JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Similar documents
JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

JUMO MIDAS S05 Pressure transmitter Type

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Pressure Transmitter JUMO dtrans p30 Type

Pressure Transmitter JUMO dtrans p30 Type

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO MIDAS Pressure transmitter

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Pressure transmitter for elevated media temperatures

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Pressure transmitter JUMO dtrans p02

JUMO dtrans p20 DELTA

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors

MBS 1200 and MBS 1250

Pressure transmitter for industrial applications Type MBS 4510

Screw-in resistance thermometers with plug connector

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Beck. The differential pressure transmitter for air with IP65

Pressure transmitters for industrial applications Type MBS 4510

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Electronic pressure switch with integrated analogue output

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

J TS 7090 Thyristor power switch

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

OEM Pressure Transmitters

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

JUMO heattherm Type a Protection temperature limiter, as a panel-mounting thermostat a Compensated for ambient temperature

Type A-10 General Purpose Pressure Transmitters

Pressure transmitter for industrial applications Type MBS 4500

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Pressure transmitters for heavy duty applications MBS 3200 and 3250

JUMO MIDAS S05 OEM pressure transmitter - universal

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

OEM Pressure Transmitters

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Pressure transmitters for heavy duty applications Type MBS 3250

Differential Pressure Sensors

Pressure Sensors. for liquid and gaseous media

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

Electronic pressure switch with two switching outputs

PSG5xx ATM to Medium Vacuum Gauge

SITRANS P measuring instruments for pressure

SPT- I / U PRESSURE TRANSMITTER for general applications

Industrial Pressure Transmitter

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Pressure transmitter for marine applications Type MBS 5100 and MBS 5150

DMP 331. Industrial Pressure Transmitter for Low Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Differential Pressure Sensors

2-Color Display High-Precision Digital Pressure Switch

Technical Datasheet P-30/P-31. Standard transmitter.

Pressure transmitter for marine applications MBS 33M

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

ECT Applications. Features

Thermostats for panel mounting Series ETH

SATRON VTe pressure transmitter

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

DMP 333. Industrial Pressure Transmitter For High Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

Analog input module. Brief description. Page 1/8. Data Sheet

Type A-10 General Purpose Pressure Transmitter

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Differential pressure sensor

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Differential Pressure Sensors

Pressure Transmitters for Sanitary Applications Model SA-11

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Temperature Sensor without thread

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

Pressure transducer DMU 01K Compact version

Industrial Pressure Transmitters

JUMO ecotrans Lf 01/02

EPI Applications. Features

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Explosion-protected surface-mounting Thermostat ATH-Ex Series

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Transcription:

