NOVATEK-ELECTRO LTD Research-and-Manufacture Company. Legat-5M. Voltage Stabilizer. Technical Certificate.

Similar documents
NOVATEK-ELECTRO LTD Research-and-Manufacture Company Voltage Stabilizer Legat-15

NOVATEK-ELECTRO LTD Research-and-Manufacture Company Voltage Stabilizer Legat-35

Legat-65. Voltage Stabilizer Technical Certificate. NOVATEK-ELECTRO LTD Research-and-Manufacture Company

UNIVERSAL SINGLE PHASE INDUCTION ELECTRIC MOTOR PROTECTION UNIT

UNIVERSAL SINGLE-PHASE INDUCTION ELECTRIC MOTOR PROTECTION UNIT WITH THE POSSIBILITY OF SOFT START

NOVATEK-ELECTRO LTD Research-and-Manufacture Company SINGLE PHASE VOLTAGE MONITORING RELAY RN-113 USERS MANUAL

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

OWNER S MANUAL POWER INVERTER

Phoenix Inverter

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

Working Principle of Power Saver as per Manufacture:

Application Engineering

1 Safety instructions

Application Engineering

1RECHARGEABLE APPLIANCES

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

AF series contactors (9 2650)

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

AUTOMATIC STANDBY ACTIVATION. Operation Manual

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

RVS-AX Instruction Manual

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

AF series contactors (9 2650)

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Inverter User Manual

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

Battery Power Inverters

MODEL 422 Submersible Pump Controller

The Power of Reliability INSTRUCTION MANUAL

Technical Manual Electrical Power Supply System T4002

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

TABLE OF CONTENTS. 300 W Mobile Power Outlet SAVE THESE INSTRUCTIONS!

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

ELECTRICAL SYSTEM RP-7

MYRON ZUCKER CALMANUAL POWER FACTOR CORRECTION APPLICATION GUIDE INC.

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

Table of Contents 文管中心 發行章

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

12VDC TO 230VAC INVERTERS

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

S150,S300 Series Pure Sine Wave Inverter User s Manual

ST Charger. Industrial Battery Charger

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

SECTION MOTOR CONTROL

Owner s Guide. DC TO AC Power Inverter

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Integral Horsepower DC Motor & Generator Application Data CA608D

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

GENSET CONTROL MODULE A121A / A241A

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

WARNINGS, CAUTIONS AND NOTES

powerdriveinverters.com Owner s Guide Please Save for Future Reference 300 Watt DC to AC Power Inverter

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

PureSine 150/300 Pure Sine Wave Inverter User s Manual

Chapter 3.1: Electrical System

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Differential Pressure Transmitter

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

Parr Instrument Company

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

MAGNETIC MOTOR STARTERS

Is Your Factory Power Source Corrupting Your Product Testing? September 2015 Author: Steve Boegle Engineering Group Leader, Behlman Electronics

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Foreword. Manual instruction

INDEX Section Page Number Remarks

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

707Ex. Users Manual. ma Calibrator

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

LS200 Series Instruction Manual

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

IVT-1260 & IVT Generator Auxiliary Excitation Booster Operation Manual. (Patent Pending)

Installation and Operating Instructions. Solar System Controller ISC3020

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

10.0 Alternator Test

Grounding Of Standby & Emergency Power Systems

NFC. (Varistor Type NFC)

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

DKG-114 MANUAL AND REMOTE START UNIT

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Transcription:

NOVATEK-ELECTRO LTD Research-and-Manufacture Company Legat-5M Voltage Stabilizer Technical Certificate www.novatek-electro.com

