A 1.2 kv class externally removable secondary bushing

Similar documents
100 A externally operated one-, twoand three-phase tap-changer switch

Two-position sidewall (horizontal) and cover (vertical) mounted loadbreak switches

Eaton s Cooper Power Systems

200 A and 600 A, 15, 25, and 35 kv junction bars for separable connectors

25 kv class fused loadbreak elbow connector

600 A 15 kv class T-OP II deadbreak connector

600 A 15 and 25 kv class deadbreak accessories, tools, and replacement parts

K-Limiter high ampere Companion II fuse

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

600 A 35 kv class separable splices

600 A 28 kv class Cleer loadbreak connector system

600 A 35 kv class deadbreak accessories, tools, and replacement parts

600 A 25 kv class BT-TAP deadbreak connector

High-voltage primary bushings installation instructions

Effective March 2015 Supersedes S August 2012

Edison modular fuse, vault application products

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

Direct-connected capacitor fuse

600 A 15 kv class Cleer loadbreak connector system

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

600 A 35 kv class BT-TAP deadbreak connector

X-Limiter full-range current-limiting fuse

Single-Phase Step Voltage Regulators

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

Single-phase step voltage regulators

M-Force three-phase switch

600 A 15 and 25 kv class Cleer grounding elbow

Single-phase pad-mounted step voltage regulator

INSTALLATION PRODUCTION TESTS

NX indoor current-limiting fuses

ELF -LR current-limiting fuse

UltraSIL polymer-housed VariSTAR station-class surge arresters

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

Type MOST oil switch

M-Force three-phase switch

Grounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

Technical specifications for 10 ka, heavy-duty class 1, 3 kv and 3.33 kv VariSTAR MOV disks

Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks

D-73P disconnect and bypass switches

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)

Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

Loadbreak Apparatus Connectors

CM52 Network protector

COOPER POWER CA280012EN

1500 kva Padmount Transformer delta Primary Voltage 208Y/120 Secondary Voltage

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

CMU medium voltage power fuses

Eaton s Cooper Power Systems catalog Medium-voltage vacuum circuit breakers

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

Low voltage bushings for pad-mounted distribution transformers Technical information guide

Underground Distribution Switchgear

Figure 1. Two and Three-phase MagneX.

CCFL Transformers Cold cathode fluorescent lamp inverter transformers

BH-1 modular fuse blocks, 700 V, 400 A

ABB Power T&D Company Inc. General Information: DT-100 DT-150 DV-100 DV-150. De-energized Switches TPL , July 1999, Page 1 of 4

NOVA three-phase, microprocessorcontrolled

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

GROUP C. Apparatus Bushing.

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

GENERAL. CONSTRUCTION External

Molded Current-Limiting Fuse

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Effective October 2017 Supersedes July 2014 (280-40)

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

PT Medium voltage fuses for potential and small power transformers

Substation Transformers

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Medium Voltage Metal-Enclosed Switches

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Transcription:

OEM Equipment Catalog Data CA800018EN Supersedes July 2015 COOPER POWER SERIES 3010-4515 A 1.2 kv class externally removable secondary bushing General Eaton s Cooper Power series 3010-4515 A externally removable secondary bushings are used for connecting cables outside of pad-mounted transformer tanks to the secondary coil winding leads inside the tanks. The 3010 A secondary bushings are offered as inline and 90 internal spade versions, 4515 A secondary bushings are offered as inline only. They are designed for use in transformer oil, Envirotemp FR3 fluid, or an approved equivalent. They are externally clamped for sidewall mounting through a 3.06-inch diameter hole. The bushings are designed for use inside cubicles only. All metallic parts of the bushings are tin plated for more efficient current interchange. The sealing gasket is contained by the molded body for controlled compression, ensuring an effective seal. The bushing clamp is made of an aluminum alloy to provide strength for maintaining even gasket pressure under heavy loads. All bushings are supplied with a threaded support bracket hole on the end of the external spade. Installation Four clamp studs must be welded around the bushing hole. Install the gasket over the bushing shank onto the gasket surface. Insert the bushing through the tank hole and place the bushing clamp over the welded tank studs. Install a plated lock washer and nut onto each stud and tighten. Connect the internal secondary transformer leads to the internal spade. Refer to Service Catalog Section S800-16-1 for installation instructions.