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page / JUMO MIDAS S06 OEM-Pressure Transmitter Low Pressure Applications HVAC (heating, ventilating, and air conditioning) Filter technology Mechanical and plant engineering Level measurement Bubble-through method Packaging industry Brief description The JUMO MIDAS S06 pressure transmitter is already available with measuring ranges as of 00 mbar. The used silicon sensor can handle extreme overloading even in the lowest measuring ranges and is capable of handling millions of pressure cycles. The fully welded and therefore seal-free measuring system made of high-grade stainless steel allows this device to be used in almost all media, even when the conditions are rough. The structure ensures optimum protection against process medium leakage. Type 00 with cable socket Type 00 with M connector Customer benefits Economic A high degree of automation (digital compensation and calibration of sensor module) reduces production time and manufacturing costs. Process reliability The piezoresistive silicon sensor has a high level of overload protection and long-term stability. The full final inspection in the fully automated measuring and calibration facility ensures that each pressure transmitter is of high quality. Time-saving, uncomplicated, and versatile The installation of the measuring device requires little work and the electrical installation is simple. The modular structure allows universal use in almost any application. Special features Measuring ranges as of 00 mbar Suitable for measuring aggressive liquids High degree of process reliability due to a welded measuring system with no seals Robust and maintenance-free measurement technology thanks to extreme overload resistance 60 % quicker device installation with the QUICKON quick-clamp technology Parts in contact with media are made of stainless steel V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page / Technical data General Information Reference conditions DIN 6086 and DIN EN 60770 Sensor Material Silicon sensor with stainless steel separating membrane (piezo-resistive) Pressure transfer medium Synthetic oil Admissible load changes > 0 million Position Mounting position Any Calibration position Device stands upright, process connection at the bottom Zero point offset depending on position.5 mbar, process connection at the top Output Analog output a Current Output 05 to 0 ma, two-wire Voltage Output DC 0.5 to.5 V, three-wire, ratiometric 0 to 90 % of the voltage supply Output 5 DC 0 to 0 V, three-wire Output 8 DC to 5 V, three-wire Output 0 DC to 6 V, three-wire Step response T 90 5ms Burden Current R L (U B -8 V) 0.0 A (Ω) to 0 ma, two-wire Voltage DC 0.5 to.5 V, three-wire R L 5kΩ DC 0 to 0 V, three-wire R L 0 kω DC to 5 V, three-wire R L 0 kω DC to 6 V, three-wire R L 0 kω a Further outputs are available upon request. V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page / Mechanical features Process connection Material Stainless steel 0 a Push-in fitting Brass, nickel-plated (process connection 8) Membranes Material Stainless steel 6 L Case Material Stainless steel 0 Electrical connection Material Attached cable PBT-GF0, PVC, PE (electrical connection ) QUICKON PBT-GF0 (electrical connection ) Round plug M PBT-GF0, stainless steel 0 (electrical connection 6) Bayonet connector PBT-GF0 (electrical connection 5) Cable socket PBT-GF0, PA, silicone (electrical connection 6) Weight 80 g with process connection 50 (G /) a Pressure transmitters with process connection 5 are supplied with an FPM seal. Note the medium durability of the seal material! V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page / Environmental conditions Admissible temperatures Measuring range 00, 60, 50, - Measuring range 0, bar 00 to +00 mbar Medium 0 to 80 C -0 to +00 C Ambient 0 to 80 C -0 to +00 C Storage -0 to +00 C -0 to +00 C Admissible humidity Operation 00 % rel. humidity including condensation on the device outer case Storage 90 % rel. humidity without condensation Admissible mechanical load Vibration resistance a 0 g at 0 to 000 Hz Shock resistance b 50 g for ms 00g for ms Electromagnetic compatibility Interference emission c Class B Interference immunity c Industrial requirement Protection type d Attached cable (electrical connection ) Relative pressure measuring range IP66 Absolute pressure measuring range IP67 QUICKON e IP66 (electrical connection ) Round plug M f IP66 (electrical connection 6) Bayonet connector f IP67 (electrical connection 5) Cable socket f, g IP65 (electrical connection 6) a IEC 60068--6 b IEC 60068--7 c EN 66-- d EN 6059 e Connecting cable diameter, minimum.5 mm, maximum 6 mm f The protection type is only achieved with a suitable mounted counter piece. g Connecting cable diameter, minimum 6 mm, maximum 8 mm V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page 5/ Measuring range and accuracy Measuring range Linearity a Accuracy at Long-term Overload Burst 0 C c -0to+00 C d (80 C) stability b capacity pressure mbar % MSP e % MSP % MSP % MSP bar bar per year 0 to 00 mbar relative pressure 0.5. f <.0-0. to +0. -0.6 to +0.6 0 to 60 mbar relative pressure 0. 0.8.9 f -0.7 to +0.7 - to + 0 to 0,5 bar relative pressure 0. 0.8.8 f - to + - to +.5 0 to 0, bar relative pressure 0. 0.7.7 < 0. - to +.6 - to + 0 to 0,6 bar relative pressure 0. 0.7.6 - to +. - to +.6-00 to +00 mbar relative pressure 0. f -0. to +0. -0.6 to +0.6-00 to +00 mbar relative pressure 0. 