www. ElectricalPartManuals. com INSTRUCTIONS DynAC Broke DESCRIPTION ADJUSTMENT MAINTENANCE The Alternating Current Dynamic Brake

Similar documents
www. ElectricalPartManuals. com INSTRUCTIONS INTERLOCKED MOTOR-DRIVEN OPERATING MECHANISM For No-Load Tap Changers DESCRIPTION OPERATION MAINTENANCE

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

www. ElectricalPartManuals. com MECHANICAL RELIEF DEVICE

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

Instructions for Replacing

UNION SERVICE SPECIFICATION NUMBER SU A

www. ElectricalPartManuals. com INSTRUCTIONS NO LOAD TAP CHANGER TYPE WSB-4 INSTALLATION OPERATION MAINTENANCE

Type SOQ Negative Sequence Time Overcurrent Relay

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

HOKKIM. Control & Protection Relays. giving you control. Utilization: Power Factor Regulator : 14-STEP CYCLIC POWER FACTOR REGULATOR.

the Interactive Catalog

www. ElectricalPartManuals. com

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

www. ElectricalPartManuals. com Instructions for Cast Resin Bushing, 15 KV & Below

4.0 OPERATION Type ITH-T Relay

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

PARTS & SERVICE MANUAL

Model HEA Multicontact Auxiliary

INSTRUCTION MANUAL. Series PROCUNIER SAFETY CHUCK CO. (Serial Nos. B4870 and higher. (Serial Nos. B9230 and higher

Instructions for De-Ion Air Circuit Breakers Types DM2R, DM2F

MOTOR DRIVE UNIT MA General Technical Data Design Control Circuit Assembly... 7

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

2006 MINI Cooper S GENINFO Starting - Overview - MINI

INSTRUCTIONS. seconds. the tween the end of the bearing screw and the. top of the shaft. The moving contact is a small silver hemisphere

PARTS BREAKDOWN FOR HIGH AND LOW SPEED GEAR ASSEMBLIES

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

www. ElectricalPartManuals. com Instructions for Type URF Step Voltage Regulator Westinghouse Electric Corporation

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators

FN-27 FLASHER RELAY SERVICE MANUAL 4519 * * * * * * * * * * * * * * * *

NUMBER: S.M. REF.: Refer to 2.5 ENGINE: 60 DATE: January 2007

Instruction Manual. for 14-V DC Option Kits Part No and Part No For Use With Hobart Series 7003B Jet-Ex 4 Diesel Generator Sets

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

P. Sub 4 184A404. Sub 3 876A220

B CW POWER RELAY

Common rail injection system

U STYLE "TP" TIME RELEASE UNION SWITCH & SIGNAL DIVISION OF WESTINGHOUSE AIR BRAKE CO. INSTALLATION AND MAINTENANCE AUGUST, 1951


THE AUXILIARY EQUIPMENT OF THE CHICAGO, MILWAUKEE AND ST. PAUL LOCOMOTIVES

1. Anti-lock Brake System (ABS)

COM Overcurrent Relay

AUTOTRANSFORMER-TYPE STARTERS ALLEN-BRADLEY COMPANY REPLACEMENT PARTS AND PROCEDURES

FG MACH I / MACH IIA OWNER S MANUAL AUTOMATIC BULK FEED PINSPOTTER MACHINERY DIVISION

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

ENGINE BRAKES. Application: CATERPILLAR 3406E C-15/C-16 ENGINES

AUTOMOTIVE ENGINEERING SECTION

SPEED CONTROL SYSTEM

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

CABINET REEL OPERATING INSTRUCTIONS

Wiring Diagrams (Including Accessories) (50/60 Hz)

Sensors & Controls. Everything you wanted to know about gas engine ignition technology but were too afraid to ask.

Jogging and Plugging of AC and DC Motors. Prepared by Engr. John Paul Timola, LPT

Basics of Control Components

Instruction Bulletin. Jockey Pump Controller

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

Motor-drive mechanism, type BUL. Technical guide

INDEX. 414 Agitator reversing mechanism which varies point of reversal. 250 Alternate and intermittent drive for two shafts

GE CONSUMER & INDUSTRIAL

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL C ELECTRIC HYDRAULIC PUMP

Exercise 4-1. Friction Brakes EXERCISE OBJECTIVE DISCUSSION. Understand the construction and operation of friction brakes.

