FPGA Instruments Resource Usage

Similar documents
Marwan Adas December 6, 2011

Local Memory Bus (LMB) V10 (v1.00a)

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Energy Briefing: US Petroleum Products Supplied

Learn to Design with Stratix III FPGAs Programmable Power Technology and Selectable Core Voltage

Up and Down Months of the Stock Market

Glendale Water & Power Smart Grid Project

Energy Briefing: US Petroleum Weekly Inventories

RAM-Type Interface for Embedded User Flash Memory

Energy Briefing: US Gasoline Weekly

RECHARGE STATION OPERATION MANUAL. Version

EXECUTIVE SUMMARY Revenue Estimating Conference for Article V Fees & Transfers July 20, 2016

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

2018 CALENDAR DASHBOARD

Overview Python Scripting in Abaqus Specialized Postprocessing Advanced Topics Introduction to Python and Scripting in Abaqus

Field Programmable Gate Arrays a Case Study

Network Installation. July 2008 CONTENTS

CENTRAL ISSUING OFFICE (CIO) PROCEDURE FOR THE ACCEPTANCE OF NEW LOCAL ISSUING OFFICES

Chapter 11. Using MAX II User Flash Memory for Data Storage in Manufacturing Flow

Introduction to Abaqus Scripting. Abaqus 2018

Fiberglass & Steel Exterior Doors

US Economic Briefing: Regional Business Surveys

Automotive Powertrain Assembly Analysis with Abaqus

XC95288 In-System Programmable CPLD

NJ Solar Market Update As of 6/30/15

Battery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions

Intel Enpirion Power Solutions Tape and Reel, and Tray Packaging Information

EXECUTIVE SUMMARY ATLANTIC SALMON NO 03/06

How to get started. with. Kongsberg XP Auto systems. Serial number: Please Read This First

Security. Hardware Specifications. Editor: Stephen Satchell. Version Security Hardware Specification version i Copyright 2012 INE, Inc.

Advanced Abaqus Scripting. Abaqus 2018

Installing the Throttle Commander Ford F250 F550 Super Duty

Past Due. Account Charges. Contract Charges Security Deposit Due - Jun 09, , Customer Service. Jun 19, PAST DUE $1,693.

Market Briefing: S&P 500 Bull & Bear Markets & Corrections

Tracey Ma, Patrick Byrne & Yoassry Elzohairy

Balance from your previous bill $0.00 Meter # Basic Charge: 17 $ /day 3.23* Energy charge:¹ 2

Sprinkler System Waiver Application Packet

Deep Learning Will Make Truly Self-Driving Cars a Reality

Spare Allen-Bradle. Battery Replacement. Installation Instructions. About This Publication. Catalog Number 2711P-RY2032

Quant Briefing: Revenues, Earnings, & Margins

Quant Briefing: Revenues, Earnings, & Margins

STATISTICS BOTSWANA ELECTRICITY GENERATION & DISTRIBUTION 2016/2 STATS BRIEF, FIRST QUARTER Copyrights Statistics Botswana 2016

National Routing Number Administration p-ani Activity and Projected Exhaust Report

Automotive NVH with Abaqus. About this Course

ETSI EN V1.2.1 ( ) Harmonized European Standard (Telecommunications series)

FUSION MINI. Fusion Mini Light Bar Instruction Manual V.1. Model # FN-6116, FN-6116D. Distributed By:

Parts Catalog Issued: Feb 5, Invacare I-Lift. Patient Transport Lift

Installation. Active Valve Control Control of Exhaust Valves MB W205 C43 AMG C63 (S) AMG

Automotive NVH with Abaqus. Abaqus 2018

DART Charger Product Description, Information and Specification

ANCR CRU Statistics February 2007 to December 2007

State of the Industry: U.S. Classes 3-8 Used Trucks

Italy Retail, Q Investment still in slow motion, but interest in developments grows

Pneumatic Control Box Manual I630-E-01 1

ISO 1185 INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

THALES AVIONICS ELECTRICAL SYSTEMS TECHNICAL PUBLICATIONS HELICO

7 Habits of Highly Effec3ve Product Development

US Economic Briefing: Regional Business Surveys

FENIEX ROCKER PANEL Series MODEL # D-11971

CareGuard by Invacare

Contents. Software. CALIBRATION PROCEDURE NI PXIe Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module. ni.com/manuals

LASER LEVEL KIT INTRODUCTION REVISION HISTORY UNDERSTANDING THIS MANUAL COPYRIGHT NOTICE CONTENTS...

