Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Similar documents
Overview of types. Technical data. Safety notes

Power consumption In operation At rest For wire sizing

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

See «Overview of types»

Power consumption In operation At rest For wire sizing

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Technical data. Safety notes

Technical data. Safety notes

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Technical data. Safety notes

Technical data sheet. Technical data. Safety notes

Power consumption In operation At rest For wire sizing. Non-operating temperature

Power consumption In operation At rest For wire sizing

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Non-Spring Return SMU... series

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Overview of types. Technical data

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Minimum 18 in-lb Torque

2. A E LM Form-fit versions Linear adapter ZH-LM

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

PN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ]

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific

In operation At rest For wire sizing

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications

Nominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0.

Electromotoric Actuators

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

Characterised Control Valves with Actuators

Air damper actuators

Characterised Control Valves with Actuators

Electrical Actuators

Damper Actuators Non-Spring Return

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

Type overview. R B2 en-gb subject to changes 1

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Air damper actuators

Actuators for Fire Protection Dampers

Characterized Control Valves Actuators. Technical Databook Ver. 2

Electric actuators for small valves

Minimum 27 in-lb torque

Actuators for air dampers and control valves of oil burners

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

MF /MS Series

Minimum 27 in-lb Torque

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Direct Coupled Damper Actuator Model MY6050A1001

Electromotoric actuators

Butterfly Valves. Technical Databook. Belimo Asia Pacific

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Actuators for Fire and Smoke Protection Dampers

Actuators for air dampers and control valves of oil burners

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

GDB..3..1A GLB..3..1A

Direct Coupled Damper Actuator Model MY9050A1001

Product Table of overview contents and table of contents. Table of contents

Non-Spring Return EconoDrive Floating Actuator

Actuators for Fire and Smoke Protection Dampers

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Versatile and Powerful

Actuators for small valves

SAX Electronic Valve Actuator

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

DN [ ] DN [ ] Functional data Media Cold and hot water, water with glycol up to max. 50% vol.

Actuators for air dampers and control valves of oil burners

SAV Electronic Valve Actuator

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

2-position electric actuators with Ball valves VBZ ½...11/4

Actuators for Fire and Smoke Protection Dampers

M100F Incremental Motor Actuator R81F Interface Board

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

Versatile and Powerful

Electromotoric Actuators

Transcription:

echnical data sheet LH4A.. Linear actuators for operating air control dampers and slide valves in ventilation and air-conditioning systems For air control dampers up to approx. m Actuating force 5 ominal voltage AC/DC 4 V Control: Open-close or -point Lenght of stroke up to max. 6,, or mm, adjustable in steps of mm Overview of types ype Stroke Weight LH4A6 Up to max. 6 mm, adjustable in steps of mm 4 g LH4A Up to max. mm, adjustable in steps of mm 445 g LH4A Up to max. mm, adjustable in steps of mm 48 g LH4A Up to max. mm, adjustable in steps of mm 55 g echnical data Electrical data ominal voltage AC 4 V, 5/6 Hz DC 4 V Power supply range AC/DC 9.... 8.8 V Power consumption In operation At rest For wire sizing.5 W @ nominal force.5 W VA Connection Cable m, x.75 mm Functional data Actuating force 5 @ nominal voltage Stroke See «Overview of types» Direction of stroke Reversible with switch resp. Running time LH4A6 LH4A// 9 s / 6 mm 5 s / mm Sound power level <5 db (A) Safety Protection class III Safety extra-low voltage Degree of protection IP54 in any mounting position EMC CE according to 89/6/EEC Mode of operation ype (to E 67-) Rated impulse voltage.8 kv (to E 67-) Control pollution degree (to E 67-) Ambient temperature range... 5 C on-operating temperature 4... 8 C Ambient humidity range 95% r.h., non-condensating (to E 67-) Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page Weight See «Overview of types» www.belimo.com -LH4A.. en v..6 Subject to changes /

