Load disconnect switch Series 8146/5-V11

Similar documents
Safety Switches Series 8537

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plug and Socket Devices SolConeX 16 A Series 8570

Control switch/load disconnect switch Series 8008

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Control Buttons / Switches for Panel Mounting Series 8003

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8549

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Position Switches Series 8074/2

Terminal Boxes Series 8125

Position Switches Series 8060/2

Position Switches Series 8070/2

10 Load and Motor Switchgear

Terminal Boxes Series 8125

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Control Buttons Series 8082

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002

Floodlight LED Series 6125

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6402/2

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Ex UPS standard Series 8265

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Metal Position Switch Series 8074

Floodlight LED Series 6525

Compact Sheet-Steel Light Fittings Series 6114/1

Tubular Light Fitting with LED Series 6036

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Floodlight Series 6121

LED Linear Luminaire Series EXLUX 6402

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

11 Control Panels, Distribution Panels and Components

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Floodlight LED Series 6525

Compact Sheet-steel Emergency Light Fitting Series 6118/1

I Ex-safety switches I

Battery Boxes Series 8316

Portable Lamps Series HS6145, HSL145

I Ex-Safety switches I

Floodlight Series 6521/4

8150 Series Terminal Boxes

Control Device System NEC Series ConSig 8040

Sheet-Steel Light Fittings Series 6014 / 6414

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Operating Instructions

Linear fluorescent luminaire LED V-CG-S

Terminal Boxes Series 8252/1

Compact Sheet-Steel Light Fittings Series 6114

I Ex-safety switches I

HTSB system System overview

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

EX-D ENCLOSURES AND DISTRIBUTIONS

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Operating Instructions

M-0. M-0... series control, monitoring and signalling devices. Ex e

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

7 Lighting Technology

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

7 Lighting Technology

Tank Inspection Lights Series 6122

D509E. Manual Motor - Starters

INSTRUCTION MANUAL (ATEX / IECEx)

Internationally approved.

Sheet Steel Emergency Light Fitting Series 6018

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

7 Lighting Technology

BETA Switching Switches and Light Indicators

Operating Instructions

Ex m Solenoid Operator Type 0519

Terminal Boxes Series 8146

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Cable resistance thermometer Model TR40

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

INSTRUCTION MANUAL (ATEX / IECEx)

Terminal Boxes in Stainless Steel SLS**.T

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Linear Luminaire for Fluorescent Lamps

PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES

Transcription:

www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation of the main > Available for rated operating s of 16 A to 630 A > Robust enclosure made of glass fibre reinforced polyester > Large handle, lockable, or / red colours > Degree of protection IP66 00653E00 load and motor switches are used as main connection switches for distribution units and motor circuits. The standard range of switches have rated operating s up to 80 A. Switches for higher rated operating s are designed and manufactured to order. ATEX Class I (NEC 505) (NEC 506) Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 For use in x x x x For use in x *) For use in x *) *) Special version on request Explosion Protection Global (IECEx) Gas and dust 8146/5: IECEx PTB 06.0090 8146/5: Ex d e ia/ib [iaga] mb q IIA, IIB, IIC T6, T5, T4 Gb 8146/5: Ex tb IIIA, IIIB, IIIC T80 C, T95 C, T130 C Db Europe (ATEX) Gas and dust 8146/5: PTB 01 ATEX 1024 8146/5: E II 2 G Ex d e ia ib [ia Ga] mb q IIA, IIB, IIC T6, T5, T4 Gb 8146/5: E II 2 D Ex tb IIIA, IIIB, IIIC T80 C, T95 C, T130 C Db IP66 (marking on rating plate possible) Certifications and certificates Certificates IECEx, ATEX, Kazakhstan (TR), Russia (TR), Belarus (TR) WebCode 8146M Load disconnect switches and motor starters /1

