Linear Position Indicator Bracket Mounted for Linear Actuators Resin Body

Similar documents
ALS SERIES VALVE MONITOR ATEX. Exd

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Quartz. Save Space with Low Profile Design

Quartz Explosionproof valve monitoring

97105 Inline. Ordering information. Technical data. Accessories See page 5

LIMIT SWITCH Axiom - AX

AST46HA Factory Sealed Gauge / ASIC

LIMIT SWITCH Axiom - AX

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

Non-incendive, explosionproof - NEC

Quartz Explosionproof valve monitoring

SANITARY VALVE POSITION AND CONTROL MONITORS NON-INCENDIVE, EXPLOSIONPROOF - NEC

LIMIT SWITCH Axiom - AX

Quartz Explosionproof valve monitoring

JM - Junction Enclosure Modules for Communication Networks

Electrical position indicators and combi switchboxes for linear and quarter turn valves

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Poppet Valves Series

Valve Position Monitors

2/2. Air or Water Pilot Operated Angle Body Multi-Purpose Valves. Bronze or 316L Stainless Steel Bodies 3/8" to 2 1/2" NPT.

HERION SERIES Indirect solenoid actuated soft seal

Features. Flexibility

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

General purpose / hazardous area

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

V200 Series Positioners

LIMIT SWITCHES & POSITION INDICATION

Our policy is one of continued research and development. We therefore reserve the right

Valve Position Monitors

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Point level measurement Capacitance switches

QUANTUM. Quantum Low Power Control Monitor LOW POWER CONTROL MONITOR. " Design Features

97100 NAMUR. Technical data

Electrical position indicators and combi switchboxes for linear and quarter turn valves

Pneumatic Actuator Accessories. Discrete, NEMA 4, Four-Way Air/Air Suffix A2 (For PAD3 & PKD2 actuators)

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

V200 Series Positioners

Level Measurement Point level measurement - RF Capacitance switches

Flow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

Prism PI Intelligent features offer advanced performance

VALVE ACCESSORIES & CONTROLS V200 POSITIONER A POSITIONER THAT OFFERS IT ALL IN ONE COMPACT, SIMPLE, HOUSING

VALVE MONITOR Suitable for use on rotary and linear applications Certified for use in all hazardous aeras

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

SKINNER Intrinsically Safe Series Four-Way

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED

V200 Series Positioners

valve communication and control

LIMIT SWITCH Prism - PI

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Modular electrical and pneumatic automation system

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

COMPLETE LISTING OF OPTIONS. Toggles, Lights

3 Way/2 Position Valves

Overview. Specifications. Applications

SATRON VDt Differential Pressure Transmitter

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Electro-pneumatic control valves

Eclipse Compact and modular with solid state reliability

2/2-way Angle-Seat Valve for high-quality cryogenic applications and steam

Contents. FieldQ. FieldQ. Product data sheet Rev. 0 October FieldQ Valve Actuator 2. FieldQ Actuator Torque 4

CONTROLS INC. Position Indicators. Valve Positioners

ITS Series Position Monitoring Switch

BETA SWITCHES FOR HAZARDOUS AREA

Our policy is one of continued research and development. We therefore reserve the right

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Control & Power, Inc

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Valve Control Solutions

Flameproof Level Sensor (Flameproof F/S FP)

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

A comprehensive range of pneumatic actuators, providing compact, reliable and economical powered operation for all types of quarter-turn valves.

Masoneilan Series

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

4 N E X T G E N E R A T I O N

A robust, pilot operated solenoid valve for direct mounting to pneumatic actuators Figure 79E/79U and PremiAir.

Redundant Control System

D Series Ex d Stainless Steel

Level Measurement Point level measurement - RF Capacitance switches

The H Series Leak-Proof, High-Pressure Valves Versa Products Company has been supplying high quality pneumatic and hydraulic directional control valve

8290 Series. Angle Body Piston Valves. Introducing the all NEW 8290 Assembly Configurator

POSITIONERS and Controls for Complete Valve Automation

Constructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

L I N K I N G T H E P R O C E S S W I T H T H E C O N T R O L R O O M CCOE

Material pressure (bar) (Cv (US) kv x 1,2 Seat

2-Way/2 Position Valves

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

Level limit switch Series RF 3000 Selection list

Operating pressure (bar) kv factor (m 3 /h) *3)

Transcription:

