HQ Series ¼ Turn Electric Actuator

Similar documents
HQ Series ¼ Turn Electric Actuator

HQ-006 ¼ Turn Actuator

Installation, Operation and Maintenance Manual

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

Installation, Maintenance and Operation Manual

Installation and Operating Manual

AE Installation Operation & Maintenance Instructions

Installation Instructions

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

Series 10 Actuator. Installation, Operation and Maintenance Manual

EW 350 ELECTRIC ACTUATOR INSTALLATION, MAINTENANCE AND OPERATION MANUAL

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Series Village Lane Easley, SC Ph: (864) Fax: (864) Worm and Spur Gear Electric Actuators

NOAH ACTUATOR NA-SERIES MANUAL EMICO EUNHA MACHINERY INDUSTRIAL CO.,LTD.

LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

MAQ Series Electric Actuator

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

LUF Series Unidirectional Electric Actuators

Quarter Master Series 94 Actuator

VALVCON. QX-Series ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

SERIES 1000 ELECTRIC ACTUATORS

Surepowr Series 100 Installation Manual

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

PNEUMATIC ACTUATORS. Linear acting

A Compact and Reliable Quarter-Turn Electric Actuator

Motorized Butterfly Valve

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

Actuated Valves. Product Information

Electric Actuator Installation, Operation & Maintenance Manual

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

Electric Actuator EQ Series

SERIES 1000 ELECTRIC ACTUATORS

Manual E1195 (MCP) Series 2000

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ASME 150# 2 to 6 Pipe

Electric quarter turn actuator CENTORK 480 Series

EIM CONTROLS HQ-SERIES QUARTER TURN ELECTRIC ACTUATORS

HL-Series Electric Actuator Precision control for linear valves

Agent :

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

V4(V7)-ABFW-EPN16 Actuated Wafer type butterfly valves

Motorized Butterfly Valve

Motorized Butterfly Valve Actuated Wafer type butterfly valves

Installation & Operation Manual

Motorized Butterfly Valve

Installation & Operation Manual

SAFE & SECURE ACTUATOR PRODUCT MANUAL

ROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators

Installation & Operation Manual

Installation, Operation & Maintenance Manual

ELECTRIC ACTUATOR. Unic Series ROTARY TYPE Unic Z, 05 Unic 10 Unic 20, 40 Unic 60, 100, 150, 200 OPERATION MANUAL. Koei Industry Co., Ltd.

Quarter Master Chief Series 92 Actuator

Installation & Operation Manual

E Series Electric Actuators

Electric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT

Electric Actuator Installation, Operation & Maintenance Manual

Installation & Operation Manual

Electric Modulating Actuator Installation, Operation & Maintenance Manual

Surepowr Series Sure 150

Electric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

RS ACTUATO RS ACTUATO

MC-351, 421, 431, MC-4311

EUNHA MACHINERY INDUSTRIAL CO., LTD.(EMICO)

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

SERIES 70 TUNNEL DAMPER MODEL ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Shock/Vibration Control Switches

ECON Limit Switch Box Fig

Installation & Operation Manual

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL ACTUATOR CLASSE I TYPE MA, MB

Electric Actuators Maximum in-lbs

Performance. Type NA006 NA009 NA015 NA019 NA028 NA038 NA050 NA060 NA080 NA100 NA150 NA200 NA250

VALVCON I-SERIES I6600 OPTION DN DEVICENET PROTOCOL

IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

Series Electric Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Established leaders in Actuation Technology. ROM & RBM Range 1/4 turn direct drive electric actuators. Publication E611E issue 10/02

VALVES WITH SA03 ELECTRIC ACTUATOR

Electric Actuated 3-Way Ball Valves L-Port, PVC Body, Teflon/EPDM Seals 1/2 to 2 inch Pipe

OPERATION INSTRUCTONS MODEL SG 05.1 SG Quarter-Turn Actuators

Installation & Operation Manual

VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC With Iso/Readback Board Installed (Option U )

ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC. Installation, Maintenance and Operating Instructions

Thermal Shut-Off I. OVERVIEW OF THERMAL SHUT-OFF VALVES

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ANSI/ASME 150 lb 2 to 6 inch Pipe

ANDCO Eagle Actuator Instruction Manual

Electric Actuators Maximum in-lbs

V Series 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

NSF Series Pneumatic & Hydraulic Actuators. Installation & Operation Instruction Manual NUTORK CORPORATION