Selection Table Version Enclosure material 10 A, 3-pole 10 A, 3-pole + N Equipment Colour Additional device Cable dia. range [mm] Order number Reversing switches are available only in V11, not as safety switches V37. Design 10 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 690 V AC Rated insulation 750 V Rated impulse 6 kv withstand Rated operational 10 A Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 U e I P 230 V ~ 400 V ~ 440 V ~ 10 A 10 A 10 A 2.2 kw 4.0 kw 4.0 kw 500 V ~ 10 A 5.5 kw 690 V ~ 10 A 7.5 kw Weight kg 8146/5-V11-300-00-0050 1,377 8146/5-V11-300-00-1050 1,377 8146/5-V11-400-00-0050 1,377 8146/5-V11-400-00-1050 1,377 DC-1 DC-13 (L/R = 300 ms) U e I U e I 220 V 6 A 3) 230 V 0.4 A 1 conducting path 110 V 6 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 6 A 24 V 10 A /2 Load disconnect switches and motor starters

Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary Rated operating Rated operational Switch Terminals Type 8146/5-V..- 40.000 operations 16 A, tripping characteristic: gg acc. to IEC/EN 60291-1 400 V AC 6 A 1 NO (ON delayed - OFF advanced) 2,5... 4 mm 2 finely stranded / solid wire No. of poles max. [A] Conductor cross-section [mm 2 ] Main Auxiliary min. max. Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE 0298-3. only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Temperature class / perm. ambient temperature 300-... 3 1 10 2,5 4 T6: -40... +51 C 300-00-... 3 0 T6: -40... +54 C T5: -40... +69 C 400-... 3 0 10 2,5 4 T6: -40... +51 C T6: -40... +54 C T5: -40... +69 C Load disconnect switches and motor starters /3

Selection Table Version Enclosure material 16 A, 3-pole 16 A, 3-pole + N Equipment Colour Additional device Cable dia. range [mm] with N-terminal 2 x 7... 17 Order number Reversing switches are available only in V11, not as safety switches V37. Design 16 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 690 V AC Rated insulation 690 V Rated impulse 6 kv withstand Rated operational 16 A Weight kg 8146/5-V11-302-00-0050 1,670 8146/5-V11-302-00-1050 1,670 8146/5-V11-102-00-0110 2,679 8146/5-V11-402-00-0050 1,730 8146/5-V11-402-00-1050 1,730 /4 Load disconnect switches and motor starters

Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 U e I P 230 V ~ 16 A 4.0 kw 400 V ~ 16 A 7.5 kw 440 V ~ 16 A 7.5 kw 500 V ~ 16 A 7.5 kw 690 V ~ 16 A 11.0 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary Rated operating Rated operational Switch Terminals Ambient conditions 16 A Type 8146/5-V..- DC-1, DC- DC-13 (L/R = 300 ms) 23 U e I U e I 220 V 16 A 3) 250 V 1.1 A 1 conducting path 120 V 16 A 125 V 2.2 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 16 A 60 V 5.0 A 40.000 operations 25 A, tripping characteristic: gg acc. to IEC/EN 60291-1 400 V AC 10 A 3-pole: 1 NO (ON delayed - OFF advanced) 6-pole: 2 NO (1 x ON delayed - OFF advanced / 1 x switching normally) 2.5... 10 mm 2 finely stranded / solid No. of poles max. [A] Conductor cross-section [mm 2 ] Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE 0298-3. only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Temperature class / Perm. ambient temperature Main Auxiliary min. max. 302-... 3 0 16 2.5 6 T6: -40... +51 C 102-.. 3 0 T6: -40... +54 C T5: -40... +69 C 402-... 4 0 16 2.5 6 T6: -40... +48 C T6: -40... +51 C T5: -40... +66 C Load disconnect switches and motor starters /5

