LINCOLN ENVIRONMENTAL SYSTEMS

Similar documents
FUME DOESN T STAND A CHANCE

Inverter Welding System

LN-9 AND LN-9 GMA. Semiautomatic Wire Feeders THE WELDING EXPERTS

THE AUTOWELD SYSTEM. Automated Pipe Welding System. High Productivity

Description. Order TECHNICAL SPECIFICATIONS

LF-72 AND LF-74 WIRE FEEDERS

LF-72 and LF-74 Wire Feeders

TECHNICAL SPECIFICATIONS

LF-72 and LF-74 Wire Feeders

LF-72 and LF-74 Wire Feeders

Power Feed 10R. Compact Wire Drive System for Automation. Processes. Description. Recommended General Options. Advantage Lincoln

POWER MIG 210 MP MULTI-PROCESS WELDING MACHINE

ZIPLINE BOOM PACKAGE. Operator s Manual. IM10184 Issue D ated Dec- 13 Lincoln Global, Inc. All Rights Reserved.

CrossLinc TECHNOLOGY FULL CONTROL. FEWER CABLES.

CROSSLINC TECHNOLOGY FULL CONTROL. FEWER CABLES.

FLEXTEC MULTI-PROCESS WELDERS FLEXTEC 350X, 500, 500P, 650

K Model Shown. (1) With CV Adapter. TECHNICAL SPECIFICATIONS

WELD STRONG BREATHE FREE

DUAL VANTAGE 800 ENGINE-DRIVEN WELDER/GENERATOR

TECHNICAL SPECIFICATIONS

SAE-500 Severe Duty ENGINE-DRIVEN WELDER / GENERATOR

FLEXTEC MULTI-PROCESS WELDERS FLEXTEC 350X, 500, 500P, 650

INDUSTRIAL WIRE FEEDERS FLEX FEED 74 HT, FLEX FEED 84 AND POWER FEED 84

SECTION WELDING FUME EXHAUST SYSTEM

DUAL VANTAGE 800-I ENGINE-DRIVEN WELDER/GENERATOR

Fume extractor is warranted for two years, parts and labor.

PRICE LIST 08/2008. GROSS prices in L19. Validity: August 1 December 31, 2008

MULTI-PROCESS POWER FOR HEAVY DUTY APPLICATIONS

POWER MIG 260 FABRICATION SIMPLIFIED

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

SAE-400 Processes Stick, TIG, Flux-Cored (1), Gouging (1) With CV Adapter.

LN-8. Semiautomatic Wire Feeder LINCOLN ELECTRIC

DIGIPULS III 320C DIGISTEEL III 320C

PRO Robotic Guns. Thru-Arm Torch Current Range: 550A Duty Cycle: 100% Wire Diameter:.035-5/64 in. ( mm) APPLICATIONS

Installation & Service Manual for Portable Fume Collector. Model PFC-800

Precision TIG 375. The Power To Perform! Advantage Lincoln TIG WELDERS. Output. Input 1 PHASE. Publication E /05

WELDING FUME EXHAUSTERS & ARMS

Leading the way for clean air in the new millennium. S o u r c e C a p t u r e

APPENDIX A 30 WELDING BOOTHS AND FUME EXHAUST SYSTEM

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration

MODEL FA1 Mini Air Filtration System. Operations Manual

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

ABOVE-FLOOR WHEEL LATHE

UNDER-FLOOR WHEEL LATHE

Air Boss M-Series Media & Adsorption Air Cleaner

TECHNICAL SPECIFICATIONS

LINC GUN THE ULTIMATE MIG GUNS

SIRIOCOPT. A new handle that changes everything.

Installation & Service Manual for Horizontal Cartridge Filtration Systems

Fume Extraction & Dust Collection

Affordable portable filtration unit

Exhaust hose reels. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. Car and truck dealerships

Portable HEPA System

CA3000C & CA6000C Cartridge Air Cleaners

There are two general ways to capture airborne pollutants:

FA1 Series Air Filtration System. Operations Manual

PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS. The Complete Plug-and-Play Solution

Hose drop for fume and gases exhaust systems

Tube Axial Inline Fans

SERIES 100 OWNER'S MANUAL. Installation, Operation & Maintenance TOUGH PORTABLES MODEL S130

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

Power Wave AC/DC Submerged Arc

MODEL FA5 Air Filtration System. Operations Manual

MODEL GS1-100 Air Filtration System. Operations Manual

Owner s manual for installation, usage and maintenance

Electric Portable Dry Vacuums

MAKE WORK FLY. Eagle 10,000 Plus KEY FEATURES

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

AUTOMATION SOLUTIONS THAT MEET THE MOST DEMANDING REQUIREMENTS YOURS.

Product catalogue 2010

Subarc DC Series. Processes Submerged Arc (SAW) Stick (SMAW) Air Carbon Arc Cutting and Gouging (CAC-A) Subarc DC 650 shown.

