 FIRING MODES.................................. 16 Burst firing....................................... 16 Single-cycle...................................... 17 Advanced Single-cycle............................. 18 CONFIGURATION OF FIRING MODE............... 19 Burst firing and standard Single-cycle (codes FC and FC1). 19 Advanced Single-cycle (code SCA)................... 20 For any further information, or if in doubt, please contact Eurotherm Controls wh e re qualified staff are ava i l able to advise or assist you with the commissioning of your installation. 2 User manual TE10A

SAFETY DURING INSTALLATION AND USE This symbol means that failure to take note of the information given in this manual may have serious consequences for the safety of personnel and may even result in electrocution. DANGER! Units must be installed in fan-cooled electrical cabinets to ensure that condensation and pollution are excluded. The cabinet must be closed and bonded to the safety earth in accordance with Standards NFC15-100, IEC 364 or current national Standards. It is the responsibility of the user to install and wire the installation in accordance with current professional practice. Before any connection or disconnection, make sure that power and control cables and leads are isolated from voltage sources. The safety earth must be connected before any other connection is made during wiring and should be the last cable to be disconnected. Thyristors are not isolating devices. The high-speed fuse recommended is used only to protect the thyristors: under no circumstances can it be used to protect the installation. For this reason it is very important to fit a suitable device guaranteeing protection for, and electrical isolation of, the installation in compliance with current practice. Access to the internal components of the product is prohibited to users Disconnect the TE10A completely before dismantling. The temperature of the heatsink fins may exceed 100 C. Avoid all contact, even occasional, with the heatsink while the TE10A is operational. The heatsink remains hot for approximately 15mins after the TE10A has been switched off. User manual TE10A 3

EUROPEAN DIRECTIVES CE MARKING TE10A products carry the CE mark in compliance with the essential requirements of the Low Voltage Directive 73/23EC of 19/2/73 (amended by the Directive 93/68/EC of 22/7/93). For safety reasons, TE10A products installed and used in compliance with this user manual meet the essential requirements of the European Directives mentioned above. CE DECLARATION OF CONFORMITY A CE Declaration of conformity is available on request. ELECTROMAGNETIC COMPATIBILITY (EMC) (For an industrial environment only, must not be used in domestic environments) Eurotherm certifies that TE10A Burst firing and Single Cycle fired products, installed and used in compliance with their manual, meet the following EMC standards and enable the system which incorporates them to comply with the EMC Directive as far as those TE10A products are concerned. EMC STANDARDS Immunity Generic standard: EN 50082-2 Test standards : EN 61000-4-2, EN 61000-4-4,EN 61000-4-5 ENV 50140, ENV 50141, ENV 50204 Emission Generic standard : EN 50081-2 Test standard : EN 55011 Product standard : IEC 1800-3 4 User manual TE10A

INTERNAL EMC FILTER An EMC filter is incorporated into the Burst firing and Single Cycle firing TE10A to reduce conducted emission in accordance with the EMC Directive. VALIDATION BY INDEPENDENT BODY Eurotherm has validated the compliance of these TE10A controllers with the Low Voltage Directive mentioned above and with EMC standards through product design and laboratory testing. The controls carried out on TE10A products are listed in a Technical Construction File validated by the LCIE (Central Laboratory for the Electrical Industries), a Recognised Competent Body. PRECAUTIONS Before installation, please read this manual thoroughly. Eurotherm cannot be held responsible for any damage to persons or property, or for any financial loss or costs arising from incorrect use of the product or failure to observe the instructions given in this manual. PERSONNEL The installation, configuration, commissioning and maintenance of the power unit should only be carried out by personnel qualified and trained to work with low voltage electrical equipment in an industrial environment. INDEPENDENT SAFETY DEVICE Given the value of the equipment controlled by TE10A, it is the responsibility of the user, and it is highly recommended, that an independent safety device (alarm) should be installed. This alarm must be tested regularly. Eurotherm can supply suitable equipment. 'ELECTROMAGNETIC COMPATIBILITY' INSTALLATION GUIDE In order to help you reduce the effects of electromagnetic interference depending on the product installation, Eurotherm can supply you with the 'Electromagnetic Compatibility' Installation Guide (ref. HA025464). User manual TE10A 5

