OPERATOR ADAPTER ABBSV

Similar documents
OPERATOR ADAPTER ABF

OPERATOR ADAPTER WAMTF

OPERATOR ADAPTER A21ABA

OPERATOR ADAPTER A21ITE

OPERATOR ADAPTER A21WHAMTA

SEQUESTR. External Disconnect Enclosure. Rev. A 2014 Pentair Equipment Protection PH hoffmanonline.com P/N

SEQUESTR. External Disconnect Enclosure. Rev. C 2013 Pentair Equipment Protection PH hoffmanonline.com P/N

Standard Product Low Profile Type 12 One-Door Disconnect Enclosures

THE ENCLOSURE HARDWARE SUPPLIER

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Classic12 Belt Sander

Cable-Operated Disconnect Switches. Accessories

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices

Photo 1. Shift pattern gate plate

INSTRUCTIONS INSTRUCCIONES CONSIGNES

INSTRUCTION, HALDEX PUMP LVS KIT P/N

Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12

Sunfire Series. Full Size Electric Convection Ovens. Parts List. Models SCO-ES-10S SCO-ES-20S. Document Number: S_EO_PL_CONVECTION_SCOES Updated: 2/15

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Installation Instructions Street Bandit Shifter

PARTS LIST WRANGLER 2625 DB

Preferred Cutout, Disconnect Enclosure, Type 12

PARTS LIST WRANGLER 26-VS

MK IV OVERHEAD DOOR REPLACEMENT PARTS BOOK

PARTS LIST WRANGLER 2625 DB

Technical Support (707)

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F

SECTION 6 PARTS LIST

Ref Qty Part Description Part Number -1- Kit ( ) Contents:

Mete-R-Matic F18 Top Dresser Starting Serial Number (U.S.A. Patent No. 5,307,952)

P/N Rev 01 04/14-1- NOTE: If you are ordering hinges for your rear doors, order and/or

INSTALLATION INSTRUCTIONS

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

MODEL NUMBER DESIGNATION 9-0 XX X X

Full Subpanel. Additional Mounting Hardware

Installation Instructions Unimatic Shifter

BEARING GUIDE. Bearing Guide Created by REV Robotics 2016, Licensed Under CC BY-SA 1

PARTS MANUAL. PS314SBI Gas and Electric Ovens. Models: for domestic and standard export ovens PS314SBI Middleby Marshall, Inc.

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

CATALOG OF REPLACEMENT PARTS

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

Z-Gate Universal Shifter

FloorCrafter Belt Sander

INSTRUCTION PLASTIC BATTERY BOX & CHARGER KIT

Rear Roller Brush Kit Greensmaster 3150 & 3250

Magnesium Option, Late Model Front Seal, Viton, P/N 67256V Rear Seal, Viton, P/N 67257V Shifter Installed Heat Treated Yoke, P/N

I Illustrated Parts List 8024 ST (HU8024STA), Snow Thrower. Repair Parts Manual

TCI FastGate Shifter Installation Instructions

Installation Instructions Unimatic Shifter

CCP2-FLR1-21_ flange-rod operating mechanism

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

Illustrated Parts List

OPERATOR S MANUAL MAINTENANCE MANUAL PARTS LIST TURFCO METE-R-MATIC III. Top Dresser. Model F12D. Product Number 85423

Parts Catalog. Spiral Mixer. Model:

CATALOG OF REPLACEMENT PARTS W32/W32C/625A WRAP STATION ML-44103, ML ML-44105, ML ML-26243

INSTALLATION INSTRUCTIONS

CATALOG OF REPLACEMENT PARTS

Illustrated Parts List I Snow Thrower 8527STE (HL8527STE A), Repair Parts Manual

REPAIR PARTS SNOW THROWER - MODEL NUMBER PP5524ESA AUGER HOUSING / IMPELLER ASSEMBLY

PARTS LIST WRANGLER 2625 DB

Summit Electric Convection Ovens

Summit Series. Full Size Electric Convection Ovens. Parts List. Models SUME-100 SUME-200

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

Parts Catalog. S-Series Slicer Automatic. Model:

CATALOG OF REPLACEMENT PARTS

ADVANCE ADAPTERS INC. P/N: VORTEC GEN. III V8 SQ. BOLT TJ WRANGLER MOTOR MOUNTS (WITH A/C)

Illustrated Parts List

Parts Catalog. S-Series Slicer Standard Automatic Frozen Option S13A. Model:

Large Enclosure Safe Handling Requirements. Do not reposition until permanently installed.