Dust Collectors and Fume Exhausters

36" Explosion Proof High Velocity Rollback Fan CFM - 1-1/2 HP - 115/230V - C1D1 - C2D1

SF-1000 workbench - welding table. User s Manual.

FilterMax F. Modular dust collector with integrated pre-separator

Exhaust hose reels. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. Car and truck dealerships

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

JUMBO. Fume Extraction Technology. Compact and Versatile. Filtertrolley 2.0. Extraction. Filtration. Persistence.

V350-PRO. (1) Advanced Process Panel only. TECHNICAL SPECIFICATIONS

FilterMax F. Modular dust collector with integrated pre-separator

Denray Machine s Product Catalog

DUST COLLECTORS. Stronger. Better. CLEANER.

THE INTELIAIR TM. i2m AND i3m FUME EXTRACTION ARMS KEY FEATURES

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Exhaust hose reels. AQC source capture equipment. Sept 11, 2008 version. Leaflet under construction. More information to come at a later date.

Direct Gas-Fired Heating

About Vacuum Producers

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

A. NU2035 HRV Specifications NU2035

FilterMax DF. Modular dust multi purpose collector. Models

Product manual Junior LM-2

VANTAGE 520 SD ENGINE-DRIVEN WELDERS/GENERATORS

ENGINEERED FOR EXCEPTIONAL PERFORMANCE.

Tubular Centrifugal Fans

INDUSTRIAL AIR FILTRATION SYSTEMS PLTF JET-PULSE PLEATED BAG HOUSE FILTER

filtration technology for grain industries

Transcription:

LINCOLN ENVIRONMENTAL SYSTEMS Low-Vacuum Solutions ProSource LV s

ProSource LOW VACUUM SOLUTIONS PAGE NO. MOBILE SYSTEMS Mobiflex 100-NF Portable Fan...3 Mobiflex 200-M: Mobile Fan, Filtration & Extraction Arm...4 & 5 Mobiflex 400-MS: Mobile Fan, Self-Cleaning Filtration & Extraction Arm...6 & 7 (For Mobile Units with 16 ft. of Flexible Hose, see p.14) EXTRACTION ARMS LFA 3.1, 10 ft. Spring Balanced Arm...8 LFA 4.1, 13 ft. Spring Balanced Arm...8 (For Package Ordering Info., see p.5 & 7 for Mobile Systems, 16 & 17 for Wall Mounted Systems) TELESCOPIC ARMS LTA 2.0, Telescopic Arm...9 (For Package Ordering Info., see p. 16 & 17) STATIONARY FANS SF2400 Stationary Fan...10 (For Package Ordering Info., see p. 16 & 17) EXTENSION CRANES Extension Cranes...11 (For Package Ordering Info., see p. 16 & 17) SINGLE STATION FILTRATION Statiflex 200-M...12 Statiflex 400-MS...13 (For Package Ordering Info., see p. 16 & 17) MOBIFLEX XL SYSTEMS (MOBILE FAN & FILTRATION WITH 16 FT. FLEXIBLE HOSE)...14 PROSOURCE LV ACCESSORIES...15 ORDERING WALL MOUNTED SYSTEMS...16 & 17 LOW VACUUM CENTRAL SYSTEMS WITH STATIFLEX 6000-MS...18 & 19 2

MOBIFLEX 100-NF PORTABLE FAN For hard to reach areas, exhaust the fume with the Mobiflex 100-NF and hose set. Connect to 6 in. diameter, 16 ft. long K1668-1 hose set with magnet mounted hood and 6 in. x 16 ft. K1668-2 exhaust or extension hose set. Does not provide filtration. If using one inlet hose (K1668-1), use maximum of two outlet hoses (two K1668-2). If using two inlet hoses (K1668-1 & -2), use maximum of one outlet hose (K1668-2). For fan data, see SF2400 (p.10). ADVANTAGE LINCOLN For hard to reach places. Lightweight and portable, 37.5 lbs. (17 kg). Steel rings protect hose. Maximum noise level 69dBA. Airflow with one K1668-1 on inlet and one K1668-2 on outlet: 675 CFM Specifications Mobiflex 100-NF Portable Fan Number K1666-1 60Hz Input Power 115V, 11 Amps Dimensions H x W x L 23.2 x 19 x 19 in. (587 x 480 x 480 mm) 37.5 lbs. (17 kg) Hose and Hood Set (not included in K1666-1) K1668-1 N/A 6 in. x 16 ft. (160 x 5000 mm) 22 lbs. (10 kg.) Exhaust or Extension Hose Set (not included in K1666-1) K1668-2 N/A 6 in. x 16 ft. (160 x 5000 mm) 16 lbs. (7 kg.) 3