ARM. series SIGNUM SYSTEMS CORPORATION. ARM Board Setup. User Guide

NJ Solar Market Update

Analyst s Handbook: Health Care

CHARLES RIVER POLLUTION CONTROL DISTRICT. Requirements for Septage Receiving

ISMI 450mm Program Interoperability Test Bed (ITB)

To: All battery recyclers and battery collection points and related associations.

Spectralink 6000 Portfolio. Outdoor Base Station. Installation Guide. For Spectralink 6000 System

SP-575V Tailgate Spreader

Affected vehicles are now on a Stop Sale and will show open in Warranty Vehicle Inquiry, AIR, or ISPA Next. POIS will be updated overnight.

NEWS Release. U.S. Manufacturing Technology Orders. Year-to-date U.S. manufacturing technology orders up 4.1% over 2011

COBRA Model # - D X, D X, D-20109, D-20209, D-20409, D20609, D-20809, D-21015, D-20119, D Cobra Series- Instruction Manual V.

Global Index Briefing: MSCI Sectors Forward P/Es Selected Countries & Regions

FUSION Model # - FN-XXXX, *See website for Part # Fusion Innerbar. Instruction Manual V2.0

Installation Instructions

November 2017 Customer Switching Report for the Electricity and Gas Retail Markets

Dassault Systèmes Automotive Powertrain Assembly Analysis with Abaqus

Equa-Flex Tandem and Triple OEM INSTALLATION MANUAL

PowerFlex 7000 AC Drive with Direct-to-Drive Technology. Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions

Experian Automotive Quarterly Briefing

IGNITION INTERLOCK LIMITED LICENSE THE LAW Frequently Asked Questions

Oracle Utilities Customer Care and Billing Release Utility Reference Model Process Customer Request for Net Metering

Research and Statistics Department FOR RELEASE 8:50 A.M. Thursday, July 26, All items

IOWA MOLD TOOLING CO., INC. BOX 189, GARNER, IA TEL: IMT PART NUMBER

Experian Automotive Quarterly Briefing

Road Armor Triple Axle Equalizer by Trailair

SSC Sensor Replacement Board for the SSC Evaluation Kit. Features. Benefits

Industry Overview. Powersports Market Update

Hydraulic Supply and Return Piping

Daily Trends and Source Apportionment of Ultrafine Particulate Mass (PM 0.1 ) Over an Annual Cycle in a Typical California City

Relay Retrofit Program Cutting Tool Safety Guide

Tensioning Winder 30. CS9160 Eco Solvent Printers

Mark Shamley Managing Director Elster Kent Metering South Africa

Chart Collection for Morning Briefing

Full Length Bed Rail - Model G29

Research and Statistics Department FOR RELEASE 8:50 A.M. Tuesday, December 25, 2018

Fusion GPL 49 Instruction Manual

Transcription:

Summary This quick reference provides detailed information about resource usage of all presynthesized Instruments cores. Core Reference CR0134 (v1.10) July 17, 2008 Instruments The available Instruments cores are listed as follows: CLKGEN FRQCNT2 IOB_1X8 IOB_1X16 IOB_2X8 IOB_2X16 IOB_4X8 IOB_4X16 LAX_1K8 LAX_1K16 LAX_2K8 LAX_2K16 LAX_4K8 LAX_4K16 LAX_8 LAX_16 TERMINAL CR0134 (v1.10) July 17, 2008 1

