Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB

Similar documents
Type ICX Outdoor open type cutout

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Medium Voltage Outdoor Apparatus Portfolio 2009

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

GROUP D. Switch & Protective device.

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015

AutoLink Frequently Asked Questions

PRODUCT CATALOGUE. Overhead System

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

Q pole Pole Mounted Capacitor System

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Three-Phase Pole Mounted Recloser

100 / 110 DRYWELL FUSE SPECIFICATION

Figure 1. HX cutout fuseholders.

Figure 1. HX cutout fuseholders. Positive Interruption

شركة كهرباء محافظة القدس المساهمة المحدودة

10DD 10DD-1. Section CAUTION:

Product Group Brochure. PS Range Capacitor Vacuum Switches

34-SDMS-01 SPECIFICATIONS FOR

S&C Manual PME Pad-Mounted Gear

Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526

Electronic Resettable Sectionalizer

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

WLI Medium Voltage Switchgear Renewal Parts

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

S&C Loadbuster Disconnects

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

TYPE BLT DISCONNECT SWITCHES

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

26.3. Power Breakers, Contactors and Fuses. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.

NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice.

3EK7 Medium Voltage Silicone Insulated Surge Arresters

M-Force three-phase switch

Product Selection Guide

Disconnect & ByPass Switches

Surge Arresters. Surge Arrester/Type L Fuse Cutout Combination. Description. Construction. Connectors/Brackets

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

S&C Type XS Fuse Cutouts

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

Technical Specification for Pole Mounted Capacitor Rack

JUMPERS & SWITCHING TOOLS

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

Product Specifications for Phase Over Phase GOABS(r)

Advance 27 ANSI 27 kv switchgear

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

Cobra-S. Catalog Cobra-S

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Section 1 Introduction to the Presentation

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Product Specifications for Aluminum Vertical Break Switches

Kuhlman Electric Corporation Volt Instrument Transformers

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break

S&C Type XS Fuse Cutouts

Epoxy Technology Embedded Poles

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

EE 741 Over-voltage and Overcurrent. Spring 2014

Kuhlman Electric Corporation Volt Instrument Transformers

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

RBA Catalog Numbers and Information

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Solar Combiner Solutions

M-Force three-phase switch

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

OVR Three Phase Recloser 15 kv - 38 kv. Descriptive Bulletin

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

Underground Distribution Switchgear

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

Padmount Solid Dielectric Switchgear Catalog

Type IMC Indoor current transformer

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Unitized Quick Install Switches for Transmission Applications

K-Limiter high ampere Companion II fuse

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Surge Arresters. Supply Program. Answers for energy.

POWER SYSTEMS, INC. CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

Transcription:

Type ICX Interchangeable Cutout 15-38 kv Outdoor Distribution Cutout Product Bulletin 1VAG271201-DB

Product Features 15, 27, or 38 kv 110, 125, 150, 180, or 200 kv BIL 100 A, 200 A Fused 300 A Disconnect Blade Porcelain, Silicone, or Polymer Concrete Insulators Available Seacoast Design ECD (Emission Control Device) Cutout/Arrester Combo Kick-out Spring Description The ABB ICX interchangeable cutout is used on overhead distribution systems to provide overcurrent protection and visible indication of fuse operation. The ICX provides a visible break sectionalizing point for maintenance personnel and is equipped with hooks to use with a portable loadbreak tool. This allows the ICX to be used as a loadbreak switch to open the circuit with load current flowing. Silicone or Polymer Concrete insulators, Emission Control Devices (ECDs), Seacoast design, cutout/arrester combinations, and Autolink options are available on certain models. s The ICX cutout is offered in three frame sizes and five BIL ratings. Each of the frames accommodates fuseholders with various ratings. ICX ratings are 110 kv through 200 kv BIL. Application The ICX 100 A fuse is provided with a moisture proof tube as a standard offering. Cutouts perform by expelling gases during interruption from the bottom of the fuse tube. For the highest interrupting rating, a link extender rod is attached to the fuse tube cap, improving the efficiency of gas expulsion and arc interruption. Fuse tubes with more than one rating are clearly labeled to indicate each interrupting capability. This minimizes the number of styles that must be stocked, while providing the broadest range of application flexibility. Interchangeability The ICX cutout is designed to be electrically and mechanically interchangeable with the S&C type XS, A.B. Chance type C, and Cooper type L cutouts. Fuseholder caps are also interchangeable with the S&C design. Testing has confirmed the performance of the ICX fuseholder and fuse support with S&C and Chance. ICX cutout with arrester combination Standards and Design Testing The ICX cutout meets or exceeds all applicable requirements of EEI, NEMA SG-2-1986, and ANSI C37.41.1994 and C37.42-1989 standards. 15 kv ICX polymer concrete ICX with ECD - 2 -