TECHNICAL SPECIFICATION Power Nominal current at 45 C 16, 25 or 40A. Nominal voltage 100Vac to 500Vac +10%, -15% Supply frequency 50 or 60Hz (nominal) ±2Hz Current in off state Below 30mA typically Regulation Type of regulation The load power is proportional to the control input Linearity Stability Firing modes Firing indicator Control Inputs External signal type Input impedance Local control CE marking Electrical safety 6 Better than ±2% of the full range Automatic compensation for supply variations from ±10% of the nominal voltage. Stability better than ± 2% of the full range on constant resistance Thyristor firing at zero voltage Burst mode: firing and non-firing over a whole number of mains cycles Single-cycle: firing or non-firing for one mains cycle Advanced Single-cycle: firing over a whole number of mains cycles, non-firing over a whole number of half cycles Green LED on front facia Analogue, DC voltage or current: 0-5V, 0-10V or 4-20mA Voltage 100KΩ, current 250Ω External potentiometer 10k 'Dry' contact: logic operation - 'all or nothing' A '5V user' voltage is available The CE Mark in accordance with the Low Voltage Directive 73/23/EC amended by the Directive 93/68/EC of 22/7/93 User manual TE10A

EMC Environment Operating temperature Operating atmosphere These TE10A products comply with Electromagnetic Compatibility test standards (see page 4) 0 to 60 C, (see derating curves) at maximum altitude of 2000m Storage: -10 to +70 C Non-conductive, non-explosive and noncorrosive RH: 5 to 95%, non-condensing Humidity Pollution Pollution degree 2 permissible (IEC 664) Thyristor protection External fuse, internal MOV (varistor) and RC snubber Protection degree IP20 (in accordance with IEC 529; 11.4, table 5) Isolation distances according to IEC 664 Insulation (1 minute test) Cooling Mounting Option Auxiliary power supply Wiring Guarantee 2000Vac between power and earth 3600Vac between power and control inputs Natural convection Vertical on DIN rail 115Vac or 230Vac used in the case of nonstandard mains or if independent power supply required The separate auxiliary power supply must be in phase or anti-phase with the load supply Two years for parts and labour (return to factory) In order to maintain its leading edge Eurotherm may have to make changes to its specifications without advance notice. For any further information, or if in doubt, please contact Eurotherm Controls. User manual TE10A 7

PRODUCT CODE Model / Current / Voltage / Input / Firing /Option / 00 TE10A 16A 100V 415V 0V5 Separate 25A 115V 440V 0V10 Single-cycle: power 40A 200V 480V 4mA20 FC1 Supply 230V 500V Advanced 115V 240V Single-cycle: 230V 277V SCA* 380V Burst-firing: 400V FC * SCA mode uses different firing board THYRISTOR PROTECTION FUSES (Thyristor protection except for short-wave infrared application) Current Rating Code (Fuse & fuse-holder) Dimensions (mm) 16A 20A FU1038 / 16A / 00 81 x 17.5 x 68 25A 32A FU1038 / 25A / 00 81 x 17.5 x 68 40A 50A FU1451 / 40A / 00 95 x 26 x 86 CURRENT DERATING (as a function of ambient temperature) Dotted line ( ): limit of recommended fuse 50 40 30 20 10 I eff(a) IN = 25 A I N = 16 A I N : nominal current at 45 C IN = 40 A Ambient temperature ( C) 0 20 25 30 35 40 45 50 55 60 8 User manual TE10A

INSTALLATION AND DIMENSIONAL DETAILS Minimum spacing between 2 TE10A units: 10mm up to 45 C 17 5mm over 45 C Dimensions (in mm) DIN rail clip mounting (EN 50022-35 x 7 5 and 35 x 15) Ground continuity: For reasons of electromagnetic compatibility ensure that the metal DIN rail of the TE10A installation is electrically bonded to the reference ground (panel or bulkhead). User manual TE10A 9

FRONT FACIA 10 User manual TE10A

TERMINALS AND CONNECTORS Power terminal block: cage terminals for 1.5 to 16mm 2 cables, strip insulation by 16 mm, tightening torque 1.2 Nm. Safety earth wiring: same section as power conductor, tightening torque 2 Nm. Control connection to terminals 5 & 6, and separate auxiliary power supply connection (option) to terminals 8 & 10: use 0.5 to 1.5 mm 2 wire, strip insulation by 7 mm, tightening torque 0.4 Nm (0.25 Nm for terminals 8 & 10). View from below User manual TE10A 11