CLKGEN Frequency Generator Cyclone 261 191 224 8 Cyclone2 205 203 226 15 Cyclone3 224 137 224 Stratix 261 191 224 15 Stratix2 204 202 224 15 StratixGX 260 191 224 15 Max2 263 191 226 4 Max3000a 286 286 224 Max7000b 286 286 224 Max7000ae 286 286 224 Max7000s 298 298 224 Spartan2 346 228 225 Spartan2E 346 228 225 Spartan3 364 236 225 Spartan3A 559 442 225 Spartan3E 571 448 225 Spartan3L 559 442 225 Virtex 346 228 225 Virtex2 346 230 225 Virtex2p 346 230 225 VirtexE 346 228 225 Virtex4 589 461 225 Virtex5 193 193 193 CoolRunner2 267 224 CoolRunnerXpla3 756 224 Xc9500 282 224 Xc9500XL 260 224 Xc9500XV 283 224 ProAsicPlus 803 ProAsic3 643 ProAsic3E 650 EC 366 260 224 ECP 366 260 224 ECP2 398 257 224 ECP2M 398 257 224 MACHXO 408 276 XP 394 256 224 SC 332 256 224 2 CR0134 (v1.10) July 17, 2008

FRQCNT2 Frequency Counter Cyclone 591 424 544 8 Cyclone2 676 417 415 11 Stratix 591 424 544 9 Stratix2 411 408 412 11 StratixGX 591 424 544 9 Max2 585 418 415 4 Spartan2 696 322 546 Spartan2E 696 322 545 Spartan3 690 378 413 Spartan3A 1085 782 413 Spartan3E 1108 793 414 Spartan3L 1085 782 413 Virtex 696 322 546 Virtex2 696 325 546 Virtex2p 696 325 546 VirtexE 696 322 546 Virtex4 1102 792 414 Virtex5 349 349 349 CoolRunner2 2686 CoolRunnerXpla3 1536 ProAsicPlus 1589 ProAsic3 1368 ProAsic3E 1382 EC 1012 577 481 ECP 1012 577 481 ECP2 1082 643 483 ECP2M 1082 643 483 MACHXO 952 515 XP 952 510 483 SC 1064 573 547 CR0134 (v1.10) July 17, 2008 3

IOB_1X8 1 Ch x 8 Bit Digital IO Cyclone 93 55 77 2 Cyclone2 54 53 78 2 Cyclone3 77 35 77 Stratix 93 55 77 2 Stratix2 48 47 77 2 StratixGX 93 55 77 2 Max2 95 54 78 2 Max3000a 84 84 77 Max7000b 84 84 77 Max7000ae 84 84 77 Max7000s 84 84 77 Spartan2 110 93 70 Spartan2E 110 93 70 Spartan3 106 90 70 Spartan3A 166 149 70 Spartan3E 170 153 70 Spartan3L 166 149 70 Virtex 110 93 70 Virtex2 110 93 70 Virtex2p 110 93 70 VirtexE 110 93 70 Virtex4 192 160 78 Virtex5 8 8 8 CoolRunner2 78 77 CoolRunnerXpla3 78 77 Xc9500 78 77 Xc9500XL 78 77 Xc9500XV 78 77 ProAsicPlus 250 ProAsic3 189 ProAsic3E 190 EC 118 84 77 ECP 118 84 77 ECP2 114 79 77 ECP2M 114 79 77 MACHXO 118 80 XP 116 79 77 SC 112 79 77 4 CR0134 (v1.10) July 17, 2008

IOB_1X16 1 Ch x 16 Bit Digital IO Cyclone 109 63 93 2 Cyclone2 62 61 94 2 Cyclone3 93 35 93 Stratix 108 62 93 2 Stratix2 56 55 93 2 StratixGX 108 62 93 2 Max2 110 62 94 2 Max3000a 100 100 93 Max7000b 100 100 93 Max7000ae 100 100 93 Max7000s 100 100 93 Spartan2 128 111 78 Spartan2E 128 111 78 Spartan3 122 106 78 Spartan3A 182 165 78 Spartan3E 184 167 78 Spartan3L 182 165 78 Virtex 128 111 78 Virtex2 128 111 78 Virtex2p 128 111 78 VirtexE 128 111 78 Virtex4 232 184 94 Virtex5 16 16 16 CoolRunner2 94 93 CoolRunnerXpla3 94 93 Xc9500 94 93 Xc9500XL 94 93 Xc9500XV 94 93 ProAsicPlus 290 ProAsic3 214 ProAsic3E 217 EC 142 92 93 ECP 142 92 93 ECP2 138 87 93 ECP2M 138 87 93 MACHXO 138 88 XP 140 87 93 SC 136 87 93 CR0134 (v1.10) July 17, 2008 5