Options Silicone Rubber Silicone rubber has been used for more than 25 years as an outdoor insulation material and has become the fastest growing choice for polymeric material for medium and high voltage outdoor insulation. Silicone was selected for its superior performance, durability, and insulation properties. It has the unique ability to maintain its hydrophobicity and offers greater stability against heat and ultraviolet radiation compared to other polymers. In addition, cutouts are 30% - 50% lighter than units. Silicone insulators are available in all ratings up to 180 kv BIL. Polymer Concrete ABB has been using polymer concrete for more than 10 years. It is available in the 110 and 125 kv BIL ratings. Polymer concrete provides a safe, shatter-proof design with molded-in rods to prevent moisture penetration. Polymer concrete is cold weather friendly since it resists damage from freeze/thaw cycles. This makes it an excellent replacement for in colder climates. It is a field-proven material that provides excellent electrical properties and dielectric strengths, as well as superior mechanical durability. ICX with ECD The ICX is available with an Emission Control Device (ECD). The ECD prevents forest fires and provides added operator and environment protection. The unlatching operation of the dropout is unique in the ECD, as it automatically resets to the service position upon closing the dropout carrier. Kick-out Spring All ICX fuse tubes are available with an optional kick-out spring. The spring assists the drop-out operation by increasing the kick-out force on the tube. Construction Details Fuse Tube Construction The ICX cutouts utilize two different types of fuse tubes: a moisture-proof fuse tube or a high-strength glass fuse tube. The moisture proof fuse tube is standard on all 100 A designs and is notated by the letter "M" in the 8th digit of the style number (refer to Ordering Instructions on pages 6-7). The moisture-proof tube reduces swelling that can create problems with interruption. The 200 A design utilizes a high-strength glass fuse tube and is notated by the letter "A" in the 8th digit of the style number (refer to Ordering Instructions on pages 6-7). This fuse tube is composed of a horn fiber liner surrounded by a glass filament wound outer shell. The durable tube withstands the rigors of high fault current interruptions. In addition, the tube is applied with electrostatic powder paint to provide protection against the effects of ultraviolet rays. Voltage Levels Single voltage rated cutouts can be applied on any single or three-phase system where the line-to-line voltage does not exceed the cutout rating. Dual voltage rated cutouts are suitable on single-phase circuits where maximum line-to-ground voltage does not exceed the value shown to the right of the slash (for example, does not exceed 27 kv in 15/27 kv). ICX cutouts may be used on three-phase circuits that are solidly grounded and the maximum line-to-line voltage does not exceed the value shown to the left of the slash (for example, does not exceed 7.8 kv in 7.8/15 kv). Each frame size has fault interrupting ratings at more than one voltage level. An extensive testing program was performed to develop these multi-voltage capabilities. As a result of this program, the voltage rating of some ICX cutouts may be increased by changing the fuseholder. 27 kv ICX with Autolink 27 kv Silicone ICX with 300 A blade (600 mm creep) 15 kv ICX - 3-27 kv Silicone ICX (180 kv BIL)

Unit Dimensions A B 2.25 [57].312 NEMA "A" BRKT.375 NEMA "B" BRKT 3.0-4.0 [76-102] C 4.12-5.12 [105-130] 7.75 [197] 1.56 [40] F R D 17-20 DEG 1.00 [25] E Note: Metric dimensions are displayed in [mm]. kv BIL Unit Dimensions (in) Creep* Weight* Class (kv) A B C D E F R (in) (lb) 15 110 12.79 7.33 6.50 8.55 6.60 11.41 9.1 14.0 27 125 13.30 7.84 8.17 10.25 6.08 14.88 12.8 20.0 27 or 38 150 13.30 7.84 8.17 10.25 6.08 14.88 17.0 26.5 27 or 38 170 13.96 8.51 10.42 13.00 5.27 19.21 26.2 35.5 BIL Unit Dimensions (mm) Creep* (kv) A B C D E F R (mm) 15 110 325 186 165 217 168 290 231 6.4 kv Class Weight* (kg) 27 125 338 199 208 260 154 378 325 9.0 27 or 38 150 338 199 208 260 154 378 432 12.0 27 or 38 170 356 216 265 330 134 488 665 16.1 * Creep and weight values are for standard units. - 4 -

Bracket Dimensions.312 [8].375 [10] 7.8 [198] 7.8 [198] 1.6 [40] 1.6 [40] 2.6 [67] 2.6 [67] NEMA A bracket NEMA B bracket.38 [10] 7.8 [198] 12.8 [325] 9.1 [231] 1.5 [38] 5.4 [137] 6.9 [175] 2.2 [56] Extended bracket Pole Mounting bracket Part numbers listed on page 8. Note: Metric dimensions are displayed in [mm]. - 5 -