Selection Table Version Enclosure material 20 A, 3-pole 20 A, 3-pole + N Equipment Colour Additional device Cable dia. range [mm] (M3, (M3, (M3, (M3, Order number Reversing switches are available only in V11, not as safety switches V37. Design 20 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 690 V AC Rated insulation 690 V Rated operational 20 A Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 U e I P 230 V ~ 20 A 5.5 kw 400 V ~ 20 A 7.5 kw 440 V ~ 20 A 11.0 W 500 V ~ 20 A 11.0 kw 690 V ~ 20 A 18.5 kw Weight kg 8146/5-V11-303-00-0010 1,795 8146/5-V11-303-00-1010 1,795 8146/5-V11-403-00-0010 1,815 8146/5-V11-403-00-1010 1,815 Service life of electrical / mechanical parts DC-1, DC- DC-13 (L/R = 300 ms) 23 U e I U e I 220 V 20 A 3) 250 V 1.1 A 1 conducting path 120 V 20 A 125 V 2.2 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 20 A 60 V 5.0 A 40.000 operations /6 Load disconnect switches and motor starters

Max. short-circuit protection Auxiliary Rated operating Rated operational Terminals Ambient conditions 20 A Type 8146/5-V..- 35 A, tripping characteristic: gg acc. to IEC/EN 60291-1 500 V AC 10 A 4... 6 mm 2 finely stranded / solid No. of poles max. [A] Conductor cross-section [mm 2 ] Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE 0298-3. only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Temperature class / Perm. ambient temperature Main Auxiliary min. max. 303-... 3 0 20 4 6 T6: -40... +40 C T5: -40... +55 C 403-... 4 0 20 4 6 T5: -40... +51 C Load disconnect switches and motor starters /7

Selection Table Version Enclosure material 25 A, 3-pole 25 A, 3-pole + N 25 A, 6-pole Equipment Colour Additional device Cable dia. range [mm] (M3, (M3, with N-terminal 2 x 9... 21 (M3, (M3, (M3, 4 x 7... 17 1 x4... 13 4 x 7... 17 1 x4... 13 Order number Reversing switches are available only in V11, not as safety switches V37. Design 25 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 690 V AC Rated insulation 690 V Rated operational 25 A Weight kg 8146/5-V11-304-00-0010 1,975 8146/5-V11-304-00-1010 1,975 8146/5-V11-104-00-0110 2,621 8146/5-V11-404-00-0010 2,108 8146/5-V11-404-00-1010 2,108 8146/5-V11-604-60-0010 2,839 8146/5-V11-604-60-1010 2,839 /8 Load disconnect switches and motor starters

Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 AC-23 U e I P I P 230 V ~ 25 A 5.5 kw 400 V ~ 25 A 11.0 kw 440 V ~ 25 A 11.0 kw 500 V ~ 690 25 A 15.0 kw V ~ 25 A 22.0 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary Rated operating Rated operational Terminals Ambient conditions 25 A Type 8146/5-V..- 40.000 operations 35 A, tripping characteristic: gg acc. to IEC/EN 60291-1 500 V AC 10 A 4... 6 mm 2 finely stranded / solid No. of poles max. [A] Conductor cross-section [mm 2 ] Main DC-1, DC- DC-13 (L/R = 300 ms) 23 U e I U e I 220 V 25 A 3) 250 V 1.1 A 1 conducting path 120 V 25 A 125 V 2.2 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 25 A 60 V 5.0 A Auxiliary Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE 0298-3. only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate min. max. Temperature class / Perm. ambient temperature 304-... 3 0 25 4 6 T6: -40... +40 C 104-... 3 0 T5: -40... +55 C 404-... 4 0 25 4 6 T5: -40... +51 C 4 0 25 6 6 T6: -40... +44 C T5: -40... +52 C T5: -40... +59 C 604-... 6 2 22.5 4 6 T6: -40... +41 C T5: -40... +56 C 6 2 25 4 6 T5: -40... +49 C 6 2 25 6 6 T6: -40... +42 C T5: -40... +50 C T5: -40... +57 C 6 0 20 4 6 T6: -40... +46 C T5: -40... +61 C T5: -40... +52 C 6 0 22.5 4 6 T5: -40... +53 C T5: -40... +48 C 6 0 25 4 6 T5: -40... +45 C 6 0 25 6 6 T5: -40... +52 C T5: -40... +48 C Load disconnect switches and motor starters /9

