METHANOL-FIRED FUEL CELL POWER SYSTEM FOR REMOTE APPLICATIONS

Similar documents
DYNAMIC MODELING RESIDENTIAL DATA AND APPLICATION

Effect of Hybridization on the Performance of Fuel Cell Energy/Power Systems (FCEPS) for Unmanned Aerial Vehicle (UAV)

Dynamic Behaviour of a Fuel Cell with Ultra Capacitor Peak Power Assistance for a Light Vehicle

GENCORE 5 FUEL CELL SYSTEM System Fundamentals

Renewable Energy for Minnesota. Progress in Fuel Cell Research at CPG

Application. Battery. Public Grid GS HYBRID INVERTER

Generator Efficiency Optimization at Remote Sites

Economic Dispatch and SCADA for Diesel Efficiency Improvements *

ANALYZING POWER LOSSES AND THEIR EFFECTS IN COMPLEX POWER SYSTEMS

Ballard Power Systems

AARHUS UNIVERSITET FLOW BATTERIER PÅ VEJ IND I KOMMERCIEL DANSK SERIEPRODUKTION

Power Management in a Standalone Solar/ Fuel cell/ Battery Hybrid Power system

Control System for a Diesel Generator and UPS

Flywheel as High Power Storage Devices for Grid Load Balancing and Stabilization

FEMAG-C. Serial hybrid generator for electric city cars. Hybrid Small Fuel Cells Domenico Serpella LABOR S.r.l. (ITALY)

Energy Storage and Other Energy Control Solutions

Asia Pacific Research Initiative for Sustainable Energy Systems 2011 (APRISES11)

The evaluation of endurance running tests of the fuel cells and battery hybrid test railway train

Cross Flow Heat Exchanger H352

Experimental Study on the Effects of Flow Rate and Temperature on Thermoelectric Power Generation

Ampd Silo. Energy Storage System. Maintenance-free Li-ion energy storage for mission critical backup. Power to Empower

Ardalan Vahidi. Clemson Renewable Energy Systems Lab Mechanical Engineering Clemson University

Testing Energy Storage Systems: From EVs to Utility Grid

DEMONSTRATION OF A HYDROGEN FUEL CELL LOCOMOTIVE

Inverter Testing at Sandia National Laboratories*

4 What We Know About Fuel Cells

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

Using the Phoenix MultiPlus to reduce operating cost of a generator

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

2011 Advanced Energy Conference -Buffalo, NY

StorEdge Solar and Energy Storage System Review

Nexa 1200 Fuel Cell System

Cross Flow Heat Exchanger H352

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Smarter Solutions for a Clean Energy Future

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

O&M Requirements for Utility-Scale Solar PV and Energy Storage. Nicholas Jewell, Ph.D., PMP Sr. Research Engineer Research & Development LG&E and KU

L kw Distributed Energy Storage System Unit (SU50)

New Technologies for Fuel Cells in Future Powertrain Applications

Description Sets the priority for the AC source (AC1 or AC2) for qualification and transfer.

Comparative experimental study of the performance of two different types of HTPEM MEAs

Why Is My PV Module Rating Larger Than My Inverter Rating?

Custom Power Solar Radian Battery Energy Storage System

renewable energy and energy efficiency

Microgrid with Solar Power and Fuel Cell Technology

PowerCell Sweden AB. Dr. Per Ekdunge. H2 and Fuel Cells in maritime application June 2017, Valencia

Hydrogen Station Equipment Performance Device (HyStEP Device) Specification

Accelerated Testing of Advanced Battery Technologies in PHEV Applications

Valve Accessories. Limit switches, solenoid valves, lock-up valves, supply pressure regulators, volume boosters, quick exhaust valves, applications

Modeling and Comparison of Dynamics of AC and DC Coupled Remote Hybrid Power Systems

GRANT AGREEMENT

Formation Flying Experiments on the Orion-Emerald Mission. Introduction

SJSU ENGR 10 Wind Turbine Power Measurement Procedure

Wind Turbine Emulation Experiment

Autonomous Power Supply Uninterruptible Power Supply (UPS)

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Real-Time Simulation of A Modular Multilevel Converter Based Hybrid Energy Storage System

Module-Integrated Power Electronics for Solar Photovoltaics. Robert Pilawa-Podgurski Power Affiliates Program 33rd Annual Review Friday, May 4th 2012

A Novel Proton Exchange Membrane Fuel Cell-Battery Partial Hybrid System Design for Unmanned Aerial Vehicle Application. Dr.