1. Application 2 Legat-5 single-phase voltage stabilizer, hereinafter referred to as the stabilizer, is designed for providing different consumers with high-stable power supply. The stabilizer is designed for use in non-explosive environment that does not contain abrasive and conductive dust, corrosive vapors and gases in concentrations of metals and destroy the insulation, at ambient temperatures from -10 to +40 C, relative humidity of 60 to 80% atmospheric pressure of 86 to 106.5 kpa. 2. Technical Brief Operation voltage range, V..90-420 Maximum output current, A.2.2 Maximum output power (at input voltage of 180-259V), VA.500 Maximum output power at upper value of input voltage, VA.300 Output power, V.adjustable, 200-240, with the step of 1V Output voltage stabilization accuracy, %.1.5 Input voltage range at preserved operability, V 90-450 Mains frequency, Hz.50/60 Amount of phases single-phase Maximum tripping time at abrupt input voltage deviation by 40V, sec 0.05 Efficiency factor at 160V<Uвх (Uinput)<240, not less than %...91 Power factor at stabilizer input at active output load of 500W, not less than 0.98 Nonlinear distortion factor of output voltage, not more than.1% Overload multiplicity.1.5 Load tripping delay, sec adjustable 0-300 Load shedding delay at overloading, sec 1-15 (depending on the overload extent with linear power-time relation of 110% - 15 sec, 150% - 1 sec) Allowable cosφ 0.4 Weight, kg..3,5 Dimensions, mm.230x90x170 Cooling natural Protection class ( leaking).ip20 Caution! It is strongly prohibited to put any objects, capable of blocking the air flow, onto the upper cap of the stabilizer. 3. Construction and Operation Principle The stabilizer operation principle is based on output voltage adjustment by means of pulseduration modulation. At the input and output of the device, there are analog filters, effectively smoothing the impulse noise in the circuit. The stabilizer has the applied transit scheme of a neutral wire from the input to the output of the device, which allows connecting the consumer s equipment, operability of which depends on input voltage phasing correctness. The stabilizer has two operation modes: - VIP mode, in which there is applied stabilization of accurately determined voltage with the error of ±1.5% within the output voltage adjustment (200-240V); - economical mode, in which stabilization is accomplished beyond the established output voltage range. The output voltage within the limits, established by the user, equals the input

voltage virtually without energy loss, which allows significant saving the electric energy. The minimum allowable range limit is 200V, the maximum one is 240V, which does not exceed the limits of technical information of the most of devices. The stabilizer faceplate contains (see. figure): - adjusting knobs for setting the output voltage and the stabilizer startup delay time; - digital display for indication the input and output voltage, and for stabilizer load indication; - fault indicators; - 4A input fuse; - output socket. From the moment of the stabilizer startup, with the period of 3 sec the digital voltage display alternately shows the input voltage, the stabilizer loading percentage, and the output voltage, indicated by the corresponding indicators. The load is tripped after the time, established by the user (factory setting is 3 sec). In case of output overload, the overload indicator starts to glow. In cases of tripping of voltages with high values of starting current (induction motors, demagnetizing systems of television kinescopes, high-power incandescent lamps), the output voltage reduction is allowable for the period of startup of the aforementioned devices. This function allows reducing the high starting currents and prevents the stabilizer output form shedding. Recommendation: If the stabilizer Legat-5M operates on stand-alone gasoline (diesel) generator, the output voltage which changes the frequency and amplitude, has a large distortion (10%), the need to translate Dimo-stabilizer in Economy mode (with Δ 10 V). In case of a load surge exceeding the 100% of power, the load will be cut off according to the linear power-time relation. In case of short circuit (SC), the integrated SC protection trips, the load is cut off and the SC indicator starts to glow. In such a case, to resume the load tripping one should either reset the stabilizer (by removing the plug from the mains socket), having preliminarily shut down some electric devices and reduced the power consumption to the allowed value, or remove the cause of SC. If the input voltage becomes beyond the limits of the operation voltage range, the load will be cut off and the input fault indicator will start to glow. The stabilizer will automatically trip the load after input voltage resumption (with the delay, preset by the user). The stabilizer has the overheat protection. In case of overheat, the load is cut off and the overheat fault indicator starts to blink. After cooling the device, the load trips with the preset tripping time. The Table 1 shows the correspondences between the possible fault variants and the fault indicators, as well as the methods of troubleshooting. Table 1. Fault description Fault indicator Troubleshooting Input Short Overheat Overload circuit 1 Overheat - - - + Reduce the total load power 2 Input SC - + - - Remove SC, stabilizer on/off 3 input voltage U вх <U вх. min U вх <U вх. max + - - - Stabilizer not appropriate for this circuit 4 Thermal fault - - + - De-energize the stabilizer, eliminate external sources of heat 3