Selection Table Version Enclosure material 40 A, 3-pole 40 A, 3-pole + N 40 A, 6-pole Equipment Colour Additional device Cable dia. range [mm] 2 x 12... 28 (M40), 1 x 4... 13 2 x 12... 28 (M40), 1 x 4... 13 2 x 12... 28 (M40), 1 x 4... 13 2 x 12... 28 (M40), 1 x 4... 13 4 x 12... 28 (M40), 1 x 4... 13 4 x 12... 28 (M40), 1 x 4... 13 Order number Reversing switches are available only in V11, not as safety switches V37. Design 40 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 690 V AC Rated insulation 750 V Rated operational 40 A Weight kg 8146/5-V11-305-00-0010-K 5,210 8146/5-V11-305-00-1010-K 5,210 8146/5-V11-405-00-0010-K 7,214 8146/5-V11-405-00-1010-K 7,214 8146/5-V11-605-00-0010-K 9,000 8146/5-V11-605-00-1010-K 9,000 /10 Load disconnect switches and motor starters

Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 U e I P 240 V ~ 40 A 11.0 kw 400 V ~ 40 A 22.0 kw 440 V ~ 40 A 22.0 kw 500 V ~ 40 A 22.0 kw 690 V ~ 40 A 37.0 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary Rated operating Rated operational Terminals Ambient conditions 40 A Type 8146/5-V..- 40.000 operations 80 A, tripping characteristic: gg acc. to IEC/EN 60291-1 500 V AC 6 A 1.5... 2.5 mm 2 finely stranded / solid No. of poles max. [A] Conductor cross-section [mm 2 ] Main DC-23, DC- 1 U e I 220 V 40 A 3) 1 conducting path 120 V 40 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 40 A Auxiliary Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE 0298-3. only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate min. max. Temperature class / Perm. ambient temperature 305-...-K 3 0 40 10 25 T6: -40... +48 C T6: -40... +51 C T5: -40... +66 C 405-...-K 4 0 40 10 25 T6: -40... +45 C T6: -40... +48 C T5: -40... +63 C 605-...-K 6 0 40 10 25 T6: -40... +47 C T5: -40... +51 C T5: -40... +62 C Load disconnect switches and motor starters /11

Selection Table Version 63 / 80 A, 3-pole 63 / 80 A, 3-pole + N 63 / 80 A, 6-pole Enclosure material Equipment Colour Additional device Cable dia. range [mm] 2 x 16... 35 (M50), 2 x 16... 35 (M50), 2 x 16... 35 (M50), 2 x 16... 35 (M50), 4 x 16... 35 (M50), 4 x 16... 35 (M50), Order number Reversing switches are available only in V11, not as safety switches V37. Weight kg 8146/5-V11-306-00-0010-K 5,315 8146/5-V11-306-00-1010-K 5,315 8146/5-V11-406-00-0010-K 7,860 8146/5-V11-406-00-1010-K 7,860 8146/5-V11-606-00-0010 12,473 8146/5-V11-606-00-1010 12,473 Design 63 / 80 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 500 V AC (80 A) / 690 V AC (63 A) Rated insulation 750 V Rated operational 63 / 80 A Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 AC-3 U e I P I P 230 V ~ 400 V ~ 440 V ~ 500 V ~ 690 V ~ 63 A 63 A 63 A 63 A 63 A 18.5 kw 30.0 kw 37.0 kw 37.0 kw 55.0 kw 80 A 80 A 80 A 80 A 22.0 kw 45.0 kw 45.0 kw 55.0 kw DC-23, DC- 1 U e I 220 V 80 A 3) 1 conducting path 120 V 80 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 80 A /12 Load disconnect switches and motor starters

Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary Rated operating Rated operational Terminals Ambient conditions 63 / 80 A Type 8146/5-V..- 40.000 operations 63 A: 125 A, 80 A: 160 A, tripping characteristic: gg according to IEC/EN 60291-1 500 V AC 6 A 1.5... 2.5 mm 2 finely stranded / solid No. of poles max. [A] Conductor cross-section [mm 2 ] Main Auxiliary Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE 0298-3. only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate min. max. Temperature class / Perm. ambient temperature 306-...-K 3 0 50 10 25 T6: -40... +43 C 3 0 63 16 25 T6: -40... +42 C T5: -40... +57 C 3 0 80 25 25 T6: -40... +40 C T5: -40... +44 C T5: -40... +55 C 406-...-K 4 0 63 35 50 T6: -40... +55 C T5: -40... +70 C 4 0 63 50 50 T6: -40... +57 C T5: -40... +72 C 4 0 80 35 50 T6: -40... +45 C T5: -40... +50 C T5: -40... +60 C 4 0 80 50 50 T6: -40... +50 C T5: -40... +54 C T5: -40... +65 C 606-... 6 0 50 10 50 T6: -40... +41 C T5: -40... +56 C 6 0 63 16 50 T6: -40... +41 C T5: -40... +56 C 6 0 63 25 50 T6: -40... +47 C T5: -40... +62 C 6 0 80 25 50 T5: -40... +51 C 6 0 80 35 50 T6: -40... +43 C T5: -40... +58 C We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Load disconnect switches and motor starters /13

Dimensional drawings (all dimensions in mm) - subject to alterations B C A Circuit diagrams 04120E00 Dimensions [mm] A B C 112.5 112.5 131 112.5 112.5 131 170 112.5 132 170 112.5 132 170 170 172 170 170 132 170 170 132 3-pole 10 A 8146/5-V11-300-00-... 8146/5-V11-400-..-... 16 A 8146/5-V11-302-..-... 8146/5-V11-402-..-... 8146/5-V11-102-..-... 20 A 8146/5-V11-303-..-... 8146/5-V11-403-..-... 25 A 8146/5-V11-304-..-... 170 170 8146/5-V11-104-..-... 227 170 8146/5-V11-404-..-... 170 170 40 A 8146/5-V11-305-...-K 340.5 170 8146/5-V11-405-..-..-...-K 340.5 340.5 63 / 80 A 8146/5-V11-306-...-K 340.5 170 8146/5-V11-406-..-...-K 340.5 340.5 6-pole 25 A 8146/5-V11-604-..-... 227 170 172 40 A 8146/5-V11-605-...-K 340.5 340.5 205 63 / 80 A 8146/5-V11-606-... 681.5 340.5 205 132 171 132 176.5 195 195 195 0 90 1 3 5 7 9 01 13 23 0 90 1 3 5 2 4 6 8 10 02 14 24 15622E00 2 4 6 15581E00 -V..-6..-60-.. 6-pole + 1 NO (1x ON delayed - OFF leading / 1 x switching normally) -V..-3..-00-.. 3-pole 90 120 180 1 3 5 7 0 90 N 1 3 5 2 4 6 8 01846E00 N 2 4 6 15582E00 -V11-4..-00 3-pole + N -V11-400-00 3-pole + N 0 90 1 ( 3) 5 7 (9) 0 90 1 3 5 7 9 01 2 4 6 (8) (10) 12196E00 2 4 6 8 10 02 15579E00 -V11-102 -V11-104 3-pole reversing switch -V..-6..-00-.. 6-pole /14 Load disconnect switches and motor starters

Accessories and Spare Parts Designation Figure Description Art. no. Weight Auxiliary contact 2 NC (8080/1-3) 168356 0.026 1 NC contact + 1 NO contact (8080/1-168351 0.026 kg 12446E00 2 NO (8080/1-4) 168353 0.026 The switching function of the auxiliary contact depends on the installation slot used. Left: delayed (ON), leading (OFF); Right: synchronising Left and right: synchronising Note: The auxiliary can only be retrofitted for 40 A and 63/80 A versions. For all other versions, the auxiliary contact must be ordered separately when placing the order. Retrofitting is not possible for this. Auxiliary contact key for removing the mounted auxiliary contact 201909 0.035 14151E00 Load disconnect switches and motor starters /15