Model M B. Strain Gage Load Cell. Installation and Operating Manual

Similar documents
Model B STRAIN GAGE LOAD CELL. Installation and Operating Manual

Model 086C05. Installation and Operating Manual

Model 377B10. Condenser Microphone. Installation and Operating Manual

Model 622B01. Industrial ICP Accelerometer. Installation and Operating Manual

Model 070A80. Front Panel Display. Installation and Operating Manual

Model 393B31. Seismic, high sensitivity, ceramic flexural ICP accel., 10 V/g, 0.1 to 200 Hz, Installation and Operating Manual

Model 378B02. ICP Microphone System. Installation and Operating Manual

Model 134A24 Tourmaline ICP pressure bar, 1000 psi, 5 mv/psi, 0.2 microsecond rise. Installation and Operating Manual

Model 102B15. ICP Pressure Sensor. Installation and Operating Manual

Load Cells. For Test, Measurement, and Monitoring Requirements in Automotive, Aerospace, R&D, and Process Control Applications

Model A LOW PROFILE LOAD CELL. Installation and Operating Manual

Model 643A ma Output Velocity Sensor. Installation and Operating Manual

Model 648A ma Output Accelerometer. Installation and Operating Manual

Sensors for Road Load Measurements Accelerometers, Pressure Sensors, Force Sensors, Strain Sensors, Load Cells, and Signal Conditioners

WHITE PAPER. Detecting Rolling Element Bearing Faults Using the Echo Wireless Vibration Monitoring System

Model ADB FATIGUE RATED LOW PROFILE LOAD CELL, DUAL BRIDGE. Installation and Operating Manual

SWIFT Evo SPINNING WHEEL INTEGRATED FORCE TRANSDUCER

KM26z 20N; 50N; 100N, 200N, 500N, 1kN, 2kN, 5kN

Motorsport Sensors

HI HLPT SERIES LOAD POINT ASSEMBLIES OPERATION AND INSTALLATION MANUAL

K3D300 ±200kN. Description

K3D300 ±50kN. Description

KD45 ±20N. Description

What is the secret to our success?

Model HT640B02. High Temperature 4-20 ma Output Velocity Sensor. Installation and Operating Manual

WHITE PAPER. Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels

INSTALLATION DATA MANUAL MODEL 148/248/348

MCRT 27000T Non-Contact WHEEL TORQUEMETERS (TORQUE WHEELS) Designing and Making the World s Best Torque Instruments Since 1960

Model 3400 Intrinsically Safe Load Cell

Load Cell for Manually Operated Presses Model 8451

Tension and Compression Load Cell Model 8435

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

Precision Load Cells. The World of Precision Made Force Transducers. A world of experience TEST AND MOTION SIMULATION

Web Tension Technology

A22 / A6 MINIATURE FORCE SENSOR

Fax or to SENTRAN Applications Engineering Group: (909) or

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

ELE744 Fall 2006 Load Cell Test Jig

Quality Since 1980 SERVICE GUIDE. Eliminator Series HD, HDL, HDR, SD EDrive Actuators, Inc. #FB6070 Linear Actuators

Engineering Specifications

Cleveland-Kidder. Design Features

FORCE SENSORS FORCE SENSORS

Virtual Measurements & Control. VC210 Operators Manual

Using the LCT100 for Load Cell Troubleshooting

The platform is placed on the weighing platform using three or four height-adjustable elastomer bearings (EL 120), in order to avoid twisting.

Transmitter CSA-591 Instruction Manual

TRANSDUCER INSTRUCTION MANUAL... TYPE SLIM CELL TRANSDUCER. INSTRUCTION NUMBER: AO of 9

Multi-Range, Rigid Stem Melt Pressure Transducer

Model 6A Series 6-Axis Load Cells (Fx Fy Fz Mx My Mz)

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

Model: SR635i Pediatric Scale with Cart Operating and Service Manual Part No.: MAN635i_ Page 1 of 18. Model SR635i. Pediatric Scale with Cart

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Pressure Sensors for Test and Measurement. For Precise Pressure Measurement in Static and Dynamic Applications

HI LPRC03 Advantage Hermetic Rocker Load Points

SPECIFICATION SHEET Pulse tool / Impact Wrench Testing System MODEL : IWT-101

SEAT BELT LOAD CELL. Load cell that measures the forces at the seat belt during automotive crash or sled tests.

PVI 60KW, PVI 82KW, PVI 95KW

WHITE PAPER. Driveshaft/Axle On-track Torque Measurement Continuous high speed torque measurements for vehicle performance testing.

