Linear Position Bracket Mounted for Linear Actuators Resin SERIES HS2 HS3 HS Features Process valve body is serviceable without removing indicator box Built-in understroke compensation Simple to install and adjust Designed for caustic washdown One construction accommodates valve strokes up to 2 inches visible from 360 onstruction Area lassifications Switch Type over Switch Trigger Inner Frame HS 2 HS 3 HS Hazardous Location* IP66 Outdoor Hazardous Location* Mechanical / Reed 1 Mechanical SPDT gold plated switch is also available for intrinsically safe (IS) applications. * See Specifications hart. Makrolon 2607 is a registered trademark of Bayer Inc. IP66 /Outdoor Non-Hazardous Location Valox 36 (Resilient PBT) Polycarbonate (Makrolon Grade 2607 ) UV Stabilized ABS Zytel Nylon ) % # Ambient Temperatures Reed Switches: - F to 150 F (-20 to 65 ) ASi, DeviceNet Bus ard: - F to 10 F (-20 to 60 ) Profibus PA: 32 F to 10 F (0 to 60 ) (ontact ASO for extended temperature range applications.) Electrical Mechanical Switches Gold ontacts Maximum 100mA@125/250VA Minimum ma@5vd Silver ontacts Maximum 15A@125/250VA Minimum 125mA@125/250VA Reed Switches Tungsten: 120VA@3A or 2VD@2A Maximum power allowable is 100 Watts or 100VA Minimum power required to ensure proper operation is 3W or 3VA Rhodium: 2VD@1A Maximum power allowable is 25 Watts Minimum current required to ensure proper operation is 10mA@3VD Rhodium (IS): 2mA to 1A@2VD (suitable for IS applications) IS - lass I,II,III, Div. 1, Groups A,B,,D,E,F, and G lass I, Zone 0, AEx ia II T6 lass I, Zone 1, AEx ib II T6 ATEX category 1G, 2G Intrinsic Safety Only II 1G EEx i a II T6 KEMA 0 ATEX 1025X Ambient Temperature: -18 to 170 F (-28 to 77 ) NOTE: ASO requires 12VD valves for DeviceNet Network ards and 2VD for AS-interface Network ards. Approvals FM approved for: Hazardous (lassified) locations ; lass 3600, 3610 & 3611 (HS 2 & 3). Unclassified Locations (HS ). SA ertified to Standard 22.2 No. 12-M Process ontrol Equipment ; Hazardous Locations, lass 2258-02, 0, 82 & 8 (HS 2 & 3), and General Requirements, lass 2252-01(HS ), File 013976-0-000. E ertified. Optional Features Attached low power pilot valve or with integrated valve. AS-interface, Profibus-PA, DeviceNet communication cards with 2 switches to indicate stem position. Up to 2 conduit entries select from: 1/2" or 20mm. Plug, cable gland, and network connectors. See list price schedule for available mounting brackets and adapters. 11
SERIES HS2 HS3 HS Specifications Series Hazardous lassified Location Shaft Intrinsically Safe: lass1,2,3/div.1/a,b,,d/t6 lass1/zone 0/AEx ia II/T6 lass1/zone 1/AEx ib II/T6 Ambient Temp. = 77 /170 F lass2/div.1/a,b,,d,e,f,g HS2 Series Non-Incendive: with Reed Switcheslass1/Div.2/A,B,,D/T6 lass2/div.2/f,g/t6 Except Dust Ambient Temp. = 65 /150 F Special Protection: Only Non-Incendive: with Bus ard lass1/div.2/a,b,,d/t6 lass2/div.2/f,g/t6 Ambient Temp. = 60 /10 F Special Protection: Only D=10-2 onduit / 1 1=(2) 1/2 FNPT 9=(1) 1/2 FNPT + (1) M20 x 1.5 Y=Yel/Black Letter Switches # of Switches Network/Bus 1 M20 x 1.5 with PIN required. * For correct operation, ASO mouning bracket must be used. See ASO VMS list price schedule for mounting kits. Ordering Example: HS2D1BYT2NGA N=None H=Mech SPDT Gold (IS) G=Reed SPDT Rhodium (IS) T=Reed SPDT Tungsten 3A R=Reed SPDT Rhodium 1A W=Network ard AJ=ASI 2x1, v2.1, Std Address AL=ASI 2x1, v2.1, Ext Address D=DNET2x1 DE=DNET 2x1 Diagnostics PA=Profibus-PA, Non IS onduit onduit B=M12 Pin =Mini (7/8) Pin HS2 D 1 Y T 2 NG A Series Hazardous lassified Location Shaft HS3 Series IP-66 Outdoor Series Hazardous lassified Location Shaft HS Series IP-66 / Outdoor Intrinsically Safe: lass1,2,3/div.1/a,b,,d/t6 lass1/zone 0/AEx ia II/T6 lass1/zone 1/AEx ib II/T6 Ambient Temp. = 77 /170 F lass2/div.1/a,b,,d,e,f,g Non-Hazardous D=10-2 D=10-2 onduit / 1 1=(2) 1/2 FNPT 9=(1) 1/2 FNPT + (1) M20 x 1.5 onduit / 1 1=(2) 1/2 FNPT 9=(1) 1/2 FNPT + (1) M20 x 1.5 Y=Yel/Black Y=Yel/Black Letter Switches # of Switches Network/Bus N=None H=Mech SPDT Gold (IS) G=Reed SPDT Rhodium (IS) T=Reed SPDT Tungsten 3A R=Reed SPDT Rhodium 1A W=Network ard Letter Switches # of Switches Network/Bus N=None onduit B=M12 Pin A=Mech SPDT U=One Upper (open) Silver 15A L=One Lower (closed) H=Mech SPDT =Mini (7/8) Pin Gold (IS) HS D 1 Y A 2 NG A AJ=ASI 2x1, v2.1, Std Address AL=ASI 2x1, v2.1, Ext Address D=DNET2x1 DE=DNET 2x1 Diagnostics PA=Profibus-PA, Non IS onduit onduit B=M12 Pin =Mini (7/8) Pin HS3 D 1 Y T 2 NG A Dimensions: Inches (mm) 3.67 [93] TOP VIEW 1.89 [8] 3.73 [ 95].88 [12] 1/2 NPT OR M20 x 1.5 2 PLAES SIDE VIEW 12 3.78 [96] 1.08 [27] 1.08 [27]
Linear Position Bracket Mounted with Integrated Valve for Linear Actuators Resin/Aluminum SERIES HS INTEGRATED with Integrated Valve Features Simpler to order Available in 0.3 v only Solenoid valve is environmentally protected inside the housing Reliable poppet construction Built-in relief valve prevents pressurizing of internal indicator housing External manual override % # PENDING PENDING Solenoid Valve Specifications 1/" NPT threaded ports v flow factor of 0.3 Medium - AIR or INERT GASES only Pressure min. & max. - 30 to 120 psi Recommended filtration - 50 microns (50um) oil wattage of 0.5 Watt in 2VD or 1.0 Watt in 12VD, 120/60 or 20/60 Optional Features AS-interface, DeviceNet communication cards with 2 switches to indicate stem position. 2 conduit entries select from: 1/2" or 20mm. See list price schedule for available mounting brackets and adapters. Integrated Valve onstruction Hardware Popet Sealing Material Anodized Aluminum Stainless Steel Stainless Steel NBR onstruction HS 2 HS Area lassifications Switch Type over Switch Trigger Inner Frame Hazardous Location* Mechanical / Reed IP66 /Outdoor Non-Hazardous Location Valox 36 (Resilient PBT) Polycarbonate (Makrolon Grade 2607 ) UV Stabilized ABS Zytel Nylon 13
SERIES HS INTEGRATED Specifications Series HS2 Series Only HS Series IP-66 /Outdoor Hazardous lassifiedlocation Non-Incendive lass1/div. 2/A,B,,D/T lass1/div. 2/F,G/T Ambient Temp. = 60 /10 F Special Protection: Only Intrinsically Safe: lass1,2,3/div.1/a,b,,d/t6 lass1/zone 0/AEx ia II/T6 lass1/zone 1/AEx ib II/T6 Ambient Temp. = 60 /10 F lass2/div.1/a,b,,d,e,f,g Non-Hazardous Ordering Example with valve: HS2DYW2DE15F Description: (HS2 Series with #10-2 Shaft thread, (1) M20x1.5 threaded conduit, yellow/black indicator, (2) hall effect sensors, DNet Bus ard with diagnostics, Mini (7/8") pin connector, 3/2 N 1/ NPT valve, screw-in manual operator, 12VD) * For correct operation, ASO mouning bracket must be used. See ASO VMS list price schedule for mounting kits. Integrated Solenoid Valve Ordering Dimensions: Inches (mm) Shaft D=#10-2 D=#10-2 D=#10-2 onduit / 1 onstruction Port #1 Port #2 Port #3 3/2 N Pressure ylinder Exhaust A=(1) 1/2 FNPT =(1) M20 x 1.5 Y=Yel/Black Letter Switches # of Switches Network/Bus N=No Switch T=Reed SPDT Tungsten 3A R=Reed SPDT Rhodium 1A W=Network ard A=(1) 1/2 FNPT =(1) M20 x 1.5 Y=Yel/Black G=Reed SPDT Rhodium (IS) H=Mech SPDT Gold (IS) A=(1) 1/2 FNPT =(1) M20 x 1.5 Y=Yel/Black N=No Switch A=Mech SPDT Silver 15A H=Mech SPDT Gold (IS) T=Reed SPDT Tungsten 3A R=Reed SPDT Rhodium 1A W=Network ard U=One Open/Upper L=One losed/lower U=One Open/Upper L=One losed/lower U=One Open/Upper L=One losed/lower AJ=ASI 2x1, v2.1, Std Address AL=ASI 2x1, v2.1, Ext Address D=DNET2x1 DE=DNET 2x2 Diagnostics AJ=ASI 2x1, v2.1, Std Address AL=ASI 2x1, v2.1, Ext Address D=DNET2x1 DE=DNET 2x2 Diagnostics onduit onduit B=M12 pin connector for Bus =Mini (7/8") pin connector for bus onduit onduit onduit B=M12 pin connector for Bus =Mini (7/8") pin connector for bus HS2 D Y W 2 DE Valve Manual Operator Voltages ode Operation Pipe ode Type To Operate ode Voltage A 120/60 1 3/2 N 1/ NPT 5 Screw In Screw Driver 1 5 F B 20/60 D E F 2/D IS 12/D Ø3.57 [93] 1.89 [8] 3.73 [95].88 [12].09 [10.].39 [10].610 [15.5] 5.007 [127.18] 1 1/2 NPT M20 x 1.5 THREAD 3.07 [77.].610 [15.5].276 [7].09 [10.]
