Fused Coordination Panelboard

Similar documents
Fused Coordination Panelboard

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Now - Up To 400A Mains!

Specification made simple for selective coordination in a compact size

Quik-Spec Coordination Panelboard Specifications

Selection and application guide

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Bussmann series Quik-Spec Coordination Panelboard

SECTION PANELBOARDS

Quik-Spec Coordination Panelboard

Assembly not available for new installations.

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

Quik-Spec Electrical Gear

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Quik-Spec. Section Contents

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Pow-R-Line 3E Panelboard

A. Submit manufacturer's literature and technical data before starting work.

WARREN COUNTY, N.Y. M/E REFERENCE

Quik-Spec Coordination Panelboard A fusible panelboards

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Selective Coordination Requirements

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Quik-Spec Coordination Panelboard A fusible panelboards

Service Entrance Methods

Low Voltage Fuses For Motor Protection

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Electrical Safety and Overcurrent Protection

Selective Coordination Enforcement:

Compact Circuit Protector (CCP)

Learning Module 10: Loadcenters. 101 Basic Series

UL248 North American Low Voltage Fuses

General Purpose US Fuses

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Compact Circuit Protector (CCP)

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

ECET Distribution System Protection. Overcurrent Protection

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

Effective December 2015 Supersedes September 2013

ACW Molded-Case Circuit Breaker UL 489 Listed

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

OTEC Transfer switch open transition

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

Quik-Spec Coordination Panelboard

QMB Fusible Panelboards

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Quick Start Guide TS 910 & TS 920

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Compact Circuit Protector (CCP)

SECTION MOTOR CONTROL

Optimizing Emergency Power Systems for Health Care Applications

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

UL/CSA Listed Power Fuses P F THE MOST POPULAR UL/CSA LISTED POWER FUSES TO MEET THE MOST POPULAR PROTECTION PRIORITIES

ASCO Low Voltage Automatic Transfer Switch Systems

CUBEFuse. CUBEFuse catalog numbers (amps)

Low Voltage Automatic Transfer Switch Systems

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

SECTION DISTRIBUTION AND GROUNDING

Transfer switch OTEC and OTECSE open transition

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Design Standards NEMA

Compact Circuit Protector (CCP)

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

Selecting Protective Devices

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

Solar Combiner Solutions

BAC Custom Engineered Controls

Quick Start Guide TS 910

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

SECTION WIRING DEVICES

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Transfer switch OTEC open or delayed transition

Applying Interrupting Rating: Circuit Breakers

Slim is in. Hospital Grade SmartlockPro Slim GFCI Receptacles. Specification and Ordering Guide

Evaluating Selective Coordination Between Current-Limiting Fuses And Non Current-Limiting Circuit Breakers

Applying Interrupting Rating: Circuit Breakers

Electrical safety and reliability: Selective coordination. Protect with selective coordination

Self-protected Combination Starters System PKZ 2-SP

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

Devices for Branch Circuits and Feeders

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

SWITCHGEAR DIVISION PRODUCT PROFILES

IN2 Enclosed Switches and Circuit Breakers

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary.

University of Houston Master Construction Specifications Insert Project Name

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

PRE-ENGINEERED SOLUTIONS. LCP Series Fused Coordination Panel LPS Series Shunt Trip Disconnect Switch

Laser Service Factory-assembled Panelboards

Selection Guide Motor Control Device Solutions

Transcription:

Fused Coordination Panelboard SOLUTIONS GUIDE SOLUTIONS GUIDE Branch Circuit Protection

Introducing Mersen s Fused Coordination Panelboard Selective Coordination is required in several locations as defined in the National Electrical Code (NEC). Mersen s Fused Coordination Panelboard (MFCP) can simplify the process in achieving code compliance for designers. These panels are provided with a default short circuit current rating (SCCR) of 200kA and provide overcurrent protection through a combination of a circuit breaker and a fuse. The circuit breaker is designed to operate on overloads up to 2 times their rating and the fuse over 2 times up to 200kA. Feature UL 67 Listed panelboard with a default short-circuit current rating of 200kA Combination rated circuit breaker and fuse for branch circuit protection Class CC and Class J fuses for Branch short-circuit protection Maximum of 3 fuse sizes Selective Coordination between upstream and branch fuses when ratios are maintained FingerSafe fuseholders Interlocked branch circuit fuseholder and circuit breaker Standard 20 inch wide panel Surface & flush mount 20, 32, 42 branch circuits NEMA 1, 12 and 3R Feed-Through lugs Surge Protection MLO, Main Switch (with or without fuses) Service entrance rated Visible blades on main disconnect without removing covers Cover interlocked with main disconnect UL listed up to 600VAC Main lug only, non-fused main disconnect or fused main disconnect up to 400A Optional open fuse indication Optional integral surge protection Benefit Easily comply with NEC 110.10 as most systems will be below 200kA Fuses will open only on short-circuits Circuit Breaker can easily be reset on common overloads Standard fuse classes that are commonly stocked by distributors Typically already in inventory Simple selective coordination without short-circuit current study Meets requirements of NEC No exposed live components for increased safety Ensures that the fuse is disconnected on both line/load before removal Meets existing space requirements of other commercial available panelboards Increased flexible options to meet specific application requirements Visual verification of disconnect operation Ensures that power is disconnected before cover can be removed Meets most common North American voltages Provides designers with options Easy identification of open branch fuses Easily provide surge protection for critical branch circuits

