GEF~4630A. Limitamp Medium-Voltage Motor Control. CR7160 Renewal Parts Bulletin

Similar documents
DEF-002. Vacuum Limitamp Medium Voltage Motor Control. wal Parts

DEF-002. Vacuum Limitamp Medium Voltage Motor Control CR194

CR193 B,C,D and E Vacuum Limitamp * Contactors

Evolution * Series E9000 Motor Control Center

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

~

GE Industrial Solutions. Limitamp * AR. Arc Resistant Medium Voltage Motor Control. Installation Guide

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

CR193 Vacuum Limitamp* Contactors

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

Section 18. Medium Voltage Equipment. BuyLog Catalog 18-1

Ampgard medium voltage motor control renewal parts

Power Break Circuit Breakers

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

SIGNAL WORDS QUALIFIED PERSON

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Multi-Pak Group Control

Medium Voltage Equipment. Section 15.

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Installation Instructions For Motor Control Center (MCC) Units

Instructions for AMPGARD 400A medium voltage starter

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

Class E2 Medium-Voltage Controllers with Drawout Vacuum Contactors

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

Design Standard. Purpose: Design Standard:

SECTION MOTOR CONTROL

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Medium Voltage Metal-Enclosed Switches

Basics of Medium Voltage Motor Control Starter Power Components & Starter Types

SECTION MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

SECTION 6 PARTS LIST

Power/Vac OEM Express Switchgear

Unit Substation Transformers 5 and 15 KV Class

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

www. ElectricalPartManuals. com Digitrip Retrofit System for the Westinghouse DA-50 IL 33-DAC-2 WARNING

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Cutler-Hammer. AMPGARD MV Motor Control Vacuum Break SJ Series II II. Renewal Parts. r II li I. Pages. Contents. Effective: March 2000 Page 1

MicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers

SecoVac * Ground & Test Device

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

DEH Installation

Installation Sheet January, 2016 Supersedes February, 2013

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Isolation Switch (behind barrier & inspection window) Power Fuses. Load Cable Connection Box. Contactor. Control Power Transformer Secondary Fuse

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

Power Break II Switchboard

C1000 Series Automatic Cap Bank

Industrial Control Transformers

www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438

Product Guide. NEMA pump controls.

Power Break II Circuit Breaker Accessories Motor Operator Mechanism

Florham Park, NJ USA Call (ASCO) for sales or service

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Medium Voltage Metal-Enclosed Switches

C E R T I F I C A T E O F C O M P L I A N C E

7. SERVICES OVER 600 VOLTS

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Operation and Maintenance Manual

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA)

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Wye or Delta Systems DS9181 (CSA Approved)

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

SafeGear TM Motor Control Center Arc resistant metal-clad construction

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

CONTAINER GUIDE WELDMENTS

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

USER MANUAL Bulletin 1512A 400A One-High Cabinet Standard and Arc-Resistant Enclosure

Florham Park, NJ USA Call (ASCO) for sales or service

Critical Power Switchboards. Selection and Application Guide

Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units

POWERCON CORPORATION

Transcription:

GEF~4630A Limitamp Medium-Voltage Motor Control CR7160 Renewal Parts Bulletin

',; @ Limitamp" Medium VoUage Matar Control Table of Contents Introduction...2 Parts Identification...2 High-Voltage Contactor Nameplate...2 Limitamp Panel Data Nameplate...3 Catalog Numbering...3 One-High Construction....4, 5 Two-High Construction... 6, 7 Three-High Construction... 8, 9 Handle Assembly... 10 Bus Assemblies... 11, 12 Fuse Support Assemblies (Control Power Transformer)...13 Stab & Track Assemblies...13 Warning: Before any adjustments, servicing, parts replacement or any other act is performed requiring physical contact with the electrical working components or wiring of this equipment, all power must be removed and locked off from all sources and all attached rotating equipment must have come to a complete stop. User personnel must be completely familiar with the following operating and maintenance instructions before attempting to service this equipment.

