INDEX Bustrunking System Standard & Specifications Technical Parameters Copper Aluminum Components

Similar documents
Busbar Trunking System. C&S Electric Ltd.

WavePro LT Busway Cost effective solution for electrical distribution

HIGH POWERBAR COPPER UL857

MR - MEDIUM RATING A

POWERFLOW. Your Idea System! Series. Series BUSWAY BUSBAR TRUNKING SYSTEM 630A 6300A ELECTRIC COMPAC ELECTRIC COMPAC ELECTRIC MAN. CO., LTD.

NB1 Miniature Circuit Breaker

Leading Solution & Customer Value. Series Busway SA 8000 ISO 9001 ISO OHSAS 18001

LSC Bus Way System [Ex/Ez/Ef-Way TM ]

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Busway Construction. Bus Bars

HX Range Catalogue. Contact. About Anord Mardix.

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES


ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

Gas Insulated Switchgear

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Key features. DESIGNS: - Conservator type - Hermetically sealed

CAST RESIN BAR IP68 BUSBAR SYSTEM

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

BUSWAY Low Voltage (Pow-R-Flex)

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Low Voltage Main Distribution Board

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS

UniGear. Technical Guide

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

NXPLUS C Single busbar. Maintenance-free for lifetime

LECTRO Bus Way System. [Series LSB II / 300A A]

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

ATX DPD Series Distribution Panelboards Flameproof

S H A D E S ELECTRICAL DB MANUFATURING

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Fuse switch disconnectors

INTELLIGENT MEDIUM POWERBAR

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

RAPIER DSB Disconnectors

(Under Two Part Bid System) Tender No: NFV/ PUR/ BEC K for VCB

Miniature Circuit Breaker

Euroload Changeover Switch

vertical fuse switch disconnectors

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Wall mounted switchgear

15 kv and 25 kv Thru-Bushings

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

with Vacuum Circuit Breaker HAF

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

SECTION PANELBOARDS

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

DX³ RCCBs - ID 4P up to 100 A

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

COMPACT SUBSTATION GUIDE

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

BUSBAR TRUNKING SYSTEMS a

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

Product Specification

Sentron Low Amp Busway System

Distribution Blocks & Bus-bar Solutions

Vistop TM isolating switches 63 to 160A

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

GE Consumer & Industrial

B kv Gas-insulated Substations

Changeover & Bypass Sw it ches

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

TECHNICAL SPECIFICATIONS OF PCC PANEL

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Medium Voltage Metal-Enclosed Switches

XL Distribution enclosures WORKSHOP SPECIFICATIONS

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

KAP A Plug-in Busbar Distribution System IEC ME 04

25 kv Apparatus Bushings

ype UP T Busplugs Low Voltage Switchboard Equipment

Elimsan High Voltage Disconnectors

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

Transcription:

INDEX Bustrunking System.. (1) Standard & Specifications.. (2) Technical Parameters Copper.. (3-4) Aluminum.. (5-6) Components Straight Length (Feeder & Plug in type).. (7) Uniblock Joint, Edge Elbow & Offset Edge Elbow.. (8) Flat Elbow, Offset Flat Elbow & Flat Tee.. (9) Flanged End.. (10) Flange End with Flat Elbow &.. (11) Flange End with Edge Elbow.. (11) Flange End Box & Flange Bellow.. (12) Reducer & Sectional Isolator.. (13) Center Feed Unit & Copper Flexible.. (14) End Feed & End Cover.. (15) Vertical Support & Vertical Rigid Hanger.. (16) Vertical Spring Hanger.. (17) Horizontal Support.. (18) Plug in box.. (19) Domestic References.. ( ) International References.. ( ) Installation References.. ( ) Certificates.. ( ) 1

GENERAL GENERAL Busbar Trunking System for electrical distribution is an alternative to cumbersome conventional cable distribution system. Busbar Trunking System has the advantage of expansions, Changes, replacement and reusing capability in the future. Loads can be fed from Plug-in Box unlike cables, where each floor/ machine is to be fed separately from the main switchboard. Repositioning of distribution points is simpler. Installation time is much shorter then cable system. This provides low installation and manpower costs and help for better time management. Busbar Trunking systems have a modern and aesthetic look. System is maintenance free. SALIENT FEATURES Close proximity of busbars reduces inductive reactance, resistance, impedance and voltage drop is much lower than cable & any other busbar system. Specially designed housing act as a heat sink to yield improved thermal characteristic, high mechanical and short circuit strength. Busbar System has no chimney effect, hence provide a better resistance to the spread of fire. Automatic polarity is maintained during installation. System can be mounted edgewise OR flat wise horizontally or vertically in any direction with all kinds of bends and tees etc. The compact structure and steel housing allows much lower electromagnetic field around busbar system then cable.busbars does not generate electromagnetic. 2

