Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

Similar documents
Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Ocelot vertical fan coil unit

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Highline 260i EC Waterside Fan Coil Unit

INHERENTLY QUIET AND POWERFUL 180 MM DEEP SLIMLINE HORIZONTAL WATERSIDE CONTROL IN CEILING

The World Leading Air-conditioning Company

Floor Swirls Models BZD and SZD

HIGH CAPACITY LINEAR SLOT DUFFUSERS

LINEAR SLOT DIFFUSERS

Actionair Control and Shut Off Dampers

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25

IrisControlDamper. For Adjustment and Measuring of Airflow.

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

Features: Available in horizontal and vertical units

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Fan - Powered Terminal Unit Series Flow

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

FlowBar High Capacity Slot Diffuser

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Blade Features. AirShield Control and Shut Off Dampers. AirShield

LINEAR SLOT DUFFUSERS

KLIMA Active Chilled Beams

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

Perforated Face Ceiling Diffusers

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Linear Floor Grilles Models FG, F20, F25 and FRO

Warning. Document ref: A October 2015

Slot diffusers, Round duct diffusers. IMP Klima

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

Carisma The Ultra Quiet Fan Coil

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

Fan coil unit NBS 100/150

Ceiling swirl diffusers

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

technical catalogue Revision 30/4/13 1

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

Fan coil units MAJOR 2 CV/CH

SDV Vane Swirl Diffusers

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Ceiling swirl diffusers

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

BRIZA 22 HYBRID HEATING & COOLING

CENTRIFUGAL FAN COIL UNIT VCE

Catalogue. FlowBar. High Capacity Slot Diffuser.

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

IDENTIFICATION ACCESSORIES DESCRIPTION

Cell Ventilation Security Grille

Ceiling induction diffuser DISA-601

Ceiling induction diffuser DISA-300

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

SINGLE DUCT TERMINAL UNITS

Sapphire Horizontal Waterside Control Fan Coil Units

MODULAR AIR HANDLING UNITS GAH SERIES

CHILLED WATER FAN-COIL UNITS

Induction terminal units

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Ceiling swirl diffusers with perforated face plate

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Ceiling swirl diffusers

series KFD-KLD Linear slot diffusers

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

VAV TERMINAL BOXES TYPE: BA BT

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Ceiling swirl diffusers with perforated face plate

Total comfort control

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

Slot diffusers for ceiling installation

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

Transcription:

January 2002 Systempac Features and Design Guide Specifically Designed for Design and Build Projects. Complete package including Waterside Control Fan Coil Unit / Controls / Flexible Ducting / Plenum Box / Diffusers. Systempac Fan Coil Unit / Acoustic Flex / Diffuser System Package Choice of Linear Slot Diffusers or 4 Way Throw Louvred-Faced Diffusers. Available in three thermal outputs 2kW / 3kW / 4kW sensible cooling and heating. Fully acoustically and thermally tested. Quick and simple design selection. Customer friendly installation and commissioning. Competitive priced solutions with fastrack delivery.