Introduction The CR7160 Limitamp Controller, a quality GE product, was designed and manufactured to give long and satisfactory service. This bulletin contains items that, through normal use, may require periodic replacement; other items may never need service or replacement during the useful life ofthe equipment. Reference Publications GEH-3091 Instructions for Air Break Controllers GEH-3102 - Instructions for Contactor GEH-3140 -Application Data GET-6840 - Application and Selection Guide GEH-4989 - CR7160 Draw out Vacuum Contactor For additional assistance, please refer to factory. Parts Identification This bulletin will provide the information necessary to identif}', by description or actual catalog number, replacement parts for CR7160 Limitamp Motor Controllers. The following pages will describe where important equipment identification numbers can be found and provide catalog numbers for assemblies and individual parts that may require periodic replacement through normal wear. Table 1. CR7160 Publication Abbreviations High-Voltage Contactor Nameplate High-voltage contactor renewal parts are found in separate renewal parts publications depending on the contactor catalog number. This catalog number is found on the contactor nameplate mounted on the steel bracket directly above the contactor coil. An example of this nameplate is shown below: Figure I. High-Voltage Contactor Nameplate The proper publication can be selected from the following table: Table 2. CR7160 IDgh-Voltage Contactor Renewal Parts Publications Contactor Catalog Number IC302A IC302B IC302C IC3020 IC302E IC2814 CR7160 Air Break Renewal Parts Publication GEF-4551 GEF-4573 GEF-4574 GEF-4575 GEF-4576 GEF-4337 AC Alternating Current LH Left Hand Asm. Assembly LV Low Voltage Cont Contactor MB Main Bus CPT Control Power Transformer NC Normally Closed CT Current Transformer NO Normally Open GFCT Ground Fault Current NP Nameplate Transformer PT Potential Transformer Horz. Horizontal RH Right Hand HV High Voltage Supt Support Inc. Incoming VB Vertical Bus Instr. Instruction Contactor Catalog Number CR193V CR193W CR7160 Vacuum Renewal Parts Publication GEF-8017 GEF-8017 Should a situation arise in which a part cannot be identified, the factory should be contacted. In order for the factory to provide assistance in identifying the part, the Catalog Number and Diagram Number of the equipment must be known (see Limitamp Panel Data Nameplate). 2

Limitaml' Medium Voltage Motor Control Limitamp Panel Data Nameplate This nameplate is mounted near the starter handle operator on the high-voltage door. It contains all the necessary information for the factory to positively identify the starter and its bill of material. This information must accompany all part orders and quotation requests. An example of this nameplate is shown below: ~gg~te DIAGRAM 221 B3466 SCHEMA-~-----,-,--------'---- POWER FUSE CAT.NO. -2-1-8-A4~2-9~1P~ ~R=B~----'- FUSIBLE DE PUIS., N CAT. INTERRUPTING RATING 35 o MVA CLASS E _...,...,,.._ 2 POUVOIA DE COUPUAE MVA CLASSE E 3_PHASE.wL_HZ.1llil.Q_VOLTS AC KV BIL VOLTS C.A. KV TTC CONT. CUR. RATING AMS AMPERES 40'C AMB. COUR.,SERVICE CONT. EFF., A.40 C AMBIANTE SERVICE LIMIT l.,ua. RATING.-,,,- AMS AMPERES COUAANT LIMITE EN SERVICE EFF., AMPERES HORIZ. BUS CUR. RATING AMS AMPERES GOUR. NOM., BUS HORIZON EFF., AMP.E.RES CONTROL CIRCUIT 1_1s VOLTS CIRO. DE COMMANDE V POWER CIRCUIT MAX. VOLTS AC CIRCUIT DE PUISSANCE, MAX. V C.A. LOAD: TYPE_.,_.,FULL LOAD CUR.._._AMP. CHARGE: TYPE GOUR.PLEINE CH. A W.R. MOTOR SEC. V AC AMP. MOTEUA SECOND., ROTOR BOB. V C.A. A SYNC. FIELD...c.;.,.~V DC AMP. JjJL_P.F. CHAMP SYNC. V CC A F.P. CAUTION BEFORE INSTALLING OR OPERATING READ INSTRUCTIONS ATTENTION.. LIRE LES INSTRUCTIONS AVANT DE PAOC!:'DEA At:INSTALLATION GEH-3091 GEH,3102 Catalog Numbering System Limitan1p control is manufactured in three construction types: one-high, two-high and three-high. One-high construction consists of one medium-voltage contactor in one 90.inchhigh enclosure. Two-high construction contains two mediumvoltage contactors in one 90.inch-high enclosure. Three-high construction has three medium-voltage cont.actors in one 90- inch-high enclosure. You should first determine the construction type ( one-high, two-high or three-high) ofyour equipment. After determination, the following pages should be consulted: Pages 4 and 5 for one-high construction Pages 6 and 7 for two-high construction Pages 8 and 9 for three-high construction Caution should be observed in that a part number in onehigh construction may have a different description and catalog number than the same part number in two- or three-high construction. Another method of identifying construction is through the controller "CR" number (shown on the panel data nameplate). Example: Catalog Number 7160Al 18G. 11ze alpha suffix determines one-high, two-high or three-high; G is one-high, K is two-high and His three-high. Vacuum starters are designated by an M suffix. Example: Catalog Number 7160Al 18G1vl. This "CR" number is further referenced in GEH-3091. DO NOT OPERATE STARTERS FURNISHED WITH CURRENT TRANSFORMERS UNLESS RELAY ELEMENJS ARE INSTALLED. NE PAS UTILISER LES DEMARREURS f-ournis AVEC LES TRANSFORMATEURS DE COURANT AVANT QUE LES RELAIS SO!ENT INSTALlES Figure 2, Limit.amp Panel Data Nameplate The required information is the catalog number and the diagram number. The catalog number from the sample above is 0607X0431V02 AOL The number can be broken down as follows: 0607X0431 is the material list number or shop order number for the job, V02 is the overall lineup designation, and AOl is a section in that lineup. The diagram number identifies the group of drawings that pertain to this particular project order. Sections that do not have a panel data nameplate vvill have a compartment nameplate mounted on the right side door flange. An example is shown below; Figure 3, Limitamp Compariment Nameplate This will provide the catalog number only. The diagram number can be obtained from any PanelDataNameplateon that lineup. 3

