Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Similar documents
Power consumption In operation At rest For wire sizing

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Overview of types. Technical data. Safety notes

See «Overview of types»

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Technical data. Safety notes

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Power consumption In operation At rest For wire sizing

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Technical data. Safety notes

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption In operation At rest For wire sizing. Non-operating temperature

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Technical data sheet. Technical data. Safety notes

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

Minimum 18 in-lb Torque

Non-Spring Return SMU... series

Technical data. Safety notes

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Overview of types. Technical data

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Minimum 27 in-lb Torque

In operation At rest For wire sizing

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Minimum 27 in-lb torque

2. A E LM Form-fit versions Linear adapter ZH-LM

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

Versatile and Powerful

Versatile and Powerful

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

SM24A. Technical data. Dimensions [mm]

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

Nominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0.

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Spring-Return Damper Actuator NF24(-S)

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Characterised Control Valves with Actuators

Characterised Control Valves with Actuators

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

Belimo is the Worldwide Leader in Fire and Smoke Actuation

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Product Cross Reference

FSAF24(-S) US, FSAF120(-S) US

PN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ]

Non-Spring Return EconoDrive Floating Actuator

MF /MS Series

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Actuators for air dampers and control valves of oil burners

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V

Damper Actuators Non-Spring Return

LF Series At A Glance

SAX Electronic Valve Actuator

Actuators for air dampers and control valves of oil burners

SAV Electronic Valve Actuator

Type overview. R B2 en-gb subject to changes 1

Electric actuators for small valves

Direct Coupled Damper Actuator Model MY6050A1001

Fire and Smoke Damper Actuator product overview

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

Electromotoric actuators

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Air damper actuators

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions

Flowrite Globe. Pneumatic 4-inch Valve Actuator. Valves. Description. Applications. Features D-141.

Transcription:

echnical data sheet SH24A-SR.. Modulating linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m 2 Actuating force 45 N Nominal voltage AC/DC 24 V Control: modulating DC... V, position feedback DC 2... V Lenght of stroke or 2 mm, fixed Overview of types ype Stroke Operating range Weight SH24A-SR mm, fixed DC 2... V... mm.8 kg SH24A-SR2 2 mm, fixed DC 2... V... 2 mm.5 kg echnical data Electrical data Nominal voltage AC 24 V, 5/6 Hz DC 24 V Power supply range AC/DC 9.2... 28.8 V Power consumption In operation At rest For wire sizing 2 W @ nominal force.4 W 4 VA Connection Cable m, 3 x.75 mm 2 Functional data Actuating force 45 N @ nominal voltage Control Control signal Operating range DC... V, typical input impedance kω Position feedback (Measuring voltage U) DC 2... V, max. ma Position accuracy ±5% Stroke Direction of stroke at = V Reversible with switch resp. Running time 5 s / mm Sound power level <5 db (A) Safety Protection class III Safety extra-low voltage / UL Class 2 Supply Degree of protection IP54 in any mounting position NEMA 2, UL Enclosure ype 2 EMC CE according to 24/8/EC Certification culus according to UL 673-A and UL 673-2-4 and CAN/CSA E673-:2 Certified to IEC/EN 673- and IEC/EN 673-2-4 Mode of operation ype Rated impulse voltage Supply Control.8 kv.8 kv Control pollution degree 3 Ambient temperature range 3... +5 C Non-operating temperature 4... +8 C Ambient humidity range 95% r.h., non-condensating Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page 3 Weight. www.belimo.com 2-SH24A-SR.. en v.2 8.28 Subject to changes / 3

SH24A-SR.. / SH23ASR.. 7749-9.A A 2 3 Ø max. 8mm 3x B 2 3 Z-KS M8 Z-KS ± Z-KS M8 Z-DS Z-DS 4.5 Z-DS 5.5 www.belimo.com M2-SH24A-SR../SH23ASR.. v. 8.27 / 2

SH24A-SR.. / SH23ASR.. AC 24 V / DC 24 V ~ + U DC V DC 2 V 2 3 5 SH24A-SR.. AC 23 V N L SG..24 U 5 DC... V DC 2... V 2 2 3 5 SH23ASR.. 2 / 2 M2-SH24A-SR../SH23ASR.. v. 8.27 www.belimo.com

SH24A-SR.. Modulating linear actuators, AC/DC 24 V, 45 N Safety notes Product features! Mode of operation Manual override he actuator is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. he rotary supports and coupling pieces available as accessories must always be used if lateral forces are likely. In addition, the actuator must not be tightly bolted to the application. It must remain movable via the rotary support (refer to «Assembly notes»). If the linear actuator is exposed to severely contaminated atmosphere, appropriate precautions must be taken on the system side. Excessive deposits of dust, soot etc. can prevent the gear rack from being extended and retracted correctly. If not installed horizontally, the gear disengagement pushbutton may only be actuated when there is no pressure on the gear rod. o calculate the actuating force required for air dampers and slide valves, the specifications supplied by the damper manufacturers concerning the surface, cross section, design, installation site and the air flow conditions must be observed. If a rotary support and/or coupling piece is used, losses in the actuation force losses are to be expected. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. he actuator is controlled with a standard modulating signal of DC... V and moves to the position defined by the control signal. he measuring voltage U serves for the electrical display of the damper position... % and as slave control signal for other actuators. Manual override with push-button possible (the gear is disengaged for as long as the button is pressed or remains locked). High functional reliability he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Accessories Description Data sheet Electrical accessories Positioner SGA24, SGF24 and SGE24 2 - SG..24 Range controller SBG24 2 - SBG24 Digital position indication ZAD24 2 - ZAD24 Mechanical accessories Rotary support to compensate lateral forces Z-DS 2 - Z-SH..A.. Coupling piece Z-KS 2 - Z-SH..A.. Mechanical limiter set Z-AS 2 - Z-SH..A.. Electrical installation Wiring diagram Notes Connect via safety isolating transformer.! Other actuators can be connected in parallel. Please note the performance data! Direction of stroke ~ + 2 3 5 U DC V DC 2 V Cable colours: = black 2 = red 3 = white 5 = orange. 2 / 3 2-SH24A-SR.. en v.2 8.28 Subject to changes www.belimo.com

SH24A-SR.. Modulating linear actuators, AC/DC 24 V, 45 N Dimensions [mm] Dimensional drawings 33 75 77 25 8 ype Max. Stroke A B SH24A-SR 233.5 294.7 SH24A-SR2 2 333.5 394.7 B A Assembly notes Application without transverse forces Application with transverse forces Caution If a rotary support and/or coupling piece is! used, losses in the actuation force losses are to be expected. Stroke limitation he linear actuator is screwed directly to the housing at three points. Afterwards, the head of the gear rod is fastened to the moving part of the ventilation application (e.g. damper or slide valve). he coupling piece with the internal thread (Z-KS) is connected to the head of the gear rod. he rotary support (Z-DS) is screwed to the ventilation application. Afterwards, the linear actuator is screwed to the previously mounted rotary support with the enclosed screw. Afterwards, the coupling piece, which is mounted to the head of the gear rod, is attached to the moving part of the ventilation application (e.g. damper or slide valve). he transverse forces can be compensated for to a certain limit with the rotary support and/or coupling piece. he maximum permissible swivel angle of the rotary support and coupling piece is, laterally and upwards. If the stroke limitations are used on the gear rod, the mechanical working range can be exploited from an extension length of 2 mm. www.belimo.com 2-SH24A-SR.. en v.2 8.28 Subject to changes 3 / 3