UPS. MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Similar documents
MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor MOD THREE-PHASE MODULAR UPS. up to 250 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL INFRASTRUCTURES

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

PowerValue 11/31 T kva

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specification SENTINEL PRO

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

EFFEKTA Power Supplies

Technical Data Sheets

POWER kva

POWER kva

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

ConceptpowerTM Modular kVA

Technical data sheets

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Power+ CLASSIC. 20/30 kva, 3x208 Vac

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

» Sophisticated» Reliable» Intelligent

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Technical data sheets

Master Plus kva

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Master DIALOG INDUSTRY RANGE

SENTINEL VA

MKN-DSP SERIES - THREE PHASE

1.1 GENERAL CHARACTERISTICS

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

YOUR POWER IN SAFE HANDS. E Series UPS

Technical Data Sheets

Technical Data Sheets

Master MPS kva kva 3:1 3:3 VFI TYPE

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Technical Data Sheets

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

TECHNICAL DATA SHEET KVA UPS Systemss

UNINTERRUPTIBLE POWER SUPPLY UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

POWERTRONIX QUASAR 5-40 KVA

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 120 kva kw

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

Master MPS kva kva 3:1 3:3 VFI TYPE

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

HAIRF UPS. X5 Series KVA

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 27 kw

TECHNICAL SPECIFICATIONS

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Via Somalia, Cormano (MI) - ITALY Ph Fax:

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Onfiniti. 1 Phase UPS

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Series 120/120VAC Universal Tower/Rack Mount

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

On-line, Single Phase, Double Conversion UPS

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

PowerScale TECHNICAL SPECIFICATIONS

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Master MPS kva kva 3:1 3:3 VFI TYPE

Master Plus kva

PowerWave 33 Efficient power protection for today s IT and process-related work environments

PowerScale kva Technical Specifications

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Transcription:

UPS MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to 10000 THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Modular UPS redundant and upgradable up to 10k with perfomance and functions at the top of their category MEGALINE modular single-phase They are available in three formats: - single cabinet; - double cabinet; - 19 inch rack. All models have a microprocessor control card that can be configured on the display, by modules ed by 1250 each, and by battery kits that contain no. 3x9Ah batteries. The single cabinet and 19 inch rack models issue a from 1250 to 5000, they can house a maximum of 4 boards and 4 battery kits. Additional batteries can be stored in specific cabinets, which can be easily connected thanks to an upgrading pre-setting. The range is completed with products made of two cabinets; the first cabinet can house up to 8 modules, each up to 1250, reaching a maximum of 10k. In the second cabinet it is possible to insert up to 10 battery kits and an additional battery charger. Other battery cabinets identical to the one supplied can be added in order to further upgrade. 2