One-High 170 Figure 4. CR7160 One-High Notes: 290 Not Shown 500/501/502 - Located on LV Base 578/579 - Located at rear of Swingout (item 550) 803 - Mounted on Contactor 4

Limitamp Medium Voltage Motor Control Table 3. CR7160 34" Wide One-High DrawoutAir/Vacuum Parts List (See Figures 4 and 5) Material List Item Part Descriplion Pert Number Qty, Number 115 lintel 68J210552AM3411M1'B 1 122 Lintel Catch 194A7164Gt 1 170 Wire Trough 68J222210CBOOOOAAB 1 187 Compartment Barrier Asm, 117B4515G6 1 194 Door Interlock Defeater 194A6916G1 1 65 209 CPT Primary Fuse Supt. Asm, 55C682289G* 0 1 0 212 Intermediate Stab Asm. w/o PT 149B1743G6 1 212 Intermediate Stab Asm. w/ PT 149B1743G5 1 218 Handle Asm. 116C9928G* @ 1 250 CPT Mountina Base 68J210552AB34XXXXB 1 268 AC Bus Copper 104B9369P* @) 3 274 AC Splice Copper Consult factory 3 65 289 Ground Bus 104B9334P* 0 1 290 Ground Bus Link-Copper 232A9331 P* @ 1 @ 295 Ground Bus Splice-Copper Consult factory 1 0 302 Window CT Supt. 219A1229P1 3 659 3D8 Dummy CT Plate 394B686G11 3 309 Motor Stab Asm. 149B1743G4 1 326 Multilin GFCT Supt. 68J 122212VHOOOOAAB 1 326 2-1/2" Window GFCT Suot. 219A1229P1 1 500 Test Switch 10A CR104PSG21 B92 1 500 Test Switch 20A 328A1141P1 1 0 ~ 501 Switch NP 10A 328A1140P1 1 501 Switch NP 20A Included with item 500 (20A) 1 @ 502 Test Switch Mountina Bracket 68J122214NSOOOOAAB 1 0 550 Swingout Panel 68J222222SMOOOOAAB 1 659 553 LV Base 68J120132BT0504AAB 1 578 Swingout Barrier 68J 122220DTOOOOAAB 1 579 Swingout Barrier 68J122220DSOOOOAAB 1 653 LV Door Consult factorv 1 656 Bottom Door Consult factory 1 659 Door Latch Asm. 104B9336G2 3 Figure 5. CR.7160 One-High Door Detail 666 Door Hinge Pin 1459941P1 6 667 Ooor Hinge 147A4728G1 6 722 Swinu Base Stoo-Barrier 68J120125DLOOODAAB 1 723 Wire Harness 7118R50G2V 1 724 Control Wire Plug-Bottom 128C6635P1 1 724A Control Wire Plug-Top 128C6636P1 1 724B Plug Socket AMP# 350638-1 15 724C Pluo Pin AMP# 350639-1 15 7240 Crimper Tool AMP# 90124-2 1 728 Coil Plug 169B7635G5 1 729 Wire Plug Supt. 219A1225P1 1 730 Wire Comb Cleat 171B4725P1 3 731 Wire Comb Cover 171B4726P1 3 732 Wire Comb Supt. 219A1242P1 1 736 Swingout Handle 104B9322P6 1 750 AC Bus Barrier line. Line) 149B1753G1 1 750 AC Bus Barrier (no Inc. Line) 149B1753G2 1 751 VB Barrier Asm. (Inc. Line) 1498175384 1 751 VB Barrier Asrn. (no Inc. Line) 149B1753G3 1 752 Lower Inc, Line Barrier Bottom 194A6985G1 1 753 Upper Inc. Line Barrier 245A4374G3 1 754 Lower Inc. Line Barrier Upper 68J120125MFOOOOAAB 1 755 VB Barrier Bottom Cover 194A6968P2 1 756 Barrier Extension 302A3732P1 1 757 Lower Inc. Line Barrier Center 68J120125MGOODOAAB 1 759 AC Bus Barrier Upper Shelf 68J210553AJXXXXXXB 1 762 Shutter-Bus Asm. 194A4480G* 1 803 Power Fuse @ 3 859 Bus Cover Plate 68J120125BMOOOOAAB 2 861 Cable Cover Plate 194A7197P5 2 879 PT Base 68J120131ALOOOOAAB 1 881 PT Insulator 205A4475P2 1 0 See Table 19, @ Add suffix (*) per plating finish: @ See Tables 6 and 7. l=no 2=Silver, SccTin. @) See Table 9. See Table 11. 0 See Table 12. @ See panel data NP for fuse part number. 5

