Coils and electronic controls

Similar documents
Electronic Controls Proportional Valve Control Power Plugs

Power Plugs for Proportional Valves (12 volt supply)

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Proportional Valves. Proportional solenoid valves for pressure and flow control

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

Standard Coils and Proportional Valve Coils

Functional Symbols and Application Notes

Solenoid Coils for Switching and Proportional Valves

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi)

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c

COILS AND CONNECTORS. Atlantic Fluid Tech SECTION 21. Rev. 10/ Connector Page class

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls

Continental Hydraulics Installation Manual CEM-AA-A

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

TECH NOTE: E Coils Field Assessment DATE: REVISION: 1.0

OEM Pressure Transmitters

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Cartridge Valves. Proportional Valves Screw-in Cartridge Valves. Vickers. Maximum Pressure 280 bar (4000 psi) - Maximum Flow 160 l/min (42 USgpm)

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

DRV2-080 Adjustable, Direct-Acting Relief Valve

MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

ELECTRIC COMPONENTS HYDRAULIC COMPONENTS

Chapter 2: Directional Control Valves

Proportional Pressure Reducing Valve PDM08130

Proportional Flow-Control Cartridges, Size 5

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

HIGH POWER SOLENOID DRIVER 1

4-way directional servo-valve

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

TECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER

Temperature Sensor MBT 3270

Proportional Directional Valves with Feedback. K(B)FD/TG4V-5, 12 Series Pressures to 315 bar (4500 psi)

Coils - Connectors. Coils Connectors. Summary. RE /06.17 Replaces: RE / Description

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

Directional servo-valve of 4-way design

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

COILS DELTA POWER COMPANY

A1P OPERATING MANUAL

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

Temperature sensor Type MBT 3270

Temperature Sensor MBT Technical brochure

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

Directional Controls

Flow control valve range

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Troubleshooting Bosch Proportional Valves

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Servo solenoid valves with on-board electronics (OBE)

Type 2000 Transducer Product Instructions

20 l/min (5 GPM) p max. Technical Features

Pressure transmitters for heavy duty applications Type MBS 3250

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

MS Application. Features. Proportional Valve Actuator General Instructions

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk

Servo solenoid valves with on-board electronics (OBE)

Technical data for Compact Directional valves

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

SOLENOID VALVES AND PNEUMATIC VALVES

CONTINENTAL HYDRAULICS VED03MX

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

MINI-SOLENOID VALVES direct operated subbase mounted, CNOMO (15 mm width) connector size 15

Directional Controls. EMV-611e Electro-Hydraulic Mobile Control Valve Flows to160 l/min (42 USgpm) System Pressures to 320 bar (4600 psi)

Application Description

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Series 77 & 78. Compact & Modular Valves. solutions. Series 77 - Compact Valves. Series 77 - Sub-D. Series 77 - Fieldbus

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Pilot-Operated Proportional DC Valve Series D*1FH

SBM TECHNOLOGY PET Blow Valve Block

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

3/3 servo directional control valve with mechanical position feedback

Directional servo-valve in 4-way design

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

BF Series Flasher Thermal flasher circuitry

Prop. directional seated valve type EM 21 DE and EM 21 DSE intended as pilot valve

Proportional Valves. Proportional Two-Stage Directional Valves

Transcription:

Hydraulic Screw-in artridge Valves (SiV) oils and electronic controls Solenoid valve and Proportional valve coils and electronic controls for proportional valves

oils and electronic controls TOUGHOILS...-5 S AND P SERIES OILS...-9 J SERIES OILS...-10 H SERIES OILS...-11 LARGE TOUGH OILS...-12 L SERIES LARGE TOUGHOILS...-14 R SERIES LARGE TOUGHOILS...-15 LEGAY R & L SERIES OILS...-16 13 AND 16 SERIES -OIL INFORMATION...-17 13 AND 16 SERIES - SOLENOID OIL...-18 EPV SERIES PROPORTIONAL VALVE OILS EPV OILS...-19 EFV SERIES PROPORTIONAL VALVE OILS EFV...-20 ELETRONI ONTROLS...-21 MODEL ODE/OPERATING DATA...-22 INSTALLATION DATA...-23 ELETRONI ONTROLS...-27 MODEL ODE/OPERATING DATA...-28 INSTALLATION DATA...-29 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 February 2018 www.eaton.com -3