IOB_2X8 2 Ch x 8 Bit Digital IO Cyclone 112 67 93 2 Cyclone2 65 64 94 2 Cyclone3 93 38 93 Stratix 112 67 93 2 Stratix2 59 58 93 2 StratixGX 112 67 93 2 Max2 111 65 94 2 Max3000a 103 103 93 Max7000b 103 103 93 Max7000ae 103 103 93 Max7000s 103 103 93 Spartan2 128 112 78 Spartan2E 128 112 78 Spartan3 124 108 78 Spartan3A 184 167 78 Spartan3E 188 171 78 Spartan3L 184 167 78 Virtex 128 112 78 Virtex2 130 114 78 Virtex2p 130 114 78 VirtexE 128 112 78 Virtex4 234 186 94 Virtex5 16 16 16 CoolRunner2 94 93 CoolRunnerXpla3 94 93 Xc9500 94 93 Xc9500XL 94 93 Xc9500XV 94 93 ProAsicPlus 296 ProAsic3 216 ProAsic3E 218 EC 146 95 93 ECP 146 95 93 ECP2 144 89 93 ECP2M 144 89 93 MACHXO 144 90 XP 144 89 93 SC 138 89 93 6 CR0134 (v1.10) July 17, 2008

IOB_2X16 2 Ch x 16 Bit Digital IO Cyclone 143 83 125 2 Cyclone2 82 81 126 2 Cyclone3 125 38 125 Stratix 143 83 125 2 Stratix2 76 75 125 2 StratixGX 143 83 125 2 Max2 143 81 126 2 Max3000a 135 135 125 Max7000b 135 135 125 Max7000ae 135 135 125 Max7000s 135 135 125 Spartan2 162 145 94 Spartan2E 162 145 94 Spartan3 160 142 94 Spartan3A 216 199 94 Spartan3E 220 203 94 Spartan3L 216 199 94 Virtex 162 145 94 Virtex2 164 147 94 Virtex2p 164 147 94 VirtexE 162 145 94 Virtex4 316 236 126 Virtex5 32 32 32 CoolRunner2 126 125 CoolRunnerXpla3 126 125 Xc9500 126 125 Xc9500XL 126 125 Xc9500XV 126 125 ProAsicPlus 376 ProAsic3 266 ProAsic3E 271 EC 194 111 125 ECP 194 111 125 ECP2 192 105 125 ECP2M 192 105 125 MACHXO 194 108 XP 192 105 125 SC 186 105 125 CR0134 (v1.10) July 17, 2008 7

IOB_4X8 4 Ch x 8 Bit Digital IO Cyclone 147 88 125 2 Cyclone2 88 87 126 2 Cyclone3 125 42 125 Stratix 147 88 125 2 Stratix2 83 82 125 2 StratixGX 147 88 125 2 Max2 149 88 126 2 Max3000a 139 139 125 Max7000b 139 139 125 Max7000ae 139 139 125 Max7000s 139 139 125 Spartan2 164 148 94 Spartan2E 164 148 94 Spartan3 162 145 94 Spartan3A 222 204 94 Spartan3E 224 208 94 Spartan3L 222 204 94 Virtex 164 148 94 Virtex2 164 148 94 Virtex2p 164 148 94 VirtexE 164 148 94 Virtex4 320 239 126 Virtex5 32 32 32 CoolRunner2 126 125 CoolRunnerXpla3 126 125 Xc9500 126 125 Xc9500XL 126 125 Xc9500XV 126 125 ProAsicPlus 384 ProAsic3 275 ProAsic3E 277 EC 208 119 125 ECP 208 119 125 ECP2 202 110 125 ECP2M 202 110 125 MACHXO 200 112 XP 202 110 125 SC 194 110 125 8 CR0134 (v1.10) July 17, 2008

