! WARNING I.L D WARNING GENERAL INFORMATION

Similar documents
Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Installation Instructions for the 14" Walking Beam Interlock for L-Frame and MDL-Frame Series C Circuit Breakers and Molded Case Switches

Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches

I.L. 29C184A File WARNING

I.L. 29C121A WARNING 1. INTRODUCTION. Maximum Freq. Maximum Dielectric Voltage Current Withstand (V) (A) Voltage (V)

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Cutler-Hammer. Installation Instructions for the ND OPTIM 550 PowerNet and/or Zone Interlock Accessories (ICK 550N, ZGK550N, ZGPK550N) I.L.

CCP2-FLR1-21_ flange-rod operating mechanism

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

A WARNING. Installation Instructions for KD, HKD, KDC, CKD, CHKD Circuit Breakers I.L. 29C092C

Installation Instructions for R-Frame Circuit Breakers and Molded Case Switches

Two-way cable interlock kit for Magnum fixed circuit breakers

a WARNING Allen-Bradley Parts K-Frame Circuit Breaker Instruction Leaflet for Alarm Switch and Alarm /Auxiliary Switch Combination Bul.

Two-way cable interlock kit for Magnum drawout circuit breakers

Installation Instructions for TMQV Circuit Breakers and Molded Case Switches

Installation Instructions for NW, HNW, and NWC Circuit Breakers and N-frame Series C Molded Case Switches

O & M Manual for the EATON Generator Ready Loadcenter

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

3-way multi-family drawout cable interlock kit - type 32 - RF

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

Digitrip Retrofit System for BBC LKD 8 Breakers

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

Digitrip Retrofit System for Siemens-Allis RLX-1600 Breakers

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

Instructions for using Functional Test Kit on Digitrip 520 and 1150 family of Power Circuit Breaker Trip Units and Series G and FD MCCB Trip Units

SPX9000 FR10 FR12 Adjustable Frequency Drives

Digitrip Retrofit System for Allis-Chalmers G-25 Breakers

Advanced Test Equipment Rentals ATEC (2832)

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES

RotoTract Remote Racking Operating Manual

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

CM52 Network Protector with Arc Flash Reduction Module

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

Installation Instructions for Series C F-Frame 310+ Electronic Circuit Breaker Types FDE, HFDE, FDCE

Installation Instructions

Dry-Type Transformers Mini-Power Centers

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

Installation Instructions For Motor Control Center (MCC) Units

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers

Preferred Cutout, Disconnect Enclosure, Type 12

Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Powers TM Controls EA 338 Electronic Actuator

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

INSTALLATION INSTRUCTIONS

Cutler-Hammer I.B. ATS-RT03. Instructions for Cutler-Hammer Residential Automatic Transfer Switch

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

Installation Instructions

When the ACB is CLOSED and in the connected position the draw-out handle cannot be inserted.

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

Instruction Sheet EWR SERIES EWR WALL CABINET R

Application Description

Digitrip RMS and Digitrip OPTIM Trip Units Used with R-Frame Circuit Breakers

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

INSTALLATION GUIDE TCP RCKM-01

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

CENTERLINE 2100 Motor Control Centers 600A, 800A, and 1200A Bolted Pressure Contact Switch

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

www. ElectricalPartManuals. com Digitrip Retrofit System for the Westinghouse DA-50 IL 33-DAC-2 WARNING

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

EN4DSC Disconnect Enclosures - NEMA 4 ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex, Square D

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

N-frame Circuit Breaker

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

www. ElectricalPartManuals. com

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

DISC BRAKE/DUAL MASTER CYLINDER CONVERSION. Tools, Equipment and Supplies Needed:

Installation Instructions for Series C F-Frame 310+ Electronic Circuit Breaker Types FDE, HFDE, FDCE

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Installation Instructions

Effective November 2016 Supersedes September 1998 (S )