LH4A.. Linear actuators AC/DC 4 V, 5 Safety notes Product features Accessories Manual override Stroke adjustment High functional reliability! he actuator is not allowed to be used outside the specified field of application, especially not in aircraft or any other form of air transport. Assembly must be carried out by trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. he rotary supports and coupling pieces available as accessories must always be used if lateral forces are likely. In addition, the actuator must not be tightly bolted to the application. It must remain movable via the rotary support (refer to «Assembly notes»). If the linear actuator is exposed to severely contaminated atmosphere, appropriate precautions must be taken on the system side. Excessive deposits of dust, soot etc. can prevent the gear rack from being extended and retracted correctly. If not installed horizontally, the gear disengagement pushbutton may only be actuated when there is no pressure on the gear rod When calculating the required actuating force, the specifications supplied by the damper or slide valve manufacturers (cross section, design, installation site), and the air flow conditions must be observed. If a rotary support and/or coupling piece is used, losses in the actuation force are to be expected. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. Manual operation is possible with the pushbutton (the gearing latch remains disengaged as long as the pushbutton is pressed or detented). he stroke of the gear rack can be adjusted on both sides in increments of mm by means of mechanical end stops. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Electrical installation Description Data sheet Mechanical accessories Rotary support to compensate lateral forces, type Z-DS - Z-LH..A.. Coupling piece, type - Z-LH..A.. Mechanical limiter set, yp Z-AS - Z-LH..A.. otes Connection via safety isolating transformer!! Other actuators can be connected in parallel. Please note the performance data! Wiring diagrams Open-close control Connection takes priority -point control Direction of stroke / -LH4A.. en v..6 Subject to changes www.belimo.com

LH4A.. Linear actuators AC/DC 4 V, 5 Dimensions [mm] Dimensional drawings 75 4.5 65. 66 94 ype Max. Stroke A B LH4A6 6 9.5 4. LH4A.5 64. LH4A.5 64. LH4A 4.5 464. 67 B A Assembly notes Application without lateral forces Application with lateral forces Caution If a rotary support and/or coupling piece is used, losses in the actuation force are to be expected.! he linear actuator is screwed directly to the housing at three points. Afterwards, the head of the gear rod is fastened to the moving part of the ventilation application (e.g. damper or slide valve). he coupling piece with the internal thread () is connected to the head of the gear rod. he rotary support (Z-DS) is screwed to the ventilation application. Afterwards, the linear actuator is screwed to the previously mounted rotary support with the enclosed screw. Afterwards, the coupling piece, which is mounted to the head of the gear rod, is attached to the moving part of the ventilation application (e.g. damper or slide valve). he transverse forces can be compensated for to a certain limit with the rotary support and/or coupling piece. he maximum permissible swivel angle of the rotary support and coupling piece is, laterally and upwards. www.belimo.com -LH4A.. en v..6 Subject to changes /

7749-.C LH..A. / LH4A-SX.. / LH4A-MF.. / LH4A-MP.. / LHV-D-MP... A x Ø max. 8mm mm mm B ± mm Z-DS Z-DS 4.5 Z-DS 5.5 www.belimo.com M-LH..A.. v. 7.9 / 4

LH4A-SR. / LHASR.. A x Ø max. 8mm B ± Z-DS Z-DS 4.5 5.5 / 4 M-LH..A.. v. 7.9 www.belimo.com

LH..A.. / LH4A-SR. / LH4A-SX.. / LH4A-MF.. / LH4A-MP.. / LHV-D-MP.. / LHASR.. L L L AC 4 V / DC 4 V S S S...% LH4A.. LH4A-S.. AC... 4 V! L L L L S S S S S S S S S LHA.. LHA-S.....% AC 4 V / DC 4 V Y U DC V DC V Y U DC V MP 5 5 LH4A-SR.. LH4A-SX.. LH4A-MF.. LH4A-MP.. LHV-D-MP.. AC V L SG..4 Y U 5 DC... V DC... V 5 LHASR.. www.belimo.com M-LH..A.. v. 7.9 / 4

LH..A..P Z-P 6 mm 5 mm 4...6 mm ype 45-6...8 mm ype 45-4 8... mm ype 45-6 5 max 4 m 4 / 4 M-LH..A.. v. 7.9 www.belimo.com