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

DC REGULATED POWER SUPPLY

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Installation and Operating Manual

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

DYNAMIC ICP PRESSURE SENSORS

User s Guide. TQ513 Series Rotating Torque Sensors Shaft-to-Shaft Configuration. Shop online at omega.com

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

OWECON OWL500 Roller Load Cell Series

Digital Torquemeters

MSI SINGLE IDLER BELT SCALE

Sturtevant Richmont. PST 1000 (P/N 10478) Owners Manual

Piezoresistive Pressure Sensor

TELEDYNE HASTINGS INSTRUMENTS

Cleveland-Kidder Ultra

User's Manual. Earth Ground Resistance Tester. Model Introduction

ENC 150 REFERENCE MANUAL ACU-RITE

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Instruction Manual. Vibration Severity Meter VM12

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Rental Industry Safety Tester Safe Check 5s

Physical Principle M. Dahlberg, MECH 207, Fall 2009

OPERATING INSTRUCTIONS

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)

Air Bearing Shaker for Precision Calibration of Accelerometers

Piezoresistive Absolute Pressure Sensor

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

force/torque solutions by sensor type

INSTALLATION DATA MANUAL. Model 521/522 Pressure Transmitter

Defender 3000 Series Base Instruction Manual

GE Sensing & Inspection Technologies

Washdo. wn Scale Base

METEOROLOGICAL INSTRUMENTS

Caution. Description. Specifications and Ordering Information and Accelerometers

MSI SINGLE IDLER BELT SCALE

200 Series Flow Meters

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Transcription:

Model M1204-02B Strain Gage Load Cell Installation and Operating Manual For assistance with the operation of this product,contact: PCB Load & Torque, Inc. Toll-free: 866-684-7107 24-hour SensorLine : 716-684-0001 Fax: 248-888-8266 E-mail: LTInfo@pcbloadtorque.com Web: www.pcbloadtorque.com

Warranty, Service, Repair, and Return Policies and Instructions The information contained in this document supersedes all similar information that may be found elsewhere in this manual. Total Customer Satisfaction PCB Piezotronics guarantees Total Customer Satisfaction. If, at any time, for any reason, you are not completely satisfied with any PCB product, PCB will repair, replace, or exchange it at no charge. You may also choose to have your purchase price refunded in lieu of the repair, replacement, or exchange of the product. Service Due to the sophisticated nature of the sensors and associated instrumentation provided by PCB Piezotronics, user servicing or repair is not recommended and, if attempted, may void the factory warranty. Routine maintenance, such as the cleaning of electrical connectors, housings, and mounting surfaces with solutions and techniques that will not harm the physical material of construction, is acceptable. Caution should be observed to insure that liquids are not permitted to migrate into devices that are not hermetically sealed. Such devices should only be wiped with a dampened cloth and never submerged or have liquids poured upon them. Repair In the event that equipment becomes damaged or ceases to operate, arrangements should be made to return the equipment to PCB Piezotronics for repair. User servicing or repair is not recommended and, if attempted, may void the factory warranty. Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data. Equipment calibration cycles are typically established by the users own quality regimen. When in doubt about a calibration cycle, a good rule of thumb is to recalibrate on an annual basis. It is also good practice to recalibrate after exposure to any severe temperature extreme, shock, load, or other environmental influence, or prior to any critical test. PCB Piezotronics maintains an ISO- 9001 certified metrology laboratory and offers calibration services, which are accredited by A2LA to ISO/IEC 17025, with full traceablility to N.I.S.T. In addition to the normally supplied calibration, special testing is also available, such as: sensitivity at elevated or cryogenic temperatures, phase response, extended high or low frequency response, extended range, leak testing, hydrostatic pressure testing, and others. For information on standard recalibration services or special testing, contact your local PCB Piezotronics distributor, sales representative, or factory customer service representative. Returning Equipment Following these procedures will insure that your returned materials are handled in the most expedient manner. Before returning any equipment to PCB Piezotronics, contact your local distributor, sales representative, or factory customer service representative to obtain a Return