Linear Position Bracket Mounted for Linear Actuators Resin SERIES HS2 HS3 HS Features Process valve body is serviceable without removing indicator box Built-in understroke compensation Simple to install and adjust Designed for caustic washdown One construction accommodates valve strokes up to 2 inches visible from 360 onstruction Area lassifications Switch Type over Switch Trigger Inner Frame HS 2 HS 3 HS Hazardous Location* IP66 Outdoor Hazardous Location* Mechanical / Reed 1 Mechanical SPDT gold plated switch is also available for intrinsically safe (IS) applications. * See Specifications hart. Makrolon 2607 is a registered trademark of Bayer Inc. IP66 /Outdoor Non-Hazardous Location Valox 36 (Resilient PBT) Polycarbonate (Makrolon Grade 2607 ) UV Stabilized ABS Zytel Nylon ) % # Ambient Temperatures Reed Switches: - F to 150 F (-20 to 65 ) ASi, DeviceNet Bus ard: - F to 10 F (-20 to 60 ) Profibus PA: 32 F to 10 F (0 to 60 ) (ontact ASO for extended temperature range applications.) Electrical Mechanical Switches Gold ontacts Maximum 100mA@125/250VA Minimum ma@5vd Silver ontacts Maximum 15A@125/250VA Minimum 125mA@125/250VA Reed Switches Tungsten: 120VA@3A or 2VD@2A Maximum power allowable is 100 Watts or 100VA Minimum power required to ensure proper operation is 3W or 3VA Rhodium: 2VD@1A Maximum power allowable is 25 Watts Minimum current required to ensure proper operation is 10mA@3VD Rhodium (IS): 2mA to 1A@2VD (suitable for IS applications) IS - lass I,II,III, Div. 1, Groups A,B,,D,E,F, and G lass I, Zone 0, AEx ia II T6 lass I, Zone 1, AEx ib II T6 ATEX category 1G, 2G Intrinsic Safety Only II 1G EEx i a II T6 KEMA 0 ATEX 1025X Ambient Temperature: -18 to 170 F (-28 to 77 ) NOTE: ASO requires 12VD valves for DeviceNet Network ards and 2VD for AS-interface Network ards. Approvals FM approved for: Hazardous (lassified) locations ; lass 3600, 3610 & 3611 (HS 2 & 3). Unclassified Locations (HS ). SA ertified to Standard 22.2 No. 12-M Process ontrol Equipment ; Hazardous Locations, lass 2258-02, 0, 82 & 8 (HS 2 & 3), and General Requirements, lass 2252-01(HS ), File 013976-0-000. E ertified. Optional Features Attached low power pilot valve or with integrated valve. AS-interface, Profibus-PA, DeviceNet communication cards with 2 switches to indicate stem position. Up to 2 conduit entries select from: 1/2" or 20mm. Plug, cable gland, and network connectors. See list price schedule for available mounting brackets and adapters. 11

SERIES HS2 HS3 HS Specifications Series Hazardous lassified Location Shaft Intrinsically Safe: lass1,2,3/div.1/a,b,,d/t6 lass1/zone 0/AEx ia II/T6 lass1/zone 1/AEx ib II/T6 Ambient Temp. = 77 /170 F lass2/div.1/a,b,,d,e,f,g HS2 Series Non-Incendive: with Reed Switcheslass1/Div.2/A,B,,D/T6 lass2/div.2/f,g/t6 Except Dust Ambient Temp. = 65 /150 F Special Protection: Only Non-Incendive: with Bus ard lass1/div.2/a,b,,d/t6 lass2/div.2/f,g/t6 Ambient Temp. = 60 /10 F Special Protection: Only D=10-2 onduit / 1 1=(2) 1/2 FNPT 9=(1) 1/2 FNPT + (1) M20 x 1.5 Y=Yel/Black Letter Switches # of Switches Network/Bus 1 M20 x 1.5 with PIN required. * For correct operation, ASO mouning bracket must be used. See ASO VMS list price schedule for mounting kits. Ordering Example: HS2D1BYT2NGA N=None H=Mech SPDT Gold (IS) G=Reed SPDT Rhodium (IS) T=Reed SPDT Tungsten 3A R=Reed SPDT Rhodium 1A W=Network ard AJ=ASI 2x1, v2.1, Std Address AL=ASI 2x1, v2.1, Ext Address D=DNET2x1 DE=DNET 2x1 Diagnostics PA=Profibus-PA, Non IS onduit onduit B=M12 Pin =Mini (7/8) Pin HS2 D 1 Y T 2 NG A Series Hazardous lassified Location Shaft HS3 Series IP-66 Outdoor Series Hazardous lassified Location Shaft HS Series IP-66 / Outdoor Intrinsically Safe: lass1,2,3/div.1/a,b,,d/t6 lass1/zone 0/AEx ia II/T6 lass1/zone 1/AEx ib II/T6 Ambient Temp. = 77 /170 F lass2/div.1/a,b,,d,e,f,g Non-Hazardous D=10-2 D=10-2 onduit / 1 1=(2) 1/2 FNPT 9=(1) 1/2 FNPT + (1) M20 x 1.5 onduit / 1 1=(2) 1/2 FNPT 9=(1) 1/2 FNPT + (1) M20 x 1.5 Y=Yel/Black Y=Yel/Black Letter Switches # of Switches Network/Bus N=None H=Mech SPDT Gold (IS) G=Reed SPDT Rhodium (IS) T=Reed SPDT Tungsten 3A R=Reed SPDT Rhodium 1A W=Network ard Letter Switches # of Switches Network/Bus N=None onduit B=M12 Pin A=Mech SPDT U=One Upper (open) Silver 15A L=One Lower (closed) H=Mech SPDT =Mini (7/8) Pin Gold (IS) HS D 1 Y A 2 NG A AJ=ASI 2x1, v2.1, Std Address AL=ASI 2x1, v2.1, Ext Address D=DNET2x1 DE=DNET 2x1 Diagnostics PA=Profibus-PA, Non IS onduit onduit B=M12 Pin =Mini (7/8) Pin HS3 D 1 Y T 2 NG A Dimensions: Inches (mm) 3.67 [93] TOP VIEW 1.89 [8] 3.73 [ 95].88 [12] 1/2 NPT OR M20 x 1.5 2 PLAES SIDE VIEW 12 3.78 [96] 1.08 [27] 1.08 [27]

