MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

Similar documents
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

VHIA High-Static Ducted Indoor Units - 60HZ

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Vertical Hi-Rise Fan Coil Unit (Model FS)

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Vertical Floor Fan Coil Unit (Model FW)

FMU4X, FMC4X FMU4Z, FMC4Z

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

DESCRIPTION FEATURES

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

FCVC Series VERTICAL FAN COILS

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

Package Air Conditioners

Q7RE Series Single Packaged Heat Pump, Single Phase

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

MCE4 FEATURES REFRIGERANT SYSTEM CABINET BLOWER CONTROLS INSTALLATION WARRANTY. Electric Heating / Electric Cooling Packaged Units

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

Concealed Ducted Split Series R22

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

HCH6. Product Specifications

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

ELECTRIC HEAT AIR HANDLERS

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

CONDENSING UNITS RAKB- SERIES. Seven Models

Q7RE Series Single Packaged Heat Pump, Single Phase

Serenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog.

High Performance Fan Coils FCHG Genesis Series Horizontal

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

EQUIPMENT TECHNICAL SUBMITTAL FOR APPROVAL DATE SUBMITTED APPROVED AS NOTED: NOT APPROVED PLEASE RESUBMIT

TECHNICAL GUIDE SINGLE PIECE FAN COIL/AIR HANDLER FOR USE WITH SPLIT SYSTEM COOLING ONLY ELECTRIC OR HYDRONIC HEAT AND HEAT PUMPS

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

Modular Variable Speed Air Handlers

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

TECHNICAL SPECIFICATIONS

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER

ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump. Submittal Data English Language/IP Units SD1022AGA 05/14

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

CONDENSING UNITS CLASSIC X CONDENSING UNITS RAKA- SERIES. Seven Models. Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.

GUIDE SPECIFICATIONS. ES Series R-410A

FORM NO. PTZ-806 REV. 1 HEAT PUMPS

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

Residential Packaged Geothermal Heat Pump

R-22, 13 SEER 60 Hertz

V High Efficiency Series

FN Fan-Coil Units High-Performance, Horizontal

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

Transcription:

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3

HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model Number: MHWW-24-H-1 Part 1-General 1.01 System Description Multiaqua Chilled Water Fan Coils are manufactured with high impact molded polymers. 1.02 Quality Assurance A. Certified in accordance with U.L. Standard 95, latest version (U.S.A.) B. Manufactured in a facility registered to ISO 9002, Manufacturing Quality Standard. C. Fully load tested at the factory. D. Damage resistant packaging. 1.03 Delivery, Storage and Handling A. Packaged and readied for shipment from the factory. B. Controls shall be capable of withstanding 150 F storage temperatures in the control compartment. C. Stored and handled per manufacturer s recommendations. Part 2-Product 2.01 Equipment A. General: 1. Unit shall be a factory assembled and tested chilled and hot water fan coil. 2. Shall be assembled with high quality. 3. Contained with the unit shall be all factory wiring, piping, associated controls and special accessories required prior to start up. B. Unit Cabinet: 1. Composed of high impact polymers. 2. Shall be internally insulated to ensure quiet operation. C. Fan Motors: 1. Shall be 208/230-1-50/60 VAC. 2. Fan motors shall be three speed, direct drive, and PSC type. 3. Totally enclosed. 4. Internal overload protected. 5. Unit shall contain a swing motor to modulate the discharge air. D. Blower Wheels: 1. Blower wheels are dynamically balanced. E. Water Coil: 1. Manufactured with water coils containing 3/8 copper tubing mechanically bonded to aluminum fins. 2. Coils shall be factory tested to 300 psig. 3. Maximum inlet water temperature 160 F. F. Drain Pan: 1. All drain pans shall be molded with high impact polymers. 2. The exterior of all drain pans shall be insulated with closed cell insulation to prevent condensation. 3. Pans shall contain flexible drain tubing that is accessible from the back of the unit. G. Filters: 1. Unit shall contain washable filters. These specifications are subject to change without notice. Check www.multiaqua.com for the latest information. 2

Part 3-Controls and Safeties 3.01 Controls A. Fan coils shall be completely factory wired and tested. B. Controls shall include a circuit board, room sensor, indoor coil thermistor, transformer and wireless remote. C. Controls shall be capable of incorporating an optional hard-wired thermostat. 3.02 Safeties: A. Fan coil shall contain a non reusable fuse on the secondary voltage side of the transformer. Part 4-Operating Characteristics: 4.01 Electrical Requirements A. Unit shall be supplied with a three prong male primary electrical power cord. B. Electrical power supply shall be rated to withstand 120 F operating ambient temperatures. Part 5- Definitions: 5.01 Abbreviations A. CFM = Cubic Feet per Minute B. DB = Dry Bulb Temperature C. EWT = Entering Water Temperature D. GPM = US Gallons Per Minute E. MBH = BTU X 1000 F. SC = Sensible Cooling G. TC = Total Cooling = Sensible + Latent H. WB = Wet Bulb Temperature I. WPD = Water Pressure Drop in feet of head J. db = Decibel Level K. m = Meter L. In = Inches M. FPI = Fins per Inch N. OD = Outside Diameter O. ID = Inside Diameter P. MCA = Minimum Circuit Amps Q. MOP = Maximum Over current Protection R. LBS = Pounds U.S. 5.02 Measurements A. All measurements with regard to length, width, and height shall be in inches. These specifications are subject to change without notice. Check www.multiaqua.com for the latest information. 3