Aluminum Linear Position s for Linear Actuators SERIES HS1 Features Explosion proof, Div. 1 rated aluminum housing for hazardous locations. Simple to install and adjust. Understroke compensating switch triggers. Multiple position mountable (12 possible orientations). No seal fittings required with Viper switches in lass I, Div. 1, Group A,B,,D areas. One construction accomodates strokes up to 2 inches. % # onstruction Area lassifications oating Switch Triggers Inner Frame Zytel - DuPont o. Trademark * See Specification hart. /Outdoor Hazardous Location* Low opper Aluminum Black Hard Anodized ABS Zytel Nylon Ambient Temperatures: -20 to 170 F (T6) - to 10 F with Bus ard Electrical Mechanical Switches - 15amp silver contacts SPDT - 100mA @ 30VD gold plated contacts SPDT (IS) Viper Switches - Tungsten: 3A/120VA, 2A/2VD - Rhodium: 1A/2VD - Rhodium (IS): 2mA to 1A@2VD Viper - ASO Valve, Inc. Trademark Optional Features Low power pilot valve mounted to enclosure Network Junction Box for hazardous locations, communication cards with 2 switches to indcate stem position 2 or 3 conduit entries in 3/ FNPT Approvals FM approved for Hazardous (lassified) locations ; lass 3600, 3610, 3611, & 3615. SA ertified to Standard 22.2 No. 12-M Process ontrol Equipment ; Hazardous Locations, lass 2258-02, 0, 82 & 8. 3.2 R1
SERIES HS1 Specifications Series Hazardous lassified Location Shaft onduit HS1 Series /Outdoor Explosionproof: with Switches lass1/div.1/a,b,,d/t6 Dust Ignition Proof: lass2,3/div.1/e,f,g/t6 Ambient Temp. = 77 /170 F Explosionproof: with Bus ard lass1/div.1/a,b,,d/t6 Dust Ignition Proof: lass2,3/div.1/e,f,g/t6 Ambient Temp = 60 /10 F F=ITT(<1") G=Saunders(<1") H=ITT(1-1/" to 2") J=Saunders(1-1/2" to 3") K=ITT Series 7 (3" & ") Q=ITT Series 33 (3" & ") L=Gemu D6 (1/2" to 1") M=Gemu D6 (1-1/" to 1-1/2") 2=(2) 3/ FNPT =(3) 3/ FNPT N=None Letter Switches # of Switches Network/Bus A A=Mech SPDT Silver 15A H= Mech SPDT Gold (IS) G=Viper SPDT Rhodium (IS) T=Viper SPDT Tungsten 3A R=Viper SPDT Rhodium 1A U=One Upper L=One Lower W=Network/Bus ard AJ=ASI 2x1, v2.1, Std. Address AL=ASI 2x1, v2.1, Ext. Address D=DNET2x1 DE=DNET 2x1 Diagnostics HS1 F 2 N A A 2 NG A Ordering Number Example: HS1F2NAA2NGA Order appropriate mounting kits as noted below. Letter A Mounting Kits Shaft ode Actuator Pipe Size Stroke Plate Mounting Kit Numbers F ITT < 1" Up to.50" FLAT 281621-001 G Saunders < 1" Up to.50" FLAT 281621-001 H ITT 1-1/" to 2".50" - 1.685" EXT 281621-002 J Saunders 1-1/2" to 3".65" - 1.685" EXT 281621-002 K ITT Series 7 3" & " 1.62" - 1.685" FLAT 281621-001 Q ITT Series 33 3" & " 1.62" EXT 281621-002 L Gemu D6 1/2" to 1".320" to.533" FLAT 281621-003 M Gemu D6 1-1/" & 1-1/2"." to.75" FLAT 281621-003 Dimensions Inches.2 5 5.9 3/.NPT 3/.NPT 2.13.2 5 1.55 Mounting Plates (Included in mounting kit) FLAT Add 1/2" to overall height EXT Add 2-1/" to overall height 3.3 R1