MOBIFLEX 200-M ADVANTAGE LINCOLN Lincoln s ProSource LV low vacuum fume extraction products combine the finest features in the industry with the best value. The Mobilflex 200-M provides mobile fume extraction with either a 10 ft. or 13 ft. spring balanced extraction arm. By using durable, dent-resistant thermoplastic tubes, the lightweight arms position easily and hold their place without drifting. The Mobiflex 200-M draws air through the self-cleaning fan and spark arrestor and captures welding fume inside the unique LongLife filter. Particulate is collected on the inside of the cartridge, rather than the outside, keeping hands clean during filter maintenance. Lincoln s 472 ft 2 LongLife cartridge is more than twice the size of the leading competitor. Along with ExtraCoat surface treatment and 3-dimensional pleating, this generous size provides longer life than other disposable cartridge systems. The Mobiflex 200-M also features a filter maintenance indicator. This indicator changes gradually from white to red as the filter becomes saturated with welding fume. This shows ahead of time how close the filter is to clogging. Mobile low vacuum system provides 735 CFM airflow. LFA flexible arms feature: - 10 ft. or 13 ft. lengths. - Spring balanced for easy positioning. - 360 rotatable hood. - Airflow throttle valve. Generous 472 ft 2 surface treated filter cartridge included (K1673-1). Quiet operation: 69dBA. Filtration efficiency of 99.8%. Maintenance indicator gauges the amount of dust build-up in the filter. Includes aluminum spark arrestor. Optional work lamp provides lamp and hood mounted switches for both lamp and fan. Order K1706-1 without arc sensor, or K1706-2 with arc sensor. Automatic start/stop arc sensor, built into K1706-2 work lamp, detects arc flash to start and stop fan. Recommended for annual electrode use of less than 1,500 lbs. per station (1,100 lbs. for SMAW or FCAW). For heavier duty application, use Mobiflex 400-MS (see page 6). 4

A CLOSER LOOK Mobiflex 200-M with LongLife Filter. Reach of the Mobiflex 200-M Mobiflex 200-M with LFA 4.1 13 ft. Extraction Arm. 10 ft. Package Ordering Information 60Hz Input Power Dimensions H x W x L Mobiflex 200-M Base Unit K1653-2 115V, 11 Amps* 35 x 32 x 48 in. (900 x 810 x 1210 mm) 243 lbs. (111 kg.) LFA 3.1 10 ft. Fume Extraction Arm K1655-1 N/A 8 x 118 in. (208 x 3000 mm) 33 lbs. (15 kg.) 13 ft. Package (For 16 ft. Hose Packages, see p. 14) Ordering Information 60Hz Input Power Dimensions H x W x L Mobiflex 200-M Base Unit K1653-2 115V, 11 Amps* 35 x 32 x 48 in. (900 x 810 x 1210 mm) 243 lbs. (111 kg.) LFA 4.1 13 ft. Fume Extraction Arm K1655-2 N/A 8 x 157 in. (208 x 4000 mm) 38 lbs. (17 kg.) * 230V operation available with K1494-3 Starter Overload Switch. Accessories Ordering Information Ordering Information Work Lamp for Mobiflex 200-M (K1653-2) and 400-MS Work Lamp w/arc Sensor for Mobiflex 200-M (K1653-2) and 400-MS K1706-1 K1706-2 230V Starter/Overload Switch (for converting to 230V operation) Automatic Start/Stop Arc Sensor to retrofit K1706-1 or K1669-1 work lamp K1494-3 K1670-1** ** K1670-1 not required if using K1706-2. 5

MOBIFLEX 400-MS ADVANTAGE LINCOLN For heavy duty applications, use the Mobiflex 400-MS. The Mobiflex 400- MS provides all the excellent features of the Mobiflex 200-M, but with automatic filter cleaning. When the filter becomes dirty, a pressure sensor activates the cleaning system. Compressed air from the tank releases through multiple air-jets to clean one section of the filter at a time. A complete cleaning cycle can also be activated by a manual switch. Dust is knocked off of the cartridge into a removable drawer. The Mobiflex 400-MS uses either 10 ft. or 13 ft., spring balanced extraction arms to capture fume. Air is drawn through the self-cleaning fan blades, through the aluminum mesh spark arrestor, and then through the generous, 287 ft 2 filter cartridge (26m 2 ). This cartridge is larger than competitive filters, providing long life and low downtime. ExtraCoat surface treatment and 3-dimensional pleating provide enhanced performance and life. Mobile low vacuum system provides 735 CFM of airflow. LFA Flexible arms feature: - 10 ft. or 13 ft. length - Spring balanced for easy positioning. - 360 rotatable hood. - Airflow throttle valve. Industrial duty filter cleaning system automatically cleans the cartridge with shop compressed air. Multiple air-jets clean one section of the filter at a time based upon differential pressure or a manual switch. Generous 287 ft 2 (26m 2 ) surface treated filter cartridge included (K1673-2). Filtration efficiency of 99.8%. Quiet operation: 69dBA. Light indicates saturated filter. Aluminum mesh spark arrestor. Recommended for annual electrode use of more than 1,500 lbs. per station (1,100 lbs. of SMAW or FCAW). For lighter duty applications, use Mobiflex 200M (pages 4 and 5). 6