GS-100D+ Preconfigured Kits Manual

Armands Senfelds, Leonids Ribickis, Ansis Avotins, Peteris Apse-Apsitis

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

APPLICATION OF BOOST INVERTER FOR GRID CONNECTED FUEL CELL BASED POWER GENERATION

OSU Research Program In Mechatronic Systems. Ali Keyhani Mechatronics Laboratory Dept. of Electrical Engineering The Ohio State University

MRC Field Trial Performance Report (Hugoton Deep Reservoir in Kansas) Revision 1.9

VERITY Purification Systems Build the perfect system to fit your research

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Fuel Cell Systems Product Overview. Systems

Model of the Air System Transients in a Fuel Cell Vehicle

Isolated Bidirectional DC DC Converter for SuperCapacitor Applications

Comparing the powertrain energy and power densities of electric and gasoline vehicles

Solar inverter From Wikipedia, the free encyclopedia

WindLab TM Wind Turbine Power System Sample Laboratory Procedure Manual

SERVERS POWERED BY A 10KW IN-RACK PROTON EXCHANGE MEMBRANE FUEL CELL SYSTEM

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

Ballard Power Systems

Antares DLR-H2 - Flying Test Bed for Development of Aircraft Fuel Cell Systems

DC Microgrids and Distribution Systems for Residences

Behaviour of battery energy storage system with PV

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

MONITORING AND RESEARCH DEPARTMENT

Evaluating Batteries: Deployment, Integration and Market Drivers

Pika Energy Island Made in America

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

Adaptive Fault-Tolerant Control for Smart Grid Applications

Energy Security Electrical Islanding Approach and Assessment Tools. Dr. Bill Kramer Senior Research Engineer Distributed Energy Systems Integration

CHAPTER 1 INTRODUCTION

SimpliPhi Power PHI Battery

HIGH VOLTAGE, HIGH CURRENT, HIGH DI/DT SOLID STATE SWITCH

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

HYBRID POWER FOR TELECOM SITES

Off-grid Power for Wireless Networks. Training materials for wireless trainers

» IMPROVED EFFICIENCY» IMPROVED PRODUCTIVITY» POWER QUALITY» LOW-CARBON ENVIRONMENT.

Hybrid and Fuel Cell Vehicles. Internal Combustion Engines

Glossary. * Credit for glossary starter: Florida Solar Energy Center. August 2015 PV Installer's Course: Glossary 1

CERTIFICATE OF ACCREDITATION

RTG EcoCrane In-Use Emissions and Fuel Economy Test Program at POLA

System selection for Stand-alone S

TekStak Educational Fuel Cells

Transcription:

Presented at 15 th Annual U.S. Hydrogen Conference, April 26-3, 24, Los Angeles METHANOL-FIRED FUEL CELL POWER SYSTEM FOR REMOTE APPLICATIONS C.E. Chamberlin 1, G.S. Chapman 1, M.W. Marshall 1, D.S. Rommel 1, A.M. Reis 1, M.L. Winkler 1, P.A. Lehman 1, D.E. Witmer 2 and T.H. Johnson 2 1. Introduction Remote areas of Alaska need reliable, efficient, and clean electric power generators for remote homes, telecommunications stations, weather stations, and pipeline, oil, and gas monitoring equipment. A methanol-fired fuel cell power system (FCPS) can meet these requirements, with the added benefits that it produces no harmful emissions that would damage the fragile Alaskan environment and uses a fuel that is already widely available in Alaska. The goals of this project were: Design and build a methanol-fired proton exchange membrane (PEM) fuel cell power system to support a 1 kwh per day dynamic load and deliver up to 1 kw continuous, grid-quality AC power, with peaking to 1.5 kw. Develop a control system that provides seamless integration of the methanol reformer and the PEM fuel cell and provides automatic and safe operation. Test the steady state and dynamic performance of the system at the Schatz energy Research Center in Arcata, California. Deliver the completed brass-board system to the Arctic Energy Technology Development Laboratory at the University of Alaska, Fairbanks, Alaska, for final system qualification. In this paper, we describe the results of preliminary testing of the steady state and dynamic response of the methanol reformer and the system design and operation. We also report the results of steady state and dynamic performance tests of the complete system at SERC and at the Arctic Energy Technology Development Laboratory, including an analysis of methanol-to-ac power system efficiency. 2. Reformer Testing One of the major challenges in producing the fuel cell power system for this project was the integration of the IdaTech FPM 2 methanol reformer and the SERC 4- cell, 3 cm 2 PEM fuel cell stack. The SERC PEM fuel cell runs dead-ended on the 1 Schatz Energy Research Center, Humboldt State University, Arcata, CA 95521, phone: 77-826-4345, fax: 77-826-4347, email: serc@humboldt.edu 2 Arctic Energy Technology Development Laboratory, University of Alaska, Fairbanks, AK 99775

hydrogen side with brief purges at timed intervals. Each purge releases about 1 standard liter (sl) of hydrogen in a 1 second interval, thereby temporarily increasing the hydrogen flow rate by about 6 standard liters per minute (slm). When the power demand on the fuel cell steps up or down, the stack current and consequently the hydrogen consumption immediately steps up or down proportionally. On the other hand, the reformer does not immediately respond to a change in control signal and so the reformer hydrogen production rate cannot closely match or track the fuel cell consumption rate. After receipt of the reformer from IdaTech, we installed it on a test bench where we could communicate with the reformer's internal controller, measure the hydrogen production rate and pressure, and use a mass flow controller to simulate the fuel cell's hydrogen consumption rate and associated purges. With this setup we were able to become adept at using and controlling the reformer and to experiment with various approaches to integrating the reformer and the fuel cell. We began by exploring how the reformer's steady state hydrogen production rate depended on the control signal to the reformer and the delivery pressure. Figure 1 shows the steady state hydrogen production rate vs. the control signal for three delivery pressures:, 1, and 2 psig. The control signal can range from to 1. 25 Hydrogen Production Rate (slm) 2 15 1 5 QH2 at psig QH2 at 1 psig QH2 at 2 psig 2 4 6 8 1 Control Signal Figure 1. Steady State Hydrogen Production by IdaTech FPM 2 vs. Control Signal and Delivery Pressure

The hydrogen production rate varies no more than 2.5 slm over the delivery pressure range of to 2 psig. At the maximum control signal of 1, the hydrogen production rate reaches an average of 23 slm, while at the minimum control signal the production rate averages 5 slm. The production rate is well approximated as a linear function of the control signal. We next investigated the dynamic response of the reformer's hydrogen production rate to sudden step-wise changes in the control signal. Figure 2 shows how the hydrogen production rate changes over time as the control signal steps from to 1 at delivery pressures of and 1 psig. The reformer hydrogen production rate responds quickly to a step change in the control signal. The production rate approaches the steady state value exponentially with a half-life of 2 to 3 seconds. H2 Flow (slm) 25 Control Signal 1 2 8 H2 Flow (slm) 15 1 5 6 4 2 Control Signal psig 1 1 psig -5-2 5 1 15 2 Time (min) Figure 2. Dynamic Response of Hydrogen Production by IdaTech FPM 2 3. System Design SERC selected, procured, and integrated all the air, water, hydrogen, electrical, and control system components for the system. To manage the mismatch between the reformer hydrogen production rate and the fuel cell hydrogen consumption rate, we added a small, low pressure hydrogen ballast tank