Product Specification Fan Coil Unit Waterside Control 230mm deep horizontal draw through chassis type Fan Coil Units. Chassis constructed from 1.2mm galvanised sheet steel, with 1.6mm fan deck and back plates. The flush external finish prevents exposure to bare edges and incorporates recessed, reinforced slotted mounting points for ease of installation. Access to fans/motors is via an insulated bottom panel with keyslots for accurate positioning and easy removal. The thermal and acoustic insulation is 100 kg/m 3 density, class O CFC and HFC free open cell foam and complies with Section 20 requirements. External condensate tray insulation is similar in specification, but closed cell type. Fans are double inlet, resiliently mounted direct driven, forward curved centrifugal type and are mounted on an easily removable deck. The motors are permanent split capacitor type external rotor, totally enclosed, speed controllable. A ventilated controls housing mounted on the same side as the control valves, includes a hinged removable cover, three speed selector switch and illuminated on/off switch. Coil matrix blocks are manufactured from seamless copper tube mechanically expanded into aluminium fins having die formed collars, providing a tight bond to optimise heat transfer. Vents and drains are fitted as standard with easily accessible slotted / hexagonal plugs. Coils are pressure tested using dry air under water to 15 bar. Filters are washable EU3 continuous filament filter media to Eurovent 4/5, with F1 fire resistance to DIN 53438 and a dust holding capacity of 380g/m 2. Condensate trays are one piece, welded, galvanised sheet steel, synthetically treated, foam insulated and extended to cover the entire coil and valve assembly and can be easily removed for cleaning / maintenance. The tray has a positive fall to drain with a BSP female connection fitted at the lowest point, on the underside. Controls The controller is a Honeywell T8078B1027 24 Volt non-addressable digital unit, mounted on the outside of the fan coil controls enclosure. The T8078B1027 is designed for individual zone temperature management, but can accept remote set point adjustment from a BMS. The unit provides proportional plus integral (P+I) control of valve/actuators to regulate heating and cooling output. The control has a self calibrating and commissioning function to ensure correct synchronisation of valve/actuators is always maintained. (9 minute test cycle). A remote sensor (encapsulated silicon type) is fitted to the inlet of the fancoil unit after the filter and wired to the T8078B with a 1.5m flying lead. Honeywell 4 port valves with 24 Volt modulating actuators are fitted and wired to both the heating and cooling coils with compression fitting and hydraulically tested to 10 bar. Optional remote temperature sensor and setpoint adjuster are also available. Acoustic Flex 1 metre of 200mm diameter Sonodec25 acoustic flexible ducting is supplied for each outlet spigot. Sonodec25 is insulated both acoustically and thermally. The inner duct is micro-perforated aluminium / polyester flexible with steel spring coil. This is insulated with 25mm fibreglass having a density of 16 kg/m 3. It is completely enclosed in a seamless fibreglass reinforced aluminium outer duct. A polyester barrier is applied between the micro-perforated inner duct and the fibreglass, to prevent ingress of the fibreglass into the airstream. The flex conforms to BS476 parts 6, 7 and 20. Two 'Zip tie' clips are supplied for each discharge duct. Diffusers Linear Slot Diffusers (LS) and Plenum Boxes The 3 slot linear diffuser offers both unobtrusive good looks with functional efficiency and are fully adjustable giving both horizontal and vertical projection. Slot diffusers are manufactured from high quality extruded aluminium sections and come with RAL9010 Eggshell White powder coat frames and Black internal components/blades as standard. Flexibility Each diffuser is 1195mm x 179mm overall size including end flanges, which can either lay-in or fit below a grid, or be second fixed into a plaster margin. Plenum Box Each diffuser is supplied with a galvanised sheet steel plenum box complete with both 198mm diameter side entry spigot and cord operated damper allowing adjustment from the diffuser face. Easy Fixing Each diffuser is complete with U bracket fixings which enable the installer to simply second fix the diffuser within the ceiling. This method is particularly useful when diffusers have to be installed in a ceiling with limited access. Louvred-Faced (LF) Diffusers and Plenum Boxes The louvred-faced diffusers are manufactured from extruded aluminium profiles and offer exceptional performance from a 4 way removable core. All diffusers are finished in RAL9010 Eggshell White power coat. Flexibility The 373mm x 373mm overall size square diffuser can be accommodated within almost all types of ceiling systems. Installation Option Should the installer prefer not to cut a diffuser into a tile, then a 595mm x 595mm overall diffuser can be ordered which simply lays within the ceiling grid. Plenum Box Each diffuser is supplied with a galvanised sheet steel plenum box complete with both 198mm diameter side entry spigot and cord operated damper allowing adjustment from the diffuser face. Easy Fixing Both the 373mm and 595mm overall diffusers are complete with removable cores, which enable the installer to secretly fix by means of either rivet or PK screw. 2