MEGALINE Long table single and double cabinet version Model Power: Single Double Model Power: Rack no. cabinet and dimensions x H x D (mm) Codes 1.250 30 1 (6U) 3 103 87 1.250 52 1 (6U) 3 103 88 1.250 75 1 (6U) 3 103 89 2.500 22 1 (6U) 3 103 90 2.500 30 1 (6U) 3 103 91 2.500 52 2 (6U + 3U) 3 103 81 + 3 107 99 2.500 63 3 (6U + 2x3U) 3 103 81 + 3 107 99 + 3 107 96 3.750 18 1 (6U) 3 103 92 3.750 29 2 (6U + 3U) 3 103 83 + 3 107 98 3.750 44 3 (6U + 2x3U) 3 103 83 + 3 107 99 + 3 107 96 3.750 67 3 (6U + 3x3U) 3 103 83 + 3 107 99 (x2) 5.000 22 2 (6U + 3U) 3 103 85 + 3 107 97 5.000 30 2 (6U + 2x3U) 3 103 85 + 3 107 99 5.000 46 3 (6U + 3x3U) 3 103 85 + 3 107 99 + 3 107 98 5.000 63 4 (6U + 4x3U) 3 103 85 + 3 107 97 + 3 107 99 (x2) NOTE: values, expressed in minutes, are measured during optimal operating conditions. no. cabinet and dimensions x H x D (mm) 6U= 483 x 266 x 582 3U= 483 x 133x 584 Codes 1.250 30 1x (270 x 475 x 570) 3 103 73 1.250 52 1x (270 x 475 x 570) 3 103 74 1.250 75 1x (270 x 475 x 570) 3 103 75 2.500 22 1x (270 x 475 x 570) 3 103 76 2.500 30 2x (270 x 475 x 570) 3 103 77 2.500 52 2x (270 x 475 x 570) 3 103 52 + 3 107 78 2.500 63 2x (270 x 475 x 570) 3 103 52 + 3 107 79 3.750 18 1x (270 x 475 x 570) 3 103 78 3.750 29 2x (270 x 475 x 570) 3 103 54 + 3 107 77 3.750 44 2x (270 x 475 x 570) 3 103 54 + 3 107 79 3.750 67 2x (270 x 475 x 570) 3 103 54 + 3 107 82 5.000 22 2x (270 x 475 x 570) 3 103 56 + 3 107 76 5.000 30 2x (270 x 475 x 570) 3 103 56 + 3 107 78 5.000 46 2x (270 x 475 x 570) 3 103 56 + 3 107 81 5.000 63 2x (270 x 475 x 570) 3 103 56 + 3 107 84 5.000 22 2x (270 x 475 x 570) 3 103 60 + 3 107 80 5.000 30 2x (270 x 475 x 570) 3 103 60 + 3 107 82 5.000 46 3x (270 x 475 x 570)* 3 103 60 + 3 107 84 + 3 107 75 5.000 63 3x (270 x 475 x 570)* 3 103 60 + 3 107 84 + 3 107 78 6.250 20 2x (270 x 475 x 570) 3 103 63 + 3 107 81 6.250 30 2x (270 x 475 x 570) 3 103 63 + 3 107 84 6.250 47 3x (270 x 475 x 570)* 3 103 63 + 3 107 84 + 3 107 78 6.250 60 3x (270 x 475 x 570)* 3 103 63 + 3 107 84 + 3 107 81 7.500 18 2x (270 x 475 x 570) 3 103 66 + 3 107 82 7.500 30 3x (270 x 475 x 570)* 3 103 66 + 3 107 84 + 3 107 76 7.500 48 3x (270 x 475 x 570)* 3 103 66 + 3 107 84 + 3 107 81 7.500 59 3x (270 x 475 x 570)* 3 103 66 + 3 107 84 (x2) 8.750 20 2x (270 x 475 x 570) 3 103 69 + 3 107 84 8.750 30 3x (270 x 475 x 570)* 3 103 69 + 3 107 84 + 3 107 78 8.750 45 3x (270 x 475 x 570)* 3 103 69 + 3 107 84 + 3 107 83 8.750 61 4x (270 x 475 x 570)* 3 103 69 + 3 107 84 (x2) + 3 107 78 10.000 22 3x (270 x 475 x 570)* 3 103 72 + 3 107 84 + 3 107 76 10.000 30 3x (270 x 475 x 570)* 3 103 72 + 3 107 84 + 3 107 80 10.000 46 4x (270 x 475 x 570)* 3 103 72 + 3 107 84 (x2) + 3 107 76 10.000 60 4x (270 x 475 x 570)* 3 103 72 + 3 107 84 (x2) + 3 107 81 * The configuration requires the use a Y cable 3 108 60 (the number of cables required is equal to n cabinet -2) MEGALINE RACK Table of long uptimes 3.UPS.LEGRAND.COM

MEGALINE Modular single-phase UPS with double conversion VFI 3 108 57 Pack. Item Single - without batteries 3 103 51 1250 875-1 3 103 53 2500 1750-1 3 103 55 3750 2625-1 3 103 57 5000 3500-1 3 108 62 3 108 63 Double - without batteries 3 103 60 + 3 108 59 5000 3500-2 3 103 63 + 3 108 59 6250 4375-2 3 103 66 + 3 108 59 7500 5250-2 3 103 69 + 3 108 59 8250 6125-2 3 103 72 + 3 108 59 10000 3500-2 3 103 60 + 3 107 78 Pack. Item Single (German Standard) 3 108 35 eight 3 103 50 1250 875 13 1 23,5 3 103 52 2500 1750 13 1 34 3 103 54 3750 2625 13 1 43 3 103 56 5000 3500 13 1 53 Double eight 3 103 60 + 3 107 78 5000 3500 13 2 24+50 3 103 63 + 3 107 79 6250 4375 13 2 27+58 3 103 66 + 3 107 80 7500 5250 13 2 29+65 3 103 69 + 3 107 81 8250 6125 13 2 32+73 3 103 72 + 3 107 82 10000 7000 13 2 34+80 Single (French standard) eight 3 103 42 1250 875 13 1 23,5 3 103 43 2500 1750 13 1 34 3 103 44 3750 2625 13 1 43 3 103 45 5000 3500 13 1 53 Single (British standard) eight 3 103 46 1250 875 13 1 23,5 3 103 47 2500 1750 13 1 34 3 103 48 3750 2625 13 1 43 3 103 49 5000 3500 13 1 53 Battery expansions 3 107 75 with 1 kb 3 107 76 with 2 kb 3 107 77 with 3 kb 3 107 78 with 4 kb 3 107 79 with 5 kb 3 107 80 with 6 kb 3 107 81 with 7 kb 3 107 82 with 8 kb 3 107 83 with 9 kb 3 107 84 with 10 kb Battery expansion with battery charger 3 107 86 with 1 kb with battery charger 3 107 87 with 2 kb with battery charger 3 107 88 with 3 kb with battery charger 3 107 89 with 4 kb with battery charger 3 107 90 with 5 kb with battery charger 3 107 91 with 6 kb with battery charger 3 107 92 with 7 kb with battery charger 3 107 93 with 8 kb with battery charger 3 107 94 with 9 kb with battery charger 3 107 95 with 10 kb with battery charger Accessories 3 108 35 Power module (P 1250) 3 108 57 up-grade single cabinet (kb MegaLine/1) 3 108 58 up-grade double cabinet (kb MegaLine/2) 3 108 59 Empty battery cabinets 3 108 60 Y cable for connecting second additional battery cabinet 3 108 61 Kit with battery cabinet extension for tower configuration (PL MegaLine cable) 3 108 62 Manual bypass for single cabinet (BP/1) 3 108 63 Manual bypass for double cabinet (BP/2) 3 107 85 Additional battery charger (CB 36) 3 109 72 Relay interface kit NOTE: values, expressed in minutes, are measured during optimal operating conditions. 4

