Stainless Steel Combination Drench Shower and Eyewash Table of Contents Pre- Information.... Instructions... Assembly of Components....4 Parts List....5 15-5SS Rev. U; ECN 1-05-0 01 Bradley Page 1 of 5 P.O. Box 09, Menomonee Falls, WI USA 505-009 PHONE 800.BRADLEY (800.7.59) FAX 6.51.5817 bradleycorp.com
R 114-051 Datum Signe P.O. BOX 09, MENOMONEE FALLS, WI 505-009 USA TEL: 1-800-BRADLEY FAX: (6-51-5817) http://www.bradleycorp.com IMPORTANT THIS SIDE UP Packing List Read this installation manual completely to ensure proper installation, then file it with the owner or maintenance department. Compliance and conformity to drain requirements and other local codes and ordinances is the responsibility of the installer. Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. Flush the water supply lines before beginning installation and after installation is complete. Test the unit for leaks and adequate water flow. Main water supply to the eyewash should be ON at all times. Provisions shall be made to prevent unauthorized shutoff. P.O. Box 09, Menomonee Falls, WI 5051 TEST THIS UNIT EACH WEEK DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden. Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement. Signed Signed Unterschrift Signed Signed The ANSI Z58.1 standard requires an uninterrupted supply of flushing fluid. Bradley plumbed emergency fixtures require a minimum of 0 PSI (0.1 MPa) flowing pressure. Flushing fluid should be tepid per ANSI Z58.1. The inspection and testing results of this equipment should be recorded weekly to verify proper operation. This equipment should be inspected annually to ensure compliance with ANSI Z58.1. Workers who may come in contact with potentially hazardous materials should be trained regarding the placement and proper operation of emergency equipment per ANSI Z58.1. For questions regarding the operation or installation of this product, visit www.bradleycorp. com or call 1-800-BRADLEY. Product warranties and service parts information may also be found under Products on our web site at www.bradleycorp.com. /19/01 Bradley 15-5SS Rev. U; ECN 1-05-0
Supplies Required: () ³ ₈" floor anchors and bolts Pipe sealant Piping to 1¼" NPT water supply inlet and 1¼" NPT drain outlet on unit Adequate supply pipe supports Minimum 4" (10mm) drain to accommodate 0 gallons (115 liters) per minute discharge for shower waste OPTIONAL: sign-mounting hardware Local codes may require the installation of a backflow prevention valve to complete proper installation. Compliance with local codes is the responsibility of the installer. Valve must be tested annually to verify that it is functioning properly. Backflow prevention valves are not included with the fixture and may be supplied by the contractor or purchased from Bradley Corporation. Step 1: Secure base to floor 1. Install three suitable anchors (supplied by installer) for ³ ₈" bolts in the floor.. Bolt the base to the floor anchors using ³ ₈" bolts (supplied by installer). Step : Assemble components 1. Assemble the remaining unit components as shown on page 4. Apply pipe sealant (by installer) to all male-threaded pipe joints. Use the rubber grip pad provided or a strap wrench around pipes when tightening to prevent marring. Place the grip pad on the pipe, then put the wrench over the grip pad and turn the pipe with the wrench. When connecting the steel chain, first connect the chain to the S hook on the foot treadle. Then, with the foot treadle raised up, straighten the chain and connect a link to the S hook on the valve handle. Make sure the chain is pulled tight and opens valve completely. The length of chain will vary from unit to unit. Notice: Once the chain length is determined and confirmed to operate the valve correctly, use a pliers to close all s-hook openings to maintain this setting. The bottom edge of the showerhead should be 86¾" (0mm) from the floor. Step : Connect water supply IMPORTANT! Do not rely on Bradley s Combination Unit to support supply piping. 