Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Similar documents
Switching Power Supply

Switching Power Supply

LS200 Series Instruction Manual

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Inductive Proximity Sensor

Switch Mode Power Supply S8VS

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

S8VK-S (30/60/120/240/480-W Models)

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

E2EZ-X2D1-N E2EZ-X2D2-N

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

ZWD100PAF Series Instruction Manual

ZWD225PAF Series Instruction Manual

Inductive Proximity Sensor

TDK-Lambda ZWS240BP/A SPECIFICATIONS

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Model Number Structure

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Power Controller. (see note 1) 10 sec

Surface mounting, flush mounting, and DIN track mounting

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

RWS50B RWS100B RWS150B RWS300B RWS600B

Power Supply Technical Information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

H3DS-X - Solid State Two-Wire Timer

Model Number Structure

Model Number Structure

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Model Pressure range ON/OFF output Linear output

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

Model Number Structure

Basic Characteristics Data

Analog Input Terminal

PS6R 480W Switching Power Supply

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)

PS5R-S. Switching Power Supplies

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

PAF500F24 SERIES Instruction Manual

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

TDK-Lambda ZWS300BAF/A

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Technical Information Solid State Relays. Glossary. Solid State Relays

Model Number Structure

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Basic Characteristics Data

A22NK. Key-type Selector Switches

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Digital display Pressure range ON/OFF output Linear output Model

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

G3PE-Single-phase. Solid State Relays for Heaters

Manual Reset Limit Switch

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

DRB-1 Series Instruction Manual

DC/DC converters - MINI-PS DC/ 5-15DC/

POWER-WIN TECHNOLOGY CORP.

HWS Series Instruction Manual

Chapter. In This Chapter...

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Model Number Structure

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in)

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

PFE700SA Series Instruction Manual

HWS 15A-150A Series. Instruction Manual

Analog Output Terminal

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Transistor Remote Modules

Small Limit Switch D4V

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Power Supplies. Automation & Sensing. Selection Guide

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Model Number Structure

PAF F280 SERIES Instruction Manual

Ordering Information. Text PCB Power Relay G5LE

Transcription:

Switching Power Supply S82F Industrial-Grade Power Supply for General or Peak Load Applications Correct input voltage range is automatically selected: 1 VAC or 2 VAC. Model S82F-P is suitable for peak loads, such as solenoids and motors. Equipped with remote control, overcurrent, and overvoltage protection. Model S82F offers remote sensing feature. UL, CSA, and CE approvals (all models); also VDE approval for model S82F-P. 3-year warranty. Ordering Information SWITCHING POWER SUPPLIES Stock Shaded models are normally stocked. Rated input voltage Power ratings No. of outputs Output voltage Output current Part number 1 or 2 VAC 150 W 1 12 V 13.5 A S82F-1512 (automatically selected) 24 V 7 A S82F-1524 300 W 24 V 14 A S82F-3024 1 W (2 W at peak point) 2 W (480 W at peak point) 24 V 5 A ( A at peak point) S82F-1224P 24 V A ( A at peak point) S82F-2424P A mounting bracket is included with each power supply. MODEL NUMBER LEGEND S82F - 1 2 3 1. Power ratings 12: 1 W 15: 150 W 24: 2 W 30: 300 W 2. Output voltage 12: 12 V 24: 24 V 3. Peak-load doubling P: Available 156

Specifications Model S82F S82F-P Power rating 150 W 300 W 1 W (2W at peak point) Efficiency (typical) 75% to 80% (12 to 24 V) 83% to 85% Life expectancy yrs. min. (Used at C at the rated input with a 50% load) Output capacity 150 W 300 W 1 W (2W at peak point) 2 W (480 W at peak point) 2 W (480 W at peak point) Voltage (AC only) Frequency 1 V (85 to 132 V) or 2 V (170 to 264 V) automatically selected 47 to 0 Hz Current (with rated I/O) 0-V input 3.5 A max. 6.5 A max. 3.0 A max. (6.0 A at peak point) Leakage current (with rated I/O) 0-V input 0.5 ma max. 0-V input 2.5 A max. 4 A max. 1.8 A max. (3.6 A at peak point) 0-V input 1 ma max. Inrush current (with rated I/O) 0-V input 25 A max. Noise filter Output 0-V input 50 A max. Yes 5.5 A max. (11 A at peak point) 3.3 A max. (6.6 A at peak point) Voltage adjustment range Ripple variation influence Load variation influence Temperature variation influence Rise time Hold time ±% adjustable with variable resistor (V.ADJ) 12 V: 2 mv (p-p) max. 480 mv (p-p) max. 24 V: 480 mv (p-p) max. 1% max. (85 to 132/170 to 264 VAC input, 0% load) 2% max. (rated input, 0% to 0% load) 0.08%/ C max. (0 C to 50 C, with rated input and output) 800 ms max. (output voltage rise to 90%, with rated input and output) ms min. Additional functions Overload protection 5% min.(s82f)/2% min. (S82F-P) of rated load current (typical), drop type, automatic reset Overload voltage 1% of rated output voltage (typical), shut-off type, reset by input reset Remote sensing Yes No Remote control Yes Characteristics Ambient temperature Operating See the derating curve in the Engineering Data section. Storage C to 85 C ( 4 F to 185 F ) Ambient humidity Operating 30% to 90% Dielectric strength Insulation resistance Vibration resistance Shock resistance Output indicator Electromagnetic interference Approved standards Storage % to 95% 3000 VAC, 50/60 Hz for 1 min. (between all inputs and outputs) 2500 VAC for 1 minute between all inputs and outputs/housing 0 MΩ min. at 500 VDC (between all outputs and inputs/housing) Malfunction: to 55 Hz, 0.75-mm double amplitude (approx. 4.5G) for 2 h each in X, Y, and Z directions Malfunction: 294 m/s 2 (30G), 3 times each in ±X, ±Y, and ±Z directions Yes: red Conforms to FCC class A standards UL12, CSA E.B. 12, VDE 0160, CE Weight 1,650 g max. 2,850 g max. 1,800 g max. 3,250 g max. The input ry incorporates a surge absorber. Remove the short bar from the FG and ACG terminals before conducting a withstand voltage test or insulation resistance test. 157

