TTH-1315 TTH-1315-A Temperature & Humidity Sensor User s Manual

Similar documents
TR-4 Tipping Bucket Rain Gauge User s Manual

WSC-5-DDOR Wind Speed Controller Dual Set Point User s Manual

COMPLETE WEATHER STATION USER S MANUAL

Model 8141-A 8141-B 8141-D. Self-Aspirated Radiation Shield. User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC.

TEMPERATURE - HUMIDITY VAISALA HMP155

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

C3000 SIGNAL TRANSMITTER. Introduction

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

SOIL RESISTIVITY TESTER

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

IAQ-CALC TM Indoor Air Quality Meter

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

Long-Range Barrier Sensors

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

Defender 3000 Series Base Instruction Manual

Spy pocket Jeepmeter ope rati ng instructions

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

SETRA Operating Instructions Series DPT 230 Pressure Transducers

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Infrared Thermocouple Probe

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

Traffic Logix SafePace 450 Radar Speed Sign

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

INSTRUCTION MANUAL SURFACE RESISTIVITY METER SRM-110

BMRX Series ROTARY LEVEL CONTROL

i400s Calibration Information Introduction

IAQ-CALC TM Indoor Air Quality Meter

OPERATING INSTRUCTIONS. TempCheck Non-Contact Infrared Thermometer IRT200 F C + -

Model 1693, 1694 Switching DC Power Supply

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

Indoor Air Quality Meter

The Most Efficient Means to Charge Batteries and Power Loads using Diesel Fully Automatic Battery Charging Options Features

HIGH VOLTAGE PROVING UNIT

Model Mast Adapter with 4-Foot Boom. User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC. COM

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

BEAMER Tilt Beam Sensor

ZT-1 Tonnage Load Module By Toledo Integrated Systems User s Manual

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

SERIES 1000 ELECTRIC ACTUATORS

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual

Phase Sequence Tester

Washdo. wn Scale Base

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Hydro-Park High-end Four Post Parking Lift PROFESSIONAL PARKING SOLUTION PROVIDER!

BATHROOM ACCESSORIES

8220I-3CA1 10 kw Diesel DC Generator

TC26-B Vehicle Sensor

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual

Rain Gauge Smart Sensor (Part # RGA-M0XX, RGB-M0XX)

SSI Technologies MediaSensor

SERIES L1B & L1D LADDERS

Users Manual. MegOhmMeter

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

Video & Power Over Coax Kit

Installation Manual for the SHURflo LCB - G Pump Controller

Temperature Calibrator

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

INSTRUCTION MANUAL S O L A R L E D U M B R E L L A L I G H T

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610


MMV Digital Length Measuring Gauge INSTRUCTION MANUAL

Low Pressure Sensor. Overview. Specifications. Installation and Operation

DT304. Digital Temperature Logger INSTRUCTION MANUAL

Oil Pressure Display Gauges Part numbers: Analog Oil/Fuel SAE Pressure Gauge psi Analog Oil SAE Pressure Gauge.

WEB CONTROL PRODUCTS

Tachometer. English. Users Manual

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Document No D1 Revised December Atlantic Ultraviolet Corporation

6-PACK SOLAR PATHWAY LIGHTS

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Silicon Cell Pyranometer Model User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC. COM

User s Manual. Item no. 2561

ANALOG INSULATION RESISTANCE TESTER

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Panel Mount Digital Tachometer Model

SSR SSR SSR SSR

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

2015 & 2018 Fender Brace Installation Instructions

Speed Sensors Line Guide

DC REGULATED POWER SUPPLY

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

TS Temperature Sensor and Transducers. Product Bulletin. Wide range of mounting types and signal outputs

Installation Instructions. Application List Dodge 24V PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION

P/N# Performance Lowering Springs Installation Instructions

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

HA/HAB Fiberglass Wall Mount Ventilators

650mA Phase Dimmable LED Driver

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

Transcription:

Relied on Worldwide in the Most Extreme Conditions TTH-1315 TTH-1315-A Temperature & Humidity Sensor User s Manual Texas Electronics, Inc. Dallas, TX 75237 Fax.214.631.4218 4230 Shilling Way Tel.214-631-2490 www.texaselectronics.com

