SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

Similar documents
SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

SPECIFICATIONS FOR GASOLINE ENGINE DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG

SPECIFICATIONS FOR GASOLINE ENGINE DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

SPECIFICATIONS FOR HYDRAULIC PTO DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG FIRE FIGHTING SYSTEM

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

Darley UHP-HV Diesel Specification 1

DANKO STOCK B DANKO XL SKID UNIT 250 Gallon UPF Defender Poly Tank

PyroLance B 2000 M-G Technical Manual

B-1125 DANKO STOCK. DANKO XL SKID UNIT UPF Defender Poly Tank

OPTIONS SLIP-ON FIREFIGHTING UNITS

Portable Pumps Transportable MaxStream Diesel Floating Pumps Pro Kit Skid and Trailer

B Pump Mounting. Page 1 of 7

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

STRIKERTM SERIES STRIKER-3 HIGH PRESSURE 3-STAGE FIRE PUMP. Features and Benefits. Applications DATA SHEET

BELL FIRE ENGINEERS PVT. LTD.

PARTS LIST FOR HDS SERIES (AFTER SERIAL # and # )

FOR YOUR SKID SPRAYER?

HIGH VELOCITY PUMP PUMP END

PARTS LIST FOR CBA MHB (AFTER SERIAL # ) CBA MVB

Priming Systems Installation Instructions

Illustrated Parts List to

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Solenoid Operated Block Valves A2800 Series

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

PARTS LIST FOR HDC SERIES (AFTER SERIAL # and # )

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES

BB-4 DIESEL BB-4-D902 VEHICLE MOUNT HIGH PRESSURE 4-STAGE FIRE PUMP. Applications. Features and Benefits DATA SHEET

VERSAX SERIES VERSAX SELF-PRIMING 2-STAGE FIRE PUMP PORTABLE & WRAP-AROUND. Applications. Features and Benefits DATA SHEET

PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SH22-20M

DARLEY PUMPS CAF SYSTEMS DAVEY PORTABLES DIESEL PORTABLE FAST ATTACK SKIDS

Albemarle County Virginia Brush Fire Truck Specification

MITSA INTERNATIONAL P.O.

The TR-Series are large volume,

32 quarts Transmission Allison HT 740 Automatic Fluid

HDC SERIES (AFTER SERIAL # )

PARTS LIST FOR HDB/HDD SERIES

PARTS LIST FOR CA MHB/RB (AFTER SERIAL # ) CA MVB

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

Illustrated Parts List to

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

8650 Enterprise Drive, Peosta IA / Fax PARTS LIST FOR JP MHB/VB

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

ERWC RM Shown with Optional Akron Brass Junction Box and Guide Roller

PRODUCT RELEASE CKMTA12 / 24

Hose & Apparatus Test Equipment

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF CONSERVATION & NATURAL RESOURCES BUREAU OF FORESTRY DIVISION OF FOREST FIRE PROTECTION

INSTALLATION AND USER MANUAL

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

FIRE KNAPSACK FIRE RESPONSE UNITS FIRE TRAILERS. Fire Fighting. Pages Designed to perform better.

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

PARTS LIST FOR CW MGH/V CW MGR (AFTER SERIAL # )

Car Wash / Pressure Washer

PARTS LIST FOR AIR COMPRESSORS AC-SH20-2 AC-SV20-2 ENGINE OIL GRADE: HONDA: SAE 10W-30. Below 40 F=SAE 10W-30 ENGINE OIL CAPACITY:

(800)

Illustrated Parts List

PARTS LIST FOR 4004 SERIES PORTABLE/ALUMINUM GASOLINE DRIVEN/BELT DRIVE COLD WATER PRESSURE WASHER

GENERAL PUMPA member of the Interpump Group

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

KJ Motor/Pump Assembly. Jetter. Printed in U.S.A. Ridge Tool Company/Elyria, Ohio, U.S.A.