IOB_4X16 4 Ch x 16 Bit Digital IO Cyclone 212 121 189 2 Cyclone2 120 119 190 2 Cyclone3 189 42 189 Stratix 212 121 189 2 Stratix2 117 116 189 2 StratixGX 212 121 189 2 Max2 223 120 190 1 Max3000a 203 203 189 Max7000b 203 203 189 Max7000ae 203 203 189 Max7000s 203 203 189 Spartan2 240 214 127 Spartan2E 240 214 126 Spartan3 236 210 126 Spartan3A 298 272 126 Spartan3E 295 274 127 Spartan3L 296 268 126 Virtex 240 214 127 Virtex2 234 214 127 Virtex2p 234 214 127 VirtexE 240 214 127 Virtex4 489 337 191 Virtex5 64 64 64 CoolRunner2 190 189 CoolRunnerXpla3 190 189 Xc9500 190 189 Xc9500XL 190 189 Xc9500XV 190 189 ProAsicPlus 544 ProAsic3 375 ProAsic3E 385 EC 310 151 195 ECP 310 151 195 ECP2 306 142 197 ECP2M 306 142 197 MACHXO 308 147 XP 306 144 197 SC 300 145 197 CR0134 (v1.10) July 17, 2008 9

LAX_1K8 Logic Analyzer 1K8 Cyclone 609 535 330 2 4 Cyclone2 530 530 332 2 4 Cyclone3 421 421 353 Stratix 613 538 330 2 4 Stratix2 462 463 330 2 4 StratixGX 614 539 330 2 4 Spartan2 677 512 321 2 1 Spartan2E 691 512 320 2 1 Spartan3 661 505 320 1 1 Spartan3A 1055 877 347 Spartan3E 1186 1021 348 1 Spartan3L 1025 855 343 Virtex 681 514 321 2 1 Virtex2 673 511 321 1 1 Virtex2p 673 512 321 1 1 VirtexE 681 512 321 2 1 Virtex5 11 11 11 ProAsicPlus 1816 4 ProAsic3 1679 2 ProAsic3E 1708 2 EC 900 763 344 1 ECP 900 763 344 1 MACHXO 932 792 1 XP 980 793 363 1 SC 904 756 368 1 10 CR0134 (v1.10) July 17, 2008

LAX_1K16 Logic Analyzer 1K16 Cyclone 765 653 426 4 4 Cyclone2 657 657 428 4 4 Cyclone3 482 482 457 Stratix 768 655 426 4 4 Stratix2 573 574 426 4 4 StratixGX 769 656 426 4 4 Spartan2 837 629 410 4 1 Spartan2E 843 633 409 4 1 Spartan3 831 627 408 1 1 Spartan3A 1314 1079 444 Spartan3E 1479 1251 445 1 Spartan3L 1290 1068 440 Virtex 847 634 410 4 1 Virtex2 845 633 410 1 1 Virtex2p 845 633 410 1 1 VirtexE 837 626 410 4 1 Virtex4 1244 1032 428 1 Virtex5 19 19 19 ProAsicPlus 2360 8 ProAsic3 2204 4 ProAsic3E 2246 4 EC 1146 961 449 2 ECP 1146 961 449 2 MACHXO 1190 1023 2 XP 1230 1024 466 2 SC 1154 956 480 1 CR0134 (v1.10) July 17, 2008 11

LAX_2K8 Logic Analyzer 2K8 Cyclone 628 555 336 4 4 Cyclone2 548 548 338 4 4 Cyclone3 413 413 359 Stratix 625 551 336 4 4 Stratix2 473 474 336 4 4 StratixGX 626 552 336 4 4 Spartan2 685 526 327 4 1 Spartan2E 701 524 326 4 1 Spartan3 667 511 326 1 1 Spartan3A 1054 880 354 Spartan3E 1177 1012 355 1 Spartan3L 1040 869 350 Virtex 679 518 327 4 1 Virtex2 681 522 327 1 1 Virtex2p 681 522 327 1 1 VirtexE 681 524 327 4 1 Virtex4 992 838 338 1 Virtex5 11 11 11 ProAsicPlus 1878 8 ProAsic3 1713 4 ProAsic3E 1740 4 EC 926 782 350 2 ECP 926 782 350 2 MACHXO 952 823 2 XP 1002 824 371 2 SC 914 776 375 1 12 CR0134 (v1.10) July 17, 2008