Linear Position Bracket Mounted with Integrated Valve for Linear Actuators Resin/Aluminum SERIES HS INTEGRATED with Integrated Valve Features Simpler to order Available in 0.3 v only Solenoid valve is environmentally protected inside the housing Reliable poppet construction Built-in relief valve prevents pressurizing of internal indicator housing External manual override % # PENDING PENDING Solenoid Valve Specifications 1/" NPT threaded ports v flow factor of 0.3 Medium - AIR or INERT GASES only Pressure min. & max. - 30 to 120 psi Recommended filtration - 50 microns (50um) oil wattage of 0.5 Watt in 2VD or 1.0 Watt in 12VD, 120/60 or 20/60 Optional Features AS-interface, DeviceNet communication cards with 2 switches to indicate stem position. 2 conduit entries select from: 1/2" or 20mm. See list price schedule for available mounting brackets and adapters. Integrated Valve onstruction Hardware Popet Sealing Material Anodized Aluminum Stainless Steel Stainless Steel NBR onstruction HS 2 HS Area lassifications Switch Type over Switch Trigger Inner Frame Hazardous Location* Mechanical / Reed IP66 /Outdoor Non-Hazardous Location Valox 36 (Resilient PBT) Polycarbonate (Makrolon Grade 2607 ) UV Stabilized ABS Zytel Nylon 13

SERIES HS INTEGRATED Specifications Series HS2 Series Only HS Series IP-66 /Outdoor Hazardous lassifiedlocation Non-Incendive lass1/div. 2/A,B,,D/T lass1/div. 2/F,G/T Ambient Temp. = 60 /10 F Special Protection: Only Intrinsically Safe: lass1,2,3/div.1/a,b,,d/t6 lass1/zone 0/AEx ia II/T6 lass1/zone 1/AEx ib II/T6 Ambient Temp. = 60 /10 F lass2/div.1/a,b,,d,e,f,g Non-Hazardous Ordering Example with valve: HS2DYW2DE15F Description: (HS2 Series with #10-2 Shaft thread, (1) M20x1.5 threaded conduit, yellow/black indicator, (2) hall effect sensors, DNet Bus ard with diagnostics, Mini (7/8") pin connector, 3/2 N 1/ NPT valve, screw-in manual operator, 12VD) * For correct operation, ASO mouning bracket must be used. See ASO VMS list price schedule for mounting kits. Integrated Solenoid Valve Ordering Dimensions: Inches (mm) Shaft D=#10-2 D=#10-2 D=#10-2 onduit / 1 onstruction Port #1 Port #2 Port #3 3/2 N Pressure ylinder Exhaust A=(1) 1/2 FNPT =(1) M20 x 1.5 Y=Yel/Black Letter Switches # of Switches Network/Bus N=No Switch T=Reed SPDT Tungsten 3A R=Reed SPDT Rhodium 1A W=Network ard A=(1) 1/2 FNPT =(1) M20 x 1.5 Y=Yel/Black G=Reed SPDT Rhodium (IS) H=Mech SPDT Gold (IS) A=(1) 1/2 FNPT =(1) M20 x 1.5 Y=Yel/Black N=No Switch A=Mech SPDT Silver 15A H=Mech SPDT Gold (IS) T=Reed SPDT Tungsten 3A R=Reed SPDT Rhodium 1A W=Network ard U=One Open/Upper L=One losed/lower U=One Open/Upper L=One losed/lower U=One Open/Upper L=One losed/lower AJ=ASI 2x1, v2.1, Std Address AL=ASI 2x1, v2.1, Ext Address D=DNET2x1 DE=DNET 2x2 Diagnostics AJ=ASI 2x1, v2.1, Std Address AL=ASI 2x1, v2.1, Ext Address D=DNET2x1 DE=DNET 2x2 Diagnostics onduit onduit B=M12 pin connector for Bus =Mini (7/8") pin connector for bus onduit onduit onduit B=M12 pin connector for Bus =Mini (7/8") pin connector for bus HS2 D Y W 2 DE Valve Manual Operator Voltages ode Operation Pipe ode Type To Operate ode Voltage A 120/60 1 3/2 N 1/ NPT 5 Screw In Screw Driver 1 5 F B 20/60 D E F 2/D IS 12/D Ø3.57 [93] 1.89 [8] 3.73 [95].88 [12].09 [10.].39 [10].610 [15.5] 5.007 [127.18] 1 1/2 NPT M20 x 1.5 THREAD 3.07 [77.].610 [15.5].276 [7].09 [10.]

