APPLICATION Directional cartridge valve type URED6 is intended for control direction of fluid flow, causing particular movement direction or stops a receiver (cylinder or hydraulic motor). The directional valve is mounted by screwing into a threaded cavity. The product is compliant with the regulations of directive 04/35/UE. Directional cartridge valve tight on both sides type URED6 3 NS6 up to 35 MPa up to 5 dm /min DATA SHEET - OPERATION MANUAL WK 493 30 06.07 DESCRIPTION OF OPERATION versions: URED6 C...;...C...M... URED6 C -/ M G4 Z4 M 3 4 5 URED6 C -/ M G4 Z4 version URED6 C5... 3 4 URED6 C5 -/ M G4 NZ4 The directional valve type URED6 comprises of solenoid (), sleeve (), poppet (3) and spring (4). Flow opening or closing is obtained by changing position of the poppet (3) inside the sleeve (). In version URED6C in neutral (current-free) position poppet (3) opens the flow. Flow closing occurs by supplying the solenoid () with the voltage and moving the poppet (3). Cutting off supply voltage causes return of the poppet (3) to its starting position by means of the spring (4) and opens the flow. Additionally in version URED6C M position of the poppet (3) can be monitored by inductive position sensor (5). In version URED6C5 in neutral (current-free) position poppet (3) closes the flow. Flow opening occurs by supplying the solenoid () with the voltage and moving the poppet (3). Cutting off supply voltage causes return of the poppet (3) to its starting position by means of the spring (4) and closes the flow. Type URED6 - - WK 49330 06.07
TECHNICAL DATA Hydraulic fluid mineral oil Required fluid cleanliness class ISO 4406 class 0/8/5 Nominal fluid viscosity o 37 mm /s at temperature 55 C Viscosity range Fluid temperature range (in a tank),8 up to 380 mm /s recommended o o 40 C up to 55 C max -0 C up to +70 C Ambient temperature range o o - 0 C up to +50 C Maximum operating pressure line 5 MPa line 35 MPa Power consumption 6 W Degree of pr otection IP 65 Weight 0,3 kg Spool position sensor* inductive sensor type M Type of position sensor sensor with two alternative outputs type PNP Supply voltage tolerance 4 V DC +0% -0% Maximum supply current of the solenoid I max 400 ma Type of connection external thread M x - 4 poles (pins) NOTE: (*) - available only for versions URED6C... INSTALLATION AND OPERATION REQUIREMENTS. Only fully functional and operational valve, properly connected to electrical installation must be used. Connecting or disconnecting the valve to an electrical installation must only be carried out by qualified personnel.. Ground connection ( ) must be connected with protective earth wire (PE ) in supply system according to appropriate instructions. 3. Solenoid plug shall precisely adhere to socket and shall be secured with thread bolt screwed in securely in a place. It is forbidden to operate the valve if the tightness and suitable clamp of cable in the plug gland are not ensured. 4. During the period of operation must be kept fluid viscosity acc. to requirements defined in this Data Sheet - Operation Manual 5. In order to ensure failure free and safe operation the following must be checked: condition of the electrical connection proper working of the valve cleanliness of the hydraulic fluid 6. Due to heating of solenoid coils to high temp., the valve shall be placed in such way to eliminate the risk of accidental contact with solenoid during operation or to apply suitable covers acc. to European standards PN - EN ISO 373 - and PN - EN 443 7. In order to ensure tightness of the directional valve block, one should take care of dimension of sealing rings, tightening torques and valve operation parameters given in this Data Sheet - Operation Manual 8. Valve with spool position sensor type M is adjusted at factory and it is not allowed to change its settings. In case of any damages of the sensor or valve one must change complete valve. Inductive sensors type M must not be connected serially. 