Toughoils Information Toughoils Eaton/IH Toughoils have been designed to provide industry leading environmental protection and solenoid performance in a compact and rugged package. Toughoils with integrated connectors are rated up to IP69K environmental protection. Toughoils are available with a variety of popular integrated connection options and with wire leads. The best in class, one-piece, shell encapsulated, design meets the most stringent environmental requirements for mobile and industrial applications. The exclusive compact coil design from Eaton/IH, offers the advantage of field retrofitability on all existing, and new, applications. Toughoils features IP69K Environmental Protection - This rating provides protection against the ingress of dust and high pressure jet stream. The IP69K test was designed specifically for rating protection against a high-pressure jet stream, high liquid temperature and close nozzle distance from the enclosure surface. IP69K protection is standard on coils with MetriPac or Deutsch, integrated connectors. Thermal shock dunk Test - Eaton/IH Toughoils have been qualified to withstand the toughest Mobile Equipment Thermal Shock Dunk tests. Integrated Deutsch, MetriPack 1 and Leadwire 2 connectors exceed Thermal Shock Dunk test qualifications at 140. The Thermal Shock Dunk test requires coils to be heated, reaching a stabilized temperature of 100, then immediately immersed in a solution at 0. The thermal shock is repeated five times with the coil monitored for dielectric strength in the solution and functional performance is verified. In addition, Toughoils passed a more severe powered dunk test conducted from 100 to 0 with 115% rated voltage applied. Field retrofitable - Toughoils replace all current Eaton coils used on D Frame and Shell type coils. ompact coil dimensions allow substitution in all existing applications. Toughoils are available for most 8, 10, 12, 16 and 20 series valves. No additional water/weather proofing is required. Steel Shell encapsulated design - Toughoils provide protection against physical and environmental damage. 1 MetriPack 150 and MetriPack 280 are registered trade marks of Delphi Packard Electric Systems 2 oils with integrated connectors are recommended for applications in harsh environments. Eaton/IH Toughoils, with rated connector, meet or exceed all major OEM environmental protection requirements Shown with deutsch connection options -4 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

Toughoils Model code S,P,J and H series coils Model code MS * *** * ** * ** 10 1 2 3 4 5 6 7 8 1 Function MS - Solenoid coil 2 Series S - Size 8 (210 Bar) P - Size 8 (350 Bar) J - Size 10, 12, 16, 20 (210 Bar) H - Size 10, 12, 16, 20 (350 Bar) 3 Voltage rating 012-12 volt 024-24 volt 036-36 volt 048-48 volt 115-115 volt 230-230 volt 4 Voltage type D - D B - D/with flyback diode A - A/with full bridge rectifier 5 G0 - ISO 4400 DIN 43650 Q0 - Spade Terminals W0 - Flying lead N0 - Deutsch Male, DT04-2P, Integrated (D Only) Mating : Deutsch DT06-2S Y0 - Amp Jr (D Only) Mating : AMP 963040-3 or equivalent D0 - MetriPack 150 Male, Integrated (D Only) Mating : Delphi 12052641 J0 - MetriPack 280 Male, Integrated (D Only) Mating : Delphi 15300027 E0 - Weather Pack (Packard) female on wire leads Mating : Delphi 12010973 F0 - Weather Pack (Packard) male on wire leads Mating : Delphi 12015792 NNote: Auxillary parts formating connectors may be required. 6 Lead length 0 - None A - 152mm [6.0 in] (Standard length with connector) B - 610mm [24.0 in] (Standard length without connector) 7 Special features 00 - None (Only required if valve has special features, omitted if 00. ) 8 Design code 10 - Design code Specifications Ratings and specifications Duty Rating Operating temperature Lead Wires Power Rating Encapsulent Magnet Wire Flyback diode (arc suppressor) ontinuous from 85% to 110% of nominal voltage 100 (212 F) continuous @ nominal voltage 18 gauge, standard 610 mm (24 ) long, UL style 3173 SA L 1251 (meets SAE J1128 XLPE style SXL) S Series: 20W P Series: 23W J Series: 23W H Series: 29W Glass filled nylon U.L. class N, 200 (392 F) NEMA pub. No. MW 1000, section MW 35 (single) Maximum recurrent peak reverse voltage 800 V (optional) Environmental protection aution oils may be hot to touch if used in continuous duty applications. Ip65 Ip67 Ip69k Thermal shock dunk G0: DIN 43650 X* Q0: Spade Y0: Amp Jr. X X 1 * W0: Wire Leads X X X 1 N0: Deutsch X X X X D0: Metri-Pack 150 X X X X J0: Metri-Pack 280 X X X X 1 Passed environmental testing, but not as robust as other connectors *Rating dependent on mating connector Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -5

