SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO.

Similar documents
Catalog HY /US Flow Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE LPM/GPM BAR/PSI

Pressure Control Valves

Pressure Control Valves

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

P.C. Priority Flow Control Valve Series J02D3. General Description

Service and Parts Manual. Minimum Filtration Required:

three different ways, so it is important to be aware of how flow is to be specified

HYDRAULIC VARIABLE PUMPS

LogSplitterPlans.Com

Full Range Pressure Compensating Variable Flow Control

2. Hydraulic Valves, Actuators and Accessories. 24 Marks

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

OPERATION AND PARTS MANUAL

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US

PRESSURE REDUCING VALVE

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

4 Flow Control Valves. Notes

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

Series PAVC Variable Volume, Piston Pumps

EZH and EZHSO Series. Pressure Reducing Regulators. EZH and EZHSO Series. Introduction. Scope of the Manual. Product Description !

VB VALVES & AUTOMATION

PRESSURE REDUCING CONTROL VALVE

Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital)

Type 310A-32A Pressure Reducing Regulator

Pressure Control Valves

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

Series PVP Variable Volume Piston Pumps

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

800SVRM-7 5/04 RATE-OF-FLOW CONTROL 800 SERIES CONTROL VALVES

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

Baumann Mikroseal Control Valve

FULL RANGE PRESSURE COMPENSATING VARIABLE FLOW CONTROL

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Type FL Pressure Reducing Regulators

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

CHAPTER 11 BASIC ACTUATING SYSTEMS

SERIES 8100 HAND-OPERATED PRESSURE CALIBRATION UNITS

t2_ il PioC Oper. led Relet Valve Symbol ~~~ CHAPTER 12 Pilot Operated Pressure Control Valves

Open Center Compact Valve Custom Installation Guide Rev A

VSK. Functional Description HA /2008. Constant Flow - Control Valves VSK4 VSK2 VSK2 VSK4. Replaces HA /2000

Installation, Operation & Maintenance Manual for Flo-Max Couplers Model FM

Contents. Quality Hydraulic Components from the Webtec Range. Introduction. Hydraulic Flow Control Valves

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

Fisher 657 Diaphragm Actuator Sizes and 87

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

Section 6.1. Implement Circuit - General System. General: Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

627 Series Pressure Reducing Regulators

Baumann Sanitary Angle Control Valve

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

Powers TM Controls RL 243 SW Switching Relay

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Monoblock Directional Control Valve PMB22TSTSAB PMB23TSTSTSLB PMB21TDLB

GBV-G Balancing Valves

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Implement and Steering/Hydraulic System Testing and Adjusting

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised

627 Series Pressure Reducing Regulators

Operation & Service Manual

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Float Valve MODEL. Schematic Diagram. Optional Features. Typical Applications. Installation. Product Dimensions Data:

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

Fisher 585C Series Piston Actuators

Hydraulic Winch Assembly Instructions

Type 644 and 645 Differential Pressure Pump Governors

Section 35 Chapter 2 HYDRAULIC SYSTEM HOW IT WORKS AND TROUBLESHOOTING NH

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

Accessories. Section Outline

627 Series Pressure Reducing Regulators

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

WARCO CHEMAG SERIES GH FILTERS

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

Service Handbook. High-Pressure Washer Pump

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

Model 3201 Liquid Level Controller

cs200 series commercial / Industrial pressure reducing regulators

Chapter 5: Flow Valves

781Mini Series Spray Valve

CLS100 Proportional Load Sensing Mobile Valve

CP400 Series Commercial/Industrial Pressure Loaded Pressure Reducing Regulators

Hydraulic and Pneumatic In-line and Cartridge Insert Control Valves for any fluid or gas.