LAX_2K16 Logic Analyzer 2K16 Cyclone 767 654 432 8 4 Cyclone2 665 665 434 8 4 Cyclone3 494 494 463 Stratix 813 701 432 8 4 Stratix2 594 595 432 8 4 StratixGX 814 702 432 8 4 Spartan2 857 650 416 8 1 Spartan2E 855 648 416 8 1 Spartan3 853 639 414 2 1 Spartan3A 1310 1082 450 Spartan3E 1387 1161 451 2 Spartan3L 1316 1086 446 Virtex 859 652 416 8 1 Virtex2 877 658 416 2 1 Virtex2p 877 658 416 2 1 VirtexE 857 649 416 8 1 Virtex4 1272 1056 434 2 Virtex5 19 19 19 ProAsicPlus 2437 16 ProAsic3 2251 8 ProAsic3E 2296 8 EC 1178 981 456 4 ECP 1178 981 456 4 MACHXO 1224 1051 4 XP 1274 1052 476 4 SC 1174 981 484 2 CR0134 (v1.10) July 17, 2008 13

LAX_4K8 Logic Analyzer 4K8 Cyclone 627 552 342 8 4 Cyclone2 551 551 344 8 4 Cyclone3 439 439 365 Stratix 638 563 342 8 4 Stratix2 468 469 342 8 4 StratixGX 639 564 342 8 4 Spartan2 699 535 333 8 1 Spartan2E 715 530 332 8 1 Spartan3 687 525 332 2 1 Spartan3A 1048 872 360 Spartan3E 1283 1113 361 2 Spartan3L 1076 903 356 Virtex 697 534 333 8 1 Virtex2 697 532 333 2 1 Virtex2p 697 532 333 2 1 VirtexE 691 529 333 8 1 Virtex4 1014 858 344 2 Virtex5 11 11 11 ProAsicPlus 1961 16 ProAsic3 1756 8 ProAsic3E 1791 8 EC 936 795 356 4 ECP 936 795 356 4 MACHXO 978 837 4 XP 1028 838 376 4 SC 946 783 380 2 14 CR0134 (v1.10) July 17, 2008

LAX_4K16 Logic Analyzer 4K16 Cyclone 782 668 438 16 4 Cyclone2 676 676 440 16 4 Cyclone3 515 515 469 Stratix 799 684 438 16 4 Stratix2 616 617 438 16 4 StratixGX 800 685 438 16 4 Spartan2 869 656 422 16 1 Spartan2E 859 647 422 16 1 Spartan3 865 655 420 4 1 Spartan3A 1322 1095 456 Spartan3E 1473 1240 457 4 Spartan3L 1328 1098 452 Virtex 865 656 422 16 1 Virtex2 869 653 422 4 1 Virtex2p 869 653 422 4 1 VirtexE 863 651 422 16 1 Virtex4 1282 1070 440 4 Virtex5 19 19 19 ProAsicPlus 2584 32 ProAsic3 2297 16 ProAsic3E 2344 16 EC 1192 995 462 8 ECP 1192 995 462 8 MACHXO 1230 1054 8 XP 1272 1055 480 8 SC 1202 999 490 4 CR0134 (v1.10) July 17, 2008 15

LAX_8 Logic Analyzer 8 Cyclone 768 699 412 4 Cyclone2 693 694 413 4 Cyclone3 590 590 434 Stratix 770 700 412 4 Stratix2 598 599 411 4 StratixGX 769 700 412 4 Spartan2 877 655 387 1 Spartan2E 857 646 387 1 Spartan3 845 627 385 1 Spartan3A 1301 1074 413 Spartan3E 1398 1176 414 Spartan3L 1287 1063 409 Virtex 867 649 387 1 Virtex2 885 661 387 1 Virtex2p 871 649 387 1 VirtexE 869 646 387 1 Virtex4 1237 1012 413 Virtex5 27 27 27 ProAsicPlus 2374 ProAsic3 2236 ProAsic3E 2267 EC 1206 1013 441 ECP 1206 1013 441 ECP2 990 708 465 ECP2M 990 708 465 MACHXO 1228 1055 XP 1192 952 453 SC 1172 990 461 16 CR0134 (v1.10) July 17, 2008

