ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

Similar documents
SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

SYSTIMAX 360 FTP Evolve Panel Instructions

Fiber Connector Shelf (CCS)

UNPWM-U-Type Universal Wall Mount Patch Panel Instructions

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Opticom Rack Mount Fiber Enclosures

PATCHMAX GS3, GS6 and PowerSUM Modular Panels

UNP-U-Type Universal Panel Instructions

Universal Splice Tray Installation Instructions

8400 Series Fiber Distribution System

Environmental Distribution Center (EDC-06P-NH)

PanView iq (PViQ) Fiber Tray

INSTALLATION INSTRUCTIONS

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

FL2000 Termination/Splice Panels User Manual

Instructions for Use - Opt-X 1000i Enclosure

Installing the Switch

SW1 Swivel 1U Patch Panel

Engine 3 Installation

Copyright 2004 Alcatel. All rights reserved.

FOSC-400A4 INSTALLATION INSTRUCTION

SW1 Swivel 3U Patch Panel

Agilent G1554A On-Column Capillary Inlet with EPC

FIBER CONNECTOR SAFETY WARNINGS

SLIMRACK SLIDE-OUT MOTOR AND DRIVE BLOCK REPLACEMENT

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

5 Removal and replacement

Ortronics. Mighty Mo. GX Cabinets. Designed to Perform, Configured to Fit

BUDI-S-SP. Building distributor. Introduction. Seals. Kit content. Accessories. TC-957-IP Rev A, Feb Wrap around cable seals

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

LSW Connector Module User Manual

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

TOYOTA im INTERIOR LIGHT KIT Preparation

NISSAN #2744. Gross Trailer Weight (Maximum)...16,000 lbs. Vertical Load Weight (Max. Pin Weight)...4,000 lbs. SYSTEM TOW CAPACITY

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

Installation Guide. Flame Ionization Detector on a 6890 GC. Accessories G1561A, G1562A, G1591A, G1598A

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Fiber Optic Splice Module

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

Instruction, EDGE8-04U Quick Start Guide

CETAC Z-Drive Nylon Cable

I-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761

Fiber optic splice closure

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

INSTALLATION INSTRUCTIONS DODGE DAKOTA 2 KIT # 682 (2WD), 692 (4WD) 3 KIT # 683 (2WD), 693 (4WD)

Fiber Splice Panel Rack Mount User Manual

SYSTIMAX Solutions. Asia-Pacific Ordering Guide (03/14)

Overview. Chassis Packaging

CORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL

MODEL ELC-12/40-CVM-D BATTERY CHARGER

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M

COLD AIR INTAKE INSTALLATION INSTRUCTIONS. # D Fits: i (4.8L)

Used on 564 SS Gas Fireplaces Only. #8 x 3/8 Sheet Metal Screws. Upper and. Lower Grills. Heat Shield

Assembly and Modular Table Power System Installation Instructions for Train Tables

LC Cable Assemblies. Fiber Optic Products Catalog. Product Facts. LC Cable Assembly. Hybrid LC-SC Cable Assembly

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

2-row and All-row systems included.

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

2015 Mustang Lightbar (All Models) CDC#

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

Base Power Infeed Installation for Training Tables with Modular Table Power System

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Installation Guide. Purged Packed Inlet, Electronic Pneumatics Control on 6890 GC Accessory G1551A

RFB MK6 Jetta Fog Light Kit Wiles Rd.Coral Springs, FL

BLACKBIRD INSTALLATION SUPPLEMENT

ENC-560 Autosampler Enclosure

Carousel Unit User Manual Replacing the Check Stand Motor

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

Installation Instructions Pro Bandit Shifter Fits: GM Powerglide Automatic Transmissions

MIGHTY MO CABLE MANAGEMENT SYSTEM

INSTALLATION & OWNER S MANUAL

SUT-450-I ASSEMBLY REQUIREMENTS

Z1 Motorsports 370Z/G37 Oil Cooler Kit Installation Manual

I-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING

920 Remote Control Switches

LX2 High Density LGX 4U Patch Panel

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions

AGCO. Corn Header Manual d HEADSIGHT.COM

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

Technical Support (707)

Auto-Lift Operating System

Signal Mirror Installation Instructions

OFS Assembly Instructions Instruction Sheet for LC Comcode: Fiber Optic Behind-The-Wall (BTW) Connectors

This instruction sheet covers the installation of the Fiber Optic 200A Interconnection Unit, which includes LaserWave Applications.