208/230-1-50/60 MHWW-24-H-1 Product Specifications Physical Data Model Number Height Length Depth Weight (lbs) Cooling Rows FPI Copper Diameter Water Inlet Water Outlet Drain MHWW-24-H-1 14.17 46.14 8.10 46.20 3-18 3/8 1/2 1/2 3/4 Electrical Data Model Number High Speed CFM Volts/ Phase/ Hertz Fan Motor HP Full Load Ampacity Fuse or HACR Circuit Breaker Per Circuit MCA MOP MHWW-24-H-1 600 1/20 0.35.44 5 These specifications are subject to change without notice. Check www.multiaqua.com for the latest information. 4

MHWW-24-H-1 Chilled Water Performance Data CFM MHWW-24-H-1 COOLING CAPACITIES EWT ( F) 600* 42 *High Speed GPM 6.0 6.5 7.0 7.5 ENTERING AIR TEMPERATURE ( F) 80 D.B. / 67 W.B. TC 26588 SC 17789 WPD 14.5 TC 27214 SC 18071 WPD 16.8 TC 27717 SC 18302 WPD 19.3 TC 28173 SC 18512 WPD 21.9 CFM MHWW-24-H-1 COOLING CAPACITIES EWT ( F) 600* 45 *High Speed GPM 6.0 6.5 7.0 7.5 ENTERING AIR TEMPERATURE ( F) 80 D.B. / 67 W.B. TC 23669 SC 16507 WPD 14.4 TC 24248 SC 16760 WPD 16.7 TC 24719 SC 17003 WPD 19.2 TC 25118 SC 17182 WPD 21.8 Recommended minimum flow rate for this unit at > 2fps is 2.75 gpm Recommended maximum flow rate for this unit at < 6fps is 7.75 gpm These specifications are subject to change without notice. Check www.multiaqua.com for the latest information. 5

MHWW-24-H-1 Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered MHWW-24-H-1 HEATING CAPACITIES ENTERING ENTERING WATER TEMPERATURE ( F) CFM GPM WPD AIR ( F) 90 100 110 120 130 140 150 160 6.0 13.4 21380 26787 32212 37653 43106 48569 54039 59516 6.5 15.5 21555 27002 32466 37945 43436 48936 54444 59957 50 600 7.0 17.8 21705 27186 32684 38196 43719 49251 54790 60334 7.5 20.3 21835 27346 32873 38414 43964 49523 55089 60660 MHWW-24-H-1 HEATING CAPACITIES ENTERING ENTERING WATER TEMPERATURE ( F) CFM GPM WPD AIR ( F) 90 100 110 120 130 140 150 160 6.0 13.4 16053 21446 26859 32289 37733 43187 48650 54121 6.5 15.5 16183 21617 27070 32539 38021 43513 49013 54520 60 600 7.0 17.8 16295 21763 27251 32753 38267 43791 49323 54861 7.5 20.3 16391 21891 27407 32938 38481 44032 49591 55156 MHWW-24-H-1 HEATING CAPACITIES ENTERING ENTERING WATER TEMPERATURE ( F) CFM GPM WPD AIR ( F) 90 100 110 120 130 140 150 160 6.0 13.3 10722 16102 21504 26923 32358 37804 43260 48724 6.5 15.5 10807 16229 21671 27130 32603 38088 43581 49082 70 600 7.0 17.8 10881 16338 21815 27308 32814 38330 43856 49388 7.5 20.2 10945 16433 21939 27461 32996 38540 44093 49653 MHWW-24-H-1 HEATING CAPACITIES ENTERING ENTERING WATER TEMPERATURE ( F) CFM GPM WPD AIR ( F) 90 100 110 120 130 140 150 160 6.0 13.3 5385 10753 16144 21553 26978 32417 37865 43322 6.5 15.4 5427 10837 16268 21718 27182 32658 38145 43639 80 600 7.0 17.7 5463 10909 16375 21859 27356 32866 38384 43910 7.5 20.1 5494 10971 16468 21981 27507 33045 38591 44145 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: ENTERING AIR TEMPERATURE 70 F DB / 60 F WB GPM ENTERING WATER TEMPERATURE 140 F 6.0 38177 6.5 38470 7.0 38720 7.5 38937 These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.

MHWW-24-H-1 Sound Data MODEL # MHWW-24-H-1 Fan Speed db @ 1 m H 43 M 42 L 40 These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.

MHWW-24-H-1 Dimensional Drawing These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.