between the reformer outlet and the pressure regulator serving the fuel cell and we developed a reformer control algorithm. The ballast tank provides 1 liters of storage at 15 to 25 psig which corresponds to about 6 sl of active storage. The reformer control algorithm adjusted the control signal in response to measured ballast pressure and fuel cell current. Figure 3 shows a schematic of the methanol-hydrogen system with the ballast. Hydrogen Ballast Methanol- Water Mixture Reformer Fuel Cell Figure 3. Schematic Diagram of Methanol-Hydrogen System with Ballast Figure 4 shows a schematic diagram of the power handling system. The SERC 4 cell, 3 cm 2 PEM fuel cell generates to 1 W at 4 to 26 V. A high efficiency step-down dc-to-dc converter drops the voltage to 24 to 28.8 V. All parasitic loads are Battery Fuel Cell DC/DC Converter Inverter AC Load Parasitic Loads Figure 4. Schematic Diagram of Power Handling System

powered from this nominally 24 V bus. The battery is charged or discharged depending on the nominally 24 V bus voltage and serves as an energy ballast in the system. Since the response time of the fuel cell is limited by the response of the air supply system, the battery discharges and helps support the load during the air blower ramp-up period. After the air supply catches up with the power demand on the fuel cell, the battery is recharged. Finally, the ProSine 1 inverter converts 24 Vdc to true sine wave 12 VAC and delivers up to 1 W continuous and 15 W during a surge. The control system handles battery management, reformer control, fuel cell control, cell voltage monitoring, software dependent safety tasks, and data acquisition and recording. SERC developed the LabVIEW based control software in-house. The data acquisition and control system utilizes modular National Instruments Compact FieldPoint hardware for all analog and digital input/output. Compact FieldPoint hardware is suitable for control, measurement, and signal processing in stand-alone embedded real-time systems. The hardware is rugged, capable of withstanding 5 g shocks, 5 g vibrations, and tolerant of 25 to 6 C conditions. An ethernet interface is available for convenient program uploading and data downloading. The system also incorporates a software independent safety circuit that monitors a hydrogen detector and a smoke detector and will immediately shutdown the complete system if a hazardous condition is detected. The completed system is a preproduction prototype or brassboard system built on a small lab bench. In order to facilitate access during system development, subsystem components (e.g., hydrogen supply, water/cooling, power management, etc.) were assembled on panels or shelves that were then installed as a unit on the system bench. Figures 5, 6, and 7 show views of the completed system from the front, side, and rear. In Figure 5, the fuel cell, air blower, methanol storage, methanol reformer, hydrogen ballast, and the power rack with control panel and battery bank are all visible and labeled. In Figure 6, many components of the hydrogen subsystem are shown and labeled, including the methanol storage tank, the hydrogen delivery line from the reformer, the hydrogen pressure transducer, the pressure regulator, the hydrogen supply solenoid valve, the hydrogen delivery line to the fuel cell, the purge solenoid valve, and the hydrogen purge/knockout drum. In Figure 7, the rear of the system is shown and the major components of the water subsystem are labeled, including the water reservoir, the water pump, the deionizing bed, and the water delivery and return lines to and from the fuel cell stack.

Figure 5. Front View of Completed System Showing Fuel Cell, Air Supply, Methanol Storage, Reformer, and Power Rack with Control Panel Figure 6. Side View of Completed System Showing Hydrogen Subsystem