4 4. USE OF PURPOSE 4.1.Preparing the Stabilizer for Operation perform the external inspection of the stabilizer to discover any damage to the housing and to the power cable; make sure to provide ground connection to the circuit socket; connect the stabilizer to the circuit without application of any load; apply load. WARNING! Stabilizer Legat-5M represents a capacitive load (about 1.7 uf) to the mains, so when working from an independent gasoline (diesel) generator may be a spurious resonance winding of the generator with the specified input capacitance. The consequence of this resonance increases the output voltage at no-load generator and the input voltage for the regulator, which can be seen on the scoreboard stabilizer Uin. In order to rise in voltage due to resonance was negligible 10 20% to comply with the requirement: full power of the generator should not be less than 2 times the power of the stabilizer. 4.2. Adjustment Economical mode. For performing adjustment one should separately set the lower and the upper limits of the output voltage range, when the output voltage is equal to the input one. Setting the lower limit is performed by turning the Uвых,В (Uoutput,V) knob. The digital display shows the set voltage value on the background of three points. To save the set voltage value in the memory of the stabilizer and exit this setting, one should wait for 3-4 sec. To set the upper limit one should perform the aforementioned actions with the U,В ( U,V) (values are from 0 to 40), i.e. the output voltage can acquire values from Uвых to Uвых + U. If one sets zero value by turning the U,В knob, the stabilizer will operate in the VIP mode. Setting the reset time is performed by turning the Твкл(сек) (T on(sec)). 5. Security measures While choosing a stabilizer, one should take into account the total power consumption of the load. Inside the housing of the stabilizer, there is voltage that is dangerous to life. It is strongly prohibited: - to crush the stabilizer; - to connect to the mains and to operate an ungrounded stabilizer; - to operate the stabilizer, when any of its housing parts is deformed so that it contacts the current-conducting parts; - to operate the stabilizer at inefficient work of the switch, at the signs of smoke or smell, typical for burning insulation; - to store and to operate the stabilizer in the rooms with chemically active or explosive environment. WARNING! Do not put on top of the stabilizer of any objects that might impede the flow of air. 6. Maintenance CAUTION! All maintenance works must be performed, when the plug is off.

5 7. Transportation and Storage It is allowed to transport the stabilizer in the vertical position by any means of transport. The stabilizer must be stored at the air temperature starting from -40 С to +60 С and at the relative air humidity up to 80%. In the storage room, there must not be any dust, acid and alkali vapor, which may cause corrosion. 8. Warranty The manufacturer guarantees the failproof operation of the Legat-5 stabilizer within twelve months after the date of sale, provided: - correct connection; - manufacturer s quality control department seal integrity; - integrity of the housing, no traces of unsealing, no cracks, chips etc. When choosing a stabilizer is important to remember! While choosing a stabilizer, one should take into account the total power consumption of the load, which you want to connect to the stabilizer. The total power is all the power, consumed by an electric device, and it consists of active and reactive power (depending on the type of load). The active power is always specified in Watts (W), while the total power in volt-amperes (VA). The devices are consumers of the electric energy, having both active and reactive components of the load. The total power (VA) and the active power (W) are interrelated by the cosφ factor. The active load. At this type of load, all the consumed energy is transformed into heat. Some devices have this component as the main one. Examples: incandescent lamps, heaters, electric stoves, irons etc. The reactive load. All the other types. The reactive component of the power does not perform any useful work, it only serves for conducting magnetic fields in inductive receivers, while circulating all the time between the source and the consumer. High starting currents. At the moment of start-up, any electric motor consumes the energy, which is several times bigger than in the normal mode. In case when the load contains an electric motor, which is the main consumer in the device (for instance, submersible pump, refrigerator etc.), its nameplate power consumption must be multiplied by 3 to avoid the stabilizer overload at the moment of starting. Proceeding from all the aforementioned, it is recommended to choose the stabilizer model with a 25% margin of the load power consumption. You will provide the partial load mode of the stabilizer, thereby increasing its service life.