DESCRIPTION Model TTH-1315 Temperature Humidity Sensor The Texas Electronics, Inc. Model TTH-1315 Sensor utilizes a Vaisala HMP60 Humidity Temperature Probe with interchangeable sensing elements that do not require calibration. The unit is encased in a corrosion-resistant aluminum radiation shield that allows for wind aspiration and protection from the sun s UV rays. The shield is finished in white powder-coat to provide for virtual cosmetic invisibility while reflecting much of the radiant heat from surrounding objects and the sun. Overcurrent protection is provided in a NEMA 4X enclosure that is mounted to the angled mounting bracket on the sensor. Tranzorbs are utilized to protect the sensor and signal conditioning units in an overcurrent situation. With DC voltage applied to the sensor, the unit will return signal voltages that are linear to the range of the instrument. Signal conditioning is applied to ensure proper voltages are returned and can be amplified or modified to a current output to connect to any analog signal processing unit. Specifications TTH-1315 TTH-1315-A Sensor: Viasala INTERCAP HMP60 Viasala INTERCAP HMP60 Sensor Protection: Stainless steel sintered filter Stainless steel sintered filter Accuracy: Measuring Range: +/- 0 to 1 100% within Relative the range Humidity of +/- 0 to 1 100% within Relative the range Humidity of 40 to +140 F (-40 to +60 C) 40 to +140 F (-40 to +60 C) Analog Output 34.4 to Signals: +43.3 C) 0 to 1 V (-34.4 to +43.3 C) 4-20 ma -40 to +140 F (-40 to +60 C) -40 to +140 F (-40 to +60 C) Analog Signal Resolution: 0.02% RH & 0.1 F 0.02% RH & 0.1 F Operating Limits: Same as measuring range Same as measuring range Accuracy: +/- 1.5% RH and +/- 0.5 F / 0.3 C +/- 1.5% RH and +/- 0.5 F / 0.3 C Repeatability: Better than 0.5% RH and 0.1 C / 32.18 F Better than 0.5% RH and 0.1 C / 32.18 F Protection Grade: (+43.3 to +48.8 C) IP65 (+43.3 to +48.8 C) IP65 Supply Voltage: 5 to 28 VDC 5 to 28 VDC Current Consumption: 1 ma average, max. peak 5 ma 1 ma average, max. peak 5 ma Minimum Excitation Time: 4s 4s EMC Compatibility (CE): EN 61326-1 EN 61326-1 Material: Powder-coat, White Aluminum Powder-coat, White Aluminum Dimensions: 12 Height 12 Height Diameter: 7¼ 7¼ Warranty: 3 years 3 years

FEATURES & BENEFITS Combines temperature and humidity in one sensing unit Vaisala HMP60 has interchangeable sensing elements requiring no calibration Stacked plate construction of shelter provides natural ventilation Quick-release mounting bracket allows for easy installation and maintenance Aluminum radiation shield is lightweight and extremely durable White powder-coat finish reflects most radiant heat from sun and surrounding objects INSTALLATION & MAINTENANCE The radiation shield with sensing element can be pole or mast mounted. Whenever possible, sensors should be installed at a height of 4 ft. (1.2 meters) or greater over earth or sod at least 100 ft. (30.48 meters) away from any concrete or other hard-surfaced area and not closer to any other object than four times the height of the object above the instrument shelter or remote sensors. Avoid roof installations if possible. If it is necessary to roof-mount shelters and sensors, they should not be closer than 30 ft. (9.14 meters) to any large, vertical reflecting surface (walls, etc.), exhaust fans, or cooling towers. Electronic remote sensors, when roof-mounted, should be installed at least 9 ft. (2.74 meters) or greater above the roof surface. To minimize radiation effects from the roof, they can also be mounted on a horizontal boom so they extend from the side of the building roof or tower assembly. ORDERING INFORMATION Model # TTH-1315 TTH-1315-A Description Temperature & Humidity Sensor Temperature & Humidity Sensor, 4-20 ma Optional Parts / Accessories Radiation Shield Assembly Vaisala HMP60 Humidity & Temperature Probe

Warranty Texas Electronics, Inc. (hereafter TEI) warrants the equipment manufactured by it to be free from defects in material and workmanship. Upon return, transportation charges prepaid to TEI, within three (3) years of original shipment of sensors and one (1) year of original shipment of electronics, recorders and indicators, TEI will repair or replace, at its option, any equipment which it determines to contain defective material or workmanship, and will return said equipment to purchaser, F.O.B., TEI. Texas Electronics shall not be obligated however to repair or replace equipment which has been repaired by others, abused, improperly installed, altered or otherwise misused or damaged in any way. TEI will not be responsible for any dismantling, re-assembly, or reinstallation charges. This warranty is in lieu of all other warranties, expressed or implied. TEI shall not be liable for any special, indirect, incidental or consequential damages claimed in connection with any rescission of this agreement by purchaser.