Toughoils For 8 size solenoid valves S & P series coils S Series Toughoils part numbers - 300AA00 (omplete part number is 11 Digits) Voltage G0** Q0 W0 N0 Y0 D0 12VD 001A 009A 015A 021A 026A 031A 036A 24VD 002A 010A 016A 022A 027A 032A 037A 36VD 003A 011A 017A 023A 028A 033A 038A 24VA 004A 012A 018A 115VA 005A 230VA 006A 12VD* 007A 013A 019A 024A 029A 034A 039A 24VD* 008A 014A 020A 025A 030A 035A 040A J0 *With flyback diode. (Voltage Type B) **DIN 43560 mating connector for G0 style coil 02-166796. For other voltages and connectors contact your Eaton representative. Std. voltages Amperes* 12 D 1.67 24 D 0.83 36 D 0.56 24 A 0.93 115 A 0.19 230 A 0.10 (+) Voltage Type B (-) *Nominal voltage 25 (77 F). P Series Toughoils part numbers - 300AA00 (omplete part number is 11 Digits) Voltage G0** Q0 W0 N0 Y0 D0 J0 12VD 041A 049A 055A 061A 066A 071A 076A 24VD 042A 050A 056A 062A 067A 072A 077A 36VD 043A 051A 057A 063A 068A 073A 078A 24VA 044A 052A 058A 115VA 045A 230VA 046A 12VD* 047A 053A 059A 064A 069A 074A 079A 24VD* 048A 054A 060A 065A 070A 075A 080A *With flyback diode. (Voltage Type B) **DIN 43560 mating connector for G0 style coil 02-166796. For other voltages and connectors contact your Eaton representative. Std. voltages Amperes* 12 D 1.92 24 D 0.96 36 D 0.64 24 A 1.06 115 A 0.22 230 A 0.11 (+) Voltage Type B (-) *Nominal voltage 25 (77 F). -6 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

Toughoils For 10, 12, 16 and 20 size solenoid valves J & H series coils 300AA00 (omplete part number is 11 Digits) Voltage G0** Q0 W0 N0 Y0 D0 12VD 081A 089A 095A 101A 106A 111A 116A 24VD 082A 090A 096A 102A 107A 112A 117A 36VD 083A 091A 097A 103A 108A 113A 118A 24VA 084A 092A 098A 115VA 085A 230VA 086A 12VD* 087A 093A 099A 104A 109A 114A 119A 24VD* 088A 094A 100A 105A 110A 115A 120A J0 *With flyback diode. (Voltage Type B) **DIN 43560 mating connector for G0 style coil 02-166796. For other voltages and connectors contact your Eaton representative. Std. voltages Amperes* 12 D 1.92 24 D 0.96 36 D 0.64 24 A 1.06 115 A 0.22 230 A 0.11 (+) Voltage Type B (-) *Nominal voltage 25 (77 F).* H Series Toughoils part numbers - 300AA00 (omplete part number is 11 Digits) Voltage G0** Q0 W0 N0 Y0 D0 J0 12VD 121A 129A 135A 141A 146A 151A 156A 24VD 122A 130A 136A 142A 147A 152A 157A 36VD 123A 131A 137A 143A 148A 153A 158A 24VA 124A 132A 138A 115VA 125A 230VA 126A 12VD* 127A 133A 139A 144A 149A 154A 159A 24VD* 128A 134A 140A 145A 150A 155A 160A *With flyback diode. (Voltage Type B) **DIN 43560 mating connector for G0 style coil 02-166796. For other voltages and connectors contact your Eaton representative. Std. voltages Amperes* 12 D 2.42 24 D 1.21 36 D 0.81 24 A 1.34 115 A 0.28 230 A 0.14 (+) Voltage Type B (-) *Nominal voltage 25 (77 F). Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -7

S and P Series coils Dimensions 28,0 [1.10] 34,3 [1.35] 29,5 [1.16] 39,7 [1.56] G0 DIN 43650-A 31,8 [1.25] 12,9 [.51] Shown with integrated Deutsch 17,5 [0.69] 34,5 [1.36] 29,5 [1.16] 26,2 [1.03] 26,2 [1.03] 28,0 [1.10] Q0 Spade connector W0 Leadwire 37,1 [1.46] 35,6 [1.40] 31,2 23,4 [1.23] [.92] 24,9 [.98] 34,8 [1.37] 27,9 [1.10] N0 Deutsch Male DTO4-2P integrated connector Y0 AMP Junior timer integrated connector 35,1 [1.38] 37,6 [1.48] 29,7 [1.17] 24,1 [.95] 33,9 [1.33] 25,4 [1.00] D0 Metri-Pack 150 Male, integrated connector J0 Metri-Pack 280 Male, integrated connector -8 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

J Series coils Dimensions 33,5 [1.32] (.685) 29,5 [1.16] 31,5 [1.24] 46,5 [1.83] Ø 38,9 [1.53] 12,9 [.51] G0 DIN 43650-A Shown with integrated MetriPack 150 (.685) 34,3 [1.35] 29,5 [1.16] 26,2 [1.03] 29,7 [1.17] 31,5 [1.24] Q0 Spade connector W0 Leadwire 36,8 1.45] 35,3 [1.39] 5,1 [.20] 34,8 [1.37] 28,4 [1.12] 38,4 [1.51] 31,5 [1.24] N0 Deutsch male DTO4-2P integrated connector Y0 AMP Junior timer integrated connector 35,1 [1.38] 37,6 [1.48] 33,3 [1.31] 27,7 [1.09] 37,3 [1.47] 28,9 [1.14] D0 Metri-Pack 150 Male, integrated connector J0 Metri-Pack 280 Male, integrated connector Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -9