A CLOSER LOOK Reach of the Mobiflex 400-MS Mobiflex 400-MS shown with K1655-1 LFA 3.1 Arm (sold separately). 10 ft. (3m) Package Ordering Information 60Hz Input Power Dimensions H x W x L Mobiflex 400-MS Base Unit K1741-1 115V, 11 Amps* 40 x 31 x 48 in. (1020 x 810 x 1200 mm) 286 lbs. (130 kg.) LFA 3.1 10 ft. Fume Extraction Arm K1655-1 N/A 8 x 118 in. (208 x 3000 mm) 33 lbs. (15 kg.) 13 ft. (4m) Package (For 16 ft. Hose Packages, see p. 14) Ordering Information 60Hz Input Power Dimensions H x W x L Mobiflex 400-MS Base Unit K1741-1 115V, 11 Amps* 40 x 31 x 48 in. (1020 x 810 x 1200 mm) 286 lbs. (130 kg.) LFA 4.1 13 ft. Fume Extraction Arm K1655-2 N/A 8 x 157 in. (208 x 4000 mm) 38 lbs. (17 kg.) * 230V operation available with K1494-3 Starter Overload Switch. Accessories Ordering Information Ordering Information Work Lamp for Mobiflex 400-MS (and K1653-2) K1706-1 230V Starter/Overload Switch (for converting to 230V operation) K1494-3 Work Lamp w/arc Sensor for Mobiflex 400-MS (and K1653-2) K1706-2 Automatic Start/Stop Sensor to retrofit K1706-1 work lamp. K1670-1** ** K1670-1 not required if using K1706-2. 7

LFA 3.1/4.1 FUME EXTRACTION ARMS Lincoln s LFA spring balanced extraction arms offer the finest ease of positioning available. Our unique design not only moves easily, but holds in place once positioned. The rugged dent-resistant plastic construction provides both light weight and durability. Combine the LFA arms with either a Mobiflex or wall mounted package (see page 2). Shown with SF2400 Fan (p.10) and Wall Bracket. ADVANTAGE LINCOLN Reach of the LFA 3.1/4.1 Vacuum Inches (WG) LFA 3.1/4.1 Pressure Drop SF2400 10 ft. or 13 ft. length (wall mounted reach of 11 ft.-14 ft.). Spring balanced for easy positioning. 360º rotatable hood. Airflow throttle valve. Airflow focus vanes. Lightweight, rugged, dent resistant plastic construction. Optional Lamp Kits available. Provides hood mounted switches for both lamp and fan (for kits without Arc Sensor, order K1706-1 for Mobiflex packages, K1669-2 for wall mounted systems). LFA 3.1/4.1 CFM Automatic Start/Stop Arc Sensor (built into K1706-2 and K1669-4 lamp kits). Detects arc flash to start and stop fan (lamp required). K1670-1 retrofits plain lamp kits K1706-1 and K1669-2. Specifications (see pages 5, 7 or 16 for complete ordering information) LFA 3.1 10 ft. Fume Extraction Arm Number Dimensions K1655-1 8 x 118 in. (208 x 3000 mm) 33 lbs. (15 kg.) LFA 4.1 13 ft. Fume Extraction Arm K1655-2 8 x 157 in. (208 x 4000 mm) 37.5 lbs. (17 kg.) 8

LTA 2.0 TELESCOPIC FUME EXTRACTION ARM Vacuum Inches (WG) LTA 2.0 Pressure Drop SF2400 Fan Curve Lincoln s LTA 2.0 Telescopic Extraction Arm offers ease of positioning in a small package, perfect for small workstations or schools. The arm retracts and extends from 3 ft. to 4.5 ft., and pivots up to 45. The arm also comes with a wall mounting bracket (Motor mounting bracket required if using the SF2400 Fan). ADVANTAGE LINCOLN CFM Telescopes from 3 ft. to 4.5 ft. Perfect for schools and small workstations. 360 rotatable hood. Airflow throttle valve. All Lincoln Hoods Rotate 360 Shown with Fan and Motor Mounting Bracket Lightweight, rugged, dent resistant plastic construction. Optional lamp kits are available. Provides hood mounted switches for both lamp and fan kit. Without arc sensor: K1669-2, with arc sensor built-in: K1669-4. Automatic start/stop Arc Sensor (built into K1669-4 lamp kit) detects arc flash to start and stop fan (lamp required). K1670-1 retrofits K1669-2 plain lamp kits. Reach of the LTA 2.0 Specifications (see page 17 for complete ordering information) LTA 2.0 Telescopic Extraction Arm K1655-3 Number Dimensions 8 x 39.5-55 in. (208 x 1000-1400 mm) 15.4 lbs. (7 kg.) 9