PARTS LIST FOR HDB H6G HDB K7G

HL Series Centrifugal Fire Pumps Operation and Maintenance Instructions

4/3/2014 Ryobi Electronics Parts Catalog -- Ryobi Power Tools Consumer: [H301PL 3 Gallon Air Compressor (Husky)]/[Figure A]

PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SR14-30M AGW-SR14-B

D7G. Track-Type Tractor

PARTS LIST FOR CA MHB (AFTER SERIAL # ) Engine Oil Grade: SAE 10W-30 Engine Oil Capacity: 37 oz.

PISTON RING SET STANDARD 2-1

Illustrated Parts List Vanguard to Compliance

M-3025CB-AV Fuel Pump

8650 Enterprise Drive, Peosta IA / Fax BELOW 40 F=SAE10W-30 ENGINE OIL CAPACITY:

Illustrated Parts List

Genset. Parts Catalog GHAB. Parts Manual

Illustrated Parts List to

DD2T2. Engineering Data. Performance Bare Model Motor HP PSI RPM ACFM DD2T2 DD2T Bare Pump Detailed Specifications

Climas y Proyectos Leyco, S.A. de C.V.

HIGH-CAPACITY ADJUSTABLE WHEELBASE

PARTS LIST FOR CV MBC. Engine Oil Grade: Above 40 F=SAE 30 Below 40 F=SAE10W-30 Engine Oil Capacity: Pump Oil Capacity:

Illustrated Parts List to

(800)

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

OWNER S MANUAL. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/5.5 HP Engine, 4-Roller Pump & Deluxe Handgun) Assembly Instructions

PUMPERS CUSTOM AND COMMERCIAL. Discover Innovation. Experience Technology.

Table of Contents WARRANTY

SECTION HVAC POWER VENTILATORS

Illustrated Parts List

Disconnect the APP sensor harness connector. See Fig. 4. Remove the accelerator pedal mounting nuts. Remove the APP assembly.

Genset. Parts Catalog HDKAG

M-B Companies, Inc. Specification. Model 155. High Pressure Palletized Striper. High Pressure Airless. Options REV. 2.

KJ Motor/Pump Assembly. Jetter. Printed in U.S.A. Ridge Tool Company/Elyria, Ohio, U.S.A.

8650 Enterprise Drive, Peosta IA / Fax PARTS LIST FOR CW MGH/V. Below 40 F=SAE10W-30 Engine Oil Capacity:

Illustrated Parts List to

Racing Performance Catalog & Reference Guide Model/Type:

S/N 1H019H - 1H310H Page 1 of 33 46" Cutting Deck Assembly

rev 1_09/20/2017 PS-35C EA3500SR

University of Houston Master Construction Specifications Insert Project Name

Transcription:

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G Scope and General Design Requirements A firefighting system shall be provided for offensively attacking a fire. The high pressure firefighting system shall allow the operator to attack fire from a safe position. The system shall be extremely effective on wildland fire and initial fire attack operations with limited water supplies. Components and Module Design The firefighting system shall consist of: Engine: gasoline driven engine Water pump: high pressure positive displacement piston pump Hose Reel: high pressure hose reel and attack hose Nozzle: manually operated pistol grip high pressure nozzle

The major components shall be assembled on a removable assembly with integral engine. The entire system shall be designed to be a quickly installed or removable plug-and-play module. Safety and Standards Compliance The system shall be designed for the safety of the operator and fire fighter in mind with a safety margin of 4:1 built into all components. Performance Capabilities The firefighting system shall be tested and proven to be highly effective in the following scenarios: Wildland, grass, and brush fire applications Automobile and truck fires Limited structural fires Confined or concealed space fires Limited industrial fires Shipboard and marine firefighting Military firefighting applications Container fires ENCLOSURE MOUNTING The firefighting system shall be packaged in a self-supporting framework with dimensions of 30 (762 mm) right to left, 24 (610 mm) front to rear (deep), and 32 (813 mm) top to bottom. The mounting assembly shall be powder coated and shall be designed to contain the specified major components of the system. SLIDE-OUT TRAY A rollout equipment tray shall be installed in the specified compartment. The 600 lb. (272 kg) rated tracks shall have sealed roller bearings with steel angle framework. The unit shall roll fully out of the compartment, with a device to hold trays in both the "in and out" positions. A warning label shall be installed on the firefighting assembly "WARNING: slide tray must be extended for operation." The location of the tray shall be in compartment #. 2