Horizontal Circuit Switchers

IM K IM K. Instructions for Cutler-Hammer Jockey Pump Controllers

Horizontal Circuit Switchers

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

AUTOMATIC CLUTCH Models

Fisher 2506 and 2516 Receiver Controllers

INSTRUCTION MANUAL PROTECTIVE RELAY TEST SET MODEL SR-76A. For SERIAL NO.

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Electrical Control System Components Basics of Magnetic Control :

SD Bendix Manual Slack Adjusters DESCRIPTION ADJUSTING MECHANISM OPERATION

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

Horns, Wiper, and Washer System Operation

Tooling Assistance Center

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS

TM-1620 OPERATING INSTRUCTIONS AND OWNERS MANUAL

SERVICE MANUAL (INTERNATIONAL)

Application Engineering

Maintenance Instructions & Parts List

Eclipse 2000 Service Parts

INSTALLATION AND OPERATION MANUAL 14-V DC OPTION KITS

Motor-drive mechanisms, type BUL Spare parts list

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Euclid Full Voltage Magnet Controller

SUBSTATIONS. Energy Storage System

COLLATOR REFERENCE CONTENTS. Copyright 1947, ADJUSTMENTS. FeedHoppers... Feed Knives... FeedKnifeGuides... Card Guides... FeedRolls..-.. rn...

Starting of Induction Motors

SDC,Inc. SCR-Regenerative Ac Drive

10000AR X2 INSTALLATION MANUAL

Product design: Mechanical systems

BL7000 SYSTEM OPERATING MANUAL

Ch 4 Motor Control Devices

Service Bulletin Trucks

Programmable Logic Controller. Mat Nor Mohamad

MODULOAD CAPACITY CONTROL FOR 3D COMPRESSORS

Transcription:

I.L. 46-713-'2 DESCRIPTION MAINTENANCE INSTRUCTIONS FIG. 1. "DynAC Brake" As Installed on URS Cam Switch Assembly THE "DYNAC BRAKE" (pronounced "dineack") is a totally new means for the rapid deceleration of reversible capacitor type motors as used on tap changer drive mechanisms or other applications where quick acting electrical braking is required. The "DynAC Brake" operates instantly when driving power is removed to give a smooth application of braking power with a minimum of strain on the motor shaft. DESCRIPTION The "DynAC Brake" is available in two styles: "Type M" where mechanical operation is desirable (see Fig. 2), and "Type E" solenoid-operated for other applications (Fig. 3). NEW INFORMATION Trade-Mark DynAC Broke The Alternating Current Dynamic Brake * The "Type M DynAC Brake" consists of the "DynAC" time delay relay complete with the mounting bracket, a cam operated brake arm, and brake resistors. The time delay relay and mounting bracket constitute one assembly and the resistors constitute another assembly. These assemblies are mounted in the cam switch compartment (air chamber) of the tap changer. The "Type E DynAC Brake" consists of a solenoid operated time delay relay and its accompanying resistors mounted on a common base. It is normally mounted back of the control panel in the control compartment. The basic mechanism of both types is the "DynAC" time delay relay (Fig. 4). This is a pneumatically controlled device which gives an application of power for braking of exactly the right duration. It has a built-in overtravel feature on the bellows operating plunger to ensure proper operation at all times, without necessity of exacting travel adjustments. SEQUENCE OF OPERATION The contacts of the "DynAC" time delay relay are closed mechanically or electrically by the cam switch assembly of the tap changer. This sets up the braking circuit which is completed by the closing of the back contacts of the motor control relay when the relay is de-energized. The "DynAC Brake" thus applies single-phase a-c power directly to both windings of the motor from the same supply leads for a sufficient length of time (as determined by the time delay setting) to permit the motor to come to rest. This braking power is removed by the "DynAC" time delay relay, after the mechanical or electrical force, which closed the contacts, has been removed by the proper positioning of the tap changer. This gives alternating current dynamic braking action, bringing the motor to a quick, smooth stop. JANUARY, 1951