9. A person that operates the directional valve must be thoroughly familiar with this Data Sheet - Operation Manual. WK 493 30 06.07 - - Type URED6
DIAGRAMS Hydraulic diagrams of valve type URED6... G version URED6C... version URED6C...M... version URED6C5... version URED6C5...N... Diagram of electrical connection of inductive sensor type M PNP 3 4 contact allocation (pins of switch connector) 3 4 Initial position of inductive sensor type M depending on the spool position A stroke 0 - off neutral state on output coctact - on state on output contact output state of sensor 0 0 pin 4 pin flow diagram for directional valve B B leaks A 0 flow Q Type URED6-3- WK 49330 06.07
PERFORMANCE CURVES measured at viscosity ν = 4 mm /s and temperature t = 50 C o Flow resistance curves,0 Pressure resistance p in relation to Q for directional cartridge valve type URED6... - versions: URED6C...;...C5......C...M...,6 p [MPa], 0,8 0,4 0 6 8 4 30 Q [dm 3/min] Operating limits curves characteristic curves p - Q for directional cartridge valve type URED6C...; flow direction:...c...;...c...m......c...;...c...m... characteristic curves p - Q for directional cartridge valve type URED6C5...; flow direction: 30 30 0 0 p [MPa] 5 0 p [MPa] 5 0 5 5 0 4 8 6 0 5 Q [dm 3/min] 0 5 0 5 0 5 30 Q [dm 3/min] WK 493 30 06.07-4- Type URED6
OVERALL AND CONNECTION DIMENSIONS versions: URED6C...M...;...C...M...M...;...C5...M... 5 4 0 M x 5 O35 O39 54 6 5 0 O6,5 M x,5 3 5 S7 6 9 7 8 7,5 8 47,5 tightening torque Md = 50-55 Nm WARNING: valve version URED6C M M with spool position sensor type M is adjusted at factory and it is not allowed to change its settings. In case of any damages of the sensor or valve one must change complete valve inductive sensors type M must not be connected serially - Sealing o-ring 8 x,65 - pc/set - Sealing o-ring 5,6 x,78 - pc/set 3 - Back-up ring 9 x 6, x 0,7 - pcs/set 4 - Plug-in connector type ISO 4400 (DIN 43650 - A) 5 - Plug-in connector type ISO 4400 (DIN 43650 - A) with rectifier 6 - Overall dimensions * - versions: URED6C...M...;...C5...M... 7 - Overall dimensions ** - versions: URED6C...M...M... 8 - Inductive spool position sensor (plug-in connectors not shown on drawing, must be ordered separately acc. to data sheet WK 499 963 - coding 476-0058990) 9 - Manual override (only version URED6C5...M...) 0 - Space required to remove the plug-in connectors - item 4, 5 NOTES: (*) - Additional space to remove the coil ~ 50 mm (**) - Additional space for sensor plug - item 8 and electrical wire ~ 70 mm Type URED6-5 - WK 49330 06.07