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

Introduction. Features. Intelligent Technologies Motor Control Center Structures

INSTALLATION INSTRUCTIONS FOR DSP9600/9100 WHEEL BALANCER

Standard Product Low Profile Type 12 One-Door Disconnect Enclosures

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Transcription:

C Instructions for Drilling and Assembling Flex Shaft TM Handle Mechanism for L, M, MDL, N, and R-Frame Series C Circuit Breakers, Molded Case Switches, and HMCP s! WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENER- GIZED. SEVERE PERSONAL INJURY, DEATH, OR SUBSTANTIAL PROPERTY DAMAGE CAN RESULT FROM CONTACT WITH ENERGIZED EQUIPMENT. ALWAYS VERIFY THAT NO VOLTAGE IS PRESENT BEFORE PROCEEDING WITH THE TASK, AND ALWAYS FOLLOW GENERALLY ACCEPTED SAFETY PROCEDURES. CUTLER-HAMMER IS NOT LIABLE FOR THE MISAPPLICATION OR MISINSTALLATION OF ITS PRODUCTS. The user is cautioned to observe all recommendations, warnings and cautions relating to the safety of personnel and equipment as well as all general local health and safety laws, codes and procedures. The recommendations and information contained herein are based on Cutler-Hammer's experience and judgment, but should not be considered to be all-inclusive or covering every application or circumstance which may arise. If any questions arise, contact Cutler-Hammer for further information or instructions. GENERAL INFORMATION The Shaft handle mechanism provides a means of externally operating the circuit breaker and can be applied to enclosures of varying heights and depths. The handle can be used with NEMA 1, 3R, and 12 enclosure applications, plus NEMA 4 and 4x applications, depending on the accessory components selected. An operating handle, flexible shaft, and mechanism are required for standard applcation. Three lengths of shafts are available for use with the range of depths of various enclosures (4, 5, and 6 ). When selecting the length of the Flexible Shaft, ensure Minimum Bending Radius of 5 inches is maintained to operate properly. The flex shaft assembly is Underwriters Laboratories, Inc. listed under UL File E64983.! WARNING WHEN INSTALLING A NEW HANDLE MECHANISM, OR A NEW CIRCUIT BREAKER AND HANDLE MECHANISM IN AN EXISTING ELECTRICAL SYS- TEM, MAKE SURE THERE IS NO VOLTAGE PRE- SENT WHERE WORK IS TO BE PERFORMED. SPE- CIAL ATTENTION SHOULD BE PAID TO REVERSE FEED APPLICATIONS TO ENSURE NO VOLTAGE IS PRESENT. THE VOLTAGE IN ENERGIZED EQUIP- MENT CAN CAUSE DEATH OR SEVERE PERSONAL INJURY. Figure 1-1 Pivot Bracket and Outer Handle Mechanism Assembly Effective November 2007 Supersedes I.L. 15606C dated February 2001