WIRING Control of TE10A by temperature controller L N Line protection circuit breaker (installed by user) 1A fuse Thyristor protection fuse Controlled phase Neutral Temperature controller EUROTHERM 2216 L N E V+ 1A 1B V- Firing indicator EUROTHERM ON - + 5V 1 2 1 TE10A 5 6 7 3 ε 2 4 3 4 Analogue output Thermocouple input Analogue input 5 6 7 0V + Example of wiring for TE10A (240V nominal, input 0 to 10V) controlled by Eurotherm 2000 series temperature controller. 12 Load Safety earth User manual TE10A

Local control by potentiometer The input must be configured as 0 to 5V (code 0V5). Local control by contacts The input must be configured as 0 to 5V (code 0V5). User manual TE10A 13

Auxiliary power supply (option) Use of TE10A with non-standard mains. Example of separate auxiliary power supply wiring (option). The auxiliary power supply must be in phase or in anti-phase with the load supply. 14 User manual TE10A

INPUT SIGNAL External control The TE10A is controlled by a DC analogue signal. Signal type: voltage (0 to 5V or 0 to 10V) or current (4 to 20mA). Input impedance: in voltage: 100k; in current: 250 ohms. Local control Local control is possible using a 10k potentiometer (analogue operation) or via dry contacts (logic operation). A '5V User' voltage output (terminal 7) is provided for these control modes (see wiring diagrams, page 13). The input must be configured for 0 to 5V (0V5) for local control. Input configuration (see pages 19 and 20 for Firing configuration) The signal type (voltage or current) and the signal level are configured in the factory by the Coffee beans located on the circuit board (see pages 19 and 20). The following table enables the user to check the configuration or to re-configure the TE10A if required. In this table, the x denotes the corresponding solder link ('Coffee bean'). Signal type Solder links ('Coffee beans') GR1 GR2 GR5 0-10V 0-5V x 4-20mA x x x Local control x User manual TE10A 15

FIRING MODES Three firing modes are possible: Burst firing, Single-cycle and advanced Single-cycle. Thyristor firing and quenching occurs at zero voltage which minimises interference to the supply network. Burst firing Burst firing mode consists of supplying a series of whole mains cycles to the load. The load power is proportional to the ratio of the firing time (T F ) to the modulation time (T M ). The OFF time (T NF ) is also a series of whole mains cycles. T M = T F + T NF The period of modulation is variable according to the output power demand. At 50% of nominal power the thyristors are on for 300ms ±100ms and are off for 300ms ±100ms (at 50 Hz) For a setpoint less than 50%, the non-firing period increases, and the firing period is fixed (300ms ±100ms) For a setpoint greater than 50%, the firing period increases, and it is the non-firing period which is fixed (300ms ±100ms) 16 User manual TE10A

Single-cycle The mode of firing with only one firing or non-firing mains cycle is called Single-cycle. At 50% of nominal power the thyristors are on for 20ms and are off for 20ms (at 50Hz) For a setpoint less than 50% the non-firing period increases and the firing period is fixed at 20ms For a setpoint greater than 50% the firing period increases and it is the non-firing period which is fixed at 20ms. User manual TE10A 17

Advanced Single-cycle (Uses different board) In order to minimise power fluctuation during the modulation period, the advanced Single-cycle mode uses half-cycles for non-firing. Examples of firing in Single-cycle (a) and in advanced Single-cycle (b) modes at 66.6% of nominal power. For a setpoint less than 50%, firing is effected on mains halfcycles. The firing time is fixed at one cycle (20ms at 50Hz) For a setpoint greater than 50%, non-firing is reduced to one halfcycle. Firing is effected over whole cycles. The use of half-cycles for non-firing is the reason for the reduction in flicker and brightness of infrared elements compared with Singlecycle. 18 User manual TE10A