ULTRA HIGH PRESSURE FIRE PUMP SPECIFICATIONS The firefighting system shall be equipped with a heavy duty high pressure plunger type positive displacement fire pump. The pump shall be driven as specified under the drive system section of these specifications. The pump shall have the following features: System operational rating: 10 gpm at 1450 psi (40 lpm at 100 bar) Solid Keyed Shaft Brass Manifold Stainless Steel Check Valve Stainless Steel Plunger Rods Bronze Connecting Rods Tapered Roller Bearings Solid Ceramic Plungers Heavy Duty Flat Base High Pressure Seals Heat Treated Crankshaft GEAR DRIVE SYSTEM SPECIFICATIONS The ultra-high pressure fire pump shall be equipped with a gear box drive system between the engine and the fire pump. The gear ratio shall be appropriate for the engine type to produce the specified fire pump performance. ENGINE INSTALLATION The firefighting system shall be powered by a Briggs and Stratton gasoline engine. The engine installation shall be designed with adequate cooling and ventilation air in the mounting area. The engine shall have the following specifications: Model: Vanguard Type: air cooled horizontal shaft Cylinder: one Horsepower: 13 (gross) RPM: 3,600 Oil filter and cooler Choke control Oil alert system 3

EXHAUST SYSTEM The fire pump engine shall have a muffler, water flip cover, heat guard, and exhaust pipe installed on the engine assembly. The exhaust pipe shall be directed vertically and away from the pump operator panel. GASOLINE FUEL TANK A built in plastic fuel tank shall be installed for the specified gasoline engine. The fuel tank shall have capacity of approximately 2.5 gallons (9 liters). A shut/off valve and flexible fuel line shall be furnished. ELECTRIC SUPPLY CABLE AND CONNECTION The 12 volt electrical power supply to the firefighting assembly from the chassis battery location shall use 30' (9 meter) flexible stranded copper wiring cables (positive (red) and neutral (black)) properly sized to the anticipated electric load. The installation kit shall be equipped with protective electrical loom, cable clamps, battery terminal connections, and plastic wrap ties for installation in the chassis. An automatic reset circuit breaker shall be supplied for installation at the truck battery location. The power supply cable shall be equipped with an Anderson type quick disconnect female and male receptacle plug. A firefighting pump instruction nameplate and necessary warning labels shall be installed on the assembly (English language). A fire pump engine shall be equipped with an hour meter and tachometer and shall be installed on the control panel. The fire pump engine oil drain shall be equipped with a 12 (300 mm) long wire braided hydraulic type hose, with valve, plug, and identification label. The pump control panel shall be provided with a 12 volt panel light with switch. PUMP CONTROL PANEL The control panel shall be ergonomically designed and operator friendly. The panel shall be labeled and installed to be easily visible from the operator s position. The following instruments and controls shall be installed: Emergency stop (red) switch Water on-off ball valve control Momentary contact two-position start-stop ignition switch Control panel light and switch One (1) UHP pressure gauge 4