SF2400 FAN Lincoln s SF2400 Fan provides single station extraction for LFA and LTA extraction arms, or for hoods or other ventilation installations. The 1 HP, 115V* fan can also be combined with the Statiflex 200-M for wall mounted filtration. Fan Curve SF 2400 ADVANTAGE LINCOLN Vacuum Inches (WG) Generous airflow: - 1200 CFM free blowing - 880 CFM with LTA 2.0 Arm - 760 CFM with LFA 3.1/4.1 Arm Concave fan blades self-clean. 115V, 60Hz, 11 Amps. 1HP. Specifications (see pages 16 and 17 for complete ordering information ). CFM Requires K1657-1 wall mounting bracket for use with LFA 3.1 or LFA 4.1. Requires K1657-2 motor mounting bracket for use with LTA 2.0, extension cranes or ventilation hoods without arms. Number SF2400 Fan K1656-1 Horsepower 60Hz Input Power 1HP (0.75 kw) 115V, 11 Amps* Dimensions H x W x L 15 x 19 x 20 in. (370 x 480 x 500 mm) 33 lbs. (15 kg.) * 230V operation available with K1494-3 starter overload switch, or by adding K1750-1 conversion kit to a lamp kit. 10

EXTENSION CRANES For large work areas, use Lincoln s 7 ft. or 14 ft. extension crane. The side-to-side hinge at the wall has a unique spring controlled lock to hold the arm in place for steady positioning. Add the K1672-1 Feeder Hanging Rail to suspend your wire feeder on a slide mounted to the first crane section. Each crane includes support boom, mounting plate, 8 tubing, flexible hose and arm mounting brackets. K1657-1 is not required. If using an SF2400 Fan, use the K1657-2 for fan mounting. EXTENSION CRANES Vacuum Inches (WG) SF2400 Fan Curve CFM Specifications (see page 16 for complete ordering information). Extension Crane, 7 ft. Extension Crane, 14 ft. Feeder Hanging Rail Number K1671-1 K1671-2 K1672-1 62 lbs. (28 kg.) 106 lbs. (48 kg.) 8 lbs. (3.5 kg.) 11

STATIFLEX 200-M FILTER UNIT ADVANTAGE LINCOLN Add filtration to wall mounted or stationary packages with the Statiflex 200-M filter unit. This is the identical filter system to the Mobiflex 200-M, drawing fume through a spark arrestor into the inside of the LongLife cartridge. Particulate is collected on the inside of the cartridge, rather than the outside, keeping hands clean during filter maintenance. Lincoln s 472 ft 2 LongLife cartridge is more than twice the size of the leading competitor. Along with ExtraCoat surface treatment and 3-dimensional pleating, this generous size provides longer life than other disposable cartridge systems. The Statiflex 200-M also features a filter maintenance indicator. This indicator moves gradually from white to red as the filter becomes saturated with welding fume, letting you know ahead of time how close the filter is to clogging. Stationary filtration for wall mounted arms or stationary ventilation. Generous 472 ft 2 surface treated filter cartridge included (K1673-1). Filtration efficiency of 99.8%. Maintenance indicator gauges the amount of dust buildup in the filter. Includes spark arrestor. Recommended for annual electrode use of less than 1,500 lbs. per station (1,100 lbs. for SMAW or FCAW). For heavier duty applications, use Statiflex 400-MS (page 13). Specifications (see pages 16 and 17 for complete ordering information). Statiflex 200-M Number K1654-1 Filter Type Pretreated Paper Filter Surface Area 472 ft 2 (45 m 2 ) Dimensions H x W x L 35.5 x 32 x 29 in. (900 x 810 x 730 mm) 66 lbs. (30 kg.) For multi-station filtration, see the Statiflex 6000-MS (pages 18 & 19). 12

STATIFLEX 400-MS FILTER UNIT For heavy duty applications, use the Statiflex 400-MS. The Statiflex 400-MS provides all the excellent features of the Statiflex 200-M for wall mounted arms or stationary filtration, but with automatic filter cleaning. When the filter becomes dirty, a pressure sensor activates the cleaning system. Compressed air from the tank releases through multiple air-jets to clean one section of the filter at a time. A complete cleaning cycle can also be activated by a manual switch. Dust is knocked off of the cartridge into a plastic bag accessed through a hatch at the bottom. Air is drawn through the aluminum mesh spark arrestor, through the generous, 287 ft 2 filter cartridge (26m 2 ). This cartridge is larger than competitive filters, providing long life and low down-time. ExtraCoat surface treatment and 3-dimensional pleating provide enhanced performance and life. Stationary Filtration for wall mounted arms or stationary ventilation. Industrial duty filter cleaning system automatically cleans the cartridge with shop compressed air. Multiple air-jets clean one section of the filter at a time based upon differential pressure or a manual switch. Generous 287 ft 2 (26m 2 ) surface treated filter cartridge included (K1673-2). Filtration Efficiency of 99.8%. Light indicates saturated filter. Aluminum mesh spark arrestor. Recommended for annual electrode use of more than 1,500 lbs per station (1,100 lbs of SMAW or FCAW). For lighter duty applications, use Statiflex 200M (page 12). Specifications (see page 17 for complete ordering information). Statiflex 400-MS Number K1742-1 Filter Type Pretreated Paper Filter Surface Area 287 ft 2 (26 m 2 ) Dimensions H x W x L 41x 27 x 26 in. (1040 x 670 x 660 mm) 187 lbs. (85 kg.) For multi-station filtration, see the Statiflex 6000-MS (pages 18 & 19). 13