(W) INSTALLATION INSTRUCTIONS 90DEG BENT END SIDEBARS F-150 SUPER CREW CAB PART #DZ /DZ /DZ

Installation Instructions COMPETITION/PLUS SHIFTER Ford Mustang MT82 6-Speed Manual Transmission Catalog#

Parts Manual STRIKER PN Striker 2010 Parts List - Printed in USA 03/20/08

INSTALLATION SAFETY PRECAUTIONS OF ROAD WHEELS AND TIRES

Master Series Half Size Electric Convection Oven

Installation Instructions Z-Gate Shifter

Hopper and Drive Components

REPAIR PARTS MANUAL MODEL NUMBER PM105B Snow Thrower Rev BY Printed in U.S.A.

Technical Support (707)

Installation Instructions StarShifter

5524 ST. Spare parts Ersatzteile Pièces détachées Reserve onderdelen Repuestos Reservdelar I S E R V I C E IPL, 5524 ST, ,

Parts Catalog MIXER MODEL: SP8-RL

ELECTRIC START KIT KIT P/N

PARTS LIST CHARGER 2717 DB

REPAIR PARTS SNOW THROWER - MODEL NUMBER PP8527ESA AUGER HOUSING / IMPELLER ASSEMBLY

AFD-280U Parts List AFD-280U. (350 gm) (450 gm) (700 gm)

INSTALLATION INSTRUCTIONS

AccuGlide. HST 3-Inch HST 3-Inch Taping Heads. Instructions and Parts List. Important Safeguards. Important. Type 29100

CATALOG OF REPLACEMENT PARTS

Parts Manual PZ Please read the operator manual carefully and make sure you understand the instructions before using the machine.

24in Stand-On Aerator

Retriever 360G/P. 5/92 revised 2/01 FORM NUMBER

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

PARTS LIST CHARGER 2020 AB CHARGER 2020 DB

LoMax 205 CASE & 3:1 GEAR SET. Manufactured by JB CONVERSIONS, INC. Phone: Installation Instructions for the GM NP205 Transfer Case

Disconnect Enclosures

PARTS LIST CHARGER 2022 DB

DODGE RAM 2500

Parts Catalog. S-Series Slicer Standard Automatic S13A. Model:

Transcription:

OPERATOR ADAPTER ABBSV Installation Instructions for ABB Variable Depth, Small Handle, Disconnect Switches (For parts list, see Page 2) Rev. B 2018 Hoffman Enclosures Inc. PH 7634222211 nvent.com/hoffman P/N 89114659 89115499

The functions, fits and clearances of the installation described hereon are calculated from information supplied by the manufacturers of the equipment to be installed. Be certain to check the function, fits and clearances of all equipment both before and after installation to assure that it operates properly and safely and meets all applicable codes, standards and regulations. In the event the completed installation does not function properly or fails to meet any such codes, standards or regulations, do not attempt to make alterations or operate the equipment. Report such facts immediately to: Hoffman Customer Service 2100 Hoffman Way Anoka, MN 55303 763.422.2211 http://hoffman.nvent.com/contact-us Parts List Operator Adapter, Catalog Number ABBSV, for ABB Variable Depth, Small Handle, Disconnects Item No. Description Part No. Qty. 1 MOUNTING PLATE 26385001 1 2 PLATE GASKET 89109613 1 3 SCREW, 1/4-20X1/2 PAN HEAD 99401031 4 4 SLIDE ARM 26250001 1 5 SHOULDER COLLAR 26149001 1 6 SCREW, 1/4-20X7/8 HEX HEAD 99401030 1 7 LOCKWASHER, 1/4 SPRING 99401318 1 8 WASHER, FLAT 22101003 2 9 LOCKWASHER, 1/4 INTERNAL TEETH 99401300 2 10 NUT, 1/4-20 HEX 99401406 2 11 DOOR CATCH, ABB 89114410 1 12 SCREW, 10-32X3/8 PAN HEAD 99401007 2 13 LOCKWASHER, #10 INTERNAL TEETH 99401307 2 14 NYLON WASHER 26132003 4 15 INSTALLATION INSTRUCTIONS 89114652 1-2 - 2018 Hoffman Enclosures Inc. PH 763 422 2211 nvent.com/hoffman 89115499