Two-High rn rn rn l6l 16'! Figure 6. CR7160 Two-High 6 Notes: 290 - Not Shown 500/501/502 - Located on LV Base 720 - Not Shown 803 - Mounted on Contactor 860 - Not Shown

Table 4. CR7160 44" Wide Two-High Air/Vacuum Parts List (see Figures 6, 7 and 8) Material Malarial List Item Part Description Part Number Illy. List Item Part Description PartNumbar Qty. Number Numbar 108 Plug Button N529P63B6 1 310 Track & Barrier Asm. 116C9939AAG2 1 115 Left Track Supt. 139B8564G3 1 315 Door Interlock Defeater Upper 194A6916G1 1 116 Right Track Supt. 139B8564G4 1 315 Door Interlock Defeater Lower 194A6916G4 1 129 Washer Plate 194A7383P1 6 500 Test Switch 10A CR104PSG21B92 1 160 Vertical Lintel 6BJ220134FD0OO0AAB 1 500 Test Switch 20A 328A1141P1 1 161 Bottom LV Lintel 14983258P1 1 501 Switch NP 10A 328A1140P1 1 162 Bottom HV Lintel 68J 120134JD0000AAB 1 501 Switch NP 20A Included with item 500 I20A) 1 163 LV Mullion 174A8913G1 1 502 Test Switch Mounting Bracket 68J122214NS0000AAB 1 164 Dust Shield NEMA 1 68J120125EU0000AAB 1 508 Terminal Board Supt 194A7176P1 3 170 Wire Trough 68J220134FU0000AAB 1 553 LV Base 68J120125GL0000AAB 1 171 Upper LV Lintel 233A1836G1 1 632 LV Door Latch Asm. 1178506463 2 172 Upper HV Lintel 68J 120134FR0000AAB 1 635 HV Door Latch Asm. 104B9336G2 2 173 Lintel Latch Screw Asm. 174A7367G1 2 646 HV Door Vent Barrier NEMA 1 205A4475P2 1 174 RH Center Mullion 259A1447G1 1 646 Vent Cover NEMA 1A, 2, 12 68J120134EE0102AAB 1 175 CPT Fuse Base Asm. 68J 220134FHOOOOAAB 1 653 LV Door Consult factorv 1 176 CT Supt. Asm. 177B2069G1 1 656 HV Door Upper 68J210551 CMXXXXXXB 1 180 CT Barrier 259A1452P1 1 656 HV Door Lower 88J210551CLXXXXXXB 1 181 CT Supt. 68J 122217EY0000AAB 1 667 Door Hinge 147A4728G1 6 186 Coil Plug 189B7635G5 1 868 Hinge Pin 1459941P1 6 211 HV Bushing 577A180P3 2 700 Uooer Motor Cable Barrier 68J220134FS0000AAB 1 218 Handle Asm. 116C9928G* 0 1 702 Inc. Line Barrier Upper 68J220134FK0000AAB 1 250 Bus Insulation!Back Cover) 149B1741P1 1 704 Inc. Line Barrier Lower 68J 120134FM0OO0AAB 1 268 Horz. & VB Asm. 116C9952G* @ 1 705 LV Base Barrier 68J 120125FROOOOAAB 1 274 Main Bus Splice Consult factory 1 707 RH Rear Barrier Upper 68J210553BAXXXXXXB 1 275 Motor Terminal Asm. Uooer 157C8151G2 1 708 RH Rear Barrier Center 68J 120125FD0000AAB 1 275 Motor Terminal Asm. Lower 149B1779G6 1 709 RH Rear Barrier Lower 68J210553BBXXXXXXB 1 276 Compartment Barrier 88J120134FP0000AAB 1 711 Bottom VB Barrier 194A6988P2 1 289 Ground Bus 14885352P* ~ 1 715 RH Motor Barrier Upper 68J220134FY0000AAB 1 295 Ground Bus Splice Consult factory 1 716 RH Motor Barrier Center 68J220134FE0000AAB 1 299 Ground Wire Harness 7118R29 1 717 RH Motor Barrier Lower 68J120134FT0000AAB 1 300 Vertical Ground Bus 68J122218RG000BB* 0 1 718 RH Motor Barrier Front 68J120134FW0000AAB 1 300 Lower Track Spacer 194A7014P2 2 720 Upper Wire Harness 7122R81G2V 1 301 Upper Back Horz. Ground Bus Strap 68J122218RH0000BB' 0 1 720 Lower Wire Harness 7122R82G3V 1 302 Back Vertical Ground Bus 68J122218RJ0000BB* 0 1 728 Contactor Latch Asm. 194A6949G1 1 303 Front Vertical Ground Bus 68J122218RK0000BB* 0 1 742 Shutter Asm. 116C9931G1 1 304 Vertical Ground Bus Connection 68J122218RL0000BB* 0 1 803 Power Fuse @ 3 305 Lower Vertical Ground Bus 68J122218RM0000BB' 0 1 859 Bus Cover Plate 68J120125BM0000AAB 2 306 Upper Front Vertical Ground Bus Strap 68J 122223EN0000BB* 0 1 880 Cont Lift Truck 116C9918G4 1 309 Motor Stab Asm. Upper 116C9929G2 1 0 @ See Tables 6 and 7. @ See Table 13. @ See Table 15, 0 Add suffix (*} per plating finish: N=no plating, TC=Silver, TB=Tin. See Figure 8 for motor ground bus detail. @ See panel data NP for fuse part number. 0 / 0 ~ 0 r-----------, L------ --J @) 0 p~ : J D,i,~~vs Figure 7. CR7160 Two-High Door Detail Figure 8. CR7160 Tuo-High Motor Ground Bus Detail 7