Ordering Instructions ICX 15 kv DIGIT 4 Terminal Connectors DIGIT 6 Special Options DIGIT 11 Additional Options DIGIT 2 Insulator BIL 1 = 110 kv N = No terminal C = Clamshell E = Eyebolt N = None F = Wildlife guard Y = Combo box K = Kickout spring on fuse tube X 1 DIGIT 3 Fuse Support N = Porcelain J = Silicone Z = Polymer concrete E = Emission control DIGIT 5 Bracket N = No bracket A = NEMA A B = NEMA B L = Extended U = Pole Mounting DIGITS 7-10 Fuseholder AM11 = 100A, 10kAIC, Solid cap LM11 = 100A, 16kAIC, Link extender KA21 = 200A, 12kAIC, Link extender PA21 = 200A, 10kAIC, Link extender (rated 7.8/15 kv) CA31 = 300A, Solid blade ICX 27 kv DIGIT 2 Insulator BIL 2 = 125 kv BIL 4 = 150 kv BIL 600 mm creep ( only) 5 = 150 kv BIL 8 = 180 kv BIL 750 mm creep ( only) 9 = 200 kv BIL 1130 mm creep ( only) DIGIT 4 Terminal Connectors N = No terminal C = Clamshell E = Eyebolt DIGIT 6 Special Options N = None F = Wildlife guard Y = Combo box DIGIT 11 Additional Options K = Kickout spring on fuse tube X DIGIT 3 Fuse Support N = Porcelain J = Silicone Z = Polymer concrete (125 BIL only) E = Emission control DIGIT 5 Bracket N = No bracket A = NEMA A B = NEMA B L = Extended U = Pole Mounting DIGITS 7-10 Fuseholder AM12 = 100A, 8kAIC, Solid cap GM12 = 100A, 12kAIC, Link extender MM12 = 100A, 16kAIC, Link extender VA22 = 200A, 12kAIC, Link extender WA22 = 200A, 12kAIC, Link extender (rated 15/27 kv) DA32 = 300A, Solid blade - 6 -

ICX 38 kv, 150 or 180 kv BIL DIGIT 2 Insulator BIL 4 = 150 kv BIL 600mm creep ( only) 5 = 150 kv BIL 8 = 180 kv BIL 750mm creep ( only) DIGIT 4 Terminal Connectors N = No terminal C = Clamshell E = Eyebolt DIGIT 6 Special Options N = None F = Wildlife guard Y = Combo box DIGIT 11 Additional Options K = Kickout spring on fuse tube X DIGIT 3 Fuse Supports N = Porcelain J = Silicone E = Emission control DIGIT 5 Bracket N = No bracket A = NEMA A B = NEMA B L = Extended U = Pole Mounting DIGITS 7-10 Fuseholder TA12 = 100A, 10kAIC, Link extender DA32 = 300A, Solid blade ICX 38 kv, 170 kv BIL DIGIT 4 Terminal Connectors DIGIT 6 Special Options DIGIT 11 Additional Options DIGIT 2 Insulator BIL 7 = 170 kv N = No terminal C = Clamshell E = Eyebolt N = None F = Wildlife guard Y = Combo box K = Kickout spring on fuse tube X 7 DIGIT 3 Fuse Supports N = Porcelain DIGIT 5 Bracket N = No bracket A = NEMA A B = NEMA B L = Extended U = Pole Mounting DIGITS 7-10 Fuseholder RA15 = 100A, 10kAIC, Link extender FA34 = 300A, Solid blade RA14 = 100A, 12kAIC, Link extender (tube rated for 27 kv) SA24 = 200A, 10kAIC, Link extender (tube rated for 15/27 kv) - 7 -

Optional Cutout Parts Replacement Fuseholders Style Number Voltage (kv) BIL (kv) Current (A) Interrupting (kaic) Cap Type Corresponding Cutout* 7194C60G01MP 15 110 100 10 Solid AM11 7194C60G02MP 15 110 100 16 Link Extender LM11 7194C60G03 7.8/15 110 200 12 Link Extender PA21 7194C60G04 15 110 300 - Solid Disconnect Blade CA31 7194C60G05MP 27 125 or 150 100 8 Solid AM12 7194C60G06MP 27 125 or 150 100 12 Link Extender MM12 7194C60G07 15/27 125 or 150 200 10 Solid BA22 7194C60G08 27 125 or 150 300 - Solid Disconnect Blade DA32 7194C60G08 38 150 300 - Solid Disconnect Blade DA32 7194C60G11MP 27 170 100 12 Link Extender MM13 7194C60G12MP 38 170 300 - Solid Disconnect Blade EA33 7194C60G19 15 110 200 10 Link Extender KA21 7194C60G26 27 125 or 150 200 12 Link Extender VA22 * Used with ICX cutouts having the following characters in digit positions 7-10 of the ABB cutout style number. Replacement Fuseholder Caps Style Number Voltage (kv) BIL (kv) Current (A) Interrupting (kaic) Cap Type 3A31186H01 15 110 100 10 Solid Cap 9861A62G05 15 110 100 16 Link Extender 9861A62G08 7.8/15 110 200 12 Link Extender 3A31187H01 15/27 125 or 150 200 10 Solid Cap 3A31186H01 27 125 or 150 100 8 Solid Cap 9861A62G06 27 125 or 150 100 12 Link Extender 9861A62G07 27 170 100 12 Link Extender Brackets Style Number 367C723G05 403A101G03 367C802G04 791C890G16 Type NEMA A NEMA B Extended Pole Mounting 1VAG271201-DB Rev. A December 2004 (replaces 38-631) Copyright 2004 ABB. All rights reserved. ABB Inc. 406 Banner Ave. Greensboro, NC 27401 Tel: +1-336-275-7310 www.abb.com/mediumvoltage