Catalog Data CA800018EN 3010-4515 A 1.2 kv class externally removable secondary bushing 3/8-16 UNC-2B A QTY. Ø.56 (14.22 mm) hole (44.45 mm) 1.87 (47.5 mm) Ø 2.87 /(72.9 mm) TO FIT Ø 3.06 /(77.7 mm) TANK HOLE (44.45 mm) 4.00 (101.6 mm) (44.45 mm) (44.45 mm) 1.25 (31.75 mm) B C 1.50 (38.10 mm) D Ø 5.25 (133.35 mm) 4.23 (107.49 mm) Ø 405 (10.30 mm) hole 2.7 (68.58 mm) Figure 1. Line illustration of a 3010 A secondary bushing (inline) with dimensional information. Note: Dimensions given are for reference only. Table 1. Voltage Ratings and Characteristics Description kv Standard Voltage Class 1.2-2.5 AC 60 Hz 1 Minute Withstand 15 BIL and Full Wave Crest 45 Table 2. Current Ratings and Characteristics Description Amperes Continuous Aluminum Bushing 2780-3010 A rms Copper Bushing 3610-4515 A rms Current ratings and characteristics are in accordance with IEEE Std C57.12-1993 standard. Ordering information - 3010 A secondary bushing - inline To order a 3010 A secondary bushing, specify the catalog number as listed in Table 3. (Gasket and clamp must be ordered separately, see Table 6.) Table 3. Secondary Bushing Dimensional Information - Inline Catalog Number 2690131D01 6 2690131D04 12 2690131D06 16 2690131D07 20 External * Quantity of Holes Dimensions in. /(mm) A B C D 6.28 10.76 17.30 (159.51) (273.30) (439.42) 11.53 16.01 22.55 (292.86) (406.65) (572.77) 15.03 19.51 26.05 (381.76) (495.55) (661.61) 18.53 23.01 29.55 (470.66) (584.45) (750.57) * Internal hole quantity remains constant at 4 holes for all external hole configurations. 2

3010-4515 A 1.2 kv class externally removable secondary bushing Catalog Data CA800018EN 3/8-16 UNC-2B (8, 10 & 12 Hole designs only) 4.0 (102 mm) Ø.56 (14.22 mm) A qty. typ. 1.50 (38.1 mm) 4.02 (102.0 mm) 1.50 (38.1 mm) 1.02 (25.8 mm) 1.31 (33.3 mm) D E Ø 5.25 (133.4 mm) Ø2.87 (72.9 mm) to fit Ø3.06 (77.7 mm) tank hole Ø.405 (10.29 mm) 2.70 (68.6 mm) Figure 2. Line Illustration of 3010 A secondary bushing (90 internal spade) with dimensional information. Note: Dimensions given are for reference only. F Ordering information - 3010 A secondary bushing-90 internal spade To order a 3010 A secondary bushing, specify the catalog number as listed in Table 4. (Gasket and clamp must be ordered separately, see Table 6.) Table 4. Secondary Bushing Dimensional Information Catalog Number 2690476D21 6 2690476D22 8 2690476D23 10 2690476D24 12 External* Quantity of Holes Dimensions in. /(mm) A B C D 6.30 10.80 17.57 (160.02) (274.32) (446.28) 8.05 12.55 19.32 (204.47) (318.77) (490.73) 9.80 14.30 21.07 (248.92) (363.22) (535.18) 11.55 16.05 22.82 (293.37) (407.67) (579.62) * Internal hole quantity remains constant at 4 holes for all external hole configurations. 3