Three-High Figure 9. CR7160 Three-High 8 Notes: 500/501 /502 - Located on LV Base 720-Not Shown 803 - Mounted on Contactor 850/851/852 Not Shown 860 Not Shown

f I ~ Limitamp Medium Voltage Motor Co11trol Table 5. CR7160 44" Wide Three-High Air/Vacuum Parts List (see Figures 9, IO and 11) Material Materiel List!tam Part Description Part Number Qty. List Item D ~riplion PartNumbar Oty. Number Number 108 Plug Button N529P63B6 1 501 Switch.NP 10A 328A1140P1 1 115 Left Track Supt. 139B856463 1 501 Switch NP20A Included with item 500 (20A) 1 116 Right Track Supt. 139B8564G4 1 502 Test Switch Mounting Bracket 68J122214NS0000AAB 1 129 Washer Plate 194A7383P1 4 508 Terminal Board Supt. 194A7176P1 3 160 Vertical Lintel 68J210552BAXXXXXXB 1 553 LV Base 68J120132GE0000AAB 1 161 Bottom LV Lintel 149B3258P1 1 632 LV Door Latch Asm. 117B5064G3 1 162 Bottom HV Lintel 68J120125ET0000AAB 1 635 HV Door Late h Asm. 104B9336G2 2 163 LVMullion 174A8913G1 2 646 HV Door Vent Barrier NEMA 1 205A4475P1 1 164 Dust Shield NEMA 1 68J120125EU0000AAB 1 646 HV Door Vent Barrier NEMA 1A 68J 120134VR0000AAB 1 170 Wire Trouoh 68J 120125EB00OOAAB 1 653 LV Door Consult factorv 1 186 Coil Plug 169B7635G5 1 656 HV Door NEMA 1, 1A 68J210551 CAXXXXXXB 1 209 CPT Fuse Supt. 149B1782G4 2 656 HV Door NEMA 2, 12 68J220128KA0551 CBB 1 211 HV Bushing Male 161A8674P3 3 667 Door Hinge 147A4728G1 4 213 CPT Cable Clamp 104B9335P5 2 668 Hinge Pin 1459941P1 4 215 HV Bushing Female 167A8405P3 3 701 Upper Motor Cable Barrier 68J210553BDXXXXXXB 3 218 Handle Asm. 116C9928G* 0 1 702 Inc. Line Barrier Upper 68J210553BCXXXXXXB 1 250 Bus Insulation (Back Cover) 149B1741P1 1 703 Inc. Line Barrier Center 194A6922G1 1 268 Horz. & VB Asm. 116C9930G* f9 1 704 Inc. Line Barrier Lower 68J120125FM0000AAB 1 274 Main Bus Splice Consult factory 1 705 LV Base Barrier 68J120125FR0000AAB 1 275 Motor Terminal Asm. Uooer 149B1779G5 1 707 RH Rear Barrier Uooer 68J210553BAXXXXXXB 1 275 Motor Terminal Asm. Middle/lower 149B1779G6 1 708 RH Rear Barrier Center 68J 120125FD00OOAAB 1 289 Ground Bus 148B5352P* @) 1 709 RH Rear Barrier Lower 68J210553BBXXXXXXB 1 295 Ground Bus Splice Consult factory 1 710 CPT Fuse Compartment Horz. Barrier 68J 120125FFO000AAB 2 300 Back Ground Bus Strap 68J122220UV0000BB* 0 1 711 Bottom VB Barrier 194A6968P2 1 301 Ground Bus Strap Lower Left Side 68J122220UW0000BB* 0 1 720 Wire Harness Upper 7114R81G2V 1 302 Front Lower Ground Bus 68J122220UX0000BB* 0 1 720 Wire Harness Middle/Lower 7114R79G2V 1 303 Lower Vertical Ground Bus Connection 68J122220UY0000BB* 0 1 728 Contactor Latch Asm. 194A6949G1 1 304 Horz. Ground Bus 68J122220UZ00OOBB* 0 1 742 Shutter Asm. 116C9931G1 1 305 Upper Back Ground Bus Strap 68J122221 KA0000BB* 8 1 801 Fuse Supt. 194A7152G2 1 306 Ground Bus Spacer (Vertical Lintel! 68J122221KB00OOBB* 0 3 802 Fuse Suot. 194A7152G3 1 309 Motor Stab Asm. 116C9929G2 1 803 Power Fuse Ii) 3 310 Track & Barrier Asm. Upper/Middle 116C9939AAG3 1 850 Upper Ground Bus 68J122206DJ00OOBB* 0 1 310 Track & Barrier Asm. Lower 116C9939AAG2 1 851 Middle Ground Bus 68J122205UW0000BB* 0 1 315 Door Interlock Defeater 194A6916G1 1 852 Lower Ground Bus 68J122205UV0000BB* 0 1 500 Test Switch 10A CR104PSG21 B92 1 859 Bus Cover Plate 68J120125BMOO00AAB 2 500 Test Switch 20A 328A1141P1 1 860 Cont. Lift Truck 116C9918G4 1 0 See Tables 6 and 7. 0 Add suffix (*) per plating finish: @ See Table 16. N=no plating, TC=Silver, TB=Tin. @) See Table 18. See Figure 11 for motor ground bus detail. See panel data NP for fuse part number. ~ 0 0 r----------------7 ------~----JO 656 ~ @ ~o \0 0 r------------ -7 \s6 646 Jo 653 Figure 10. CR7160 Three-High Door Detail Figure 11. CR7160 'Three-High Motor Ground Bus Detail 9