MOBIFLEX XL SYSTEMS For extended reach with filtration, package hose & hood sets with Mobiflex 200-M or 400-MS. One 16 ft. length yields an estimated 650 CFM of airflow. See pages 3-7 for more information on components. Select Mobiflex 200-M for standard duty applications (less than 1,500 lbs. of solid wire per station per year - 1,100 lbs. of cored wire or stick rod per year), or the mobiflex 400-MS for self-cleaning filtration in heavy duty applications (more than 1,500 lbs. of solid wire or 1,100 lbs. of cored wire or rod). Tapered connection flange provides 6 in. connection for the hose & hood set, with magnet mounted hood, or 8 in. connection for 8 in. hose. Hose & hood set comes standard with 6 in. hose, reinforced with outside steel rings to protect against abrasion & crushing. Mobiflex 200-M-XL Package Mobiflex 200-M Base Unit Hose & Hood Set, 16 ft. Connection Flange (6 & 8 in.) Ordering Information K1653-2 K1668-1 S23267 60Hz Input Power 115V, 11 Amps * N/A N/A Dimensions H x W x L (mm) 35 x 32 x 48 in. (900 x 810 x 1210 mm) 6 in. x 16 ft. (160 x 5000 mm) 6 in. and 8 in. Connections Lbs. (kg) 243 Lbs. (111 kg) 22 Lbs. (10 kg) 1 Lb. (0.5kg) Mobiflex 400-MS-XL Package Mobiflex 400-MS Base Unit Hose & Hood Set, 16 ft. Connection Flange (6 & 8 in.) Ordering Information K1741-1 K1668-1 S23267 60Hz Input Power 115V, 11 Amps * N/A N/A Dimensions H x W x L (mm) 40 x 32 x 48 in. (1020 x 810 x 1210 mm) 6 in. x 16 ft. (160 x 5000 mm) 6 in. and 8 in. Connections Lbs. (kg) 243 Lbs. (111 kg) 22 Lbs. (10 kg) 1 Lb. (0.5kg) * 230V operation available with K1494-3 conversion kit. 14

PROSOURCE LV ACCESSORIES ProSource LV Accessories Lamp Kits Mounts in LFA or LTA Hoods and provides 35W lamp and switch. Switch also provides hood-mounted on/off control of either Mobiflex fan or SF2400 fan. All Lamp kits come with lamp housing and switch housing (both of which snap into the hoods), bulb, switch, connection board and interconnecting wiring. Some Lamp Kits include Arc Sensor built into lamp housing (see below). Wall mounted lamp kits include control box with motor starter, 24V transformer and overload relay for fan. Wall mounted systems do not need K1494-2 or -3 when using lamp kit. Retrofit wall mounted lamp kits for 230V operation of SF2400 Fan with K1750-1. Automatic Start/Stop Arc Sensor Mounted in the lamp housing, the arc sensor turns the fan on when sensing the arc flash light, and turns the fan off 20 seconds after the arc goes out. Order Lamp kits with arc sensor built-in or order K1670-1 to retrofit plain lamp kits (K1669-2 or K1706-1). A lamp housing is required to mount and operate the arc sensor. 35W Lamp On/Off Switch Hood mounted on/off switch for fan Available with built-in Arc Sensor Automatic starting and stopping 20 Seconds stop delay Saves Power Reduces noise Mounts in hood with lamp Senses arc flash Lamp Kits Without Arc Sensor Ordering Information Lamp Designed for Includes K1706-1 K1669-2 K1653-2 Mobiflex 200-M with transformer K1741-1 Mobiflex 400-MS Wall mounted systems with SF2400 Fan (115V) Lamp, switch, and 13 ft. cable. Lamp, switch, 36 ft. cable, control box complete with transformer, fan starter, overload relay, fuse, terminal block and wiring. Lamp Kits With Automatic Start/Stop Arc Sensor Built-in Ordering Information Lamp Designed for Includes K1706-2 K1669-4 Other Accessories K1653-2 Mobiflex 200-M with transformer K1741-1 Mobiflex 400-MS Wall mounted systems with SF2400 Fan (115V) Lamp with Arc Sensor, lamp & fan switch, and 13 ft. cable. Lamp with Arc Sensor, lamp & fan switch, 36 ft. cable, control box complete with transformer, fan starter, overload relay, fuse, terminal block and wiring. Ordering Information Description K1670-1 K1494-3 K1750-1 S23267 K1743-1 Automatic Start/Stop Arc Sensor 230V Starter/Overload Switch 230V Conversion Kit for Wall Mounted Lamp Kits Connection Flange 6 Backdraft Damper Sensor PC Board retrofits plain lamp kits (K1706-1, K1669-2). Retrofits Mobiflex 100NF, 200-M and 400-MS for 230V operation. -0R- Replaces K1494-2 for 230V operation of SF2400 fan. Retrofits wall mounted systems with lamp kits (K1669-2 or -4) for 230V operation of SF2400 fan. Connection flange for SF2400 fan. Provides guarded connection for 6 and 8 hose. Backflow damper used when connecting several fans to common ductwork. 15