Catalog Data CA800018EN 3010-4515 A 1.2 kv class externally removable secondary bushing 3/8-16 UNC-2B TYP. Ø.56 hole A QTY. (14.22 mm) Ø 2.87 TO FIT Ø 3.06 TANK HOLE (72.9 mm) (77.7 mm) I H 4.0 (102 mm) 1.28 (32.5 mm) 1.60 (40.6 mm) D E G Ø 5.25 (133 mm) Ø C hole B QTY. 2.70 (68.6 mm) F Figure 3. Line Illustration of 4515 A secondary bushing (inline) with dimensional information. Note: Dimensions given are for reference only. Ordering information 4515 A secondary bushing inline To order a 4515 A secondary bushing, specify the catalog number as listed in Table 5. (Gasket and clamp must be ordered separately, see Table 6.) Table 5. Secondary Bushing Dimensional Information (Refer to Figure 3) Catalog Number Qty. of Holes Dimensions in./(mm) A B C D E F G H I 2690130D19 4 4.405 2690130D01 6 4.405 2690130D10 12 4.405 2690130D13 16 4.405 2690130D16 20 4.405 4.63 (117.60) 6.38 (162.05) 11.63 (295.40) 15.13 (384.30) 18.63 (473.20) 9.02 (229.11) 10.77 (273.56) 16.02 (406.91) 19.52 (495.80) 23.02 (584.71) 15.80 (401.32) 17.55 (445.77) 22.80 (579.12) 26.30 (668) 29.80 (757) (25.4) (25.4) (25.4) (25.40) (25.40) 4

3010-4515 A 1.2 kv class externally removable secondary bushing Catalog Data CA800018EN FRONT VIEW SIDE VIEW 6.13 SQ. (155.7 mm) 4.5 SQ. (114.3 mm).50 DIA. HOLES (4) ON A 6.36 DIA. B.C. (12.7 mm) (161.6 mm) Material: almag #35 (25.4 mm) Figure 4. Clamp front and side views with dimensions. FRONT VIEW SIDE VIEW 4.25 O.D. (108.0 mm) 3.50 I.D. (88.9 mm).19 (4.8 mm) Figure 5. Gasket. Note: Dimensions given are for reference only. 5

Catalog Data CA800018EN 3010-4515 A 1.2 kv class externally removable secondary bushing Table 6. Accessories Description Clamp Gasket Catalog Number 2625031B01 0537980C13 Table 7. Recommended Internal (Oil Side) Connections Nominal Rating 3010 A 4515 A Maximum Current Number of Holes 2780 A 4 1 3010 A 4 2 3610 A 4 1 4515 A 4 2 Sides of Spade Note: 1. Ratings are the maximum current level that can be used with a particular configuration. 2. Ratings are based on maintaining a bushing temperature rise that is no more than 15 degrees above 85 degree top oil temperature (20 degree ambient) when the bushings are conducting rated current (IEEE Std C57.12.00-1993 standard, Section 5.11) 3. Ratings are based on maintaining a bushing absolute temperature below the level that would damage the insulation system or seal integrity (with top oil temperature in the range of 113-114 degrees absolute) when the bushing is conducting 150% peak load for 24 hours and 191% peak load for 2 hours. Reference ANSI/IEEE Std C57.92-1981 standard, Table 3(d). (All temperature references are in degrees Celsius.) 6

3010-4515 A 1.2 kv class externally removable secondary bushing Catalog Data CA800018EN 7

Catalog Data CA800018EN 3010-4515 A 1.2 kv class externally removable secondary bushing Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2015 Eaton All Rights Reserved Printed in USA Publication No. CA800018EN Eaton is a registered trademark. All other trademarks are property of their respective owners. For Eaton's Cooper Power series removable secondary bushing product information call 1-877-277-4636 or visit:.