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators

4-Way Directional Control With Pressure Compensated Flow Control PSDCF120M64LF Specifications:

Model DF269 Control Valve

Transcription:

Contents SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO. NVH081...12CNVH1...Needle Valve...10 GPM... 5500 PSI... FC5-FC6 NVH101...15CNVH1...Needle Valve...16 GPM... 5500 PSI... FC7-FC8 NV162...21CNV2...Needle Valve...50 GPM... 3000 PSI... FC9-FC10 NV102...15CNV2...Rotary Needle Valve...15 GPM... 3500 PSI... FC11-FC12 FV101...15CFV1...Needle w/check...12 GPM... 3000 PSI... FC13-FC14 FV102...15CFV2...Needle w/check (Fine adj.)...6 GPM... 3000 PSI... FC13-FC14 FR101...15CFR1...P.C. Flow Regulator...7 GPM... 3500 PSI... FC15-FC16 FC101...15CFC1...P.C. Flow Control...15 GPM... 3000 PSI... FC17-FC18 FA101...15CFA1...P.C. Flow Control...(Fully Adjustable)...5.5 GPM... 3000 PSI... FC19-FC20 FP101...15CFP1...P.C. Priority Flow Regulator...9 GPM... 3500 PSI... FC21-FC22 VF101...15CVF1...Velocity Fuse...8 GPM... 3000 PSI... FC23 FCR101...15CFCR1-F...Pressure Compensator...10 GPM... 3500 PSI... FC24 FCR161...21CFCR1-F...Restrictive-Type Press. Comp....40 GPM... 3500 PSI... FC25 FCP101...15CFCP1-F...Priority-Type Press. Comp....10 GPM... 3500 PSI... FC26 FCPH121... 17CFCPH1...Priority-Type Press. Comp....20 GPM... 5500 PSI... FC27-FC28 FDC101...15CFDC...Flow Divider/Combiner...12 GPM... 3500 PSI... FC29-FC30 index.pm6.5, bl, 6/04 *For Reference Only. Denotes New Winner s Circle Product Line.

INTRODUCTION This technical tips section is designed to help familiarize you with the Parker line of. In this section we present common options available as well as a brief synopsis of the operation and applications of the various product offered in this section. The intent of this section is to help you in selecting the best products for your application. COMMON OPTIONS As you will see, Parker offers a variety of Flow Control products. As such, some of the options mentioned below may not be available on all valve models. Consult the model coding and dimensions of each valve for specifics. Here are some of the common options available. Adjustment Types: Parker offers four primary types of adjustments for most of the flow control products. Samples of these types are shown below. Please note all options may not be available for all valves. Consult the individual catalog pages for more details. Screw Adjustment - Valve can be adjusted with an allen wrench. Lock nut included to maintain desired setting after adjustment. This is the most common adjustment option available on most Parker products. Knob Adjustment - An aluminum knob is added to the standard screw adjustment. A lock knob is provided to help maintain the desired setting after adjustment. Parker offers knob conversion kits for most flow control valves. For kit numbers consult the individual valve pages. Fixed Style - In most cases, the Fixed Style product is a screw adjustable product with a steel collet threaded over the adjustment. These valves are preset at the factory. Should the valve need to adjusted, the star washer and aluminum plate can be removed from the top of the assembly exposing the adjustment. Tamper Resistant - The tamper resistant option is a screw adjustable valve with a steel cap installed to conceal the adjustment. The cap is designed so the internal edges clamp into the groove of the valve adapter. Once the cap is installed, it cannot be removed without damaging the cap and the valve. When a valve is ordered with the tamper resistant option, it will be preset at the factory, and the cap will be included in a separate plastic bag to allow for fine tuning at the customer site. Parker offers tamper resistant cap conversion kits for most flow control valves. For kit numbers consult the individual valve pages. Seals: The Winner s Circle products feature a standard 4301 Polyurethane D -Ring. The D -Ring eliminates the need for backup rings.the majority of the products are available in Nitrile or Fluorocarbon Seals. You should match the seal compatibility to the temperature and fluid being used in your application. Fine Meter Options: Fine meter needles are offered on some needle valve series. When this option is specified, the standard needle is replaced by a slotted needle. The slotted needle restricts substantially more flow giving you finer control in the small flow ranges. Obviously, the maximum flow capacity of the needle valve is decreased with the fine meter option. Coarse Needle Fine Needle FC1