H Series coils Dimensions 33,5 [1.32] (.685) 29,5 [1.16] 31,5 [1.24] 46,5 [1.83] Ø 38,9 [1.53] 17,6 [.69] G0 DIN 43650-A Shown with integrated MetriPack 280 (.685) 34,3 [1.35] 29,5 [1.16] 26,2 [1.03] 29,7 [1.17] 31,5 [1.24] Q0 Spade connector W0 Leadwire 36,8 1.45] 35,3 [1.39] 5,1 [.20] 34,8 [1.37] 28,4 [1.12] 38,4 [1.51] 31,5 [1.24] N0 Deutsch male DTO4-2P integrated connector Y0 AMP Junior timer integrated connector 35,1 [1.38] 37,6 [1.48] 33,3 [1.31] 27,7 [1.09] 37,3 [1.47] 28,9 [1.14] D0 Metri-Pack 150 Male, integrated connector J0 Metri-Pack 280 Male, integrated connector -10 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

Large Tough oils Model ode L and R Series oils Model code LT 2 ** * *** K N0 0 00 10 1 2 3 4 5 6 7 8 9 10 1 Function 5 Voltage rating 8 Lead length LT - Solenoid coil 2 ontrol type 2 - Voltage ontrol (on/off) 012-12 volt 024-24 volt 6 Voltage type protection K - D with no protection 0 - None - 152mm [6.0 in] (Standard length with connector) J - 622mm [24.5 in] (Standard length without connector) 3 Power rating AA - 30W (standard for R series) AG - 28W (standard for L series) G - A w/ full bridge rectifier M - D w/ bi-directional Diode 9 Spcecial features 00 - None 4 Series L - 10 size for ESV9 and SV9A valves (17.6mm inner diameter) R - 10 and 12 size used on SV*M solenoid valves (23.6mm inner diameter) 7 type N0 - Deutsch male, DT04-2P, integrated W0 - Flying lead Y0 - Amp Jr (D Only) Mating : AMP 963040-3 or equivalent 10 Design code 10 - Design code Specifications Ratings and Specifications Duty Rating ontinuous from 85% to 110% of nominal voltage Operating temperature 100 (212 F) continuous @ nominal voltage Power Rating L Series: 28W R Series: 30W Encapsulent Glass filled nylon Magnet Wire U.L. class N, 200 (392 F) NEMA pub. No. MW 1000, section MW 35 (single) Environmental protection IP65 IP67 IP69K Thermal shock dunk Y0: Amp Jr. X X* W0: Wire Leads X X X N0: Deutsch X X X X *Rating dependent on mating connector aution oils may be hot to touch if used in continuous duty applications. Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -11

Large Tough oils L & R Series oils L Series Toughoils part numbers - 309AA00 (omplete part number is 11 Digits) Voltage Q0 W0 N0 Y0 D0 12VD 041A 24VD 042A For other voltages and connectors contact your Eaton representative. J0 Std. voltages Amperes* 12 D 2.35 24 D 1.17 *Nominal voltage 25 (77 F). (+) Voltage Type B (-) R Series Toughoils part numbers - 309AA00 (omplete part number is 11 Digits) Voltage Q0 W0 N0 Y0 D0 12VD 001A 006A 24VD 017A 021A For other voltages and connectors contact your Eaton representative. J0 Std. voltages Amperes* 12 D 2.50 24 D 1.25 *Nominal voltage 25 (77 F). (+) Voltage Type B (-) -12 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

L Series Large Toughcoils 36.02 [1.418] REF Ø 46.28 [1.822] MAX THIS END designed per deutsch DT04-2P connector interface dwg. Rev. N/ 34.11 [1.343] REF 22.1 [.870] REF 33.60 [1.323] REF Ø 45.85-45.99 [1.805-1.811] 17.65-17.71 Ø [.695-.698] Ø 22.64-22.68 [.891-.893] 43.76 [1.723] NOM Label may be located on either side of coil 51.49-51.99 [2.027-2.047] N0 Deutsch Male DTO4-2P integrated connector Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -13

R Series Large Toughcoils Dimensions designed per Deutsch DT04-2P connector Interface DWG, rev. N/ Ø 46.28 [1.822] MAX THIS END 22.10 [.870] REF 33.61 [1.323] REF 34.02 [1.339] REF 35.93 [1.414] REF 43.76 [1.723] NOM Ø 45.85-46.00 [1.805-1.811] Ø 23.64-23.71 [.931-.934] 51.49-52.00 [2.027-2.047] Label may be located on either side of coil N0 Deutsch Male DTO4-2P integrated connector -14 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