OVERALL AND CONNECTION DIMENSIONS versions: URED6C...U...;...C...U...M...;...C5...U... 5 4 0 5 5 M x 54 6 O6,5 0 O39 O35 7/8-4UNF - A S7 3 5 6 9 7 8 7,5 8 47,5 tightening torque Md = 50-55 Nm WARNING: valve version URED6C U M with spool position sensor type M is adjusted at factory and it is not allowed to change its settings. In case of any damages of the sensor or valve one must change complete valve inductive sensors type M must not be connected serially - Sealing o-ring 8 x,65 - pc/set - Sealing o-ring 5,6 x,78 - pc/set 3 - Back-up ring 5,9 x 3 x,4 - pcs/set 4 - Plug-in connector type ISO 4400 (DIN 43650 - A) 5 - Plug-in connector type ISO 4400 (DIN 43650 - A) with rectifier 6 - Overall dimensions * - versions: URED6C...U...;...C5...U... 7 - Overall dimensions ** - versions: URED6C...U...M... 8 - Inductive spool position sensor (plug-in connectors not shown on drawing, must be ordered separately acc. to data sheet WK 499 963 - coding 476-0058990) 9 - Manual override (only version URED6C5...U...) 0 - Space required to remove the plug-in connectors - item 4, 5 NOTES: (*) - Additional space to remove the coil ~ 50 mm (**) - Additional space for sensor plug - item 8 and electrical wire ~ 70 mm WK 493 30 06.07-6 - Type URED6
OVERALL AND CONNECTION DIMENSIONS version URED6C5...M3... 5 4 8 O4 M0 x,5 O36 54 5 6 5 3 S7 5 6 5 85* 7 tightening torque Md = 5-30 Nm - Sealing o-ring 7 x - pc/set - Sealing o-ring,4 x,78 - pc/set 3 - Back-up ring PTFE 5 x,3 x,4 - pcs/set 4 - Plug-in connector type ISO 4400 (DIN 43650 - A) 5 - Plug-in connector type ISO 4400 (DIN 43650 - A) with rectifier 6 - Overall dimension* 7 - Manual override 8 - Space required to remove the plug-in connectors - item 4, 5 NOTES: (*) - Additional space to remove the coil ~ 50 mm Type URED6-7 - WK 49330 06.07
OVERALL AND CONNECTION DIMENSIONS versions: URED6C...M...;...C...M...M...;...C5...M... cavity M - 06 - (M x,5; -way) ao tightening torque Md = 50-55 Nm 0,05 - refers to all diameters of the main hole and chamfers 0,5 (min) * 3 A O8 (min) O M x,5 9 +0,05 0 A,5 O9,5 (min) O7 (max) NOTE: (*) - Max depth of the counterbore - 4,9,5 3,3 ±0, n 0,05 A 5 33 3,5 30 O9,5 (max) 0,5-45v detail A,5 O9,5 (max) <O8 O (min)> 3 +0,5 0,5 R 0, 45 WK 493 30 06.07-8 - Type URED6
OVERALL AND CONNECTION DIMENSIONS versions: URED6C...U...;...C...U...M...;...C5...U... cavity U - 06 - (7/ 8-4UNF - B; -way) 33,3 +0,5 5,3 +0,4 3,7 +0,4 0,5 (min) * 6 + A ao tightening torque Md = 50-55 Nm 0,05 - refers to all diameters of the main hole and O chamfers 3 (min) 4 ±0,05 O O 7/8-4UNF -B 5,87 +0,05 A,5 n 0,05 A,5 (min**) 3,6 (max**),5 30 detail A,5 +0,4,5,5 5 <O3 (min)>,5 R 0,5 O4,5 (max**) NOTES: (*) - Max depth of the counterbore - 4,9 (**) - Diameter of ports, located on circuit within specified limit dimensions - min φ6,5 45 WK 493 30 06.07-9 - Type URED6
OVERALL AND CONNECTION DIMENSIONS version URED6C5...M3... special cavity M0 x,5 tightening torque Md = 5-30 Nm 60 O5 8 (min) 6 + adjusting depth 4,5 +0,,5 (min) (min) * A,5 M0 x,5 O5H8 A,5 ^ 0,05 A n 0, A,5 O6 (max) 3 O5 (max) detail A 30vuv,5 ^ 0, A O,3+0, NOTE: (*) - Max depth of the counterbore - 4,9 R0,4 max 3 +0,4 R0, - 0, 45 WK 493 30 06.07-0 - Type URED6
HOW TO ORDER Number of service ports -way = URED 6 Nominal size(ns) NS6 = 6 Spool symbol (spool diagrams acc. to page 3) spool C = C spool C5 =C5 Series number (-9) - connection and installation dimensions unchanged = X series = Number of working positions -position valve = Type of connection cavity M x,5 = M cavity M0 x,5* = M3 cavity 7/8-4 UNF-B = U NOTE: (*) - option available only for version URED6C5... * Control voltage for solenoids V DC = G 4V DC =G4 0V DC = G0 0V AC 50Hz (plug-in connector with rectifier) = W0R 30V AC 50Hz (plug-in connector with rectifier) = W30R Manual override solenoids without manual override solenoids with manual override* NOTE: (*) - option available only for version URED6C5... = no designation = N Electrical