Handle Assembly The non-load break isolating mechanism (handle assembly) is a complex construction requiring a special bench fixture to assemble and adjust the mechanical interlocking mechanisms. Therefore, we recommend the entire assembly be replaced if the handle mechanism becomes extensively damaged. Some parts of the handle assembly are replaceable and can be identified by part number as shown below: G) @ @ Entire assemblies are ordered by catalog number l l 6C9928G* (see Tables 6 and 7). The group number (G*) is found on an adhesive backed label stuck on the underside of the handle housing (see Figure 12). For G51, G52 and G55, order replacement assemblies Gl, G2 and G5 respectively. Entire assemblies can be ordered as follows: Table 6. CR7160 Air Break Handle Assemblies Full-voltage non-reversing Type of Starter Unit Reduced-voltage non-reversing Full-voltage reversing-standard Full-voltage reversing-mine hoist Reduced-voltage reversing Wye-delta Part winding-contactors in series Part winding-contactors in parallel Two-speed, one-winding Two-speed, two-winding Table 7. CR7160 Drawout Vacuum Handle Assemblies Full-voltage non-reversing Type of Starter Unit Reduced-voltage non-reversing Full-voltage reversing-sta nda rd Full-voltage reversing-mine hoist Reduced-voltage reversing Wye-delta Part winding-contactors in series Part winding-contactors in parallel Two-speed, one-winding Two-speed, two-winding Part Number 116C992861 116C992865 116C992862 116C9928G1 116C9928G2 116C9928G1 116C9928G1 116C992865 116C992862 116C992862 Part Number 116C992861 V 116C992865V 116C9928G2V 116C9928G1 V 116C992862V 116C992861 V 116C992861 V 116C9928G5V 116C9928G 2V 116C9928G 2V Figure 12. CR7160 Handle Assembly Table 8. CR7160 Handle Assembly Detail (see Figure 12) Figure Item Number Part Description Part Number 1 Brain Box 979B4446* 0 5 Test power interlocks with mounting bracket 205A5718G5 6 Control power interlocks l2nci 723B245G274 7 Contactor auxiliary interlock (1NO, lnc) 723B2456273 9 Sensor bar hook 194A7033P4 9 Weld nut assembly for hook 194A7033G1 15 Handle housing-standard 149B175961 15 Handle housing-if key interlocked 149B1759AAP1 16 Handle-standard 149B174661 16 Handle-if key interlocked 194A7179P1 22 Handle retainer clip N910P62C6 23 Depressor Finger 139B8558P4 24 Sensor Bar 139B855562 25 Carn 194A1491 Pl 0 * Group numbers for the 979B444 brain box are per starter type as follows: Full voltage non-reversing G12 Reduced-voltage non-reversing 614 Full-voltage reversing Reduced-voltage reversing Wye-delta 1 M contactor Wye-delta 2M contactor Part-winding contactors in series G13 G13 G12 G13 G12 Part-winding contactors in parallel 614 Two-speed, one-winding Two-speed, two-winding G13 G13 10