Legacy R & L Series oils For SVx-12-3 and SVx-12-4 solenoid valves L series coils ( EN490 coils) D oils Voltage G DIN 43650 connector W Leadwires only Full Power oils: 12V 02-309454 02-309452 24V 02-309455 02-309453 NNote: For more information on L series coils, please refer to Eaton Technical datasheet 5049/EN/0596/A (Solenoid Operated Directional Valve-DG4V-35, EN490 for Mobile Equipment). R series coils (Blue coils) D oils Voltage G DIN 43650 connector Q SpaDe connector W Leadwires only Full Power oils: 12V 507847 02-111166 02-140394 24V 507848 02-111168 02-140395 NNote: For more information on R series coils, please refer to Eaton Technical datasheet V-VLDL-M011-E (Solenoid Operated Directional Valve-DG4V-35 and DG4V3 Series). R and L series coils Power consumption D solenoids at rated voltage and 20 (68 F) Full Power oils: 12V 24V 30W 30W Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -15

13 and 16 Series - coil information FPO Electrical onnection Bobbin Encapsulation Duty rating The coil is rated for continuous operation at nominal voltage +/- 10% and an ambient range of -20 to +40. NNote: oil performance, force produced and power consumed, is affected by the heat of the coil, performance figures given in this catalogue are measured under simulated continuous duty conditions at the coil stabilized temperature. It is important to verify the actual conditions the valve will experience for any given application it should be tested in situ to confirm valve selection. Wattage 13 (for 13 mm tubes) = 14, 22 & 27 Watts 16 (for 16 mm tubes) = 19 & 29 Watts Voltages Standard 12 VD 110 VRA 24 VD 220 VRA Special/Optional Other Voltages are available on request opper Winding Iron Frame/Yoke Location of O ring seal between coil and tube Alternating current For A voltage an ISO4400 rectified connector must be used, as the coils are wound for D. The correct connector is available from the factory: 110 VA = AXP9997-115 220 VA = AXP9997-230 VDR is fitted for over-voltage protection. Diodes are rated at 1.5 amp. + Wire insulation The coil winding is copper magnet wire insulation equivalent to class N (200 ). Encapsulation material 13, 14 Watt coils and 16, 19 Watt coils are black in colour and made from PBT (Black Polybutylene Reinforced) equivalent to lass F (155 ) 13, 22 & 27 Watt coils and 16, 29 Watt coils are black in colour and made from IXEF (Black Polyarylamide Reinforced) equivalent to lass H (180 ) Ingress protection (IP) BS EN 60529 The coil/tube joint is sealed by O rings preventing fluid ingress and the possibility of tube corrosion. Different electrical connectors offer different levels of protection the minimum being the DIN 43650 connector with a gasket at IP65. Integrated Hydraulics offer a wide range of connector types - details of which are available on request. s H = ISO4400 Standard DIN43650 2 pin and earth F = Black Flying Leads 1.5mm 2 wire 600 mm long, 15 AWG, 2.2 mm diameter, Teflon FEP covered (D voltage only) DM = Deutsch Moulded 2 way DT04-2P series (D voltage only). aution When handling coils after or during use they may be hot which can cause burning to the skin. Handle with care and use the appropriate equipment. D oil - A Voltage ircuit Diagram -16 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

13 and 16 Series - solenoid coil Model code 13 H 24 / 22 1 2 3 4 1 oil Series 13-13 mm tube 16-16 mm tube 2 onnection H - DIN43650 ISO Standard F - Flying Leads (12 and 24 VD only) DM - Deutsch Moulded (12 and 24 VD only) (onsult factory for other options) 3 Voltage 12 12 VD 24 24 VD 110 110 VRA 220 220 VRA* *220 to 240 VA All A coils must be used with a rectifying connector: (AXP9997-115 or AXP9997-230) (Other voltages available on request) 4 Wattage 13 16 14 = 14 Watt 19 = 19 Watt 22 = 22 Watt 29 = 29 Watt 27 = 27 Watt We reserve the right to change specifications without notice 13 oils 47.8 (1.88) 16 oils 49.0 (1.93) 38.1 (1.50) 50.0 (1.97) 23.9 (0.94) 36.0 (1.42) 35.5 (1.40) 22.0 (0.87) Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -17

EPV Series proportional valve coils EPV coils ontrol and specifications Rheostat Power plug options Amplifier card Joystick suppliers 12 VD operation 10-12, 20-25 watts 24 VD operation 25-30, 20-25 watts EHH-AMP-702, EPAD-SA-1A6-10 (Require 24 VD power supply to power plug and 12 VD coil) EEA-PAM-523 (Requires 24 VD power supply and either 12VD or 24 VD coil) OEM ontrols, Inc, Shelton, T P-Q ontrols, Inc, Bristol, T Std. voltages Amperes* Lead color Power rating 12 D 1.32 red 16 W 24 D.66 black 16 W *Nominal voltage @ 25 (77 F). oil part numbers Voltage F Q U* W Y 12VD 02-308810 02-317154 02-154070 02-154072 02-308808 24VD 02-308811 02-317155 02-154071 02-154073 02-308809 *DIN 43650 mating connector for U style coil 02-166796. oil configurations F - Weather-Pack male on leads Q - Spade terminal U DIN 43650 aution oils may be hot to touch if used in continuous duty applications. W 610 mm (24 inch) lead wire Y - Metri-Pack 150 male on leads Note: Width all configurations Ø 43,5 (1.71) -18 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