connection plug-in connector type ISO 4400 (DIN 43650 - A) without LED =Z4 plug-in connector type ISO 4400 with LED = Z4L Spool position sensor without spool position sensor with spool position sensor M* NOTE: (*) - option available only for version URED6C... Sealing NBR (for fluids on mineral oil base) FKM (for fluids on phosphate ester base) = no designation = M = no designation = V Further requirements in clear text (to be agreed with the manufacturer) NOTES: Directional cartridge valve should be ordered according to the above coding. The symbols in bold are preferred versions in short delivery time. Coding example: URED6 C5 -/ M G4 Z4 Type URED6 - - WK 49330 06.07
Special execution version URED6C5... - SO 478 APPLICATION, DESCRIPTION OF OPERATION, TECHNICAL DATA, DIAGRAMS, PERFORMANCE CURVES, CAVITY DIMENSIONS as in standard version - acc. to page to 4; page 8. OVERALL AND CONNECTION DIMENSIONS version URED6C5... - SO 478 5 4 3 O6,5 Mx,5 O 45 58 S7 5 30 tightening torque Md = 50-55 Nm 06 - Solenoid with plug-in cavity type MS3E-3P (producer SOURIAU) - Plug-in connector type MS36E-3S (producer SOURIAU) 3 - Manual override 4 - Sealing o-ring 8 x,65 5 - Sealing o-ring 5,6 x,78 WK 493 30 06.07 - - Type URED6
HOW TO ORDER URED 6 C5 M G4 N S SO 478 Number of service ports -way = Nominal size(ns) NS6 = 6 Spool symbol (spool diagrams acc. to page 3) spool C5 = C5 Series number (0-9) - connection and installation dimensions unchanged = X series = Number of working positions -position valve = Type of connection cavity M x,5 Control voltage for solenoids 4V DC = M = G4 Manual override solenoid with manual override Electrical connection special execution plug-in connector type MS3E- -3P (SOURIAU) = N = S Sealing NBR (for fluids on mineral oil base) = no designation FKM (for fluids on phosphate ester base) = V Special execution version with special plug-in connector and swinging clamp of manual override = SO 478 NOTES: Directional cartridge valve should be ordered according to the above coding. Coding example: URED6 C5 -/ M G4 N S - SO 478 Type URED6-3 - WK 49330 06.07
Special execution version URED6C5... - SO 495 APPLICATION, DESCRIPTION OF OPERATION, TECHNICAL DATA, DIAGRAMS, PERFORMANCE CURVES, CAVITY DIMENSIONS as in standard version - acc. to page to 4; page 9 OVERALL AND CONNECTION DIMENSIONS version URED6C5... - SO 495 5 4 3 7/8-4UNF -A O36 55 u 33 5 S7 9 u tightening torque Md = 50-55 Nm - Solenoid with swinging clamp of manual override - Manual override 3 - Plug-in connector type ISO 4400 (DIN 43650 - A) without LED 4 - Sealing o-ring 8 x,65 5 - Sealing o-ring,4 x,78 WK 493 30 06.07-4 - Type URED6
HOW TO ORDER URED 6 C5 U G4 N Z4 SO 495 Number of service ports -way = Nominal size(ns) NS6 = 6 Spool symbol (spool diagrams acc. to page 3) spool C5 = C5 Series number (0-9) - connection and installation dimensions unchanged = X series = Number of working positions -position valve = Type of connection cavity 7/8-4 UNF-B Control voltage for solenoids 4V DC = U = G4 Manual override solenoid with manual override Electrical connection plug-in connector type ISO 4400 (DIN 43650 - A) without LED = N = Z4 Sealing NBR (for fluids on mineral oil base) = no designation FKM (for fluids on phosphate ester base) = V Lockable manual override version with swinging clamp of manual override = SO 495 NOTES: Directional cartridge valve should be ordered according to the above coding. Coding example: URED6 C5 -/ U G4 N Z4 - SO 495 Type URED6-5 - WK 49330 06.07