i I Limitamp Medium Voltage Motor Control ' One-High Horizontal Bus Table 9. CR7160 One,High Horizontal Bus Parts, Part Description Part Number Copper 1000A 104B9369P1* 0 Copper 2000A 104B9369P1* 0 41:1 Copperrnn Plated 1000A 104B9369P9* 0 Copperrnn Plated 2000A 104B9369P9* 0@} Copper/Silver Plated 1000A 104B9369P2* 0 Copper/Silver Plated 2000A 104B9369P2* 0 0 0 Consult factory for suffix (*) catalog number and for proper splice part numbers, @ Use QlY6, 908Bl01P8 spacers per section, @} Use QlY6, 908Bl01P21 spacers per section, 0 Use QlY6, 908Bl01Pl0 spacers per section, Vertical Bus CZ) A one-high vertical bus assembly consists primarily of the bus bars, shutter, and operator assembly all constructed as one item. The complete assembly is the easiest to replace;'howev-, er, if the user has. the expertise, the bare bus bar assembly can be installed in the field. The following table is a cross reference from the complete assembly group number,,l94a4480g*, to the bare bus bar assembly, 116C992_G_, shown in the following table..see identification sticker on the vertical bus assembly for the correct group number. Table 11. CR7160 One-High Vertical Bus Assembly Cross-Reference Complete Assembly Bare Bus Assembly 194A4480G16 0 116C9925G10 194A4480G24 @ 116C9925G 15 194A4480G25 @ 194A4480G34 0 194A4480G35 0 194A4480G36 0 194A4480G41 0 194A4480G42 194A4480G43 194A4480G44 194A4480G46 194A4480G47 116C9925G16 116C9925G25 116C9925G19 116C9925G20 116C9926G7 116C9925G26 116C9925G27 116C9925G30 116C9926G8 116C9926G9 0 For use with 700-ampere contactor. @ 1983 to current date-standard for 400-ampere contactor. Ground Bus Table 12. CR7160 One-High Ground Bus Parts Figure 13. CR7160 Vertical Bus Assembly Table 10. CR7160 One-High Vertical Bus Assembly Detail (see Figure 13) Figure Item Part Description Part Number Oty, Number 1 Front Vertical Bus Cover 116C9921 P5 1 2 Shutter Operator Pipe 139B8559G1 1 3A Contactor Operator Right Hand 169C6351ATG1 0 1 3B Contactor Operator Left Hand 169C6351ATG2 0 1 4 Shutter Bracket 194A6908P1 2 5 Shutter 149B1748P2 1 4,5 Shutter Assembly 149B1752G1 1 6 Holding Clamp 194A4466P1 2 8 Pipe Collar 181A4108P2 2 9 Bearing Plate 188A5537G1 2 10 Shutter Operator Bearing Support 139B8561G1 2 11A Shutter Operator Right Hand 149B1768G1 1 11B Shutter Operator Left Hand 149B1768G2 1 12 Bottom Vertical Bus Barrier 194A6968P2 1 13 MB Insulator (Not Shown) 157C8185P1 6 0 Previous part numbers l 49Bl 749Gl, G2, New parts must be ordered in pairs when replacing old parts. Part Description Part Number Copper 400A 104B9334P1* 0 Copper 600A 104B9334P12* 0 Copper/Tin Plated 400A 104B9334P19* 0 Copper{nn Plated 600A 104B9334P25* 0 Copper/Silver Plated 400A 104B9334P15* 0 Copper/Silver Plated 600A 104B9334P17* 0 0 Consult factory for suffix (*) catalog number and for proper splice part number. 11