EFV Series proportional valve coils EFV M series coils ontrol and specifications Power plug options DIN Rail Module EHH-AMP-702 (Requires 24 VD power supply to power plug and 12 VD coil) EHH-AMP-712 (Requires 12 VD power supply to power plug and 12 VD coil) EHH-PAM-600 (Requires 24 VD power supply and 12VD) aution oils may be hot to touch if used in continuous duty applications. Specifications Standard Voltage Resistance Power 12 VD 4.7 Ω 30 W 24 VD 19.0 Ω 30 W oil model code MS *** *** * ** ** ** ** 1 2 3 4 5 6 7 8 1 Function MS - Solenoid oil 2 Series M - Size 10 (210 Bar) 3 Voltage rating 012-12 volt 024-24 volt 4 Voltage type D - D 5 G0 - ISO 4400 DIN 43650 W0 - Flying lead 0 - Deutsch Male, DT04-2P, On wire leads NNote: Auxiliary parts for mating connectors may be required. 6 Lead length 0 - None A - 152mm [6.0 in] (standard length with connector) B - 610mm [24.0 in] (standard length without connector) K - 127mm [5.0 in] DIN 43560 mating connector for G style coil 02-166796. oil kits Standard coil Part numbers Model code Assembly number MS012DGE00 6034440-001 MS024DGE00 6034440-002 MS012DWE00 6034441-001 MS012DE06 6034442-002 Ø 44,2 (1.74) 53.3 (2.10) 54.6 (2.15) Ø 20,7 (0.815) 56,134 (2.21) NNote: Width all configurations G - DIN 43650 W - 610 mm (24 inch) lead wire - Deutsch DT0402P on leads Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -19

Electronic controls Proportional valve control power plugs EHH-AMP-702-D/K-* Series For use with valve typese: EPV**-12D-1* EFV1-**-012DE* ERV1/2**-12D-1* EPRV1/3**-12D-1* ESV1**-12D-1* IRV**-012D-1* PFR21* PFR24* PDR21A* PPD22**-012D-1* Application Primary applications are in the control of non-feedback proportional valves where the cost of more sophisticated electronic controls can be avoided. Type J is typically used in closed-loop applications. General description Three types of plugs, conforming to ISO 4400/DIN 43650 interface, with integral amplifiers and necessary adjustment potentiometers, are designed for use with non-feed back hydraulic valves. This plug/valve combination offers very low cost solutions to many hydraulic control problems requiring proportional control. Type D is controlled with a 0-10V command signal, and has adjustable gain, ramp, deadband compensation and dither. For closed-loop and no ramp applications adjust the ramp port to minimum setting. Type K is controlled with a 4-20 ma command signal, and has an adjustable ramp time of 50 ms to 5s. Features and benefits Integral amplifier provides essential functions for control of proportional valves Adjustable ramp time (types D and K), gain, deadband compensation and dither Ease of installation, with reduced cost Fully short-circuit and reverse-polarity protected Differential voltage command signal (type D) Adjustable dither EM to latest European standards Protection to IP67 Electrical block diagram EHH-AMP-702-D/K-* NNote: This product has been designed and tested to meet specific standards outlined in the European Electro-magnetic ompatibility Directive (EM) 89/336/EE, amended by 91/26/EE, 92/31/EE and 93/68/EE, article 5. For instructions on installation requirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic Products leaflet 2468. Wiring practices relevant to this Directive are indicated by a warning symbol and Electromagnetic ompatibility (EM). -20 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