ALTITUDE ARMS AND CANOPY

FOSC-100 B/H FOSC-100 B2/H

LX2 High Density LGX 4U Patch Panel

Transcription:

Instruction Sheet 860463090 Issue 3, December 2012 SYSTIMAX Solutions ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions General These instructions describe how to install ipatch Ready Upgrade Kit to convert standard SYSTIMAX 360 G2 fiber shelves and InstaPATCH 360 fiber shelves to ipatch Fiber Shelves. These instructions address conversion of both sliding and fixed shelves. The ipatch Ready Upgrade Kit is a SYSTIMAX approved product. Ordering information is listed below: Material ID Part No. Description 760105148 360-iP-UP-KIT-G2-LC ipatch Ready Upgrade Kit How to Contact Us To find out more about CommScope products, visit us on the web at http:/// For technical assistance: Tools Required - Within the United States, contact your local account representative or technical support at 1-800-344-0223. Outside the United States, contact your local account representative or Authorized Business Partner. - Within the United States, report any missing/damaged parts or any other issues to CommScope Customer Claims at 1-866-539-2795. Outside the United States, contact your local account representative or Authorized Business Partner. T10 Torx driver Important Safety Cautions To reduce the risk of fire, electric shock, and injury to persons, read, understand, and adhere to the following instructions as well as any warnings marked on the product. Remote risk of electric shock. Never install the product in wet locations or during lightning storms. Never touch uninsulated communication wires or terminals. Disconnected optical components may emit invisible optical radiation that can damage your eyes. Never look directly into an optical component that may have a laser coupled to it. Serious and permanent retinal damage is possible. If accidental exposure to laser radiation is suspected, consult a physician for an eye examination. This product is covered by one or more of the following U.S. patents or their foreign equivalents: 6,285,293 and 6,522,737. 2012 CommScope, Inc. All rights reserved For RoHS Inquiries: CommScope Inc. Corke Abbey, Bray Co. Dublin, Ireland Attn: Legal Department Page 1 of 10

860463090 Instruction Sheet Wear safety glasses to install the shelf. Although standard safety glasses provide no protection from potential optical radiation, they offer protection from accidental airborne hardware and cleaning solvents. Precautions ipatch high density fiber modules contain fiber optic cable and passive optical components. When removed from protective packing, they should be handled carefully and installed in appropriate racks for mechanical support and protection. ipatch high density fiber modules require virtually no maintenance to maintain their performance. They contain no user-serviceable components, and any damage to the anti-tamper label or removal of top cover or front adapter mounting panel will void the warranty. Fiber optic trunk cable and jumper performance is sensitive to bending, pulling, and crushing. Minimum bend radius must be maintained during installation per the manufacturer s specification. Appropriate pulling socks must be used during installation, and pulling forces shall not exceed manufacturer s recommendations. MPO terminated trunk cables may use ribbonized fiber optic cable, which has a preferential bend axis. Use caution to avoid kinking trunk cables. Prior to installation, clean the trunk cable and jumper connectors per the manufacturer s recommendations. All wiring that connects to this equipment must meet applicable local and national building codes and network wiring standards for communication cable. Care should be taken not to compromise the stability of the rack by installation of this equipment. This shelf is for use in restricted access areas only. IMPORTANT SYSTIMAX 360 ipatch Ready Upgrade Kits use infrared sensing technology and should be installed where they are not exposed to direct sunlight or other infrared sources. Save these instructions. Overview To convert a rack with standard SYSTIMAX 360 fiber shelves to SYSTIMAX 360 ipatch fiber shelves for use with an ipatch system, you must perform the following steps: Step 1. Step 2. Step 3. Step 4. Mount a panel bus for the rack. Install an ipatch Manager to supervise the rack. Install ipatch Ready Upgrade Kits to convert SYSTIMAX 360 fiber shelves for use with the ipatch system. Program the order of the panels in the rack. Step 1 Mount the Panel Bus A panel bus must be installed on each rack where you plan to upgrade shelves. The panel bus allows the ipatch Manager and ipatch shelves to communicate. Also, the ipatch Manager supplies power to the ipatch shelves through the panel bus. Page 2 of 10