0.7.7 - to +.6 - to + a Linearity according to limit point setting b Reference conditions EN 698- c Includes: linearity, hysteresis, repeatability, deviation of measuring range initial value and measuring range end value d Includes: linearity, hysteresis, repeatability, deviation of measuring range initial value and measuring range end value, thermal effect on measuring range start and measuring span e MSP = measuring span f Maximum admissible ambient and medium temperature 80 C Auxiliary energy Voltage supply U B a to 0 ma, two-wire (output 05) DC 8 to 0 V, rated voltage supply DC V DC 0.5 to.5 V, three-wire (output ) DC to 5.5 V, rated voltage supply DC 5 V, ratiometric output 0 to 90 % of the voltage supply DC 0 to 0 V, three-wire (output 5) DC.5 to 0 V, rated voltage supply DC V DC to 5 V, three-wire (output 8) DC 8 to 0 V, rated voltage supply DC V DC to 6 V, three-wire (output 0) DC 8 to 0 V, rated voltage supply DC V Current consumption to 0 ma, two-wire (output 05) 5 ma DC 0.5 to.5 V, three-wire (output ) ma DC 0 to 0 V, three-wire (output 5) ma DC to 5 V, three-wire (output 8) ma DC to 6 V, three-wire (output 0) ma Reverse voltage protection Yes Electrical circuit SELV Requirements The device must be equipped with an electrical circuit that meets the requirements of EN 600- with regard to "Limited-energy circuits". a Residual ripple: the voltage peaks must not exceed or fall below the specified voltage supply values! V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page 6/ Dimensions Electrical connection Attached cable QUICKON 6 Round plug M 5 Bayonet connector 6 Cable socket V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page 7/ Process connection 8 Push-in fitting tube/hose 6 DN 6 50 G/8 50 G/ 8 ø.5 ø ø8 G/8 50 G/ 5 /-8 NPT 5 G/ 9 Ø.5 Ø.5 Ø.5 ** /-8 NPT * G/ ø6 ø7.5 G/ 6 5 0 A ** 57 Rp /8 inside 56 7/6-0 UNF 56 7/6-0 UNF inside 0 Ø 7 9 Rp /8 M6.5 Ø 9.5.5 Ø 9.5 7/6-0 UNF.5 Ø.5 7 7/6-0 UNF Ø 7 B A Profile seal G / B With valve core handle * With extra code 60 pressure channel Ø mm ** With extra code 60 pressure channel Ø 8 mm V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page 8/ Accessories Part no. 0057866 Mounting example Part no. 0057866 V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page 9/ Connection diagram The connection diagram in the data sheet provides preliminary information about the connection options. For the electrical connection, only use the installation instructions or the operating manual. The knowledge and the correct technical compliance with the safety information and warnings contained in these documents are mandatory for mounting, electrical connection, and startup as well as for safety during operation. Connection Terminal assignment a Attached cable QUICKON 6 Round plug M to 0 ma, two-wire (output 05) Voltage supply DC 8 to 0 V U B /S+ 0V/S- WH BN DC 0.5 to.5 V ratiometric (output ) Voltage supply DC to 5.5 V U B WH Ratiometric output 0 to 90 % of the voltage supply 0V/S- BN S+ GN DC 0 to 0 V, three-wire (output 5) Voltage supply DC.5 to 0 V U B WH 0V/S- BN S+ GN DC to 5 V, three-wire (output 8) DC to 6 V, three-wire (output 0) Voltage supply DC 8 to 0 V U B WH 0V/S- BN S+ GN Functional bonding conductor FB b - - - 5 Bayonet connector 6 Cable socket a b Figure: connection to the pressure transmitter The pressure transmitter has to be connected to the potential equalization system of the plant through the electrical connection or process connection. V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page 0/ Assignment variants electrical connection, extra code 9 Please provide the assignment variant in plain text with the order details (for example "B")! Connection Terminal assignment a 6 Round plug M Assignment variants B B B B to 0 ma, two-wire (output 05) Voltage supply DC 8 to 0 V U B /S+ 0V/S- DC 0 to 0 V, three-wire (output 5) Voltage supply DC.5 to 0 V U B 0V/S- S+ DC to 5 V, three-wire (output 8) DC to 6 V, three-wire (output 0) Voltage supply DC 8 to 0 V U B 0V/S- S+ Functional bonding conductor FB b - - - 6 Cable socket a b Figure: connection to the pressure transmitter The pressure transmitter has to be connected to the potential equalization system of the plant through the electrical connection or process connection. Color coding: connecting cable round plug M BN Brown WH White BU Blue BK Black The color coding is only valid for A-coded standard cables! V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page / Order details a b () Basic type 00 JUMO MIDAS S06 - OEM pressure transmitter for low pressure () Basic type extension 000 None 999 Special version () Input 0 to 00 mbar relative pressure 5 0 to 60 mbar relative pressure 6-00 to +00 mbar relative pressure 7-00 to +00 mbar relative pressure 5 0 to 0,5 bar relative pressure 5 0 to 0, bar relative pressure 5 0 to 0,6 bar relative pressure 999 Special measuring range for relative pressure () Output 05 to 0 ma, two-wire DC 0.5 to.5 V, three-wire, ratiometric 5 DC 0 to 0 V, three-wire 8 DC to 5 V, three-wire 0 DC to 6 V, three-wire 999 Special version (5) Process connection 8 Push-in fitting for pipe/hose 6 DN 6 50 G /8 according to DIN EN 87 50 G / according to DIN EN 87 50 G / according to DIN EN 87 5 /-8 NPT according to DIN EN 87 5 G / according to DIN 85-57 Rp /8 inside 56 7/6-0 UNF 56 7/6-0 UNF inside, with valve core handle 999 Special version (6) Process connection material 0 CrNi (stainless steel) (7) Electrical connection Attached cable a QUICKON 6 Round plug M 5 Bayonet DN 7585-A-.-Sn/K 6 Cable socket DIN EN 750-80, Form A, ex DIN 650 99 Special version (8) Extra codes 000 None 59 Choke in the pressure channel 6 Oil and grease free 60 Enlarged pressure channel b 9 Assignment variant electrical connection The standard cable length is m. Further lengths are available upon request. Diameter 8 mm with process connection 5 and 5, diameter mm with process connection 50 V.00/EN/005559 0000T0Z00K000

Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road East Syracuse, NY 057, USA Phone: + 5 7 5866 Fax: + 5 7 5860 Data Sheet 00 Page / () () () () (5) (6) (7) (8) Order code / - - - - - /,... a Order example 00 / 000-5 - 05-50 - 0-6 / 59 a List extra codes in sequence, separated by commas. Minimum order volume for manufacturing devices: Minimum order volume for warehouse devices: 5 pieces piece Accessories Item Description Part no. Cable box, straight The PVC connecting cable is m in length and has a -pin, straight M 000585 connector with gold-plated contacts on the device side. Cable box, angled The PVC connecting cable is m in length and has a -pin, angled M connector with gold-plated contacts on the device side. 0009 Mounting set (bracket and fixing nut for process connection 57) 0057866 V.00/EN/005559 0000T0Z00K000