Model code/ operating data Model code EHH - AMP - 702 - * - R - P - * - 30 1 2 1 Adjustment range D - Proportional plug: 0-10 VD with ramp K - Proportional plug: 4-20 ma with ramp 2 able gland 1 - PG9 2 - M16 Operating data Electrical onnections 1 2 3 4 Power (input) supply Absolute maximum voltage Max. power consumption including solenoid Reverse polarity protected Short circuit protected Types D 24V D Supply GND Positive command signal Negative command signal 18-36V D including ± 10% maximum ripple (peak-to-peak) 24V D nominal 40V 35W Yes Yes Maximum output current 1,6A Maximum output voltage typical (1,6A output current) Typically 1,5V below supply voltage Type K ommand signal 0-10V (10 kohms) 4-20 ma (250 ohms) Deadband triggering For output (LED on) For no output (LED off) Deadband adjustment range 200 mv 200 mv to 10V 0 mv to 100 mv 100 to 1000 ma 4 ma 4-20 ma 0-4 ma Gain adjustment range 0.02A/V to 0.16A/V 0.01 A/mA to 0.08 A/mA Dither adjustment range Ramp time (types D and K only) 0 to 500 ma 50 ms to 5s PWM frequency 1200 Hz ± 10% Dither frequency 120 Hz ± 10% Protection Isolation to VDE 0110 Electromagnetic compatibility (EM): Emission Immunity IE 529: IP67 (when correctly installed with interface seal in place) Fully short-circuit and reverse-polarity protected Group B EN 50081-2 EN 50082-2 Mechanical Housing PA6 glass-reinforced plastic (conforming to UL-94HB). olor: gray Mounting interface ISO 4400 (DIN 43650) able clamp Pg9 screw type able diameter Ø 5 to 10 mm (0.197 to 0.394 dia.) Wire section 0,5 to 1,0 mm2 (20-17 AWG) Temperature, ambient range -20 to +70 (-4 to +158 F) Mass 0,07 kg (0.154 lb) Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -21

Installation data Input/output characteristics Type K and D ommand signal Type K 20 ma 12 ma 4 ma Type D 10V 8V 6V 4V 2V Time Type om signa volta Output current Ramp setting U S X Gain setting Deadband compensation Time Installation dimensions mm (inch) 88 (3.52) 22 (0.87) 3rd angle projection 39 (1.54) Solenoid onnections 1 (or 2) No connection 34 (1.34) 38 (1.5) 1 2 2 (or 1) -22 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

Installation data Adjustments Ramp timee: Turn clockwise to increase ramp time (Only types D/K). Gaine: Turn clockwise to increase gain. Deadband compensatione: Turn clockwise to increase deadband compensation current. Dithere: Turn clockwise to increase the dither current. Terminal 1e: Power Supply 18-36V D, positive. Terminal 2e: Power Supply 0V. Terminal 3e: ommand signal positive (see Operating Data ). Terminal 4e: ommand signal negative (see Operating Data ). Installation wiring options Warning Electromagnetic ompatibility (EM) - Screened cables should be used and particular attention paid to the grounding of the screens as shown in the above diagrams. Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -23

Installation data Assembly showing wiring connection points Warning Ensure cable clamp nut is adequately tightened to secure cable. Do not connect, or disconnect, the plug while power is on. Do not mount, or dismount, the plug while power is on. *All seals must be fitted correctly at plug installation to provide protection to IP67 (IE 529). -24 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

Installation data Start-Up procedure With the plug correctly wired but not mounted to the load provide with a D power supply (See table). Apply the command signal (ON) and check the Power ON LED (RED) illuminates. Reduce the signal to the ommand signal (OFF) level and check the LED (RED) goes out. If there is malfunction to the LED replace the plug. Switch off the power supply and command signal and connect the plug to the load. Ensure that the interface seal is correctly fitted and clamped between the mounting faces (essential for IP65 protection). Tighten the retaining screw. Ensure that no damage or injury will occur on the machine when the valve is operated. Switch on the power supply. Apply the command signal. (a) Observe Power On LED (RED) is ON. (b) Observe PWM LED (Orange) is ON. If LED is not operated then there is short circuit in the load. Replace the load/ load coil. Successful completion of these steps means that the plug and load are ready for normal use. Spare parts The only spare part available is the interface seal, part number 732100. Ordering procedure Order plug by full model code, and spare interface seals by part number 732100. Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -25

Electronic controls Soft Switch power plugs EHH-AMP-702--* 10 Series For use with valve typese: EPV**-12D-1* EFV1-**-012DE* ERV1/2**-12D-1* EPRV1/3**-12D-1* ESV1**-12D-1* IRV**-012D-1* PFR21* PFR24* PDR21A* PPD22**-012D-1* Application Focus applications for this plug are in the control of hydraulic solenoid operated directional and pressure control valves where control of valve response time can significantly reduce shocks in the hydraulic system. Best results in reducing hydraulic shocks will only be obtained by using valves with the right low shock, or proportional features. General description These plugs, conforming to ISO 4400/DIN 43650 interface, offer adjustable, ramped on/off switching times through the use of an integral amplifier. The switching time range is 50 ms to 5 seconds. The soft switch plug is rated for 24V D nominal and controlled by a 24V logic signal. Applying an on signal causes the output current to ramp up to, and stay at, an adjustable maximum while the on signal is maintained. At switch-off the output current is ramped down to zero and will remain at zero until the next on signal. Ramp times (switching times) can be adjusted by an in-built potentiometer. An adjustment also allows for compensation of any deadband in the valve. Features and benefits Integral amplifier provides control from on/off logic command signal Adjustable ramp time Deadband compensation Adjustable output level Adjustable dither EM to latest European standards Improved switching time repeatability Fully short-circuit and reverse-polarity protected Protection to IP67 Electrical block diagram EHH-AMP-702--* 10 Series NNote: This product has been designed and tested to meet specific standards outlined in the European Electro-magnetic ompatibility Directive (EM) 89/336/EE, amended by 91/26/EE, 92/31/EE and 93/68/EE, article 5. For instructions on installation requirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic Products leaflet 2468. Wiring practices relevant to this Directive are indicated by a warning symbol and Electromagnetic ompatibility (EM). Power input 24V D 0V ommand Signal + 1 2 3 4 (N) 2k7W Ramp Dither Gain Deadband Max. limiter PWM Power amp. X1 Solenoid X2-26 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