Figure 7. Rear View of Completed System Showing Water/Cooling Subsystem 4. System Testing at SERC After assembly of the system, low level tests were conducted on all analog inputs, analog outputs, digital inputs, and digital outputs to verify their proper operation and calibration. Then the system was tested under constant AC load at 1 W for 9 hrs and 4 W for 72 hrs. Figure 8 shows fuel cell power output, power in and out of the battery, and the dc power input to the inverter over the 9 hrs of testing at 1 W AC load. During the first 35 minutes after system power-up, the reformer goes through a start-up sequence, drawing about 15 Wh from the battery bank and consuming about.5 L of methanol/water fuel mixture from the storage tank. When the reformer is ready, the fuel cell starts and the 1 W AC load is connected. Initially the fuel cell must both support the AC load and recharge the battery bank that was discharged during reformer start-up. The power input to the inverter is always lower than the power output from the fuel cell due to parasitic loads and battery charging. The fuel cell output is stable with no decay over the 9 hours of testing. Figure 9 displays the results of a 72 hr test with a continuous load of 4 W AC. This corresponds to continuous loads associated with cathodic protection of gas and oil

18 Power (Watts) 12 6 FC Watts Battery Watts Inverter Watts -6 2 4 6 8 t (hr) 1 Figure 8. Fuel Cell Output, Battery Input/Output, and Inverter Input Power during 72 hrs of Continuous Operation at 1 W AC 1 Power (Watts) and Average Cell Voltage (mv/cell) 8 6 4 2 FC Watts Inverter Watts Ave mv/cell 1 2 3 4 5 6 7 8 t (hr) Figure 9. Fuel Cell and Inverter Power and Average Cell Voltage at 4 W AC for 72 hr

pipelines and also approximates the daily power consumption for a remote home (e.g., 9.6 kwh/day). In the plot, fuel cell power output, inverter power input, and the average cell voltage for the fuel cell stack are shown for the 72 hr continuous run. The system performed well with minimal decay in average cell voltage. Next the system was tested under dynamic AC load. Figure 1 shows the results of a test with progressively increasing load from to 1 W AC in steps of 1 W over a 6 hr period. The plot shows the fuel cell power output, inverter power input, and the average cell voltage for the fuel cell stack. The system quickly and smoothly responds to each 1 W increase in load while the average cell voltage drops less than 1 mv/cell. Note that the fuel cell output during the first two load steps reflects both the power required to support the load and the power needed to recharge the battery bank which was discharged during reformer startup. 2 1 Power (W at ts) 15 5 ave mv/cell 1 2 3 4 5 6 t (hr) Figure 1. Fuel Cell and Inverter Power and Average Cell Voltage at Progressively Increasing AC Loads from to 1 W in Steps of 1 W 75 FC Watts 1 Inverter Watts 5 25 Average Cell Voltage (mv/cell) Additional dynamic load testing was conducted to record system response to inductive loads and complex dynamic loads cycles that mimic diurnal load patterns observed in residences. In all cases the system performed well. In the inductive load tests, the battery bank delivered power to the inverter during the brief period required for the air blower to ramp up and was then quickly recharged by the fuel cell.

5. System Testing at the Arctic Energy Technology Development Laboratory Following completion of testing at SERC, the system was crated and shipped to Fairbanks for further testing at the Arctic Energy Technology Development Laboratory at the University of Alaska. Figure 11 shows the system ready for testing in Fairbanks. Figure 11. System ready for testing at Arctic Energy Technology Development Laboratory at the University of Alaska, Fairbanks. UAF research engineer Tom Johnson, SERC engineer Mark Rocheleau, and UAF graduate student Tristan Kenny are shown from left to right. The testing set-up at AETDL included a methanol/water fuel flow sensor and a AC power transducer in addition to the sensors incorporated in the fuel cell power system. Figure 12 shows the results of a dynamic load test using 2+ sequential 24 hr load cycles that mimic a 12 kwh/day residential energy usage pattern. Fuel cell power output and the inverter AC power output are shown for the 52 hrs of testing. The fuel cell power output smoothly tracks the step-wise changes in load. Figure 13 shows the methanol/water fuel flow and the AC load for the same run.