PRODUCT TYPES / APPLICATIONS Needle Valve Needle valves provide uncompensated adjustable flow control of a desired function. They are ideal for applications where general control of hydraulic flow is needed, like in a bleed off circuit. When used with a compensator spool, a pressure compensated system can be obtained. OPERATION - The valve acts as a fixed orifice in a hydraulic circuit. The effective size of the orifice increases as the tapered needle is opened. Shutoff is provided when fully closed. While a needle valve will meter flow regardless of the flow path, flow from port 2 to 1 is preferred. When you flow in the reverse direction (1 to 2), pressure forces work on the nose of the needle in an effort to drive it off of its seat. As such, all leakage conditions found in the catalog are based on flow from side to nose (port 2 to port 1). In addition, the adjustment will be harder to turn due to the added force. Rotary Style Needle Valve Rotary style needle valves are a special spool type of needle valve. The primary advantage of the rotary style needle valve is that a detented style knob can be specified to provide 10 independent set points. Since the needles in these valves are rotary spools, they should not be used in applications where complete shutoff is expected. OPERATION - Rotary needle valves consist of a spool type needle inside a sleeve with intersecting milled slots. As the needle is rotated counterclockwise, the area of the flow path is increased. Flow is metered regardless of whether you move from port 1 to port 2 or vice versa. Needle with a Reverse Check Needle valves with reverse check functions are sometimes also referred to as flow control valves. As the name implies, these valves provide uncompensated adjustable speed control in one direction and allow free flow in the opposite direction. When used with a compensator spool, a pressure compensated system can be obtained. OPERATION - With flow entering the side of the cartridge (port 2), the needle acts as a fixed orifice. The effective size of this orifice is increased as the needle is opened controlling the output flow to port 1. With flow entering the nose (port 1), the check ball inside the needle is unseated allowing free flow to port 2. FC2

P.C. Flow Regulator Pressure compensated flow regulators maintain a regulated flow regardless of changes in load or inlet pressure. They are commonly used to accurately control an actuator function. They can be used in meter-in or meter-out applications. OPERATION - The valve consists of a control orifice within a normally open, spring biased compensator spool. Flow through the control orifice produces a pressure drop across the compensator spool. When inlet flow exceeds the flow setting of the valve, the force produced by the pressure differential across the spool exceeds the spring force and shifts the compensator spool to throttle or restrict flow; thus maintaining consistent flow through the valve. In the reverse direction, flow is metered, but not pressure compensated. P.C. Flow Control Pressure compensated flow controls are pressure compensated regulators with a reverse flow check valve. They provide constant regulated flow in the one direction regardless of changes in load pressure. Flow in the reverse direction is non-regulated, free flow. They can be used in meter-in or meter-out applications. Fully Adjustable Version: Most pressure compensated flow control valves have a limited adjustment range (i.e..3-1.0 GPM) due to the internal orifices being fixed. To change flow ranges a new orifice is needed and thus a new valve model. The fully adjustable versions (i.e. FA101) utilize a variable needle instead of fixed orifice and as such can be adjusted through the full flow range of the valve (.2-5.5 GPM). Thus, with fully adjustable valves, you do not need to change valves to change the flow setting. OPERATION - When flow enters the nose (port 1) of the cartridge, it passes through a control orifice. This control orifice creates a pressure differential across the regulating spool. As the inlet flow increases, the pressure differential across the regulating spool increases, allowing the regulating spool to overcome its spring force and begin to shift. As it shifts, it throttles to maintain a constant flow. When used in conjunction with a fixed displacement pump, a relief valve between pump and valve is needed. Full flow is allowed in the reverse direction (port 2 to 1) Priority Style P.C. Flow Regulator Priority style pressure compensator regulators maintain constant priority flow to one leg of the circuit regardless of changes in load or inlet pressure. Once this priority flow requirement is satisfied, the excess flow is diverted and can be used in another leg of the circuit. These valves are usually used in meter-in applications. (3) OPERATION - The valve consists of a control orifice within a spring biased compensator spool. The priority port is normally open while the bypass port is normally closed. As flow enters the inlet of the cartridge and passes through the control orifice, a pressure differential is created across the compensator spool. When the inlet flow exceeds the setting of the valve, the force produced by this pressure differential exceeds the spring force and shifts the compensator spool; opening up the bypass port, and bypassing the excess flow. If load pressure at the bypass port is greater than the load pressure at the priority port, the compensator spool will further shift restricting the priority flow to that of the valve setting. Caution: If the priority line is blocked so that no flow can pass through the control orifice, the compensator spool will shift, blocking the bypass port and allowing inlet pressure to go to full system relief pressure. These valves do not provide a pressure relieving function, so it is common to place an external relief valve downstream of port 3 to prevent a no flow condition. FC3