ORDERING INFORMATION LFA 3.1/4.1 WALL MOUNTED PACKAGES 4. If using SF2400 Fan, select starting controls (wall switch or hood mounted switch included with Lamp Kit). 3. Add SF2400 Fan (if needed) 5. To add filtration, select Statiflex 200-M, Statiflex 400-MS, or Statiflex 6000-MS. 6. Add accessories. 2. Add Wall Bracket* 7. Add ductwork if needed (supplied locally). 1. Select Arm 16 1. Select Arm (p.8) LFA 3.1 10 ft. Arm -or- K1655-1 LFA 4.1 13 ft. Arm K1655-2 2. Add Wall Bracket* Wall Mounting Bracket for LFA Arms* K1657-1* 3. Add SF2400 Fan (if needed) (p.10) SF2400 Fan K1656-1 4. Select Fan Starting Controls Starter/Overload Switch 10-16A (115V) K1494-2 (if using SF2400 Fan) (p.15) Starter/Overload Switch 4-6.5A (230V) K1494-3 -OR- Lamp Kit for Wall Mounted Packages (115V) Without Sensor: K1669-2 (Provides Hood Mounted Fan Control) With Sensor: K1669-4 For 230V Operation with Lamp Kit, Add 230V Conversion Kit K1750-1 5. Add Filtration (p.12, 13, 18 & 19) Statiflex 200-M Filter Unit -OR- K1654-1 Statiflex 400-MS Filter Unit with Automatic Cleaning K1742-1 Statiflex 6000-MS Filter Unit for Central Systems ** 6. Add Accessories (p.15 & 11) Lamp Kits (Replaces K1494-2 or -3 Starter/Overload Switch) Without Arc Sensor: K1669-2 With Built-in Arc Sensor: K1669-4 230V Conversion Kit for Lamp Kits (Provides 230V Operation for SF2400 Fan When Using Lamp Kit) K1750-1 Extension Crane, 7 ft* K1671-1 Extension Crane, 14 ft.* K1671-2 Feeder Hanging Rail for Extension Cranes K1672-1 * K1657-1 Wall Mounting Bracket not req. if using an Extension Crane. Use K1657-2 Motor Mounting Bracket if installing SF2400 Fan with Extension Crane. ** Contact the Automation Division for ordering information.

ORDERING INFORMATION 3. Add K1657-2 Motor Mounting Bracket (if using SF2400) LTA 2.0 TELESCOPIC ARM PACKAGES 4. If using SF2400 Fan, select starting controls (wall switch or hood mounted switch included with Lamp Kit). 2. Add SF2400 Fan (if needed) 1. Order K1655-3 LTA 2.0 Arm 5. To add filtration, select Statiflex 200-M, Statiflex 400-MS, or Statiflex 6000-MS. 6. Add accessories. 7. Add ductwork if needed (supplied locally). 1. Select Arm (p.9) LTA 2.0 Telescopic Arm K1655-3 2. Add SF2400 Fan (if needed) (p.10) SF2400 Fan K1656-1 3. Add Motor Mounting Bracket Motor Mounting Bracket for SF2400 Fan K1657-2 (If Using SF2400 Fan) 4. Select Fan Starting Controls (If Using SF2400 Fan) (p.15) Starter/Overload Switch 10-16A (115V) K1494-2 Starter/Overload Switch 4-6.5A (230V) K1494-3 -OR- Lamp Kit for Wall Mounted Packages (115V) Without Sensor: K1669-2 (Provides Hood Mounted Fan Control) With Sensor: K1669-4 For 230V Operation with Lamp Kit, Add 230V Conversion Kit K1750-1 5. Add Filtration (p.10, 13, 18 & 19) Statiflex 200-M Filter Unit -OR- K1654-1 Statiflex 400-MS Filter Unit with Automatic Cleaning K1742-1 Statiflex 6000-MS Filter Unit for Central Systems ** 6. Add Accessories (p.15) Lamp Kits (Replaces K1494-2 or -3 Starter/Overload Switch) Without Arc Sensor: K1669-2 With Built-in Arc Sensor: K1669-4 ** Contact the Automation Division for ordering information. 230V Conversion Kit for Lamp Kits (Provides 230V Operation for SF2400 Fan When Using Lamp Kit) K1750-1 17

