L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Similar documents
Type Z & Ex pz purge and pressurization system

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Assembly. Trunk IN + - S U, I U, I. Spur 1

CYCLOPS Z Purge Indicator

Terminal Boxes in Stainless Steel SLS**.T

CYCLOPS Z Purge Indicator

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

CYCLOPS X Purge Controller XP Version

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Technical Data. Dimensions

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

CYCLOPS X Purge Controller SM Version

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

CYCLOPS Y Purge Indicator

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

Leading the way in hazardous areas Features EATON

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Pneumatic control unit for decentralized automation of ELEMENT process valves

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I Ex-safety switches I

I Ex-safety switches I

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

Type 2REX-A. Oil & Gas / Heavy Industry

Control Device System NEC Series ConSig 8040

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Control Buttons / Switches for Panel Mounting Series 8003

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

I Ex-Safety switches I

ExBin-P Pressure switches 5 Pa Pa

Integrated Control modules

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Solenoid coils VACF Type codes

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Sensor boxes SRBE Key features and product range overview

3/2 and 4/2 directional seat valves with solenoid actuation

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Solutions Ex d IIB+H2, Stainless Steel EJBX*

A good connection. International approvals.

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Spring loaded resistance thermometer

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Operating pressure (bar) kv factor (m 3 /h) *3)

Resistance thermometer Without thermowell Model TR10-H

Position Switches Series 8070/2

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Type Electronic Limit Switch

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

RedBin-P Pressure switches 5 Pa Pa

6mm and 14mm Slim Interface Relay

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Sentronic PLUS 614 Series

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

SCHISCHEK REDBIN-D TRANSMITTER

Series 3730 Electropneumatic Positioner Type

Load and Motor Switches, Load-Break Switches Series 8544

JUMO dtrans p20 DELTA

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Compact Sheet-Steel Light Fittings Series 6114/1

Solutions Ex d IIB+H2, Aluminum and Stainless Steel

Position Switches Series 8060/2

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

INSTRUCTION MANUAL (ATEX / IECEx)

6mm Interface Relays RV8 Series

RedCos-P Pressure sensor 20 Pa Pa

Thermocouple For additional thermowell Model TC10-B

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Surface thermocouple Model TC50

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Position Switches Series 8074/2

Poppet Valves Series. Keeping the World Flowing

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Solenoid Valves Type 3963

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Compact differential pressure switch Models DC, DCC

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

Terminal Boxes Series 8125

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Integrated Control modules

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

Floodlight LED Series 6525

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Linear Luminaire with LED Series EXLUX 6402/2

Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification

Transcription:

Type Z & Ex pz purge and pressurization system Features 100% automatic purge and pressurization system including purging, temperature and leakage control, alarming and system power Third party approvals for Class I, II, Div. 2 and Zone 2/22 Universal mounting RTD inputs for temperature alarm an control Five standard purge programs Application The 5500 series purge/pressurization system consists of the control unit with a user interface in a 316 stainless steel enclosure that works in conjunction with the EPV vents and pneumatic solenoid valves or manual valves form a certified purge and pressurization system for enclosures. The user interface is menu driven and easily guides users through custom programing for their applications. (2) RTD s can be connected to inputs and the user can select temperature ranges for controlling and alarming critical temperatures through a set of contacts and energizing a solenoid valve for displacing air within the enclosure or operate cooling or heating functions. Enclosure pressure and leakage can be monitored. In the event of a loss in pressure a solenoid valve can engage to restore the defined pressure settings and/or alarm for pressure loss. The 5500 series purge and pressurization system has NEC, CEC, ATEX and IECEx third party certifications for Class I, II/Div. 2 and Zone 2/22. External Mount Terminal Block Internal Mount Terminal Block K1 K2 C SV1 L(+) NC N(-) L(+) SV1 N(-) NC K2 C K1 T1 T2 Bypass N(-) N(-) N(-) K1 L(+) N(-) L(+) F1 SV1 F2 Power Terminal Block s F1 SV1 F2 Power L (+) N (-) SV1 K2 K1 N(-) N(-) N(-) L(+) N(-) L(+) K1 Bypass T1 T2 1