Unit Selection Data Package Speed Room Total Air Sensible Total Air Off CHW Coil + Heating Air Off LTHW Coil + Input Numbers Reference Setting NR Volume Cooling Cooling ( C DB) Flowrate Valve Duty ( C) Flowrate Valve Watts of (l/s) (kw) (kw) (l/s) (kpa) (kw) (l/s) (kpa) Outlets SP2-LS/LF I 35 150 1.5 1.6 14.6 0.08 12.4 1.5 28.3 0.03 3.3 70 2 SP2-LS/LF II 38 170 2.0 2.2 13.2 0.10 19.6 2.0 29.8 0.04 4.4 90 2 SP2-LS/LF III 40 190 2.4 2.4 12.7 0.12 27.9 2.5 31.0 0.06 9.2 110 2 SP3-LS/LF I 35 205 2.5 2.8 12.8 0.13 14.8 2.5 30.2 0.06 2.9 110 3 SP3-LS/LF II 38 225 3.0 3.6 12.0 0.17 33.8 3.0 32.1 0.07 4.3 160 3 SP3-LS/LF III 40 250 3.3 3.8 12.1 0.18 36.3 3.5 32.7 0.08 5.1 180 3 SP4X-LS/LF I 35 270 3.6 3.9 12.2 0.19 31.0 3.5 30.8 0.08 5.2 200 4 SP4X-LS/LF II 38 305 4.0 4.5 12.3 0.21 42.0 4.0 30.7 0.09 6.6 220 4 SP4X-LS/LF III 40 340 4.3 4.7 12.6 0.22 43.0 4.3 31.3 0.10 8.3 240 4 The Fan Coil selections are based on: Cooling: Summer On-coil air 23 C Dry Bulb, 16 C Wet Bulb. Chilled Water flow temperature 6 C. Chilled Water return temperature 11 C. Heating: Winter On-coil air temperature 20 C Dry Bulb. LTHW flow temperature 82 C. LTHW return temperature 71 C. General: External Resistance 15pa. Electrical Supply 230 Volts/ 1 phase /50 Hz. The following refers to specific diffuser performance: Type LS Linear Slot Diffuser Fully adjustable Linear Slot Diffusers with both horizontal and vertical projection. Throw data is based upon a temperature differential of 10 C cooling to terminal velocity of 0.25 m/s for 0mm active length with a room height of 2.7m, when mounted flush with an unobstructed flat ceiling. Package Speed Total Air Volume Slot Diffusers Plenum Boxes Volumetric Flow Throw Reference Setting per Package (l/s) Supplied as Standard Supplied as Standard Rate (l/s per m) (m) I 150 66 3.0 SP2-LS II 170 2 x 1195 long 2 x 1145 long 74 3.4 III 190 83 4.3 I 205 60 2.2 SP3-LS II 225 3 x 1195 long 3 x 1145 long 66 3.0 III 250 73 3.4 I 270 59 2.2 SP4X-LS II 305 4 x 1195 long 4 x 1145 long 66 3.0 III 340 74 3.4 Type LF Louvre-Faced Diffuser 4 Way Louvred-Faced Diffuser (horizontal diffusion), 225mm x 225mm neck size. Throw data is based on a temperature differential of 10 C cooling to a terminal velocity of 0.5 m/s to give average room velocity of 0.18 m/s with a room height of 2.7m, when mounted flush with an unobstructed flat ceiling. Package Speed Total Air Volume Number of Diffusers Air Volume per Throw Based upon Reference Setting per Package (l/s) per Package Diffuser (l/s) 4 Way Diffuser (m) I 150 75 1.8 SP2-LF II 170 2 85 2.0 III 190 95 2.2 I 205 68 1.6 SP3-LF II 225 3 75 1.8 III 250 92 2.1 I 270 68 1.6 SP4X-LF II 305 4 76 1.8 III 340 85 2.0 3