1. Connect water supply piping to 1¼" NPT inlet on unit (piping by installer). Provide adequate supports (by installer) for supply pipe using pipe hangers or other means.. Connect drain piping to 1¼" NPT drain outlet on unit (piping by installer).. Hang the safety sign from the unit with the curtain hooks provided (or mount it to the wall using sign-mounting hardware by installer). ¾" (95mm) 86¾" (0mm) 66 7 8" (1699mm) 6⁵ ₈" (670mm) Ø 1½ (8mm) 4¼" (107mm) 6¾" (9mm) to Bottom of Base Top View From Bowl Ø 10¾" (7mm) 9" (9mm) 10¼" (60mm) 9" (9mm) 65½" (1664mm) 94" (88mm) 6" (15mm) Ø 9" (9mm) Flange with () Ø ³ ₈" (10mm) Holes on Ø 8" (0mm) Bolt Circle All dimensions assume standard thread engagement. Variations in manufacturing allow for +/- 1 8" (mm) per threaded joint. To find the tolerance of a dimension, add the number of thread joints in between a dimension and multiply it by 1 8" (mm). Bradley 15-5SS Rev. U; ECN 1-05-0 /19/01
P.O. BOX 09, MENOMONEE FALLS, WI 505-009 USA TEL: 1-800-BRADLEY FAX: (6-51-5817) http://www.bradleycorp.com 114-05 Assembly of Components 6 7 8 9 Optional 1¼" NPT Supply Inlet (best for rigid support) If tee (Item ) is used as a supply inlet, use plug (Item 6) on tee (Item ) 1¼" NPT Supply Inlet 1 1 11 9.1 10 7 9. 9.11 14 5.5 5.4 5. 5.10 5.9 5.8 5.7 5.1 5.6 4 Flow control this end 5. 0 17 19 4 5 0 5 15 18 16 16 17 1 8 0.1 6.6 6. Items 9.1 9. come preassembled as Item 9. 6. 6. 6.5 6.1 1 1¼" NPT Drain Outlet 6.4 4 /19/01 Bradley 15-5SS Rev. U; ECN 1-05-0
Parts List Item Part No. Qty. Description 1 11-079 1 Base 69-198 5 Pipe Tee 1¼" 11-999 Pipe 1¼" x ½" 4 S06-5 1 Pipe, Solid 1¼" 5 11-1195 1 Pipe 1¼" x 6" 6 69-140 1 Pipe Plug 1¼" 7 69-1400 1 Reducing Bushing 1¼" x 1" 8 11-995 1 Pipe 1" x 9" 9 S0-081 1 1" Ball Valve Assembly 9.1 S7-76 1 1" Ball Valve with Nut 9.11 160-15 1 Hex Nut 7 16"-0 UNF 9. 18-155 1 Handle 10 151-001 Curtain Hook 11 11-996 1 Pipe 1" x 1" 1 169-1075 1 Elbow 1" 1 S4-01 1 Showerhead Assembly 14 18-157 1 Pull Rod 15 69-1401 1 Reducing Bushing 1¼" x ½" 16 11-100 Pipe ½" x ½" 17 69-196 Street Elbow 1/" 18 69-197 1 Pipe Union 19 11-998 1 Pipe 1¼" x 6½" 0 S7-8 1 ½" Ball Valve with Nut 0.1 110-48 1 Nut 16 Stainless Steel 1 S08-98 1 Flag Handle 11-1001 1 Pipe ½" x 4" NOTES: 1. All pipe/fittings are NPT.. Items are 16SST unless noted in their descriptions [ ]. Item Part No. Qty. Description 69-195 1 Pipe Elbow 1¼" 4 11-997 1 Pipe 1¼" x " 5 S90-87 1 Eyewash Assembly 5.1 111-078 1 Inlet Drain 5. 14-08 1 Gasket [Buna N ] 5. 187-4 1 Bowl 5.4 17-07 1 Cup Strainer 5.5 S1-075 1 Stem 5.6 11-1159 1 Spacer 5.7 S05-156 1 Yoke 5.8 115-156 Sprayhead 5.9 15-449 1 Plug 5.10 107-71 Dust Cover [Plastic] 6 S45-114SS16 1 Stainless Steel 16 Foot Treadle Kit 6.1 181-014A 1 Stainless Steel 16 Foot Pedal 6. 69-199 S Hook 6. 14-009A 1 Chain " length [04L SST] 6.4 160-401 1 Screw 8"-16 x -/4" 6.5 161-164 1 Nut, 8"-16 Stainless Steel Centerlock 6.6 18-166 1 Handle 7 114-05 1 Safety Sign [Plastic] 8 14-00DA 1 Lockwasher 9 69-915 1 Grip Pad (not shown) 0 15-7R16 1 Adapter Prepack S0-111 includes items 0, 1, 8, 0 For proper handle and ball valve kits, refer to instruction sheet 15-1774. Bradley 15-5SS Rev. U; ECN 1-05-0 /19/01 5