SPECIFICATIONS Compliance of Standard Independent Certification Authority Busbar Arrangement Busbar Ratings Busbar Configuration Rated Operational Voltage (Ue) Rated Insulation Voltage (Ui) Rated Dielectric Voltage Rated Impulse Withstand Voltage (Uimp) Rated Frequency Enclosure Material Surface Coating on Enclosure Busbar Material (Phase/Neutral) Busbar Material (Internal Earth) Busbar Material (External Earth) Busbar Insulation Degree of Protection Joint Plug -in-box IEC 60439 (1&2) & IS 8623 (1&2) VMtec - Germany Sandwich Type Copper 630 ~ 6600A Aluminium 400 ~ 5000A 3 Phase+50% Internal Earth 3 Phase+100% Neutral+50% Internal Earth 3 Phase+200% Neutral+50% Internal Earth 3 Phase+100%Neutral+100% Isolated Earth +50%Internal Earth 1000 Volt, AC 1000 Volt, AC 3.5 KV r.m.s 12 kv (1.2/50 μs) 50 Hz / 60 Hz 1.6mm G.I Epoxy polyster powder coated (RAL-7032) Copper (full round edge ),99.9% pure ETP grade Aluminium (full round edge), 99.5% pure. G.I 1.5mm / Copper 1.5 mm. Copper / Aluminium Multi layer Class- 'F' Insulation (Polyster +Mica) IP 54 for Plug in type. IP55 / IP65 / IP67 for feeder bustrunking. Uniblock Joint (With Isolation and tamper proof shear off nut) 32~800 A 3

TECHNICAL PARAMETRS SBC (Copper Sandwich Insulated Bus Trunking) 151 151 172 172 3 Phase+50% Internal Earth 3 Phase+100% Neutral +50% Internal Earth 3 Phase+200% Neutral +50% Internal Earth 3 Phase+100% Neutral+100% Isolated Earth+50% Internal Earth 4

TECHNICAL PARAMETRS Voltage Drop Calculation Formulae ΔV = k x 3 x ( Rt cos Ø + X sin Ø ) x IB x L Where ΔV is the composite voltage drop of the system (V); Rt & X are the mean resistance and reactance values of the system ("/m); IB is the actual load current of the circuit being considered (A); L is the length of the system being considered (M); Cos Ø is the load power factor being considered; k is the load distribution factor. k=1, if full load is concentred at the end of the busbar trunking run; k=(n+1)/2n, if the load is uniformly spread between n branches. 5

TECHNICAL PARAMETRS SBA (Aluminium Sandwich Insulated Bus Trunking) 151 151 172 172 3 Phase+50% Internal Earth 3 Phase+100% Neutral +50% Internal Earth 3 Phase+200% Neutral +50% Internal Earth 3 Phase+100% Neutral+100% Isolated Earth+50% Internal Earth 6

TECHNICAL PARAMETRS Voltage Drop Calculation Formulae ΔV = k x 3 x ( Rt cos Ø + X sin Ø ) x IB x L Where ΔV is the composite voltage drop of the system (V); Rt & X are the mean resistance and reactance values of the system ("/m); IB is the actual load current of the circuit being considered (A); L is the length of the system being considered (M); Cos Ø is the load power factor being considered; k is the load distribution factor. k=1, if full load is concentred at the end of the busbar trunking run; k=(n+1)/2n, if the load is uniformly spread between n branches. 7

Straigth Length (Feeder) Transformer to Panel. Panel to Panel. Generator to Panel. Panel to Rising mains. Length of Bustrunking (L) Length of Bustrunking (L) Length of Bustrunking (L) Standard & Max. Length: 3000mm. Mini. Length: 450mm. Straigth Length (PIP) For tapping Power from Main Line through Plug-in-Boxes. Plug-in point shown are indicative only. Rating and number of Plug-in -Point shall be as per the site requirement (up to 5 Nos max on either side). Two type of Plug-in Points(PIP): (32~400A) & (500 ~800A) can be provided as per requirement. Length of Bustrunking (L) Length of Bustrunking (L) Standard & Max. Length: 3000mm. 8

Uniblock Joint Joint can be fitted / removed in installed condition without removal of section. Heavy duty disc spring used on both sides for unifrom distribution of pressure. Joint can be tightened easily with help of spanner on nut side only.(spanner not required on bolt head side) Shear off nut ensure tightness of joint at desired torque and eliminates the need of torque wrench during installation. Tamper proof cap over shear off nut prevents opening of nut after achieving desired torque. Nut can only be opened after breaking the cap. Shear off nut Edge Elbow Copper 630~6600A Aluminum 400~5000A Standard & Mini. Dimn.AxB (mm) 300 x 300 Offset Edge Elbow Copper 630~6600A Aluminum 400~5000A Standard & Mini. Dimn.AxBxC (mm) 300 x 300 x 300 9