Acoustic Performance Data Typical Horizontal Fan Coil Unit Arrangement FRESH AIR SUPPLY DUCT FAN COIL UNIT MINIMUM 1 METRE LENGTH SONODEC 25 ACOUSTIC FLEX DIFFUSER PLENUM 1.5 metres CONCRETE RETURN AIR GRILLE/DIFFUSER (NOT POSITIONED DIRECTLY BELOW UNIT INTAKES) T BAR GRID FALSE CEILING WITH EITHER 10mm THICK FIBRE BOARD TILES OR METAL PAN TILES WALL/GLAZING INTERNAL ROOM All associated components have to be be mounted in accordance with manufacturer instructions. The fan coil units must be mounted within a false ceiling void of not less than 300mm deep. The false ceiling should be constructed of standard 10mm thick fibre tiles or metal pan tiles with a 15mm acoustic backing. Rooms of open plan or partitioned design have to be be furnished, carpeted and have no more than 20% glass area with no highly Installation Units should be positioned so that access is available for routine maintenance and removal of coils, fans, filters and to open the controls enclosure. All units must be installed in accordance with good engineering standards and due care and attention to eliminate any possible damage. The installation must ensure level positioning to facilitate correct operation and condensate removal. The recommended method of unit reflective surfaces such as ceramic tiles etc. Where a single package is serving a room the dimensions should be based upon a cooling load of 0.12 kw per m 2. In an open plan area units should be mounted at a minimum of 4.5m centres and no closer than 1.5m from a corner. Return air grilles / diffusers (not included within the package, but can be supplied as an optional extra cost item) should be positioned at least 1.5m from the fan coil unit suspension (see below) is by means of M10 studding (supplied by others). The accessory pack includes 3mm rubber washers and large supporting washers. intake. A 1m active length of Sonodec25 acoustic flexible ducting is supplied and must be fitted to each fan coil outlet. The remainder of interconnecting ductwork can comprise up to 3m of rigid spiral ductwork (including one 90 degree bend) or up to 2m additional flexible ducting, on each spigot (supplied by others). For further information a full acoustic report is available on request. All connecting metal ductwork must be supported independently of the fan coil unit spigot connections, in accordance with DW 144. All wiring must comply with all relevant British Standard Codes of Practice and good engineering principles. Drain tray connection fittings should not protrude above the level of the tray to avoid condensate to be held back in the tray. Please refer to the full operation and maintenance instructions prior to installation. 4

Type LS Linear Slot Diffuser Option Cord operated Damper 20 1 No. 8mm hole each end for suspension 300 ø198 32 25 20 179 (Overall) 151 200 1145 (Inside) 1165 Ceiling opening 179 160 Ceiling opening 32 1195 (Overall) Type LF Louvred-Faced Diffuser Option B A Cord operated Damper 20 8mm holes for suspension 300 ø198 32 C (Overall) D (Inside) 200 E (Inside) Dimensions Type A B C D E LF3 225 298 373 225 225 LF6 447 520 595 447 447 All dimensions shown are in mm. 5

Fan Coil Dimensions SP2 REMOVABLE FILTER RETURN Unit Weight HTG Conns CLG Conns SP2 35kg ø15mm ø15mm DIRECTION OF AIR FLOW LHS FLOW CONTROL ENCLOSURE 4 No. RAPID POSITION FIXING SLOTS (TO SUIT M10 STUDING) VALVE FIXING CENTRES 726 276 290 50 120 FIXING CENTRES 160 104 40 15 730 200 50 700 (FIXING CENTRES) HTG INSULATED COVER PLATE FITTED WHERE SPIGOT IS NOT PROVIDED 230 540 100 95 66 45 CLG DRAIN CENTRE LINE Ø 197 SPIGOTS KEYHOLE REMOVABLE ACCESS PANEL 3/4 INCH FEMALE BSP DRAIN CONNECTION SP3 REMOVABLE FILTER RETURN Unit Weight HTG Conns CLG Conns DIRECTION OF AIR FLOW LHS FLOW CONTROL ENCLOSURE 4 No. RAPID POSITION FIXING SLOTS (TO SUIT M10 STUDING) SP3 50kg ø15mm ø22mm VALVE FIXING CENTRES 726 276 290 50 120 FIXING CENTRES 160 104 40 15 1080 200 50 1050 (FIXING CENTRES) INSULATED COVER PLATE FITTED WHERE SPIGOT IS NOT PROVIDED 230 95 66 HTG 540 100 540 350 45 CLG DRAIN CENTRE LINE Ø 197 SPIGOTS KEYHOLE REMOVABLE ACCESS PANEL 3/4 INCH FEMALE BSP DRAIN CONNECTION SP4X REMOVABLE FILTER RETURN Unit Weight HTG Conns CLG Conns DIRECTION OF AIR FLOW LHS FLOW CONTROL ENCLOSURE 4 No. RAPID POSITION FIXING SLOTS (TO SUIT M10 STUDING) SP4X 70kg ø15mm ø22mm VALVE FIXING CENTRES 726 276 290 50 120 FIXING CENTRES 160 104 40 15 1430 200 50 1400 (FIXING CENTRES) INSULATED COVER PLATE FITTED WHERE SPIGOT IS NOT PROVIDED 230 95 66 HTG 540 100 540 350 350 45 CLG DRAIN CENTRE LINE Ø 197 SPIGOTS KEYHOLE REMOVABLE ACCESS PANEL 3/4 INCH FEMALE BSP DRAIN CONNECTION 6