Transcription:

HQ Series ¼ Turn Electric Actuator Models HQ008 to HQ300 Operation and Installation Manual HQ Series Operation and Installation Manual 1

Table of Contents: General 1.0 Actuator Mounting 2.0 Power Requirements 3.0 Duty Cycle 4.0 Manual Override 5.0 Mechanical Travel Stops 6.0 Electrical Connection 7.0 Limit Switch Settings 8.0 Torque Switch Settings 9.0 Lubrication 10.0 Mechanical Position Indicator 11.0 Maintenance 12.0 Storage 13.0 Trouble Shooting 14.0 Standard Specifications 15.0 Contact Information 16.0 HQ Series Operation and Installation Manual 2

1.0 General HQ Series electric actuators are designed to provide reliable and efficient operation of 90º quarter turn valves and dampers. Warning: Use caution when working in, with, or around valves and actuators. High pressures, forces, voltages and flammable media can be present. Warning: Failure to follow instructions for proper electrical wiring, storage, set-up and maintenance may cause serious injury, damage equipment, or void warranty. Pre-Installation Inspection Verify the actuator nameplate to ensure correct model number, torque, operating speed, voltage and enclosure type before installation or use. It is important to verify that the output torque of the actuator is appropriate for the torque requirements of the valve and that the actuator duty cycle is appropriate for the intended application. 2.0 Actuator Mounting Do not lift the actuator by the hand wheel or de-clutch lever. The actuator may be mounted in any position. HQ Series actuators are supplied with a female drive output. ISO5211 bolt patterns are provided for the actuator mounting. It is mandatory that the actuator be firmly secured to a sturdy mounting bracket or directly mounted to the valves ISO mounting pad. High tensile bolts or studs with spring locking washers must be used. The valve output stem must be in line with the actuator output drive to avoid side loading of the stem. To prevent backlash, no flexibility in the mounting bracket arrangement should be present. HQ Series Operation and Installation Manual 3

3.0 Power Requirements Consult the nameplate of the actuator (or product data sheet / catalogue) for duty cycle, voltage and current draw information. 4.0 Duty Cycle Duty cycle rated IEC34 - S2 (35%) Exceeding the actuator's rated duty cycle may cause thermal overload. 5.0 Manual Override HQ actuators are provided with a de-clutchable manual override system. To manually operate the actuator, pull the manual declutch lever towards the hand wheel until it remains in position. Turn the hand wheel until the valve reaches the required position. Turn clockwise to close and counter -clockwise to open. Please Note: The manual declutch lever has motor preference, meaning that when the motor is energized, the lever will automatically shift to auto position. 6.0 Mechanical Travel Stops Built-in mechanical stops are provided to prevent hand wheel operation beyond total valve travel. Loosen both locknuts and back out the stop bolts. Run the actuator electrically to the fully CLOSED position. Screw in the CLOSED stop bolt until it seats, then back off ½ turn and tighten locknut. Run the actuator electrically to the fully OPEN position. Screw in the OPEN stop bolt until it seats, then back off ½ turn and tighten locknut. Open Limit Stop Stop bolt Close Limit Stop Locknut Please Note: Do not set the actuator position limit switches to drive into the mechanical stops. Permanent damage will occur if the motor is allowed to repeatedly stall into the end stops. HQ Series Operation and Installation Manual 4

7.0 Electrical Connection Move valve to mid-position by hand wheel. This will allow sufficient time to stop actuator in case of improper hook-up or reversed power phases. Identify means of removing power during hookup. Be sure no erroneous remote control signals can be received causing actuator to energize. Electrically operate the valve in the open direction. If the valve closes, actuator must be stopped and the power leads reversed to correct voltage phasing or improper field wiring. Please Note: Improper power voltage phasing eliminates protection of both the position limit switch and torque switches, risking valve damage. 8.0 Limit Switch Settings Limit Switches Close Limit Switch Cam Cam Adjustment Screw Open Limit Switch Cam Operate the actuator manually to closed position. Using an allen key, loosen the cam adjustment screw in the CLOSE limit switch cam. Rotate the CLS cam CW towards the top limit switch lever until the switch 'clicks'. Tighten setscrew with allen key. Operate the actuator manually to open position. Using an allen key, loosen the cam adjustment screw in the OPEN limit switch cam. Rotate the OLS cam CCW towards the bottom limit switch lever until the switch 'clicks'. Tighten setscrew with allen key. HQ Series Operation and Installation Manual 5