DYNAC BRAKE -- LINK SPRING OPERATION COUNTER BRAKE AND COUNTER OPERATING ARM CONTACT ASSEMBLY RESISTOR PANEL FIG. 2. "Type M DynAC Brake" for Mechanical Operation, with Mounting Bracket, Cam-Operated Brake Arm, and Brake Resistor Panel The only major adjustment necessary is on the length of the time delay. The time from the removal of pressure from the plunger until the opening of the contacts of the "DynAC" time delay relay (snapping of the switch) should be approximately o.1e half to one second. Turning the adjusting screw clockwise decreases the time delay, counter-clockwise increases the time delay. An approximate adjustment is_made by turning the adjusting screw to the maximum delay setting and then reducing the delay by four full turns of the adjusting screw. See.Fig. 4. The XR and XL resistors serve two functions. One function is to prolong the life of contacts "SLl" and "SR2" of the motor control relay by limiting the capacitor discharge current when the capacitors are short circuited by these contacts. The other function is to control the positioning of the cam switch rollers on the lobes of the cams. This fine adjustment, which in the majority of cases is not required, may be desirable because of slight variations in different motors and mechanisms or extremely wide variations in voltage supply. The resistance is divided between leads 124 and 125 to balance the braking torque in the two directions of operation. Increasing the XL resistance (Fig. 5) decreases the braking torque applied as the motor is stopped after an operation in the "Lower" direction, hence 2 the unit will stop with the "120" cam roller further onto the lobe of the "120" cam. Increasing the XR resistance gives the same effect in the raise direction. Since there is an interaction of the currents which pass through these resistors, it is sometimes necessary to readjust the XL resistance after the XR is adjusted, and vice versa. OPERATING - SOLENOID CONTACT ASSEMBLY RESISTORS FIG. 3. "Type E DynAC Brake", Solenoid-Operated, with Brake Resistors on Common Base

DYNAC BRAKE------------------------------------------------------- ' L -- 46 _- 7 _ 1 _. 3-7 FILTER FELT ---'-.. BRONZE SCREEN- -- RELAY WITH COVER AND FILTER REMOVED WITH COVER AND CONTACT ASSEMBLY REMOVED WITH PLUNGER AND TOGGLE IN NORMAL POSITION.., ADJUS TING SCREW-.:...---1' CONTAC T ASSEMBLY SHOWN IN THREE VIEWS STYLE 1608060 PLUNGER TOGG LE ADJUS TING SCREW RELAY STYLE 1590708 ELEMENT OF RELAY SHOWN WITH PLUNGER AND TOGGLE DEPRESSED FIG. 4. Various Views of "DynAC Brake" Time Delay Relay and Contact Assembly 3

DYNAC BRAKE -- MAINTENANCE The contacts of the time delay relay should be checked for cleanliness and future life at regular maintenance periods. It is recommended that this be done each time the selector contacts of the tap changer are inspected. accomplished by removal of the This inspection may be two mounting screws which fasten the contact assembly to the time delay mechanism. The plunger and toggle must be depressed when the contact assembly is being replaced (Fig. 4). In extremely dusty locations the time delay mechanism should be removed from its case by the removal of the four screws, two on each side of the case, and the case thoroughly cleaned. The bronze screen should be removed from the recess and the filter felt cleaned with carbon tetrachloride prior to assembly (Fig. 4). RENEWAL PARTS The following renewal parts are available from the Sharon Works, Westinghouse Electric Corporation, through the nearest Westinghouse Sales Office: Complete Solenoid Operated Time Delay Relay (110 Volt Coil).. Sf! 1590 746 (Fig. 7) Time Delay Unit.... Sf! 1590 708 (Fig. 4) Contact Assembly... S fil 1608 060 (Fig. 4) Resistor... Sf! 1590 776 (Fig. 5) FIG. 5. Resistor S!lll590 176 LL OPEN ON MAXIMUM BUCK POSITION LR OPEN ON MAXIMUM BOOST POSITION 124 CLOSED ON MAXIMUM BOOST POSITION 125 CLOSED ON MAXIMUM BUCK POSITION SL -SR MOTOR CONTACTOR CONTACTS BC "'DYNAC BRAKE"'CONTACT FIG. 6. SLI Schematic Diagram of "DynAC Brake" Connections FIG. 7. Complete Solenoid Operated Time Delay (110 Volt Coil) S!lll590 746 WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. (Rep. 2 58) LR Printed in U.S.A