Branch Circuit Protection Overloads are the most common over current condition and MFCP s innovative combination branch circuit protection provides resettable overload protection up to 2 times the circuit rating while still providing true class CC and J protection for your critical loads on high current faults. The kits below provide everything needed for expansion of an existing panel. Circuit Breaker provides resettable overload protection for low level faults. Includes ratings from 15A to 100A in 1,2 or 3 pole options Mechanically Interlocked to ensure the fuseholder is not opened while power is on Only 3 fuse ratings are required to provide short-circuit protection. Insulated Bus bar makes the connection between the circuit breaker and fuseholder Part number Poles Current rating Fuse (included) MFCP-K-15-1 1 MFCP-K-15-2 2 15A MFCP-K-15-3 3 MFCP-K-20-1 1 MFCP-K-20-2 2 20A MFCP-K-20-3 3 ATDR30 MFCP-K-25-1 1 MFCP-K-25-2 2 25A MFCP-K-25-3 3 MFCP-K-30-1 1 MFCP-K-30-2 2 30A MFCP-K-30-3 3 Part number Poles Current rating Fuse (included) MFCP-K-35-1 1 MFCP-K-35-2 2 35A MFCP-K-35-3 3 MFCP-K-40-1 1 MFCP-K-40-2 2 40A MFCP-K-40-3 3 AJT60 MFCP-K-50-1 1 MFCP-K-50-2 2 50A MFCP-K-50-3 3 MFCP-K-60-1 1 MFCP-K-60-2 2 60A MFCP-K-60-3 3 Please contact the factory for 100A branch circuits.

Branch Circuit Kit Highlights Easy selectivity ratios with upstream fuses Voltage: 120/208, 120/240, 277/480, 347/600 Main Bus: 250A or 400A, MLO, Fused Main or Non-fuse Main disconnect SCCR: 200kA Surge Protection (SPD) optional 20, 32 or 42 branch circuits Standard 20" wide Feed through lugs optional Surface mount Uses commonly available class CC & J fuses Dimensions (NEMA 1 Enclosures) For standard panels: Width = 20 inches Depth = 6 inches Height varies depending on number of circuits and main options (see table below). Number of Circuits Height (inches) 250A-Bus 400A-Bus 20-circuit 44 56 32-circuit 62 74 42-circuit 86 86 Main Up to 400A Fused Main Disconnect Allows for panel isolation Lockout provision Visible contacts Interlocked with cover NEMA 1 Enclosure Specifications Tub: Galvanized unpainted steel. One endwall is provided with knockouts, and the other endwall is blank. Door: Equipped directory card, flush mount lock Trim and Door Finish: ANSI 49 grey baked enamel electrodeposited over cleaned, phosphatized steel AJT Amp-Trap 2000 fuses Main Fuse Time Delay 2:1 coordination ratio 600VAC interrupting rating 200kA Example Drawings: Branch Circuits Circuit breaker opens overloads up to 2 times circuit rating ATDR, AJT fuses open short circuit currents Fuseholder interlocked to prevent opening while energized. Circuits up through 100A 1, 2 & 3 pole. True Class J and CC protection.

selective coordination with Mersen s fcp Achieving selective coordination typically requires a costly short circuit current study. However with the Mersen Fused Coordination Panelboard, coordination can easily be determined with upstream Mersen fuses. MFCP utilizes Amp-Trap 2000 ATDR and AJT fuses for branch circuits. Simply maintain a 2:1 ratio with upstream Amp-Trap 2000 fuses and the system will coordinate. Many circuit breakers will coordinate easily with downstream fuses. A system that is selectively coordinated will ensure that any fault condition is localized to the nearest overcurrent protective device. This increases system reliability and decreases downtime. Selective coordination is desired for all systems but is also mandatory per NEC for critical circuits: 620.62 Elevator Circuits 700.27 Emergency Systems 701.18 Legally Required Standby Systems By localizing a fault to the nearest overcurrent device selective coordination prevents unnecessarily disconnecting other circuits in the system. An electrical system that utilizes Mersen fuses can simply be selectively coordinated by meeting the minimum amp rating ratios. By adhering to the minimum fuse ratios engineers and installers can save time and money because no complex coordination study is required. Surge Protection In 2014, NEC added article 700.8 which requires that a surge protective device must be installed in or on all new emergency system panelboards. NEC defines emergency systems as legally required systems intended to automatically supply illumination, power and systems essential for safety to human life. MFCP helps easily meet this requirement with the optional built-in Surge-Trap pluggable. Surge-Trap utilizes Mersen s patented fail-safe TPMOV technology. Ordering Details MFCP is a highly configurable panelboard with many options. Please contact Mersen Technical Services at 978-465-4853 or technicalservice.nby@mersen.com for submittal and bid packages.