MEGALINE Modular single-phase UPS with double conversion VFI Item 3 103 42 3 103 46 3 103 50 3 103 43 3 103 47 3 103 52 3 103 44 3 103 48 3 103 54 3 103 45 3 103 49 3 103 56 3 103 60 + 3 107 78 3 103 63 + 3 107 79 3 103 66 + 3 107 80 3 103 69 + 3 107 81 3 103 72 + 3 107 82 Single CABINET Double CABINET General Features () 1250 2500 3750 5000 5000 6250 7500 8750 10000 () 875 1750 2625 3500 3500 4375 5250 6125 7000 Max expandability () 5000 10000 Max expandability () 3500 7000 Technology On-line double conversion (VFI-SS-111) UPS architecture Modular, Expandable, N+X Redundant with 1250 boards in a single cabinet Input Input nominal voltage 230 V Input voltage range 184 V 264 V at 100% of the load Minimum network operating voltage 100 V at 50% of the load THD Input current 3% Input Power Factor 0.99 from 20% of the load Input frequency 50 Hz / 60 Hz ± 2% autosensing Output Output voltage 230 V ± 1% Output frequency 50 Hz / 60 Hz synchronised THD Output voltage 1% with non-linear load aveform Sinusoidal Crest Factor 3,5 : 1 Performance when connected to the mains 92% at 100% of the load Allowed overload 300% for 1 sec. 200% for 5 sec. 150% for 30 sec. (min) 13 expandability Yes Equipment Bypass Static and Electromechanical, automatic and internally synchronised (due to overload or operating fault). Signals and Alarms Large 4-line alphanumeric display, multi-colour status indicator, audio signal Communication Ports no.1 RS 232 port, no.2 logical gates UPS Communicator Software Can be downloaded free of charge (after requesting the activation code) Electronic protections against overloads, short-circuits and excessive battery discharge. Operation stops when the ends. In-rush current limiter at start-up. Protections Sensor to connect the neutral cable correctly. Back-feed protection (electrical safety insulation of the input plug during battery-based operation). EPO contact (complete shutdown in the event of an emergency) IN/OUT mains connection Standard German / Clamp connector with universal multiple socket outlet (Italian/German standard) Mechanical features Net weight 23,5 34 43 53 24 + 50 26,5+57,5 29 + 65 31,5+72,5 34 + 80 Dimensions (H x x D) (mm) 475 x 270 x 570 2 x 475 x 270 x 570 Installed boards 1 2 3 4 4 5 6 7 8 Free expansion slots 3 2 1-4 3 2 1 - Installed battery kits 1 2 3 4 4 5 6 7 8 Free expansion slots 3 2 1-6 5 4 3 2 Environmental conditions Operating temperature ( C) 0 40 Degree of protection IP21 Relative humidity (%) 20 80 non-condensing Noise level at 1 m (dba) 40 Certifications Standards EN 62040-1, EN 62040-2, EN 62040-3 arranty Standard arranty 2-year warranty.ups.legrand.com 5