I.L. 46-713-7 DESCRIPTION MAINTENANCE INSTRUCTIONS FIG. 1. "DynAC Brake" As Installed on URS Cam Switch Assembly THE "DYNAC BRAKE" (pronounced "dineack") is a totally new means for the rapid deceleration of reversible capacitor type motors as used on tap changer drive mechanisms or other applications where quick acting electrical braking is required. The "DynAC Brake" operates instantly when driving power is removed to give a smooth application of braking power with a minimum of strain on the motor shaft. DESCRIPTION The "DynAC Brake" is available in two styles: "Type M" where mechanical operation is desirable (see Fig. 2), and "Type E" solenoid-operated for other applications (Fig. 3). NEW INFORMATION Trade-Mark DynAC Brake The Alternating Current Dynamic Brake * The "Type M DynAC Brake" consists of the "DynAC" time delay relay complete with the mounting bracket, a cam operated brake arm, and brake resistors. The time delay relay and mounting bracket constitute one assembly and the resistors constitute another assembly. These assemblies are mounted in the cam switch compartment (air chamber) of the tap changer. The "Type E DynAC Brake" consists of a solenoid operated time delay relay and its accompanying resistors mounted on a common base. It is normally mounted back of the control panel in the control compartment. The basic mechanism of both types is the "DynAC" time delay relay (Fig. 4). This is a pneumatically controlled device which gives an application of power for braking of exactly the right duration. It has a built-in overtravel feature on the bellows operating plunger to ensure proper operation at all times, without necessity of exacting travel adjustments. SEQUENCE OF OPERATION The contacts of the "DynAC" time delay relay are closed mechanically or electrically by the cam switch assembly of the tap changer. This sets up the braking circuit which is completed by the closing of the back contacts of the motor control relay when the relay is de-energized. The "DynAC Brake" thus applies single-phase a-c power directly to both windings of the motor from the same supply leads for a sufficient length of time (as determined by the time delay setting) to permit the motor to come to rest. This braking power is removed by the "DynAC" time delay relay, after the mechanical or electrical force, which closed the contacts, has been removed by the proper positioning of the tap changer. This gives alternating current dynamic braking action, bringing the motor to a quick, smooth stop. JANUARY, 1951

DYNAC BRAKE -- LINK SPRING BRAKE AND COUNTER OPERATING ARM CONTACT ASSEMBLY RESISTOR PANEL FIG. 2. "Type M DynAC Brake" for Mechanical Operation, with Mounting Bracket, Cam-Operated Brake Arm, and Brake Resistor Panel The only major adjustment necessary is on the length of the time delay. The time from the removal of pressure from the plunger until the opening of the contacts of the "DynAC11 time delay relay (snapping of the switch) should be approximately o.1e half to one second. Turning the adjusting screw clockwise decreases the time delay, counter-clockwise increases the time delay. An approximate adjustment is made by turning the adjusting screw to the maximum delay setting and then reducing the delay by four full turns of the adjusting screw. See Fig. 4. The XR and XL resistors serve two functions. One function is to prolong the life of contacts "SL111 and "SR211 of the motor control relay by limiting the capacitor discharge current when the capacitors are short circuited by these contacts. The other function is to control the positioning of the cam switch rollers on the lobes of the cams. This fine adjustment, which in the majority of cases is not required, may be desirable because of slight variations in different motors and mechanisms or extremely wide variations in voltage supply. The resistance is divided between leads 124 and 125 to balance the braking torque in the two directions of operation. Increasing the XL resistance (Fig. 5) decreases the braking torque applied as the motor is stopped after an operation in the "Lower11 direction, hence 2 the unit will stop with the "120" cam roller further onto the lobe of the "120" cam. Increasing the XR resistance gives the same effect in the raise direction. Since there is an interaction of the currents which pass through these resistors, it is sometimes necessary to readjust the XL resistance after the XR is adjusted, and vice versa. CONTACT ASSEMBLY RESISTORS FIG. 3. "Type E DynAC Brake", Solenoid-Operated, with Brake Resistors on Common Base

DYNAC BRAKE----------------------------------------------------- ' Ḻ - 4 6-7 13-7 FILTER FELT--... BRONZE SCREEN -- RELAY WITH COVER AND FILTER REMOVED WITH COVER AND CON TACT ASSEMBLY REMOVED WITH PLUNGER AND TOGGLE IN NORMAL POSIT ION.... ADJUS TING SCREW--'-- CONTAC T ASSEMBLY SHOWN IN THREE VIEWS STYLE 1608060 PLUNGER GGLE ADJUSTING SCREW RELAY'.. ST YLE 1590708 ELEMENT OF RELAY SHOWN WITH PLUNGER AND TOGGLE DEPRESSED FIG. 4. Various Views of "DynAC Brake" Time Delay Relay and Contact Assembly 3