Flat Elbow Aluminum 4000~5000A Copper 6000~6600A Aluminum 2000~3600A Copper 3200~5000A Aluminum 400~1800A Copper 630~2500A Standard & Mini. Dimn. AxB (mm) 400 x 400 500 x 500 600 x 600 COMPONENTS Offset Flat Elbow Aluminum 4000~5000A Copper 6000~6600A Aluminum 2000~3600A Copper 3200~5000A Aluminum 400~1800A Copper 630~2500A Standard & Mini. Dimn. AxBxC (mm) 400 x 400 x 400 500 x 500 x 600 600 x 600 x 600 Flat Tee Aluminum 4000~5000A Copper 6000~6600A Aluminum 2000~3600A Copper 3200~5000A Aluminum 400~1800A Copper 630~2500A Standard & Mini. Dimn. AxBxC (mm) 400 x 400 x 400 500 x 500 x 600 600 x 600 x 600 10

Flanged End 300 Std. & Mini BUSBAR WIDTH BUSBAR WIDTH BUSBAR WIDTH BUSBAR WIDTH 40 ~ 80mm 100 ~ 125mm 150 ~ 175mm 200 ~ 230mm TERMINATION HOLES Ø14) AS PER REQUIREMENT TERMINATION HOLES Ø14) AS PER REQUIREMENT Flanged End cut out & Drilling 11

Flanged End with Flat Elbow Aluminum 4000~5000A Copper 6000~6600A Aluminum 2000~3600A Copper 3200~5000A Aluminum 400~1800A Copper 630~2500A Standard & Mini. Dimn. A x B (mm) 275 x 400 375 x 500 475 x 600 Flanged End with Edge Elbow Standard & Mini. Dimn. A x B (mm) Copper 630~6600A Aluminum 400~5000A 175 x 300 12

Flanged End Box S.NO STANDARD DIMENSIONS Aluminum 4000~5000A Copper 6000~6600A Aluminum 2000~3600A Copper 3200~5000A Aluminum 1350~1800A Copper 1800~2500A 700 Aluminum 400~1250A Copper 630~1600A 700 800 Flange Bellow Flange Bellow need to be fixed between Flanged End Box and Genset termination box to avoid impact of vibrations of Genset being transferred to bustrunking. S. No Copper 630~1600A Aluminum 400~1250A Copper 1800~2500A Aluminum 1350~1800A Standard Dimensions Code S. No Copper 3200~5000A Aluminum 2000~3600A Code SFBE-3 S. No Copper 6000~6600A Aluminum 4000~5000A Code SFBE-4 13

Reducer These are required to connect two dissimilar rating of bustrunking. Reducer may be designed with switching or isolating device. Reducer (Direct) Reducer (Switchgear) Sectional Isolator These are required to isolate the bustrunking run in between, for various reasons. Section Isolator Unit can be fitted with load Break Switches / SFU's / MCCB's. 14

Center Feed Unit To charge bustrunking through cables from middle of bustrunking. Center feed Unit is available with sufficient space for direct connection through lugs and bolts. MCCB,SFU, lsolators, fuse holders etc. can be fitted in Center Feed Unit as per requirement. Undrilled cable gland plate is provided at bottom for multiple cable entry. Center Feed Unit (Direct) Center Feed Unit (Switchgear) Copper Flexible Copper Flexible need to be used to connect flanged end busbar with busbars (Terminals) of Panel / Transformer / Generators. Holes to be drilled at site as per requirement Bustrunking side Tin Plated Braided Flexible Switchgear side (Panel/D.G/TFR.) Thickness (t) & No of flexible as per Rating 15

End Feed To charge bustrunking through cables from one end of bustrunking. End feed is available with sufficient space for direct connection through lugs and bolts. MCCB,SFU, lsolators, fuse holders etc. can be fitted in End Feed as per requirement. 300 mm length of bustrunking is integrally fitted (measured with bustrunking) along with End Feed as standard practice so that joint between End Feed and bustrunking is exactly same as joint of two normal bustrunking lengths. Undrilled cable gland plate is provided at bottom for multiple cable entry. End Cover It is used to terminate and to protect the end of plug-in bustrunking (Rising mains run.) It can be remove easily for extension of bustrunking. End End Feed (Direct) End Feed (Switchgear) End Cover It is used to terminate and to protect the end of plug-in bustrunking (Rising mains run.) It can be remove easily for extension of bustrunking. 16