9.0 Torque Switch Settings The torque switches are adjusted at factory to the protect actuator and valve against over torque. If adjustment is required, please contact us for assistance. 10.0 Lubrication The HQ series actuators are totally enclosed units with permanently lubricated gear trains (Moly EP Grease). Once installed lubrication should not be required. 11.0 Mechanical Position Indicator The HQ mechanical position indicator is held in position by belville washers and therefore can be adjusted without tools. Manually rotate actuator to fully closed position Remove actuator cover Grip the indicator firmly and carefully rotate to the correct orientation. Replace cover and check alignment. 12.0 Maintenance At least once a year a check should be made of your HQ Series Actuator. Disconnect all power to actuator. Check that all external bolting and mounting to the valve is secure. Open Electrical Enclosure. Visually inspect for any electrical or mechanical damage. Inspect for excess moisture and condensation inside the electrical enclosure. 13.0 Storage Actuators must be stored in a clean, cool and dry area. The unit shall be stored with the cover installed. If the actuator is mechanically installed but waiting for electrical connections, please ensure suitably rated cable glands or cable entry blanking plugs are fitted. HQ Series Operation and Installation Manual 6

14.0 Trouble Shooting The following instructions are offered for the most common difficulties encountered during installation and set-up. SYMPTON PROBABLE CAUSE CORRECTIVE ACTION Motor will not run. Open in control circuit Refer to appropriate wiring diagram and check for continuity. No power available to actuator. Tripped circuit breaker Reset breaker and check for correct rating. Refer to catalogue data. Hand wheel hard to turn. Valve only opens or closes partially with motor. Hand wheel does not operate valve. Incorrectly sized actuator Jammed valve Damaged or bent valve stem. Valve gland packing too tight. Limit switch incorrectly set Over torque: Incorrectly sized actuator Jammed valve Damaged or bent valve stem. Valve gland packing too tight. De-clutch lever position Damaged hand wheel mechanism Refer to catalogue data and compare valve torque requirements with actuator (torque) output. Check for obstacles in the pipeline. Check for mechanical damage. Loosen valve gland packing as per the manufacturers instructions. Check setting and reset if necessary. Check to see if torque switches have tripped. If so, refer to catalogue data and compare valve torque requirements with actuator (torque) output. Check for obstacles in the pipeline. Check for mechanical damage. Loosen valve gland packing as per the manufacturers instructions. Pull lever towards hand wheel to initiate manual operation. Check for mechanical damage, replace parts as necessary. Motor runs but does not operate valve. Stripped gearing Damaged actuator / valve linkage. Check for mechanical damage, replace parts as necessary. Check for mechanical damage, replace parts as necessary. HQ Series Operation and Installation Manual 7

15.0 Standard Specifications Enclosure Rating Weatherproof IP67 Enclosure High-grade aluminum alloy, hard anodized Power Supply 110/220VAC 1 PH 50/60Hz, 440VAC 3PH 50/60Hz Duty Cycle Motor EC 34 S2 (35%) Motor Squirrel caged induction motor Limit Switches 2 x open/close SPDT, 250VAC 10A rating Auxiliary Limit Switches 2 x open/close SPDT, 250VAC 10A rating Torque Switches open/close SPDT, 250VAC 10A rating (except HQ008) Stall Protection Built -in thermal protection Travel Angle 90-degree +/- 10% Indicator Continuous position indicator Manual Override De-clutchable manual override Mechanical Travel Stops 2 x external adjustable mechanical travel stops Space Heater 7-10W ceramic housed Conduit Entries 2 x M25 Lubrication Grease Moly EP Ambient Temperature -20 ºC to + 70 ºC External Coating Dry Polyester powder. 16.0 Contact Information For technical support, please contact the UK sales office on the numbers below: Actuated Solutions Limited Unit 5 Durban Road Business Centre Durban Road, Bognor Regis West Sussex PO22 9FE Tel: 01243 827469 Fax: 01243 829418 Email: sales@actuated-solutions.co.uk Wiring diagrams can be downloaded from our website: www.actuated-solutions.co.uk HQ Series Operation and Installation Manual 8