860463090 Issue 3, December 2012 The panel bus must be installed to the left on the rack (viewed from the front). The preferred location is the back corner of the rack s left rail. The area where the panel bus will be mounted must be free of protrusions, such as threaded inserts, nuts, and bolts. Note: To mount the panel bus on a rack other than a 7-foot rack or on a rack with a hole pattern other than the universal hole pattern, contact your SYSTIMAX Solutions local account representative. For instructions to install the panel bus for the rack, see the SYSTIMAX ipatch System Panel Manager Guide (860442573). Step 2 Install the ipatch Manager An ipatch Manager must be installed on each rack where you plan to upgrade shelves. The ipatch Manager supervises the ipatch panels in the rack and communicates with the ipatch system. For upgrade applications, we recommend using a Panel Manager. We recommend mounting the Panel Manager in the 34th 1U slot up from the bottom of the rack so that the top of the unit is about 65 inches above the floor. For instructions to install and configure the Panel Manager, see the SYSTIMAX ipatch System Panel Manager Guide (860442573). Step 3 Upgrade the Fiber Shelves Before you upgrade the shelves in the rack, you must remove power from the Panel Manager for the rack. Note: For instructions to upgrade a SYSTIMAX 360 1100 type panel, see the ipatch Ready Upgrade Module for SYSTIMAX 360 1100 Type Panels Instruction Sheet (860458421). Preparing the Shelf 1. Remove power from the rack s Panel Manager. 2. If the shelf is a sliding shelf, fully extend the shelf from the rack. 3. Open the door on the patch cord trough by gently pressing both upper corners to release the latches. Open the door to 45 and lift the door off the trough. Figure 1 Removing the Door from the Patch Cord Trough Page 3 of 10

860463090 Instruction Sheet 4. Slide the plastic cover off the shelf. Figure 2 Removing the Plastic Cover from the Shelf 5. If the shelf has G2 modular cassettes, remove the hinged dust covers from the cassettes. Note: To remove a hinged dust cover, open the cover and pull it straight off the top of the cassette. Figure 3 Removing the Hinged Dust Covers from G2 Modular Cassettes 6. If the shelf has InstaPATCH modules: Use your fingers to pry the color-coded plastic frame off the front of each module. You can use pliers with a cutter or a similar tool to cut the frames and remove them from the patch cords. Discard the frames. Note: To determine the orientation of a module after its frame has been removed, look at the back of the module. If ALPHA is right reading (not upside down), the module is in the ALPHA orientation. If BETA is right reading, the module is in the BETA orientation. Figure 4 Removing the Plastic Frames from InstaPATCH Module On the ipatch Ready Upgrade Kit, apply one of the color-coded labels provided to the opening for each module. Place the label just above the labeling area for the ports (Figure 5). Page 4 of 10

860463090 Issue 3, December 2012 Use the same label color as the color of the plastic frame that you removed. The table below shows the fiber type corresponding to each color. Color Aqua Beige Green Blue Fiber Type Multimode with 50 µm core diameter LazrSPEED Multimode with 62.5 µm core diameter OptiSPEED Singlemode with 8.3 µm core diameter & APC connection TeraSPEED Singlemode with 8.3 µm core diameter TeraSPEED Installing the Panel Bus Jumper Figure 5 Applying the Fiber Type Labels for each Module 1. Install two flat cable retainers inside the shelf in the locations shown (Figure 6). Figure 6 Installing the Cable Retainers Inside of the Shelf 2. If the shelf is a sliding shelf: Install one cable retainer clip on the inside of the sliding rail as shown (Figure 6). Install one flat cable retainer and one cable retainer clip on the outside of the sliding rail as shown (Figure 7). Figure 7 Installing the Flat Cable Retainer and Cable Retainer Clip on the Sliding Rail Page 5 of 10