MEGALINE RACK Modular single-phase UPS with double conversion VFI 3 103 85 3 107 96 3 108 62 3 107 85 3 109 73 - ide input voltage and frequency range - Operational frequency at 50 or 60 Hz with auto-recognition - Frequency conversion 50 in - 60 out or vice versa - Extension of the input frequency range for operation with -supply units - Operation in eco mode (energy savings) - Operation in load waiting mode (on demand protection) - Adjustable output voltage in 1 volt steps from the front panel - Low noise level - Internal and external temperature measurement - Fan control based on temperature and load - Pre-set for emergency remote shut-off Pack. Item RACK (German standard) eight 3 103 79 1250 875 13 1 23,5 3 103 81 2500 1750 13 1 34 3 103 83 3750 2625 13 1 43 3 103 85 5000 3500 13 1 53 RACK (French standard) eight 3 103 34 1250 875 13 1 23,5 3 103 35 2500 1750 13 1 34 3 103 36 3750 2625 13 1 43 3 103 37 5000 3500 13 1 53 RACK (British standard) eight 3 103 38 1250 875 13 1 23,5 3 103 39 2500 1750 13 1 34 3 103 40 3750 2625 13 1 43 3 103 41 5000 3500 13 1 53 Pack. Item expansion KB additional Expansion 3 103 87 1250 1 30 3 103 88 1250 2 52 3 103 89 1250 3 75 3 103 90 2500 1 22 3 103 91 2500 2 30 3 103 92 3750 1 18 Battery expansions for UPS Rack 3 107 96 Rack with 1 kb 3 107 97 Rack with 2 kb 3 107 98 Rack with 3 kb 3 107 99 Rack with 4 kb 3 108 00 Rack with 1 kb with battery charger 3 108 01 Rack with 2 kb with battery charger 3 108 02 Rack with 3 kb with battery charger 3 108 03 Rack with 4 kb with battery charger Accessories 3 108 35 Power module (P 1250) 3 108 04 Empty battery rack cabinets 3 108 62 Manual bypass for single cabinet (BP/1) 3 107 85 Additional battery charger (CB 36) 3 109 72 Relay interface kit 3 109 73 Extendable Rack Guides Kit 6U NOTE: values, expressed in minutes, are measured during optimal operating conditions. 6

MEGALINE RACK Modular single-phase UPS with double conversion VFI Item 3 103 34 3 103 38 3 103 79 3 103 35 3 103 39 3 103 81 3 103 36 3 103 40 3 103 83 3 103 37 3 103 41 3 103 85 General Features () 1250 2500 3750 5000 () 875 1750 2625 3500 Max expandability () 5000 Max expandability () 3500 Input Technology UPS architecture Input nominal voltage Input voltage range Minimum network operating voltage On-line double conversion (VFI-SS-111) Modular, Expandable, N+X Redundant with 1250 boards in a single cabinet 230 V 184 V 264 V at 100% of the load 100 V at 50% of the load THD Input current 3% Input Power Factor Input frequency 0.99 from 20% of the load 50 Hz / 60 Hz ± 2% autosensing Output Output voltage 230 V ± 1% Output frequency THD Output voltage aveform 50 Hz / 60 Hz synchronised 1% with non-linear load Sinusoidal Crest Factor 3,5 : 1 Performance when connected to the mains Allowed overload 92% at 100% of the load 300% for 1 sec. 200% for 5 sec. 150% for 30 sec. (min) 13 expandability Yes Equipment Mechanical features Bypass Signals and Alarms Communication Ports UPS Communicator Software Protections IN/OUT mains connection Static and Electromechanical, automatic and internally synchronised (due to overload or operating fault) Large 4-line alphanumeric display, multi-colour status indicator, acoustic signal no.1 RS 232 port, no.2 logical gates Can be downloaded free of charge (after requesting the activation code) Electronic protections against overloads, short-circuits and excessive battery discharge. Operation stops when the ends. In-rush current limiter at start-up. Sensor to connect the neutral cable correctly. Back-feed protection (electrical safety insulation of the input plug during battery-based operation). EPO contact (complete shutdown in the event of an emergency) Standard German / Clamp connector with universal multiple socket outlet (Italian/German standard) Net weight 23,5 34 43 53 Dimensions (H x x D) (mm) 266 x 483 x 582 Installed boards 1 2 3 4 Free expansion slots 3 2 1 - Installed battery kits 1 2 3 4 Free expansion slots 3 2 1 - Environmental conditions Operating temperature ( C) 0 40 Degree of protection Relative humidity (%) IP21 20 80 non-condensing Noise level at 1 m (dba) 40 Certifications Standards EN 62040-1, EN 62040-2, EN 62040-3 arranty Standard arranty 2-year warranty 7.UPS.LEGRAND.COM

orld Headquarters and International Department 87045 Limoges Cedex - France : + 33 (0) 5 55 06 87 87 Fax : + 33 (0) 5 55 06 74 55 AD-EXLG/UPS-ME12B/GB - 10/2012