INTRODUCTION This installation instruction is for ABB Variable Depth, Small Handle, mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman two door floor mounted, Bulletin A21 enclosures with the disconnect on the right flange. INSTALLATION STEPS Step 1 Install mounting plate (item1) and plate gasket (item 2) on the inside of the enclosure, behind the rectangular opening provided. Gasket side with PSA should be attached to the adapter plate. Secure in place with four screws (item 3) and four nylon washers (item14). Step 2 Discard the ABB spring bracket which is normally installed inside the enclosure flange, behind the ABB handle mechanism. Step 3 Assemble the ABB handle mechanism to the mounting plate which was installed in the enclosure in step 1. Omit cap screw and lockwasher which fits into bottom hole of the handle mechanism. Step 4 Install the slide arm (item 4) over the defeater part of the handle assembly (on ABB handle mechanism) with notch toward door opening, as shown. Place the smaller diameter end of the shoulder collar (item 5) through the oval slot in the slide arm. Install long cap screw (item 6) with lockwasher (item 7) through shoulder collar into the bottom mounting hole of the ABB handle mechanism and tighten. The slide arm and defeater should move up and down smoothly. Install door hasp (ABB part) per ABB instructions. Step 5 Attach the bottom of the slide arm (item 4) to the offset arm of the lock release mechanism. Use two flat washers (item 8), two lockwashers (item 9), and two hex nuts (item 10). Do not tighten until parts are adjusted. (see step 6B). Step 6 The handle safety lock release mechanism is adjustable in two places. (A) Check the adjustment of the factory installed roller bracket. The door latch should hit against the latch stop portion of the roller bracket when the door is closed and latched. Adjust up or down if necessary. The attached mechanism will then provide the necessary up down motion required to operate the release mechanism in the ABB handle mechanism. (B) Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock(on ABB handle mechanism) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late. Step 7 Attach the door catch (item 11), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Use two screws (item 12) and lockwashers (item 13). The door catch prevents the door from being opened when the handle mechanism is in the ON position. Step 8 Drill and tap holes in panel per ABB instructions. See ABB instructions for locating extra holes for fuse clips. Step 9 Mount switch or circuit breaker using ABB instructions and parts. ABB connecting rod must be cut off per ABB instructions. 89115499 2018 Hoffman Enclosures Inc. PH 763 422 2211 nvent.com/hoffman - 3 -

For Floor-Mounted, Two-Door Enclosures with Disconnect on Right Flange - 4-2018 Hoffman Enclosures Inc. PH 763 422 2211 nvent.com/hoffman 89115499