Engineering Data DERATING CURVE The derating curve depends on the mounting position of the Power Supply. 1 Mounting Position 0 (A) Standard (Vertical) Installation (B) Horizontal Installation Top Top 80 (1) (2) (4) Load (%) 60 (3) A For mounting method A. Natural air-cooling: (1) + (2) Forced air-cooling: (1) + (2) + (3) + (4) ÉÉÉÉÉÉ B For mounting method B. Natural air-cooling: (1) Forced air-cooling: (1) + (2) + (3) 0 0 30 50 60 70 Ambient temperature C INRUSH CURRENT, START UP TIME, HOLD TIME ON AC input voltage OFF Inrush current on input application AC input current Output voltage Rise time 800 ms max. Hold time ms min. 158

OVERLOAD PROTECTION The power supply has an overload protection function that protects the load and the power supply from possible damage by overcurrent. When the output current rises above a set value (5% to 135% of the rated output current for S82F, and 2% to 230% of the rated output current for S82F-P), the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. Model S82F Model S82F-P Output voltage (V) Rated voltage Output voltage (V) 0 50 0 Output current (%) 0 0 0 Load current (%) OVERVOLTAGE PROTECTION The power supply is provided with an overvoltage protection function that protects the load and the power supply from possible damage by overvoltage. When the output voltage rises above a set value (1% of the rated output voltage), the protection function is triggered, shutting off the output voltage. If this occurs, reset the S82F by turning it off for seconds min. and then turning it on again. To reset the S82F-P, turn off the S82F-P for 60 seconds min. and then turn it on again. Be sure to turn on the power supply after the cause of the overvoltage output is found and the problem is solved. Approx. Overvoltage operation Output voltage (V) % % Rated output voltage % Variable range 159

Nomenclature S82F-15 (150 W) 4 3 5 1 6 S82F-3024 (300 W) 9 2 7 8 1. DC Output Terminals: Connect the load lines to these terminals. 2. Terminals: Connect the input lines to these terminals. 3. V.ADJ Adjuster: Adjusts the output voltage. 4. Output LED Indicator: Lights while a direct current (DC) output (+V, V) is ON. 5. Remote Sensing Terminals: Correct the voltage drop in the load lines. Shorted for normal operation. 6. Remote Control Terminals: Connected to an external device to enable remote control of the output while the input voltage is being applied. 7. ACG Terminal: The intermediate point of the input filter. Shorted to FG terminal for normal operation. 8. FG Terminal: Shorted to the housing, and connected to a ground line. 9. NC Terminals: Leave unconnected.. Short Bar 4 3 5 1 6 9 2 7 8 S82F-1224P (1 W) 4 3 1 5 9 S82F-2424P (2 W) 8 2 6 7 1. DC Output Terminals: Connect the load lines to these terminals. 2. Terminals: Connect the input lines to these terminals. 3. V.ADJ Adjuster: Adjusts the output voltage. 4. Output LED Indicator: Lights while a direct current (DC) output (+V, V) is ON. 5. Remote Control Terminals: Connected to an external device to enable remote control of the output while the input voltage is being applied. 6. ACG Terminal: The intermediate point of the input filter. Shorted to FG terminal for normal operation. 7. FG Terminal: Shorted to the housing, and connected to a ground line. 8. NC Terminals: Leave unconnected. 9. Short Bar 4 3 1 5 9 8 2 6 7 160