Type LS Linear Slot Diffuser Option LINEAR SLOT DIFFUSER (LS) PLENUM BOXES SONODEC 25 ACOUSTIC FLEX SP3 FANCOIL UNIT Type LF Louvred-Faced Diffuser Option SONODEC 25 ACOUSTIC FLEX 4 WAY LOUVRED FACE DIFFUSER (LF6) SP3 FANCOIL UNIT 7

www.air-diffusion.co.uk www.actionair.co.uk Ordering Procedure LS Range Reference - SP2-LS Reference - SP3-LS Reference - SP4X-LS LF3 Range Reference - SP2-LF3 Reference - SP3-LF3 Reference - SP4X-LF3 LF6 Range Reference - SP2-LF6 Reference - SP3-LF6 Reference - SP4X-LF6 *225 x 225 active Please Note: All handings for pipework / controls are left hand only. Packages detailed include components as listed, refer to individual product specifications Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Systempac is available in 9 packages 2kW Thermal Output: 1 Size 2 Fan Coil Unit including:- 2 3 Slot Linear Diffusers (1195mm long), 2 Plenum Boxes 1 2m minimum length of Acoustic Flexible Ducting (200mm diameter) 3kW Thermal Output: 1 Size 3 Fan Coil Unit including:- 3 3 Slot Linear Diffusers (1195mm long), 3 Plenum Boxes 1 3m minimum length of Acoustic Flexible Ducting (200mm diameter) 4kW Thermal Output: 1 Size 4x Fan Coil Unit including:- 4 3 Slot Linear Diffusers (1195mm Long), 4 Plenum Boxes 1 4m minimum length of Acoustic Flexible Ducting (200mm diameter) 2kW Thermal Output: 1 Size 2 Fan Coil Unit including:- 2 4 Way Louvred-Faced Diffusers (373 x 373mm O/A), 2 Plenum Boxes 1 2m minimum length of Acoustic Flexible Ducting (200mm diameter) 3kW Thermal Output: 1 Size 3 Fan Coil Unit including:- 3 4 Way Louvred-Faced Diffusers (373 x 373mm O/A), 3 Plenum Boxes 1 3m minimum length of Acoustic Flexible Ducting (200mm diameter) 4kW Thermal Output: 1 Size 4X Fan Coil Unit including:- 4 4 Way Louvred-Faced Diffusers (373 x 373mm O/A), 4 Plenum Boxes 1 4m minimum length of Acoustic Flexible Ducting (200mm diameter) 2kW Thermal Output: 1 Size 2 Fan Coil Unit including:- 2 4 Way Louvred-Faced Diffusers (595 x 595mm Overall*), 2 Plenum Boxes 1 2m minimum length of Acoustic Flexible Ducting (200mm diameter) 3kW Thermal Output / 1 Size 3 Fan Coil Unit including:- 3 4 Way Louvred-Faced Diffusers (595 x 595mm Overall*), 3 Plenum Boxes 1 3m minimum length of Acoustic Flexible Ducting (200mm diameter) 4kW Thermal Output / 1 Size 4X Fan Coil Unit including:- 4 4 Way Louvred-Faced Diffusers (595 x 595mm Overall*), 4 Plenum Boxes 1 4m minimum length of Acoustic Flexible Ducting (200mm diameter) Optional Extras A. Remote room mounted set point adjuster / temperature sensor ( fitted by others). B. Additional 10m lengths of Sonodec25 acoustic flex. C. Return air packages using any of the diffusers shown above. as detailed on page 2. Systempac data is based upon the design data as detailed on pages 3 and 4. Any deviation will result in differing thermal / volumetric / acoustic performance Air Diffusion Limited, Birchwood Trading Estate, 164 Great North Road, Hatfield, Herts AL9 5JN Tel: (01707) 272601 Fax: (01707) 274951 International Code: +441707 Email: sales@air-diffusion.co.uk Website: www.air-diffusion.co.uk characteristics. Please specify Systempac reference (e.g. SP4X-LS) and package quantity required. Optional extra cost items are available, please contact our Customer Service Offices. Please refer to our websites for current prices or contact either Customer Service Office Quality System Certificate No 017 Assessed to ISO 9002 PRODUCED BY GRAPHIC PARTNERSHIP www.graphicpartnership.co.uk