INTRODUCTION This installation instruction is for ABB Variable Depth, Small Handle, mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman one through six door, free standing Bulletin A28M1, A34Y and A4L3D enclosures with the disconnect on the right flange. INSTALLATION STEPS Step 1 Install Mounting plate (item 1) and plate gasket (item 2) on the inside of the enclosure, behind the rectangular opening provided. Gasket side with PSA should be attached to the adapter plate. Secure in place with four screws (item 3) and four nylon washers (item 14). Step 2 Discard the ABB spring bracket which is normally installed inside the enclosure flange behind he ABB handle mechanism. Step 3 Assemble the ABB handle mechanism to the mounting plate which was installed in the enclosure n step 1. Omit cap screw and lockwasher which fits into bottom hole of the handle mechanism. Step 4 Install the slide arm (item 4) over the defeater part of the handle assembly (on ABB handle mechanism) with notch toward door opening, as shown. Place the smaller diameter end of the shoulder collar (item 5) through the oval slot in the slide arm. Install long cap screw (item 6) with lockwasher (item 7) through shoulder collar into the bottom mounting hole of the ABB handle mechanism and tighten. The slide arm and defeater should move up and down smoothly. Install door hasp (ABB part) per ABB instructions. Step 5 Attach the bottom of the slide arm (item 4) to the offset arm of the lock release mechanism. Use two flat washers (item 8), two lockwashers (item 9), and two hex nuts (item 10). Do not tighten until parts are adjusted. (see step 6B) Step 6 The handle safety lock release mechanism is adjustable in two places. (A) Check the adjustment of the factory installed roller bracket. The door latch should hit against the latch stop portion of the roller bracket when the door is closed and latched. Adjust up or down if necessary. The attached mechanism will then provide the necessary up down motion required to operate the release mechanism. (B) Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (on ABB handle mechanism) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late. Step 7 Attach the door catch (item 11), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Use two screws (item 12) and lockwashers (item 13). The door catch prevents the door from being opened when the handle mechanism is in the ON position. Step 8 Drill and tap holes in panel per ABB instructions. See ABB instructions for locating extra holes for fuse clips. Step 9 Mount switch or circuit breaker using ABB instructions and parts. ABB connecting od assembly must be cut off per ABB instructions. 89115499 2018 Hoffman Enclosures Inc. PH 763 422 2211 nvent.com/hoffman - 5 -

For One- Through Six-Door Free-Standing Enclosures with Disconnect on Right Flange - 6-2018 Hoffman Enclosures Inc. PH 763 422 2211 nvent.com/hoffman 89115499

INTRODUCTION This installation instruction is for ABB Variable Depth, Small Handle, mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman two door, floor mounted Bulletin A21 enclosures with the disconnect on the centerpost. INSTALLATION STEPS Step 1 Install Mounting plate (item 1) and plate gasket (item 2) on the inside of the enclosure, behind the rectangular opening provided in the centerpost. Gasket side with PSA should be attached to the adapter plate.secure in place with four screws (item 3) and four nylon washers (otem 14). Step 2 Discard the ABB spring bracket which is normally installed inside the enclosure flange behind the ABB handle mechanism. Step 3 Assemble the ABB handle mechanism to the mounting plate which was installed in the enclosure in step 1. Omit cap screw and lockwasher which fits into bottom hole of operating handle. Step 4 Cut 2 1/2 off bottom end of slide arm (item 4). (bottom end has rectangular holes only) Step 5 Install the slide arm (item 4) over the defeater part of the handle assembly (on ABB handle mechanism) with notch toward door opening, as shown. Place the smaller diameter end of the shoulder collar (item 5) through the oval slot in the slide arm. Install long cap screw (item 6) with lockwasher (item 7) through shoulder collar into the bottom mounting hole of the ABB handle mechanism and tighten. The slide arm and defeater should move up and down smoothly. Install door hasp (ABB part) per ABB instructions. Step 6 Attach the bottom of the slide arm (item 4) to the offset arm of the lock release mechanism. Use two flat washers (item 8), two lockwashers (item 9), and two hex nuts (item 10). Do not tighten until parts are adjusted. Step 7 Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (on ABB handle mechanism) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late. Step 8 Attach the door catch (item 11), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Use two screws (item 12) and lockwashers (item 13). The door catch prevents the door from being opened when the handle mechanism is in the ON position. Step 9 Drill and tap holes in panel per ABB instructions. See ABB instructions for locating extra holes for fuse clips. Step 10 Mount switch or circuit breaker using ABB instructions and parts. ABB connecting rod assembly must be cut off per ABB instructions. * NOTE: Optional channel support kit is recommended when installing 600 AMP. circuit breakers in 72 1/8 high enclosures. 89115499 2018 Hoffman Enclosures Inc. PH 763 422 2211 nvent.com/hoffman - 7 -

For Floor-Mounted, Two-Door Enclosures with Disconnect on Centerpost - 8-2018 Hoffman Enclosures Inc. PH 763 422 2211 nvent.com/hoffman 89115499