Two (2) centrifugal fire pump intake and discharge gauges One (1) fire pump driven selector switch One (1) primer control PLUMBING The firefighting system shall be plumbed with high pressure hydraulic type hose, plumbing and fittings. This shall include double wire braided high pressure hoses of various sizes, zinc plated steel hose ends, and plated steel hydraulic fittings. The threads shall be male and female NPT, JIC and SAE O-ring style in various sizes. Rigid plumbing shall be in zinc plated steel piping with pipe fittings of zinc plated steel. BYPASS UNLOADER VALVE The ultra-high pressure plumbing system shall include a bronze adjustable by-pass unloading valve set for the maximum working pressure of the system. The valve shall unload the main pump to the intake side of the pump. PRESSURE SAFETY, EASY START, THERMAL RELIEF VALVE The ultrahigh pressure plumbing system shall include the following devices: A) one (1) pressure safety relief valve which shall relieve water pressure to atmosphere; set at a slightly higher pressure than the unloading valve. B) one (1) thermal relief valve which shall open if water temperatures exceed 145 F (62 C) degrees; designed to protect the pump from high temperature conditions and relieve the water to atmosphere. C) one (1) easy start valve INTAKE FILTER A 1" (25 mm) water filter with 32 mesh stainless steel screen shall be installed in the water supply line to the fire pump. The filter shall be accessible for cleaning the screen. The water filter shall be rigidly mounted. ELECTRICAL WIRING Necessary low voltage automatic circuit breaker protection shall be provided where required. Wiring shall be stranded copper automotive type, sized for the appropriate electrical load. Exposed wiring shall be protected with convoluted split plastic loom; such looms shall be mechanically secured. Wiring shall be run in protected areas or enclosed in metal panels where subject to mechanical injury. Electrical connections and termination of wiring shall be within weather proof plastic enclosures with waterproof strain relief's and connectors. 5

WATER TANK SUPPLY LINE A 1" (25 mm) water tank to fire pump line shall be installed as follows: a) From the fire pump to the water filter shall be a 1 (25 mm) flexible transparent hose. b) One (1) 1 (25 mm) two-way electric valve controlled on pump panel c) Fifteen feet (4 meters) of 1 (25 mm) flexible water hose with removable connections and clamping devices. One (1) 2.5 (65 mm) liquid filled pressure gauge shall be installed from the discharge side of the ultra-high pressure fire pump, with the gauge mounted on the pump panel. THROTTLE CONTROL The engine speed control shall be controlled by a mechanical throttle which shall automatically increase engine RPM speed when actuated and when released shall return the engine speed to idle. ELECTRIC HOSE REEL ULTRA HIGH PRESSURE One (1) painted ultra-high pressure steel hose reel shall be installed. The reel shall have leak proof ball bearing swing joint, positive pin locking device, electric 12 volt rewind provisions. The reel shall be plumbed with wire reinforced, high-pressure hose coupled with brass fittings. The reel system shall have a minimum of 4:1 safety ratio and designed for a 2,000 psi (138 bar) working pressure. The hose reel shall be installed by the installing agency. The high pressure hose reel shall be supplied by a 0.500 (12 mm) hydraulic type wire braided flexible hose line. One (1) push button electric rewind control shall be installed near the reel. The wiring from the hose reel electric box shall be protected with conduit or loom. The rewind button control shall be mounted in a sealed plastic electrical box. The hose reel shall be equipped with an electrical wiring junction box of plastic construction with a sealed cover assembly. The box shall house the reel solenoid, circuit breaker, and electrical wiring for the rewind control circuit and electric rewind motor power supply. The electrical supply shall be sized for the reel motor for both positive and neutral cables. The electrical supply wiring shall be supplied from the main electrical supply box for high pressure pump skid or module. The supply line to the reel shall have a quick disconnect connection (Anderson style plug) at the main electrical supply box. One (1) chrome plate hose roller assembly shall be supplied for protection of the hose during hose removal and rewind operations. 6

A positive pin type locking device shall be installed on the reel. REEL MOUNTED HIGH PRESSURE HOSE 150 foot (45 m) length x 3/4" (19 mm) hose shall be installed with threaded couplings. The hose shall have a working pressure of 3125 psi (215 bar). NOZZLE -- ULTRA HIGH PRESSURE One (1) 10 gpm (40 lpm) high pressure pistol grip fog nozzle shall be provided for the high pressure reel. 7

8