Aluminum Linear Position s for Linear Actuators SERIES HS1 Features Explosion proof, Div. 1 rated aluminum housing for hazardous locations. Simple to install and adjust. Understroke compensating switch triggers. Multiple position mountable (12 possible orientations). No seal fittings required with Viper switches in lass I, Div. 1, Group A,B,,D areas. One construction accomodates strokes up to 2 inches. % # onstruction Area lassifications oating Switch Triggers Inner Frame Zytel - DuPont o. Trademark * See Specification hart. /Outdoor Hazardous Location* Low opper Aluminum Black Hard Anodized ABS Zytel Nylon Ambient Temperatures: -20 to 170 F (T6) - to 10 F with Bus ard Electrical Mechanical Switches - 15amp silver contacts SPDT - 100mA @ 30VD gold plated contacts SPDT (IS) Viper Switches - Tungsten: 3A/120VA, 2A/2VD - Rhodium: 1A/2VD - Rhodium (IS): 2mA to 1A@2VD Viper - ASO Valve, Inc. Trademark Optional Features Low power pilot valve mounted to enclosure Network Junction Box for hazardous locations, communication cards with 2 switches to indcate stem position 2 or 3 conduit entries in 3/ FNPT Approvals FM approved for Hazardous (lassified) locations ; lass 3600, 3610, 3611, & 3615. SA ertified to Standard 22.2 No. 12-M Process ontrol Equipment ; Hazardous Locations, lass 2258-02, 0, 82 & 8. 3.2 R1

SERIES HS1 Specifications Series Hazardous lassified Location Shaft onduit HS1 Series /Outdoor Explosionproof: with Switches lass1/div.1/a,b,,d/t6 Dust Ignition Proof: lass2,3/div.1/e,f,g/t6 Ambient Temp. = 77 /170 F Explosionproof: with Bus ard lass1/div.1/a,b,,d/t6 Dust Ignition Proof: lass2,3/div.1/e,f,g/t6 Ambient Temp = 60 /10 F F=ITT(<1") G=Saunders(<1") H=ITT(1-1/" to 2") J=Saunders(1-1/2" to 3") K=ITT Series 7 (3" & ") Q=ITT Series 33 (3" & ") L=Gemu D6 (1/2" to 1") M=Gemu D6 (1-1/" to 1-1/2") 2=(2) 3/ FNPT =(3) 3/ FNPT N=None Letter Switches # of Switches Network/Bus A A=Mech SPDT Silver 15A H= Mech SPDT Gold (IS) G=Viper SPDT Rhodium (IS) T=Viper SPDT Tungsten 3A R=Viper SPDT Rhodium 1A U=One Upper L=One Lower W=Network/Bus ard AJ=ASI 2x1, v2.1, Std. Address AL=ASI 2x1, v2.1, Ext. Address D=DNET2x1 DE=DNET 2x1 Diagnostics HS1 F 2 N A A 2 NG A Ordering Number Example: HS1F2NAA2NGA Order appropriate mounting kits as noted below. Letter A Mounting Kits Shaft ode Actuator Pipe Size Stroke Plate Mounting Kit Numbers F ITT < 1" Up to.50" FLAT 281621-001 G Saunders < 1" Up to.50" FLAT 281621-001 H ITT 1-1/" to 2".50" - 1.685" EXT 281621-002 J Saunders 1-1/2" to 3".65" - 1.685" EXT 281621-002 K ITT Series 7 3" & " 1.62" - 1.685" FLAT 281621-001 Q ITT Series 33 3" & " 1.62" EXT 281621-002 L Gemu D6 1/2" to 1".320" to.533" FLAT 281621-003 M Gemu D6 1-1/" & 1-1/2"." to.75" FLAT 281621-003 Dimensions Inches.2 5 5.9 3/.NPT 3/.NPT 2.13.2 5 1.55 Mounting Plates (Included in mounting kit) FLAT Add 1/2" to overall height EXT Add 2-1/" to overall height 3.3 R1