Two-High Table 13. CR7160 Two-High Horizontal and Vertical Bus Parts Part Description Pait Number Copper 1000A 116C9952G19 0 Copper 2000A 116C9952G20 0 Coppermn Plated 1000A 116C9952G17 0 Coppermn Plated 2000A 116C9952G18 0 Copper/Silver Plated 1000A 116C9952G16 0 Copper/Silver Plated 2000A 116C9952G14 0 0 Consult factory for proper splice part numbers. Three-High Table 16. CR7160 Three-High Horizontal and Vertical Bus Parts Part Description Part Number Copper 1000A 116C9930G40 0 Copper 2000A 116C9930G41 0 Coppermn Plated 1000A 116C9930G38 0 Coooermn Plated 2000A 116C9930G39 0 Copper/Silver Plated 1000A 116C9930G3 0 Copper/Silver Plated 2000A 116C9930G4 0 0 Consult factory for proper splice part numbers. G) CD @ @---- --- Figure 14. CR7160 Two-High Bus Assembly -- @--- Figure 15. CR7160 Three-High Bus Assembly Table 14. CR7160 Two-High Bus Assembly Detail (see Figure 14) Figure Item Part Oescriplion Part Number (lty, Number 1 Top Vertical Bus Cover 116C9921P7 1 2 Stab and Molding Asm. 139B8559G2 1 3 Middle Vertical Bus Cover 194B6318P1 1 4 Bottom Vertical Bus Cover 116C9921P4 1 5 Bottom Vertical Bus Barrier 194A6968P2 1 8 Motor Stab Assembly 116C9929G2 1 9 Bus Insulator Barrier 233A2445P1 2 Table 17. CR7160 Three-High Bus Assembly Detail (see Figure 15) Figure llem Part Description Part Number (lty, Number 1 Top Vertical Bus Cover 116C9921P2 1 2 Stab and Molding Asm. 139B8559G2 1 3 Middle Vertical Bus Cover 116C9921 P3 1 4 Bottom Vertical Bus Cover 116C9921 P4 1 5 Bottom Vertical Bus Barrier 194A6968P2 1 8 Motor Stab Assembly 116C9929G2 1 9 Bus Insulator Barrier 233A2445P1 2 Table 15. CR7160 Two-High Ground Bus Parts Part Description Part Number Copper 400A 148B5352P4 0 Coooer600A 148B5352P21 0 Coppermn Plated 400A 148B5352P29 0 Coooermn Plated 600A 148B5352P28 0 Copper/Silver Plated 400A 14885352P11 0 Copper/Silver Plated 600A 148B5352P22 0 0 Consult factory for proper sphce part numbers. Table 18. CR7160 Three-High Ground Bus Parts Part Description Part Number Copper400A 148B5352P4 0 Coooer600A 148B5352P21 0 Coppermn Plated 400A 148B5352P29 0 Coppermn Plated 600A 148B5352P28 0 Copper/Silver Plated 400A 148B5352P11 0 Copper/Silver Plated 600A 148B5352P22 0 0 Consult factory for proper splice part numbers. 12

Limitamp Medium Voltage Motor Co11trol CPT Fuse Support Assemblies CPT primary fuse support assemblies are most easily identified by using the fuse catalog number, type ofenclosure ( one. high, two-high, three-high) and the matrix below. This will provide the complete fuse support assembly catalog number. Intermediate Stab and Track Assembly l 16C9939AAG2 and G3 Track assemblies are used in two- and three-high enclosures to support the contactor. This assembly includes the intermediate stabs. Table 19. CPT Fuse Support Assembly Part Numbers Enclosure Type Fuse Part One-High Two-High Three-High Number Qty. Part Number Qty. Part Number Qty. Part Number CSC#A480T1 E-1 1 55C682289G3 1 55C682289G3 1 149B1782G2 CSC#A480T2E 1 1 55C682289G3 1 55C682289G3 1 149B1782G4 CSC#A480T3E 1 1 55C682289G3 1 55C682289G3 1 194B6370G3 CSC#A4B0T5E 1 1 55C682289G3. - 9F60CCB007 1 104B9352G2. G) Figure 16. Intermediate Stab and 'frack Assembly Note: Group 2 assemblies are used in both two-high positions and in the bottom three-high position. Group 3 assemblies are used in the top and middle three-high positions only. Ground Finger assemblies for Group 3 tracks in older starters can be added to the new Group 3 tracks to make a complete replacement assembly. Ground finger assembly catalog number: 149Bl781G2. Table 20. Intermediate Stab and Track Assembly Parts (see Figure 16) Figure llem Pert Description Part Number Oty. Number 1 Track Frame 171B6050G1 1 2 Stab and Molding Assembly 169C6351 ASG1 1 3 Roller 245A7436P1 4 4 Barrier (not shown). Mounts on 194A6946P1 1 underside of G3 assembly only 13

These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or particular problems arise that are not covered sufficiently for the Purchaser's purposes, the matter should be referred to tl1e nearest GE sales office. GE GEF-4630A 0197 BL General Electric Company 41 Woodford Avenue, Plainville, CT 06062 1997 General Electric Company Electrical Distribution & Control