Operation PEAK-LOAD CURRENT (S82F-P) A peak load current waveform must satisfy the following condition. If the load current waveform of the S82F-P is pulse shaped, the rated capacity of the S82F-P need not be as large as the peak load current. The S82F-P corresponds to the peak load current twice as large as the rated capacity of the S82F-P. This means that he S82F-P is economical, space-saving and an ideal power supply for peak loads such as motors and solenoids. I av I m = Load current (%) Ip Im a 0 (I p a) τ T τ T + a Time (s) I p : Peak current value (0% max.) [A] I av : Rated output current [A] I m : Mean load current [A] τ: Pulse width (5 s max.) of peak current [s] T: Cycle [s] a: Continuous load current [A] If there is a current flow exceeding the peak current value, the overcurrent protection will work and output voltage will be lowered. If the mean load current continuously exceeds the rated output current, the output will be OFF. If this occurs, turn off the S82F-P for 60 seconds min. and then turn it on again. Corresponding Waveform Examples 5 5 5 5 Load current (%) 0 0 0 Time (s) REMOTE SENSING FUNCTION (S82F) This function corrects a voltage drop in the load wiring. When using the remote sensing function, remove the short bars from the remote sensing terminals as shown in the following diagram. REMOTE CONTROL FUNCTION The remote control function makes it possible to turn on or off the output without turning the power supply on or off. Load Remote sensing connection (2-conductor shielded cable) Wire connecting to load Remove the short bars. + S S Tr SW + RC RC Remove the short bar. Use the Tr with a V CE of 30 V min. and I C of 15 ma min. The terminal voltage is 0.4 V max. when the output is turned on. 1. When the voltage drop in the load wiring is large, the overvoltage protection function might engage due to the increase in voltage to correct the voltage drop, so be sure to use high capacity wiring. 2. If the +S and V or S and V terminals are left unconnected, the overvoltage protection function will engage and the output voltage will be cut off. 161

BLOCK DIAGRAM Model S82F ACG FG AC(L) AC(N) Fuse (see note) Noise filter Inrush current protection 0/0 V Automatically selected Rectifier and smoothing Rectifier Smoothing Overvoltage detector Overload detector DC OUT The fuse capacity must be 5 A at 150 W and A at 300 W. Auxiliary power supply Driver Switch + S S Remote sensing Limiting Photocoupler + R.C. Remote control R.C. Model S82F-P ACG FG AC(L) AC(N) Fuse (see note) Noise filter Inrush current protection 0/0 V Automatically selected Rectifier and smoothing Rectifier Smoothing Overvoltage detector Overload detector DC Output The fuse capacity must be 8 A at 1 W and 15 A at 2 W. Driver Switch Auxiliary power supply Limiting Photocoupler + R.C. Remote control R.C. 162

GENERATING OUTPUT VOLTAGE (±) An output of ± can be generated by using two power supplies (as shown), because the power supply produces a floating output. Load SERIES OPERATION The output of two power supplies can be connected in series to double the output voltage, as shown below. Load Load PARALLEL OPERATION The S82F power supplies can be connected in parallel to increase the output current. The S82F-P power supplies cannot be connected in parallel. Dimensions Unit: mm (inch) SWITCHING POWER SUPPLIES S82F-15 S82F-1224P 74 (2.91) Four, M4 mounting holes (6 mm deep on the opposite side) 230 (9.06) 160 50 1 (4.72) 80 M4 terminal screws Four, M4 mounting holes (6 mm deep) 7.5 Four, M3 mounting holes for the mounting bracket provided (4 mm deep, including the opposite side) 35 25 max. 7.5 160 0 Four, M3 mounting holes for the mounting bracket provided (4 mm deep, including the opposite side) 163

S82F-3024 S82F-2424P 146 (5.75) Four, M4 mounting holes (6 mm deep on the opposite side) 230 (9.06) 160 50 1 (4.72) 80 M4 terminal screws Four, M4 mounting holes (6 mm deep) 7.5 Four, M3 mounting holes for the mounting bracket provided (4 mm deep, including the opposite side) 90 28 25 max. 7.5 160 0 Four, M3 mounting holes for the mounting bracket provided (4 mm deep, including the opposite side) MOUNTING BRACKET (INCLUDED WITH POWER SUPPLY) Bottom Mounting 94 (3.70) Four, M4 166 (6.54) Four, M4 (1.57) (1.57) 95 (3.74) 95 (3.74) (0.39) (1.57) (0.39) (1.57) 164

Unit: mm (inch) Side Mounting (1.57) 95 (1.57) (3.74) (1.57) 95 (1.57) (3.74) 1 (5.51) 1 (5.51) 230 (9.06) Four, M4 230 (9.06) Four, M4 Mounting Holes Two, 3.2-dia. holes (for mounting the power supply) Two, 5-dia. mounting holes Attach the mounting bracket to the power supply and secure it with two screws. Then attach the mounting bracket to the panel. 60 (2.36) (1.77) (1.57) (0.79) 15 (0.59) Precautions MOUNTING The power supply is designed to dissipate heat through natural air-flow. To improve and maintain the reliability of the power supply over a long period of time, mount the power supply so that air flow takes place around it. We recommend mounting the Power Supply to a steel plate. When mounting two or more power supplies side-by-side, allow at least mm spacing between them, as shown in the following illustration. Forced-air cooling is recommended. mm min. Steel plate Air 165

Cat No. GC PS6 2/03 Specifications subject to change without notice Printed in USA