Model code/ operating data Model code EHH - AMP - 702 - - * Operating data Electrical onnections 1 2 3 4 Power (input) supply Absolute maximum voltage Max. power consumption including solenoid Reverse polarity protected Short circuit protected 24V D OV (power and signal) Positive command signal Negative command signal 18-36V D including ± 10% maximum ripple ripple (peak-to-peak) 24V D nominal 40V 35W Yes Yes Maximum output current 1,6A Maximum output voltage typical (1,6A output current) ommand signal For output (LED on) For no output (LED off) Input impedance Deadband adjustment range Gain adjustment range Dither adjustment range Ramp time Typically 1,5V below supply voltage 11 to 24V 0V to 5V 10 KOhm ohms <100-1000 ma 0.02A to 1,6A (maximum) 0 to 500 ma 50 ms to 5s PWM frequency 1200 Hz ± 10% Dither frequency 120 Hz ± 10% Protection Isolation to VDE 0110 Electromagnetic compatibility (EM): Emission Immunity IE 529: IP67 (when correctly installed with interface seal in place) Fully short-circuit and reverse-polarity protected Group B EN 50081-2 EN 50082-2 Mechanical Housing PA6 glass-reinforced plastic (conforming to UL-94HB). olor: gray Mounting interface ISO 4400 (DIN 43650) able clamp able diameter Wire section Temperature, ambient range Mass Pg9 screw type Ø 5 to 10 mm (0.197 to 0.394 dia.) 0,5 to 1,0 mm2 (20-17 AWG) -20 to +70 (-4 to +158 F) 0,07 kg (0.154 lb) Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -27

Installation data Input/Output characteristics Functions Switch-on/off: after switching on with a 11V signal the amplifier will remain in the on condition with a command signal above 6V. The command signal must be reduced to below 5V to achieve switch-off of the amplifier. ommand signal 24V, typical Time Output current Ramp time Gain adjustment Deadband compensation Time Installation dimensions mm (inch) 88 (3.52) 22 (0.87) 3rd angle projection 39 (1.54) Solenoid onnections 1 (or 2) No connection 34 (1.34) 38 (1.5) 1 2 2 (or 1) -28 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

Installation data Adjustments Ramp timee: Turn clockwise to increase ramp time. Gaine: Turn clockwise to increase gain. Deadband compensatione: Turn clockwise to increase deadband compensation current. Dithere: Turn clockwise to increase the dither current. Terminal 1: Power Supply 18-36V D, positive. Terminal 2: Power Supply 0V. Terminal 3: Switch command signal positive. Terminal 4: Not connected Installation wiring Warning Electromagnetic ompatibility (EM) - Screened cables should be used and particular attention paid to the grounding of the screens as shown in the above diagram. 24V 0V >11 V Protective ground connection 4 3 2 1 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -29

Installation data Assembly showing wiring connection points Warning Ensure cable clamp nut is adequately tightened to secure cable. Do not connect, or disconnect, the plug while power is on. Do not mount, or dismount, the plug while power is on. *All seals must be fitted correctly at plug installation to provide protection to IP67 (IE 529). -30 Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com

Installation data Start-Up procedure orrectly wire the plug and, before mounting it on the valve solenoid, apply 24V D (18 to 36V limits) to the power input terminals. heck for correct plug function by illumination/ non-illumination of the LED: a. Apply less than 2 to 3 volts to the input terminal: LED should not be illuminated. b. Increase voltage: the LED should illuminate when the voltage reaches 11V. Do not exceed 30V command signal. c. Decrease voltage: the LED should go off when the voltage is less than 5V. Switch off power supply and command/input signal and then install plug on solenoid. Ensure that all seals are fitted correctly and clamped as the retaining screw is tightened: this is essential in providing IP67 protection. Ensure that the hydraulic system will not cause any erratic movement of actuators, then: Switch on power supply again. Repeat LED/function check as in 2. An LED malfunction now indicates a short circuit at the load. Successful completion of these checks means that the plug and load are ready for use. Spare parts The only spare part available is the interface seal, part number 732100. Ordering procedure Order plug by full model code, and spare interface seals by part number 732100. Eaton Hydraulic Screw-in artridge Valves (SiV) E-VLS-M001-E6 January 2018 www.eaton.com -31