LAX_16 Logic Analyzer 16 Cyclone 926 818 508 4 Cyclone2 813 814 509 4 Cyclone3 672 672 538 Stratix 945 836 508 4 Stratix2 726 727 507 4 StratixGX 945 836 508 4 Spartan2 1053 788 459 1 Spartan2E 1039 784 459 1 Spartan3 1031 770 457 1 Spartan3A 1505 1235 493 Spartan3E 1634 1356 494 Spartan3L 1513 1240 489 Virtex 1039 786 459 1 Virtex2 1065 807 459 1 Virtex2p 1065 805 459 1 VirtexE 1039 784 459 1 Virtex4 1493 1214 509 Virtex5 51 51 51 ProAsicPlus 2930 ProAsic3 2793 ProAsic3E 2840 EC 1436 1212 522 ECP 1436 1212 522 ECP2 1188 841 557 ECP2M 1188 841 557 MACHXO 1484 1270 XP 1430 1143 540 SC 1454 1217 567 CR0134 (v1.10) July 17, 2008 17

TERMINAL Instrument Terminal (Wishbone) Cyclone 167 116 Cyclone2 116 112 116 Cyclone3 116 113 116 Spartan2 277 236 109 Spartan2E 277 236 109 Spartan3 275 235 109 Spartan3A 275 235 109 Virtex 277 236 109 Virtex2 275 235 109 Virtex2p 275 235 109 VirtexE 277 236 109 Virtex4 275 235 109 Virtex5 8 8 8 ProAsicPlus 397 2 ProAsic3 309 EC 180 126 116 ECP 180 126 116 ECP2 180 126 116 ECP2M 180 126 116 SC 166 126 116 XP 180 126 116 MACHXO 168 126 18 CR0134 (v1.10) July 17, 2008

Tools Utilized The following vendor device tools were used to determine the resource usage statistics: Actel Actel Designer Software Version 6.2 Altera Quartus II 5.0 Lattice isplever 5.0 Xilinx Xilinx ISE 6.3 For Virtex4, Spartan3, Spartan3E the Xilinx ISE 7.1 was used. CR0134 (v1.10) July 17, 2008 19

Revision History Date Version No. Revision 6-Dec-2004 1.0 Service pack 2 release 12-Apr-2005 1.01 Added Virtex4 and Stratix2 resource usage 6-Jun-2005 1.02 Added MAX2 resource usage 15-Sep-2005 1.03 Added EC, ECP, Spartan3E, Cyclone2 and StratixGX resource usage 29-Dec-2005 1.04 Added ProAsic3 20-Apr-2006 1.05 Tools Utilized section added 15-Jun-2006 1.06 Proasic3E and XP added 31-Jul-2006 1.07 MACHXO added 1-May-2007 1.08 Cyclone3, ECP2, ECP2M, Spartan3A, Spartan3E, Spartan3L and Virtex5 resource usage added. 4-Jul-2007 1.09 Terminal And configurable DIGITAL IO Core added. 17-Jul-2008 1.10 Altium Designer Summer 08 SP1 Software, hardware, documentation and related materials: Copyright 2008 Altium Limited. All rights reserved. You are permitted to print this document provided that (1) the use of such is for personal use only and will not be copied or posted on any network computer or broadcast in any media, and (2) no modifications of the document is made. Unauthorized duplication, in whole or part, of this document by any means, mechanical or electronic, including translation into another language, except for brief excerpts in published reviews, is prohibited without the express written permission of Altium Limited. Unauthorized duplication of this work may also be prohibited by local statute. Violators may be subject to both criminal and civil penalties, including fines and/or imprisonment. Altium, Altium Designer, Board Insight, Design Explorer, DXP, LiveDesign, NanoBoard, NanoTalk, P-CAD, SimCode, Situs, TASKING, and Topological Autorouting and their respective logos are trademarks or registered trademarks of Altium Limited or its subsidiaries. All other registered or unregistered trademarks referenced herein are the property of their respective owners and no trademark rights to the same are claimed. 20 CR0134 (v1.10) July 17, 2008