Materials Authorization (RMA) Number. This RMA number should be clearly marked on the outside of all package(s) and on the packing list(s) accompanying the shipment. A detailed account of the nature of the problem(s) being experienced with the equipment should also be included inside the package(s) containing any returned materials. A Purchase Order, included with the returned materials, will expedite the turn-around of serviced equipment. It is recommended to include authorization on the Purchase Order for PCB to proceed with any repairs, as long as they do not exceed 50% of the replacement cost of the returned item(s). PCB will provide a price quotation or replacement recommendation for any item whose repair costs would exceed 50% of replacement cost, or any item that is not economically feasible to repair. For routine calibration services, the Purchase Order should include authorization to proceed and return at current pricing, which can be obtained from a factory customer service representative. Warranty All equipment and repair services provided by PCB Piezotronics, Inc. are covered by a limited warranty against defective material and workmanship for a period of one year from date of original purchase. Contact PCB for a complete statement of our warranty. Expendable items, such as batteries and mounting hardware, are not covered by warranty. Mechanical damage to equipment due to improper use is not covered by warranty. Electronic circuitry failure caused by the introduction of unregulated or improper excitation power or electrostatic discharge is not covered by warranty. Contact Information International customers should direct all inquiries to their local distributor or sales office. A complete list of distributors and offices can be found at www.pcb.com. Customers within the United States may contact their local sales representative or a factory customer service representative. A complete list of sales representatives can be found at www.pcb.com. Toll-free telephone numbers for a factory customer service representative, in the division responsible for this product, can be found on the title page at the front of this manual. Our ship to address and general contact numbers are: PCB Piezotronics, Inc. 3425 Walden Ave. Depew, NY 14043 USA Toll-free: (800) 828-8840 24-hour SensorLine SM : (716) 684-0001 Website: www.pcb.com E-mail: info@pcb.com DOCUMENT NUMBER: 21354 DOCUMENT REVISION: B ECN: 17900

Model Number M1204-02B STRAIN GAGE LOAD CELL Performance ENGLISH SI Measurement Range 22 klb 100 kn [5] Sensitivity(± 10 %) 3 mv/v 3 mv/v [6] Non-Linearity 0.05 % FS 0.05 % FS Hysteresis 0.05 % FS 0.05 % FS Non-Repeatability 0.02 %RO 0.02 %RO Resonant Frequency 9 khz 9 khz Environmental Overload Limit 37.5 klb 167 kn Load Limit(Side Force, F X or F Y ) 12.5 klb 56 kn [3] Load Limit(Bending Moment, M X or M Y ) 12.5k in-lb 1412 N-m [3] Load Limit(Axial Torque, M Z ) 12.5k in-lb 1412 N-m [3] Temperature Range(Operating) -65 to +200 F -54 to +93 C Temperature Range(Compensated) +70 to +170 F +21 to +77 C Temperature Effect on Output(Maximum) ± 0.002 %Reading/ F ± 0.0036 %Reading/ C [4] Temperature Effect on Zero Balance(Maximum) ± 0.001 %FS/ F ± 0.0018 %FS/ C [4] Electrical Bridge Resistance 700 ohm 700 ohm [1] Excitation Voltage(Recommended) 10 VDC 10 VDC [2] Insulation Resistance >5x10 9 ohm >5x10 9 ohm Zero Balance 1.0 % FS 1.0 % FS Physical Size (Diameter x Height) 6.06 in x 1.75 in 153.9 mm x 44.5 mm Weight 8.96 lb 4.06 kg Mounting Thread No English Equivalent M33 x 2-4H Female Sensing Element Strain Gage Strain Gage Deflection at Full Scale Capacity 0.0015 in 0.038 mm Housing Material Painted Steel Painted Steel Electrical Connector PC04E-10-6P PC04E-10-6P Electrical Connection Position Side Side All specifications are at room temperature unless otherwise specified. In the interest of constant product improvement, we reserve the right to change specifications without notice. ICP is a registered trademark of PCB Group, Inc. Revision: B ECN #: 37851 OPTIONAL VERSIONS Optional versions have identical specifications and accessories as listed for the standard model except where noted below. More than one option may be used. NOTES: [1] Nominal. [2] Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS. [3] Singularly applied, i.e. no other extraneous loads. [4] Over compensated operating temperature range. [5] FS - Full Scale. [6] RO - Rated Output. OPTIONAL ACCESSORIES: Model 182-025A PCO6A-10-6S(SR) Model M084A101 TENSION LOAD BASE W/ M33X2 THD. Entered: DMW Engineer: JSD Sales: JC Approved: GLB Spec Number: Date: 12/6/2011 Date: 12/6/2011 Date: 12/6/2011 Date: 12/6/2011 48097 PCB Load & Torque, Inc. 24350 Indoplex Circle Farmington Hills, MI 48335 UNITED STATES Phone: 866-684-7107 Fax: 716-684-0987 E-Mail: ltinfo@pcbloadtorque.com Web site: http://www.pcbloadtorque.com