CONFIGURATION OF FIRING MODE (see page 15 for Input configuration) The thyristor firing mode is configured by means of the 'Coffee beans' located on the circuit board. According to the firing mode, the TE10A is fitted with one of two boards: Board Type 1: Burst-firing or Single-cycle mode Board Type 2: Advanced Single-cycle mode Burst firing and Single-cycle (codes FC and FC1) In Burst-firing mode, Coffee beans GR4 and GR6 are soldered. In Single-cycle mode Coffee beans GR4 and GR6 are not soldered. Board Type 1 Positioning of Coffee beans on board Type 1 (solder-side view) User manual TE10A 19

Advanced Single-cycle (code SCA) Board Type 2, which provides advanced Single-cycle firing, is not reconfigurable as far as the firing mode is concerned. The information given below is intended for checking, if necessary, the configuration of the thyristor firing mode and input type, or for a possible change of input type. In advanced Single-cycle mode, Coffee bean GR8 must be soldered Coffee beans GR3, GR4, GR6, GR7 & GR9 must not be soldered Board Type 2 Positioning of Coffee beans on board Type 2 (solder-side view) 20 User manual TE10A

EUROTHERM CONTROLS LIMITED UK SALES OFFICE Eurotherm Controls Limited Faraday Close, Durrington Worthing West Sussex BN13 3PL TelephoneSales: (01903) 695888 Technical: (01903) 695777 Service: (01903) 695444 Fax (01903) 695666 Sales and support in over 30 countries worldwide For countries not listed overleaf enquiries/orders to: Eurotherm Controls Limited Export Dept., Faraday Close, Durrington, Worthing West Sussex, BN13 3PL Telephone (01903) 268500 Fax (01903) 265982 Telex 87114 EUROWG G

Solid State Contactors TE10S Power Controllers TE10A ε E U R O T H E R M ADDENDUM TE10S User Manual Part N : HA174780ENG, HA174782ENG, HA174784ENG, HA175436ENG TE10A User Manual Part N : HA175247ENG, HA175548ENG NOMINAL CURRENT UP TO 50 A and SHORT WAVE INFRARED APPLICATIONS Copyright Eurotherm Automation S.A. 1997 All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm Automation SA. Part N. HA175600 ENG - Issue 2.0-12/98

TECHNICAL SPECIFICATION MAXIMUM CURRENT In order to take into account supply voltage variations and heating element resistance dispersion (all types of heating elements including short wave infrared), a 0.8 safety coefficient must be used on the thyristor unit current rating to determine the maximum value of the load nominal current which the unit can safely control. SHORT WAVE INFRARED (SWIR) APPLICATIONS Applications using short wave infrared heaters in Single Cycle, Fast Cycle or Advanced Single Cycle are reserved to 16 A, 25 A and 40 A current rating. With a safety coefficient of 0.8 the maximum current for SWIR which can be controlled is: TE10 rating SWIR maximum controlled current 16 A 13 A 25 A 20 A 40 A and 50 A 32 A 2 Addendum TE10 (50A/SWIR)

RANGE DIMENSIONS AND WEIGHT Height 115 mm / Depth 92.5 mm Models Nominal current Width (mm) Weight (g) TE10S/DC, TE10S/AC TE10S/PDSIO 16 A 25 A 40 A 50 A 35 52.5 87.5 105 350 500 850 1100 TE10S/PLF TE10A/Burst TE10A/PA 16 A 25 A 40 A 50 A 52.5 70 105 122.5 550 700 900 1200 THYRISTOR PROTECTION FUSE TE10 rating 16 A 25 A 40 A 50 A Fuse rating 20 A 32 A 50 A 63 A Fuse & fuse-holder Code Dimensions(mm) FU1038/16A/00 81 x 17.5 x 68 FU1038/25A/00 81 x 17.5 x 68 FU1451/40A/00 95 x 26 x 86 FU2258/50A/00 140 x 35 x 90 Attention! Addendum TE10 (50A/SWIR) For SWIR applications, the high-speed fuse must not be used 3

60 I RMS (A) IN = 50 A 50 IN = 40 A 40 30 IN = 25 A 20 IN = 16 A 10 0 20 25 30 35 40 45 50 55 60 Operation tempereature ( C) Current derating as a fonction of ambient temperature (I N = nominal current at 45 C) Dotted line : limit due to recommended fuse 65 70 4 Addendum TE10 (50A/SWIR)