Page 2 Figure 1-2 LD, MDL, ND, RD Mechanism Assembly

Page 3 INSTALLATION 1. Remove the two 1/4-20 x 5/8" screws and lockwashers from the outer handle mechanism. Place each screw and lockwasher though the pivot bracket assembly Thread the retaining washers enclosed in the parts kit onto the 1/4-20 x 5/8" screws. See Figure 1-1. 2. Connect the actuator link from the outer handle mechanism on the pivot bracket assembly Mount the pivot bracket assembly to the enclosure and outer handle mechanism by securing the mounting hardware. Attach the E-Ring supplied in the parts kit to the actuator link. See Figure 1-1. 3. Drill and tap the mounting holes for the circuit breaker. See breaker frame instruction leaflet for the drilling pattern. Note: Be certain that there is a 5 inch minimum clearance between the load end of the breaker and wall of the enclosure for the flex shaft. 4. Mount breaker's Line end to enclosure using the mounting hardware supplied in the hardware kit. 5. Attach the base plate and mounting hardware to the load end of the circuit breaker per the following breaker frames: LD: Attach the base plate and Load end of the breaker to enclosure using the 1/4-20x4.75" screws and lockwashers enclosed. See Figure 1-2 for illustration. M: Attach the Load end of the breaker to the enclosure using hardware frame parts kit. Attach the base plate to the Load end cover on the (M) type breaker. The load end cover screws are replaced with the (2) 10-32x2" screws and lockwashers enclosed. (Not shown in Figure 1-2). MDL: Attach the load end of the breaker to the enclosure using hardware from the hardware kit. Attach the base plate to the load end cover of the breaker. The load end cover screws are replaced with the (2) #8-32x2.25" screws, #8 lockwashers, and mounting sleeves enclosed. See Figure 1-2 for illustration. ND: Attach the Load end of the breaker to the enclosure using hardware from the hardware kit. Attach the base plate to the circuit breaker using the 1/4-2Ox3.5" screws and 1/4" lockwashers enclosed in the parts kit at the load end of the breaker after removing the (2) load cover screws located between the trip unit and the two load end mounting holes. See Figure 1-2 for illustration. RD: Attach the Load end of the breaker to the enclosure using the hardware from the hardware kit. Attach the base plate to the circuit breaker using the 1/4-20x3.75" screws and 1/4" lockwashers enclosed in the parts kit at the load end of the breaker. See Figure 1-2 for illustration. Note: Prior to Dec. 1994: The Breaker mounting hardware for Line end and Load end mounting (except LD) were in the appropriate breaker frame mounting hardware kit. The mounting hardware is now included in the hardware parts enclosed. 6. Place the outer handle mechanism in the full ON position and the circuit breaker in the ON position. You must Release Cover interlock to move handle to ON position. Place the handle extension assembly onto the breaker handle and secure as shown on Figure 1-2. Note: LD and MD use clamp type assembly: ND and RD use a through bolt for handle attachment from the hardware kit. 7. Locate bulk head nuts of the flexible shaft over the groove of the base plate and tighten. 8. Actuate the outer handle positions (ON, OFF, RESET). If minor adjustments are necessary, refer to the following adjustment checklist and Figure 1-2. Install appropriate door hardware (supplied); as referenced on Figure 1-3. ADJUSTMENT CHECKLIST Situation: Breaker turns ON and OFF, but will not RESET when tripped. Adjustment: Loosen the 1/4-28 adjusting nut that is closest to the black cap and turn towards the cap about 1.5-2 turns. Retighten the adjusting nut that is on the end of the shaft to the handle extension and inner adjusting nut. Recheck for the ON, OFF and RESET position. If not successful, repeat procedure. If still not successful, and the adjusting nut is bottomed out onto the shaft, loosen the bulk head nuts, and shift the cable towards the Load end of the breaker. Re-tighten the bulk head nuts. Recheck for the ON, OFF and RESET position. If not successful, repeat the beginning steps.

Page 4 Situation: Breaker resets after tripping, but does not turn ON. Adjustment: Loosen the 1/4-28 adjusting nut that is located on the end of the shaft and turn towards the end of the shaft about 1/5-2 turns. Re-tighten the adjusting nut that is closest to the black cap to the handle extension and the outing adjusting nut. Re-check for the ON, OFF and RESET position. If not successful, and the adjusting nut on the end of the shaft is two threads from the end, loosen the bulk head nuts, and shift the cable towards the line end of the breaker. Re-tighten the bulk head nuts. Re-check for the ON, OFF and RESET position. If not successful, repeat the beginning steps. If any other adjustment problems should arise, contact your local Cutler-Hammer representative.

Page 5 Handle Mechanisms (Dimensions in Inches) Outline and Drilling Plans For Enclosure Door Interlock Assembly Figure 1-3 Flange Drilling Plan For Handle and Interlock Blade Mounting Dimensions

Page 6

Page 7

Page 8 Eaton Corporation Eaton Electrical Business unit 1000 Cherrington Parkway Moon Township, PA USA www.eatonelectrical.com 2001 Eaton Corporation All rights Reserved Printed in U.S.A Style 6648C76H05 (TQC).