General specifications Operating mode fully automatic (FA) Series 5500 Number of volume exchanges 4... 19 Hazardous environment gas or dust Supply Rated voltage U n 90... 264 V AC, 48... 62 Hz ±10 %, single phase 20... 30 V DC Power consumption 100... 240 V AC - 2.3 VA (without digital valve) 20... 30 V DC - 2.5 W (without digital valve) Electrical specifications Fuse rating AC: 2 A DC: 3.15 A Input Input I Temperature, up to 2 RTD's per unit Pt100, 2-wire-connection Input type temperature input Input II 1 Bypass passive contact (switch) Input type mechanical contact Output Output I K1, terminals: K1/N0, K1/N0 enclosure power, (1) SPST 6 A Contact loading 6 A @ 250 V AC, 30 V DC resistive load, 6 A @ 30 V DC Output II K2, terminals: K2(, C, NC) alarm, (1) DPST 3 A Contact loading 3 A @ 250 V AC, 30 V DC resistive load, 3 A @ 30 V DC Output III digital valve, terminals SV (1) SPDT, powered contacts from supply 0.08 A @ 250 VAC 0.5 A @ 30 VDC 3 A Indicators/settings LED indicator Membrane Pad K1: Green - Contact K1 is energized K2: Amber - Contact K2 is energized SV1/encl press.: Blue for safe pressure, Amber for valve on Bypass: Amber when bypass is active PT100 error: Red when fault in PT100 sensor Pneumatic parameters Protective gas supply instrument grade air or inert gas Safe pressure - gas 0.7 mbar (0.3" H 2 O) - dust 1.6 mbar (0.65" H 2 O) Conformity Degree of protection EN 60529 Shock resistance EN 60068-2 Ambient conditions Ambient temperature -20... 40 C (-4... 104 F) at T6-20... 60 C (-4... 140 F) at T4 Relative humidity 5... 90 %, non-condensing Vibration resistance 5... 100 Hz, 1 g, 12 m/s 2, all axes Impact resistance 30 g, 11 ms, all axes Mechanical specifications type High pressure port: 1/8" NPTF Low pressure port: 1/8" NPTF Cable gland Degree of protection Wire size M12 diameter 3-6.5mm M20 diameter 10-14mm RTD/Bypass: (3) M12x1.5 K1, K2, SV1: 'P_C' (3) M20x1.5 Type 4X, IP66 2

Material Mass Dimensions Data for application in connection with Ex-areas EC-Type Examination Certificate Group, category, type of protection, temperature class Housing: 316 stainless steel Cable Gland: 316 stainless steel or Nickel Plated Brass Pressure Ports: 316 stainless steel Membrane Pad: Autotex F200XE O-ring: EPDM approx. 2.7 kg (6 lb) 165 x 124 x 90 mm (6.5 x 4.9 x 3.5 in) external II 3 G Ex ic na nc [ic pz IIC Gc] IIC T4 [Gc] (-20 C to 60 C) II 3 G Ex ic na nc [ic pz IIC Gc] IIC T6 [Gc] (-20 C to 40 C) II 3 D Ex ic tc [ic pd IIIC Dc] IIIB T80 C Dc (-20 C to 60 C) II 3 D Ex ic tc [ic pd IIIC Dc] IIIB T60 C Dc (-20 C to 40 C) internal II 3 G Ex ic na nc [ic pz IIC] IIC T4 [Gc] (-20 C to 60 C) II 3 G Ex ic na nc [ic pz IIC] IIC T6 [Gc] (-20 C to 40 C) II 3 D Ex ic tc [ic pd IIIC Dc] IIIC T80 C Dc (-20 C to 60 C) II 3 D Ex ic tc [ic pd IIIC Dc] IIIC T60 C Dc (-20 C to 40 C) Directive conformity Directive 94/9/EC EN 60079-0:2012+A11:2013, EN 60079-2:2007, EN 60079-11:2012, EN 60079-15:2010, EN 60079-31:2009, EN 61241-4:2006 International approvals UL approval culus Class I Division 2 Group A-D T4 (-20 C to 60 C) Class I Division 2 Group A-D T6 (-20 C to 40 C) Class II Division 2 Group F+G T4 (-20 C to 60 C) Class II Division 2 Group F+G T6 (-20 C to 40 C) IECEx approval Ex ic na nc [ic pz IIC Gc] IIC T4 Gc (-20 C to 60 C) Ex ic na nc [ic pz IIC Gc] IIC T6 Gc (-20 C to 40 C) Ex ic tc [ic pd IIIC Dc] IIIB T80 C Dc (-20 C to 60 C) External version Ex ic tc [ic pd IIIC Dc] IIIB T60 C Dc (-20 C to 40 C) External version Ex ic tc [ic pd IIIC Dc] IIIC T80 C Dc (-20 C to 60 C) Internal version Ex ic tc [ic pd IIIC Dc] IIIC T60 C Dc (-20 C to 40 C) Internal version General information Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperlfuchs.com. Accessories 5500-MAN-CDUL-* 5500-MAN-CD01-* 5500-MAN-EX01-* EPV-5500 Vent System 3

Dimensions - External Mounting 21 40 70 99 106 124 90 90 78 41 58 169 28 23 55 39.5 62 1 2 215 165 1 Low pressure port (atmostpheric pressure) 2 High pressure port (enclosure pressure) Dimensions - Internal Mounting 106 99 70 40 21 62 39.5 55 23 124 90 58 16 ø 6.4 x 3 90 215 168 110 28 169 1 Low pressure port (atmostpheric pressure) 2 High pressure port (enclosure pressure) 60.7 1 2 31 60 4

Type code/model number 5 5 0 0 - S S - I - V A C - P S C - L S C Housing Material SS 316 stainless steel Voltage requirement VAC 100 to 240 VAC VDC 20 to 30 VDC Mounting Configuration E External mounting I Internal Mounting Wiring entrance for power connection PSC (3) M20 stainless power cable gland PBC (3) M20 Nickel plated power cable gland PSH (3) ½"NPTF Stainless steel conduit entrance P No fittings or cable gland Wiring entrance for low voltage connection LSC (3) M12 Stainless low power cable glands LBC (3) M12 Nickel plated low power cable glands L No cable glands Type of System Type Z & Ex pz, Zone 2 or 22, NEC Class I or II / Division 2 5