DYNAC BRAK--- MAINTENANCE The contacts of the time delay relay should be checked for cleanliness and future life at regular maintenance periods. It is recommended that this be done each time the selector contacts of the tap changer are inspected. This inspection may be accomplished by removal of the two mounting screws which fasten the contact assembly to the time delay mechanism. The plunger and toggle must be depressed when the contact assembly is being replaced (Fig. 4}. In extremely dusty locations the time delay mechanism should be removed from its case by the removal of the four screws, two on each side of the case, and the case thoroughly cleaned. The bronze screen should be removed from the recess and the Wter felt cleaned with carbon tetrachloride prior to assembly (Fig. 4). RENEWAL PARTS The following renewal parts are available from the Sharon Works, Westinghouse Electric Corporation, through the nearest Westinghouse Sales Office: Complete Solenoid Operated Time Delay Relay (110 Volt Coil).. S 1590 746 (Fig. 7} Time Delay Unit.... S 1590 708 (Fig. 4} Contact Assembly... S 1608 060 (Fig. 4} Resistor... S 1590 776 (Fig. 5} FIG. 5. Resistor S,;,: 1590 776 LL OPEN ON MAXIMUM BUCK POSITION LR OPEN ON MAXIMUM BOOST POSITION 124 CLOSED ON MAXIMUM BOOST POSITION 125 CLOSED ON MAXIMUM BUCK POSIT/ON SL -SR MOTOR CONTACTOR CONTACTS BC "DYNAC BRAKE"CONTACT FIG. 6. Schematic Diagram of "DynAC Brake" Connections FIG. 7. Complete Solenoid Operated Time Delay (110 Volt Coil} s,;,: 1590 746 WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. (Rep. 2-58) Printed in U.S.A

I.L. 46-713-7 DESCRIPTION MAINTENANCE INSTRUCTIONS FIG. I. "DynAC Brake" As Installed on URS Cam Switch Assembly THE "DYNAC BRAKE" (pronounced "dineack") is a totally new means for the rapid deceleration of reversible capacitor type motors as used on tap changer drive mechanisms or other applications where quick acting electrical braking is required. The "DynAC Brake" operates instantly when driving power is removed to give a smooth application of braking power with a minimum of strain on the motor shaft. DESCRIPTION The "DynAC Brake" is available in two styles: "Type M" where mechanical operation is desirable (see Fig. 2), and ''Type E" solenoid-operated for other applications (Fig. 3). NEW INFORMATION * Trade-Mark DynAC Brake The Alternating Current Dynamic Brake * The "Type M DynAC Brake" consists of the "DynAC" time delay relay complete with the mounting bracket, a cam operated brake arm, and brake resistors. The time delay relay and mounting bracket constitute one assembly and the resistors constitute another assembly. These assemblies are mounted in the cam switch compartment (air chamber) of the tap changer. The "Type E DynAC Brake" consists of a solenoid operated time delay relay and its accompanying resistors mounted on a common base. It is normally mounted back of the contml panel in the control compartment. The basic mechanism of both types is the "DynAC" time delay relay (Fig. 4). This is a pneumatically controlled device which gives an application of power for braking of exactly the right duration. It has a built-in overtravel feature on the bellows operating plunger to ensure proper operation at all times, without necessity of exacting travel adjustments. SEQUENCE OF OPERATION The contacts of the "DynAC" time delay relay are closed mechanically or electrically by the cam switch assembly of the tap changer. This sets up the braking circuit which is completed by the closing of the back contacts of the motor control relay when the relay is de-energized. The "DynAC Brake" thus applies single-phase a-c power directly to both windings of the motor from the same supply leads for a sufficient length of time (as determined by the time delay setting) to permit the motor to come to rest. This braking power is removed by the "DynAC" time delay relay, after the mechanical or electrical force, which closed the contacts, has been removed by the proper positioning of the tap changer. This gives alternating current dynamic braking action, bringing the motor to a quick, smooth stop. EFFECTIVE JANUARY, 1951