16 14 12 FC Watts AC Load Power (Watts) 1 8 6 4 2 1 2 3 4 5 6 t (hr) Figure 12. Fuel Cell Power and AC Load for 48 hr Load Cycle Test at Arctic Energy Technology Development Laboratory 3 12 Fuel Flow (ml/min) AC Load 25 1 Fuel Flow (ml/min) 2 15 1 8 6 4 AC Load (Watts) 5 2 1 2 3 4 5 6 t (hr) Figure 13. Fuel Flow and AC Load for 48 hr Load Cycle

6. System Energy Flow and Efficiency Using the results of the 9 hr constant load test at 1 W and the 48 hr dynamic load tests, we computed for periods of constant load the energy equivalent (LHV) of the fuel flow into the reformer and the hydrogen output from the reformer, the energy output from the fuel cell, the net energy input to the battery, the energy input into parasitic loads, the energy input to the inverter, and the AC energy output from the inverter. Figure 14 shows the corresponding schematic diagram for the system energy flow. Methanol Reformer Fuel Cell Battery Parasitic Loads Inverter AC Load Figure 14. Schematic Diagram of System Energy Flow Based on the results from the 9 hr constant load test at 1 W (i.e., the maximum rated system power output) following reformer start-up, Table 1 summarizes the average energy flow rates at each step in the energy flow diagram, the fraction of the energy provided by the methanol that remains at each step, and the unit efficiencies of the reformer, fuel cell, and inverter. The net input to the battery bank is negligible (i.e., 1.3% of the fuel energy and 3.9% of the fuel cell output). Parasitic loads average

Table 1. Summary of System Energy Flow and Efficiency by Conversion Step Cumulative Conversion Step Energy Flow (Watts) System Efficiency (%) Unit Efficiency (%) Methanol Consumption Rate 484 1.% Reformer Hydrogen Output 2463 6.3% 6.3% Fuel Cell Output 1356 33.2% 55.1% Net Battery Input 53 1.3% Parasitic Loads 185 4.5% Inverter Input 1157 28.3% AC Power Output 1 24.5% 86.4% only 4.5% of the fuel energy (and only 13.6% of the fuel cell output). The average efficiency of the reformer was 6.3%, the fuel cell 55.1%, and the inverter 86.4%.The overall average system efficiency, methanol in to AC power out, was 24.5%, which is good performance in comparison to other reformer/fuel cell power systems. In the 48 hr test with a dynamic load cycle, we conducted a similar analysis for each discrete power level in the load cycle so that we can examine the relationship between system AC load and the overall system efficiency, methanol in to AC power out. Figure 15 presents this relationship. As the system AC load increases from to 1 W, the overall system efficiency increases from % (at zero power out) to about 25% at full load (1 W). Overall system efficiency remains about 2% down to about 65 W load. The solid line in Figure 15 is the fit of the data to the following model: E = E max ( 1 e k P) (1) where: E = overall system efficiency (%) E max = maximum overall system efficiency (%) = 28.7% -1 k = empirical coefficient (W ) =.196 W -1 P = system AC load (W) This model fits well, with a R 2 value of 99.7%.

Methanol to AC Power Efficiency (%) 3 25 2 15 1 5 MeOH to AC Efficiency (%) 2 4 6 8 1 12 AC Power (Watts) Figure 15. Overall System Efficiency vs. AC Power Output 7. Conclusions In this project we: designed and built a methanol-fired proton exchange membrane (PEM) fuel cell power system that can support a dynamic load in excess of 12 kwh per day and deliver up to 1 kw continuous, grid-quality AC power, with peaking to 1.5 kw. developed a control system that provides seamless integration of the methanol reformer and the PEM fuel cell and provides automatic and safe operation. tested the steady state and dynamic performance of the system at the Schatz Energy Research Center in Arcata, California and at the Arctic Energy Technology Development Laboratory at the University of Alaska, Fairbanks, Alaska. observed stable performance of the system in tests up to 72 hrs with negligible drop in average cell voltage. found that the system was able to instantaneously and smoothly respond to stepwise changes in load and to inductive loads. demonstrated an excellent overall system efficiency of 24-25% at full load (1W) and good efficiency of 2% at partial load (65 W). Our next step is to install the system in a residence or small business and monitor its performance in long term operation.