860463090 Instruction Sheet 3. If the shelf is a fixed shelf, install one flat cable retainer on the outside of the shelf as shown (Figure 8). Figure 8 Installing the Flat Cable Retainer on the Outside of the Shelf 4. Feed the end of the panel bus jumper with the small connector from the outside of the shelf through the small rectangular opening in the back, left corner of the shelf (viewed from the front). 5. Position the end of the panel bus jumper with the small connector into the slot in the top, center face of the panel, feeding about two inches of the jumper through the slot. 6. Secure the panel bus jumper in the flat cable retainers inside the shelf as shown. Figure 9 Positioning the Panel Bus Jumper Inside the Shelf 7. If the shelf is a sliding shelf, install the corrugated tubing: Place the corrugated tubing on the portion of the panel bus jumper extending out the back of the shelf. Snap the tubing into the cable retainer clip on the inside of the sliding rail as shown (Figure 10). Snap the tubing into the cable retainer clip on the outside of the sliding rail as shown (Figure 10). Page 6 of 10

860463090 Issue 3, December 2012 Note: Position the corrugated tubing so that about 1 inch (2.5cm) of the tubing extends past the end of the cable retainer. Make sure the tubing is positioned so that it protects the portion of the panel bus jumper routed around the end of the sliding rail. Figure 10 Positioning the Panel Bus Jumper Outside the Shelf (Top View) 8. Secure the exposed ribbon cable of the panel bus jumper in the flat cable retainer on the outside of the sliding rail as shown (Figure 10). Important: Be careful not to disturb the fiber cables inside the shelf. 9. Connect the panel bus jumper to the nearest connector on the panel bus. Note: The connector is keyed. The polarized tab on the jumper connector fits into the opening in the header connector on the panel bus. Important: Make sure that the jumper connector is fully seated in the header connector on the panel bus. Figure 11 Connecting the Panel Bus Jumper to the Panel Bus Page 7 of 10

860463090 Instruction Sheet 10. If the shelf is a fixed shelf, feed the excess panel bus jumper into the shelf as shown. Feed the excess panel bus jumper into the shelf Figure 12 Feeding Excess Panel Bus Jumper into the Fixed Shelf Installing the ipatch Ready Upgrade Kit 1. Align the ipatch Ready Upgrade Kit with the front of the panel, arranging the patch cords as shown (Figure 13). Then, connect the panel bus jumper to the back of the kit. Figure 13 Aligning the Upgrade Kit and Connecting the Panel Bus Jumper 2. Place the ipatch Ready Upgrade Kit on the front of the panel, aligning the captive screws with the corresponding holes in the panel. Page 8 of 10

860463090 Issue 3, December 2012 3. Starting with the center screw, use a T10 Torx driver to tighten the nine captive screws and secure the kit to the panel. Note: Use a dedicated T10 Torx driver. Drivers with interchangeable bits are too wide to access the screws. Important: Make sure the kit is fully seated on the front of the panel. Tighten the screws until snug. Completing the Installation Figure 14 Tightening the Mounting Screws 1. Slide the cover through the flanges on the shelf until the cover reaches the back wall of the shelf. Figure 15 Installing the Cover on the Shelf 2. With the trough door at a 45 angle to the patch cord trough, guide hinge pins on inside edges of door into hinge sockets on outer edges of trough floor (Figure 16). Swing the door to the closed position, gently pressing the upper corners to latch the door. Page 9 of 10

860463090 Instruction Sheet Figure 16 Installing the Door on the Patch Cord Trough 3. Install dust covers on any ports that are not being used for patch connections. Note: The dust covers protect the fibers connected to the back of the faceplate. The dust cover should remain on a port until you connect a patch cord to that port. If you remove a patch cord later, replace the dust cover in the port. 4. If the shelf is a sliding shelf, fully retract the shelf in the rack. Step 4 Programming the Order of Panels After you have upgraded the shelves in the rack, you should restore power to the Panel Manager for the rack and program the order of the panels. For instructions, see the SYSTIMAX ipatch System Panel Manager Guide (860442573). Page 10 of 10