DYNAC BRAKE -- LINK SPRING BRAKE AND COUNTER OPERATING ARM CONTACT ASSEMBLY TIM DELAY RESISTOR PANEL FIG. 2. "Type M DynAC Brake" for Mechanical Operation, with Mounting Bracket, Cam-Operated Brake Arm, and Brake Resistor Panel The only major adjustment necessary is on the length of the time delay. The time from the removal of pressure from the plunger until the opening of the contacts of the "DynAC" time delay relay (snapping of the switch) should be approximately one half to one second. Turning the adjusting screw clockwise decreases the time delay, counter-clockwise increases the time delay. An approximate adjustment is made by turning the adjusting screw to the maximum delay setting and then reducing the delay by four full turns of the adjusting screw. See Fig. 4. The XR and XL resistors serve two functions. One function is to prolong the life of contacts "SLl" and "SR2" of the motor control relay by limiting the capacitor discharge current when the capacitors are short circuited by these contacts. The other function is to control the positioning of the cam switch rollers on the lobes of the cams. This fine adjustment, which in the majority of cases is not required, may be desirable because of slight variations in different motors and mechanisms or extremely wide variations in voltage supply. The resistance is divided between leads 124 and 125 to balance the braking torque in the two directions of operation. Increasing the XL resistance (Fig. 5) decreases the braking torque applied as the motor is stopped after an operation in the "Lower" direction, hence 2 the unit will stop with the "120" cam roller further onto the lobe of the "120" cam. Increasing the XR resistance gives the same effect in the raise direction. Since there is an interaction of the currents which pass through these resistors, it is sometimes necessary to readjust the XL resistance after the XR is adjusted, and vice versa. OPERATING ----SOLENOID FIG. 3. "Typo E DynAC Brake", Solenoid-Operated, with Brake Resistors on Common Base

DYNAC BRAKE---------------------------------------------------- -. L - 4 _ 6-7 - U._- 7 FILTER FELT--... BRONZE SCREEN _.. RELAY WITH COVER AND FILTER REMOVED WITH COVER AND CONTACT ASSEMBLY REMOVED WITH PLUNGER AND TOGGLE IN NORMAL POSITION ADJUSTING SCREW ---: CONTACT ASSEMBLY SHOWN IN THREE VIEWS STYLE 1608060 TOGGLE ADJUSTING SCREW RELAY STYLE 1590708 ELEMENT OF RELAY SHOWN WITH PLUNGER AND TO GGLE DEPR ESSED FIG. 4. Various Views of "DynAC Brake" Time Delay Relay and Contact Assembly 3

DYNAC BRAKE -- MAINTENANCE The contacts of the time delay relay should be checked for cleanliness and future life at regular maintenance periods. It is recommended that this be done each time the selector contacts of the tap changer are inspected. This inspection may be accomplished by removal of the two mounting screws which fasten the contact assembly to the time delay mechanism. The plunger and toggle must be depressed when the contact assembly is being replaced (Fig. 4). In extremely dusty locations the time delay mechanism should be removed from its case by the removal of the four screws, two on each side of the case, and the case thoroughly cleaned. The bronze screen should be removed from the recess and the filter felt cleaned with carbon tetrachloride prior to assembly (Fig. 4). RENEWAL PARTS The following renewal parts are available from the Sharon Works, Westinghouse Electric Corporation, through the nearest Westinghouse Sales Office: Complete Solenoid Operated Time Delay Relay (110 Volt Coil).. S)lji 1590 746 (Fig. 7) Time Delay Unit.... S)lji 1590 708 (Fig. 4) Contact Assembly... S)lji 1608 060 (Fig. 4) Resistor... S)lji 1590 776 (Fig. 5) FIG. 5. Resistor Sill 1590 776 LL OPEN ON MAXIMUM BUCK POSITION LR OPEN ON MAXIMUM BOOST POSITION 124 CLOSED ON MAXIMUM BOOST POSITION 125 CLOSED ON MAXIMUM BUCK POSITION SL -SR MOTOR CONTACTOR CONTACTS BC "DYN AC BRAKE"CONTACT FIG. 6. SLI Schematic Diagram of "DynAC Brake" Connections FIG. 7. Complete Solenoid Operated Time Delay (110 Volt Coil) Sill 1590 746 WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. (Rep. 1-52) LR Printed in U.S.A.