ProSource LOW VACUUM CENTRAL SYSTEMS Contact your local Lincoln representative for a custom quotation on Low Vacuum Central Systems, including extraction arms, fans, Statiflex 6000-MS filter systems, ductwork and hardware. With application information, preferred arm size and a shop layout showing location of ductwork, fan and arms, Lincoln can supply you with a complete equipment quotation. Ask about systems for large hoods or downdraft tables. See specifications throughout this sales bulletin for specifications for arms, fans and accessories. See page 19 for specifications on the Statiflex 6000-MS. Centralized fans are custom sized for each quotation, unless using the SF2400 single station fans. ADVANTAGE LINCOLN Custom systems to meet your needs. Automatic filter cleaning. Centralized maintenance. Easy to position, versatile extraction arms. Optional work lamp and work lamp with automatic start/stop arc sensor. Local representation. 18

CENTRAL SYSTEMS WITH THE STATIFLEX 6000-MS For centralized filtration, choose the Statiflex 6000-MS Central Filter Unit. With a capacity of 3750 CFM (6375 m 3 /hr), the Statiflex 6000-MS can provide filtration for up to five extraction arms in use at one time. Systems with more than five arms can keep airflow to acceptable limits by closing airflow throttle valves on extra arms, or by using the automatic arc sensor to start and stop single station fans. With the arc sensor controlling single station fans, worker duty cycle will often keep several fans off while others are on, reducing the number of arms in use. As long as no more than five arms are in use at one time, one Statiflex 6000-MS will meet your needs. The Statiflex 6000-MS System features automatic filter cleaning. Set either at time intervals or with preset pressure settings. The unique filter cleaning system uses multiple jets of compressed air to clean one section of the filter at a time. Dust from the generously sized filters (1400 ft 2 total) is knocked into an easy access drum underneath the unit. ADVANTAGE LINCOLN Two generously sized filter cartridges, totaling 1400 ft 2. Maximum airflow of 3,750 CFM. For five extraction arms or more, if using the automatic start/stop sensor. Automatic filter cleaning. 99.8% efficiency. Also for large hoods or downdraft tables. Statiflex 6000-MS Specifications Maximum Inlet Outlet Filter Dimensions Airflow Size Size Area (H x W x L) lbs. (kg) Statiflex 6000-MS 3,750 CFM 16 in. 16 in. 1,400 ft 2 115 x 48 x 48 in. 550 lbs. Filter Unit (6,400 m3/hr) (400mm) (400mm) (130 m 2 ) (2900 x 1200 x 2900 mm) (250kg) Pre-separator for Sparks and 24 in. 16 in. 99 x 24 x 30 in. 108 lbs. Large Particles (Required) N/A (600mm) (400mm) N/A (2500 x 600 x 750 mm) (49kg) 19

LINCOLN ENVIRONMENTAL SYSTEMS OFFERS A FULL LINE OF EXTRACTION PRODUCTS: The Lincoln Electric Company provides a variety of environmental solutions for welding applications ranging from simple single arc maintenance welding to highly complex multiple arc welding lines. Solutions may be in the form of either low vacuum systems as detailed in this bulletin (E13.40) or high vacuum systems as outlined in product bulletin E13.10. High vacuum systems are designed to move less air per collection device than the low vacuum systems. This feature often makes the high vacuum design the most efficient choice for dedicated welding applications where the fume suction device can be placed in close proximity to the welding arc. Likewise, low vacuum systems are often the best choice when close proximity cannot be maintained. Contact your local Lincoln representative for more details. They will gladly assist you in determining the best solution to meet your needs and expectations. Suction Heads HIGH VACUUM OPTIONS: Fume Extraction Guns Central Systems for Total Plant Coverage X-TRACTOR 1GC K652-1 (120V) K652-2 (230V) Lightweight, single suction head or fume gun system. Efficient polyester filter with a unique cleaning system. X-TRACTOR 4G K1613-1 (460V) K1613-2 (230V) Heavy duty system for four fume guns or two to three suction heads. Automatic filter cleaning cycle is programmable. THE LINCOLN ELECTRIC COMPANY Local Sales and Service through Global Subsidiaries and Distributors Cleveland, Ohio 44117-1199 U.S.A TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com Environmental Systems E13.40 11/99 Customer Assistance Policy The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for advice or information about their use of our products. We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer s particular purpose, with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products. Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these type of fabrication methods and service requirements.