V Linear actuator Product features Wide range of force outputs Wide selection of column adapters Large stroke range Wide selection of flanges Constant positioning times under fluctuating loads Solid metal housing Two additional force-sensitive switches possible Maintenance-free gearbox Four additional auxiliary position switches possible Operates in any position Overview V series linear actuators are utilized when precision linear adjustments are required to control elements in heating, ventilation air conditioning systems as well as in industrial applications. V series linear actuators are available with the following actuating forces: 1000 N, 2000 N, 3000 N, 4000 N 5000 N plus a maximum stroke of 85 mm. The design of the housing made of die-cast aluminium die-cast zinc in combination with a permanently lubricated gearbox made of steel with sintered-bronze bearing bushes ensure their suitability for use in a broad range of temperatures harsh operating environments. The technical construction mirrors that of series N actuators. End position limit stop is force dependent. The stard scope of supply includes a limit switch for each end position. These are designed as changeover switches can also perform supplementary functions such as end position indication or sequential control tasks. Additional auxiliary force position switches as well as potentiometers are also available. Fitting a relay makes it possible to control several actuators simultaneously via a common contact. The respective position of the valve is indicated by "Open/Closed" markings on one of the columns of the stroke unit in conjunction with the bearing surfaces of the spindle nut. A solid flange is available to mount the actuator. A driver pin is included to create the connection with the threaded spindle. Product features & Overview Agromatic Regelungstechnik GmbH Stukenbrocker Weg 38 33804 Oerlinghausen Germany Tel. +49 5202 9739-0 Fax +49 5202 9739-25 e-mail: info@agromatic.de 75
Product details Product details V 76 housing Housing made of die-cast zinc Hood made of corrosion-resistant, die-cast aluminium Coated with silicon-free paint Colour: RAL 7032 Pebble Grey Stard hoods powder coating Three cable entries M20x1.5 Protection class IP54 to DIN EN 60529 - Protection class IP65 - Custom colours - Electric anti-condensate heater (helps prevent build-up of condensate in the actuator) Motor Single-phase AC synchronous motor with permanent magnet, reversible 230 V ± 10%, 50/60 Hz ± 5% ON time 100% duty cycle on request Short start/stop times Insulation class B to VDE 0530 Synchronous motors maintain speed constant positioning times irrespective of the load Tropical insulation - Three-phase motor - DC motor - Custom voltages - Custom frequencies GEARBOX Spur gearing with straight-toothed steel gears Robust, maintenance-free Permanently lubricated gears Self-lubricating sintered bronze bearing Encapsulated version, operates in any position Spindel Self-locking "Open/Closed" markings indicate position Made of stainless steel ELECTRICAL CONNECTION Connection terminals positioned centrally close to cable entry Screw-type terminals Two free slots to retrofit additional force/position switches Additional PCB terminals ensure retrofitting systems extensions is fully unproblematic Infinitely adjustable control cams Open/close signals Limit switch for each end position - Path dependent limit switch-off - Additional potential-free switching contacts - Electronic position controller ESR-N (integrated in actuator or external) - Potentiometer 200 Ω 10 kω AMBIENT TEMPERATURE -15 C to +60 C 0 C to +60 C when utilizing electronic position controller ESR-N - Up to +80 C, duty cycle S3-50% - Down to -40 C REGULATING DISTANCE LIMITED BY FORCE- SENSITIVE SNAP-ACTION POSITION OFF SWITCH CO switches with silver-plated contacts Switch connections routed to terminal strip Max. switching capacity: 6 A, 250 V AC - Switches with gold-plated contacts - Switches with positive-break contacts - Switches designed for higher temperatures POSITION SENSOR FOR EXTERNAL POSITION INDICATION (OPTIONAL) With potentiometer - Choice of wire-wound or conductive plastic potentiometer - Multiturn potentiometer up to 10 turns - Up to three potentiometers possible - It is possible to adapt the electrical angle of rotation of the potentiometer to the desired regulating distance utilizing a gearbox. With 4 20 ma transmitter - Utilizing a gearbox it is possible to adapt the electrical angle of rotation of the transmitter to the desired angle of rotation.
MANUAL OPERATION (OPTIONAL) Using the hwheel it is possible to manually adjust the position of the output shaft valves. Disengaging the gearbox motor reduces the amount of force required. Position switch-off settings are retained during manual operation. Hwheel remains motionless during electrical operation. Options Other voltage/frequency Other ambient temperature range Higher protection class Hwheel Gearbox disengages manually Additional auxiliary position switches Custom control cams Electronic position controller ESR-N Position sensor Anti-condensate heater Relay - Pulse relay - Relay to switch several actuators in parallel Potentiometer Components to UL stard Encapsulated stroke unit Position switch-off Set collars serve as external travel stops (recommended for force-sensitive switch off) Installation Easy to mount thanks to modified column adapters/flanges Easily coupled to the spindle nut by means of a wide variety of threaded, through hole split driving collars Order details Device type Positioning force Stroke Positioning time Column clearance/flange fitting dimensions Operating voltage /frequency Desired options When ordering a potentiometer: - Resistance value - Desired linear regulating distance - Stard: regulating distance set to maximum, other regulating distances possible on request When ordering position switches: - Stard: regulating distance set to maximum, other regulating distances possible on request Or order number Desired valve, where applicable Product details V 77
Technical data ACTUATORS V SERIES, 230 V, 50/60 Hz Type Positioning time Positioning force Power consumption (max.) Hood Weight Order No. V 1 0.1(0.12) mm/s 1000 N 7 VA 5.5 kg 80110 V 1 1000 N 7 VA 5.6 kg 80111 V V 1 0.6(0.7) mm/s 1000 N 18 VA 5.7 kg 80112 V 2 2000 N 18 VA 80 V 2 0.6(0.7) mm/s 2000 N 31 VA 80121 V 3 3000 N 18 VA 5.7 kg 80130 V 3 0.8(1.0) mm/s 3000 N 31 VA 80131 V 4 4000 N 31 VA 80140 V 4 0.8(1.0) mm/s 4000 N 32 VA 28 mm+ 6.7 kg 80141 V 5 0.4(0.5) mm/s 5000 N 32 VA 28 mm+ 6.8 kg 80150 V 5 0.8(1.0) mm/s 5000 N 69 VA 28 mm+148 mm 7.6 kg 80151 Technical data SCHEMATIC DIAGRAM STANDARD AC 78
Dimensions Stroke = 138 - starting height I Stroke = 149 - starting height II Type X Dimensions V Starting height I > 53 Starting height I < 133 Starting height II > 64 Starting height II < 144 V 1 (0.3 mm/s) V 2 (0.3 mm/s) MY M6 V 3 (0.3 mm/s) M10 With optional spindle adjusting nut With optional spindle adjusting nut V 4 (0.3 mm/s) M12 Stroke = 128 - starting height I Starting height I > 53 Starting height I < 123 Stroke = 139 - starting height II Starting height II > 64 Starting height II < 134 V 4 (0.8 mm/s) V 5 (0.4 mm/s) V 5 (0.8 mm/s) 148 148 176 ød 7 9 H 3.5 6.0 M12x1 M14x1.5 M16x1.5 79