Vertical Support Vertical support is used to control Horizontal movement of sandwich rising main. Vertical Rigid Hanger One set of Rigid hanger per rising main must be installed at the start of the rising mains (i.e. At the lowest floor ) to prevent expansion of bustrunking in downward direction.these can be fitted on 100x50X5 (or equivalent) channels mounted on floor / wall as shown below (not in scope of VMtec supply) Recommendation for using hangers per floor:- Up to 3.5 M: 01 rigid hanger. 3.5M >4.5 M: 01 rigid hanger + 01 Vertical support. (for ensuring vertical alignment of rising mains.) 4.5 m > 6.0 M: 02 rigid hanger Hanger support Rigid hanger Bolt C-Channel With Ø14 holes not in scope of VMtec Supply(100x50x5) Copper 630A~1250A Aluminum 400A~1800A Copper 1600A~ 2500A Aluminum 2000A~ 5000A Copper 3200A ~ 5000A Installation Sequence Remove Nut A from Rigid Hanger on both sides. Mount " Hanger Support" through 2Nos. Ø 13 predrilled holes provided on desired rising main section. Insert "Rigid hanger bolts" into C-channel (already fixed at the floor level with desired holes) Adjust Nut B on to the C-channel (on both sides parallely) ensuring center line ( ) of rigid hanger support positioned as 175 mm from floor level (or as indicated in drawing ) Tighten & lock nut A. Ensure nut C remains fully tightened during entire process. 17

Vertical Spring Hanger sustain the bustrunking load and to allow vertical expansion of bustrunking in upward direction below (not in scope of VMtec supply) Up to 3.5 M: 01 Vertical spring hanger. 3.5M >4.5 M: 01 Vertical spring hanger + 01 Vertical support. ((for ensuring vertical alignment of rising mains.) 4.5 M > 6.0 M: 02 Vertical spring hanger. Nut D Nut C1 Nut C2 325 300 175 325 300 175 325 300 175 Nut B Nut А 100 100 215 100 C-Channel With Ø14 holes not in scope of VMtec Supply(100x50x5) 107.5 107.5 SVSH-1 SVSH-2 SVSH-3 Instalation Sequense Remove nut A from spring hanger on both sides. Mount " Hanger support" through 2 Nos. Ø13 predrilled holes provided on desired Rising main section. Adjust nut B on to the C-Channel ensuring center line ( ) of Hanger Support positioned at 300 open & bring down nut C1 & C2 slowly (on both sides parallely) until a gap of 1~2mm is created between nut D and spring hanger support Lock nut C1 & C2 at this position Loosen Nut D for allowing thermal expansion of rising main. 18

Edgewise Horizontal Support These support need to be provided on horizontal feeder run at an interval of 1.5 M (or as per site requirement) Ø12 Rod * Ø12 Rod * Ø12 Rod * 250 300 250 300 250 300 (SEHS-1) (SEHS-1) (SEHS-1) * Not in scope of VMtec Supply Flatwise Horizontal Support These support need to be provided on horizontal feeder run at an interval of 1.5 M (or as per site requirement) Ø12 Rod * Ø12 Rod 12 Rod * A A A Standard Dimensions A B Code Detail 250 400 650 850 300 450 700 900 SFHS-1 SFHS-2 SFHS-3 SFHS-4 * Not in scope of VMtec Supply 19

Plug-in-Box Plug in box enclosure is made from G.I with side hinged door. Plug in contacts are made out of silver plated copper with spring steel backup pressure clips for ensuring uniform pressure and low contact resistance. For cables entry, provision of gland plates are provided on both sides and bottom of Plug in Box. Earth contact of Plug-in boxes makes first & breaks last. Plug in box are suitable for MCCB/SFU s with rotary handle and door interlocking. Plug in boxes are available with Interlocking with bustrunking to ensure "plug-in" and "Plug-Out" possible only in "Off" Condition. Silver Plated contacts are properly shrouded / isolated. Plug in box up to 400 A are compatible to all ratings of Bustrunking with 400 A Plug-in-points Plug in box from 500A to 800 A are compatible to all ratings of Bustrunking with 800 A plug in points. Plug in boxes can only be fitted on to the Bustrunking with corrected polarity i.e. ENRYBE. Fig.-1 Fig.-2 Fig.-3 Fig.-4 * Available with Isolater. PIB with subcode 4B is applicable for- 3 Phase+50% Internal Earth 3 Phase+200% Neutral +50% Internal Earth 3 Phase+100% Neutral +50% Internal Earth 3 Phase+100% Neutral+100% Isolated Earth+50% Internal Earth 20