Compensator Valves Compensator valves are used to provide pressure compensated control across an external fixed or adjustable orifice. Parker offers both the restrictive type of compensator and a priority style. Restrictive Type Priority Type Priority Type Restrictive Type OPERATION - Restrictive Type: Inlet flow (upstream of the orifice) is split with one portion going to the compensator port inlet (port 1), the other portion passes through the orifice to the supply port (3) (4) (port 3). As pressure drop across the orifice reaches the selected compensator pressure drop, the higher pressure (pre-orifice) at port 1 starts to shift the compensator spool into throttling position. The valve works to maintain a constant pressure drop across the orifice. Priority Type: Flow through the external orifice into the supply port (port 4) produces a pressure drop across the compensator spool. When the inlet pressure exceeds the initial setting of the valve, the force produced by the pressure differential across the spool exceeds the spring force and shifts the compensator spool to throttle or restrict the flow, thus maintaining constant flow through the priority port (port 3). The excess flow is bypassed to port 2. Regulated port flow must be maintained for bypass flow to continue. (3) Velocity Fuse Velocity fuses are special devices used to control the maximum speed of fluid. Should maximum flow exceed a preset value, the valve closes or shutoffs blocking further flow. Velocity fuses are primarily used as protection Fusing Direction Reversing Flow Direction for unexpected hose breaks. Should a hose break the velocity fuse shuts off preventing the load from dropping and keeping hydraulic oil from spraying out onto the floor or ground. OPERATION - Oil enters the nose (port 1) of the cartridge (fusing direction) and passes through orifices in the spool prior to exiting the valve. As it passes through the valve, a pressure differential is created between inlet flow and downstream resistance. This pressure differential is also sensed in the spring chamber of the valve. If the flow rate between the inlet and outlet remains within the specified pressure differential of the valve, the valve remains open. If a sudden decrease in downstream resistance occurs, it will increase the pressure differential through the velocity fuse. This will then cause the spool to shift, closing the spool. For optimum performance, the velocity fuse should be calibrated for 30% over normal system flow requirement. To reopen the valve, either reverse the flow through the valve, or reduce the pressure differential (inlet to outlet) to less than 70 psi. Flow Divider / Combiner Flow divider / combiner valves are used to proportion the flow from a single source into two actuators. In the reverse mode, the valve takes the flow from the two sources and combines it into one flow. When attempting to synchronize two cylinders with Divider Outlets Combiner Inlets Divider Inlet Combiner Outlet a flow/divider combiner valve, please consider that the flow accuracy is +10%. A crossover relief can be used to help re-synchronize the cylinders by bottoming them out after several cycles. OPERATION - When flow enters the divider inlet port, it will pass through orifices in each of the interconnected spools. The flow passing through the orifices creates a pressure drop which pulls the two spools away from each other. The flow then passes to the two divider outlet ports. The division of flow (i.e. 50-50, 60-40, 66-33, etc.) is determined by the orifice sizes in the two spools.when flow is being combined, it enters the valve through two combiner inlets. The pressure drop across the orifices pulls the two spools together. The combined flow then passes through the combiner outlet. (3) (4) FC4