INSTALLATION, OPERATION & MAINTENANCE MANUAL BYPASS ECONOMIZER OPTION

Similar documents
The newest addition to RenewAire s broad line of Energy Recovery Ventilators.

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

ECONOMIZERS. 5/2012 Supersedes

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

Safety & Installation Instructions

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

Installation Instructions

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

FOR USE IN SOLUTION AIR HANDLING UNITS

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

ECONOMIZERS. 1/2012 Supersedes

INSTALLATION INSTRUCTIONS

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

Installing Power Components

Installation Instructions DNECOMZR020A02, DNECOMZR021A03 (For 3 to 12.5 Ton Units) and DNECOMZR062A00 (For RHS 12.5 Ton Heat Pump Units)

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Installation Instructions

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Installation Instructions

Sequence of Operation. Installation. Commissioning. Testing and replacement of dampers and actuators. Troubleshooting. Maintenance

Installation Instructions

SECTION CONTROL DAMPERS

Installation Instructions

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

Installation Instructions

Fan Powered Low Profile Variable Volume Terminal Units

Installation Instructions

Installation Instructions

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

Installation Instructions

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Instruction Manual. Q Series 2 Motor Control Modules - OEM

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Metasys Zoning Package Installation

Model 8144NC Fresh Air Ventilator

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

INSTALLATION INSTRUCTIONS ECOHLX Series Horizontal Economizer and PEHALX Series Economizer with Power Exhaust for York LX Series. Warning.

Installation Instructions

Package Unit Modulating Economizer Installation Instructions

Metasys Zoning Package Overview

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

Installation, Operation and Maintenance Manual

Air Quality Solutions

Installation Instructions

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

SLIMZONE CLASSIC /

LE MODELS: SHIPPING, RIGGING, LIFTING, ASSEMBLY MANUAL

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS


INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

Installation, Operation & Maintenance Manual ENERGY RECOVERY VENTILATOR HE1.5XIN

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

XS400 Load Bank. Read all instructions before using the load bank. Contents

INSTALLATION AND OPERATION MANUAL

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

Installation Instructions

MicroTech III Water Source Heat Pump Wall-Mounted Room Temperature Sensors

Installation Instructions

READ AND SAVE THESE INSTRUCTIONS

ACCUVALVE MODEL AVT6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVT6000 AVT6 - - DWG. NO: REVISION: REV. DATE:

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

SPECIFICATION SHEET. C5000 ( cfm)

Installation, Operation and Maintenance Manual

Installation Instructions

ACCUSTATION SUBMITTAL MATERIALS

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Package Unit Modulating Economizer Installation Instructions

INSTALLATION/OPERATING INSTRUCTIONS TSC

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Volume Flow Limiters Type VFL

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

KENCO ENGINEERING COMPANY

IMPORTANT ATTENTION INSTALLERS:

INFINITY ZONING QUICK START GUIDE

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Variable Air Volume Dampers

Installation, Operation and Maintenance Instructions. ERV1500e ERV2000e ERV3000e

SECTION AIR TERMINAL UNITS

Differential Pressure Transmitter

General Description. Product Specification. Document Digital Temperature Interlock

First Correlating Revision No. 1-NFPA [ Section No ]

Laboratory Exhaust Air Terminal

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

BOOK 4 ELECTRICAL RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 4:

Fan Coil Unit (FCU) Fan Motor Control

Transcription:

INSTALLATION, OPETION & MAINTENANCE MANUAL Bypass Economizer Option for: HE1XIN, HE1.5XIN, HE2XIN, HE3XIN, HE4XIN, HE6XIN, HE8XIN WWW.RENEWAIRE.COM

IMPORTANT SAFETY INFORMATION WARNING Arc flash and electric shock hazard. Disconnect all electric power supplies and wear protective equipment per NFPA 70E before working within electric enclosure. Lock and tag the disconnect switch or breaker to prevent accidental re-connection of electric power while performing service or maintenance operations. Failure to comply can cause serious injury or death. Customer must provide earth ground to unit, per NEC, CEC and local codes, as applicable. Before proceeding with installation, read all instructions, verify that all parts are included and check the nameplate to verify the voltage matches available utility power. The line side of the disconnect switch on the front of the unit contains live high-voltage. The only way to ensure there is NO voltage inside the unit is to install and open all local and remote disconnect switches and then verify that power is off with a voltmeter. Refer to unit electrical schematic. Follow all local codes. CAUTION Risk of damage to the enthalpic core. Improper maintenance procedures may lead to damage of the enthalpic core. When performing maintenance of the or the core bypass, organic solvents are not to be used within the enclosure. In addition, high pressure air is not to be applied to the enthalpic core. Risk of damage to the Core Bypass controls. CAUTION Whenever a control device is connected to or disconnected from the controls circuits, the power supply to the must be disconnected. Lock and tag the disconnect switch or circuit breaker to prevent accidental reconnection of electric power. IMPORTANT This equipment is only for use in completed structures. Use of this equipment prior to completion of building construction will void the warranty. Do not use this equipment for temporary conditioning of the air. IMPORTANT This equipment is to be installed by following Industry Best Practices and all applicable codes. Any damage to components, assemblies, subassemblies or the cabinet which is caused by improper installation practices will void the warranty. 2 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION 2 TABLE OF CONTENTS 3 TABLE OF WIRING SCHEMATICS 4 TABLE OF ILLUSTTIONS 4 UNIT RECORDS 5 1.0 OVIEW 7 1.1 Dry Bulb Control 7 1.2 Enthalpy Control 7 1.3 s 7 2.0 RENEWAIRE OPTION CODE 9 3.0 LAYOUT RECOMMENDATIONS 10 4.0 PERFORMANCE DATA 12 5.0 COMPONENT TECHNICAL DATA 14 5.1 Dry Bulb Controller 14 5.2 Thermistor 14 5.3 Enthalpy Dry Bulb Controller 15 5.4 Outdoor Air Enthalpy Controller 15 5.5 Return Air Enthalpy Transmitter 15 5.6 Round 16 5.7 Rectangular 16 5.8 Belimo Actuator 17 5.9 Belimo FSLF-24S 17 5.10 Ruskin RUS-S24-S Acutator 5.11 Dry Bulb Control Wiring Schematic 18 5.12 Enthalpy Control Wiring Schematic 19 5.13 Model HE1XIN Dimension Drawings 20 5.14 Model HE1.5XIN Dimension Drawings 22 5.15 Model HE2XIN Dimension Drawings 24 5.16 Model HE3XIN Dimension Drawings 26 5.17 Model HE4XIN Dimension Drawings 28 5.18 Model HE6XIN Dimension Drawings 30 5.19 Model HE8XIN Dimension Drawings 31 6.0 INSTALLATION 32 7.0 UNIT START-UP DAMPER ADJUSTMENT 34 7.1 Tools Required for Adjustment 34 7.2 Adjustment Procedure 34 8.0 UNIT START-UP CONTROLS ADJUSTMENT 35 8.1 Dry Bulb Control Settings 35 8.2 Enthalpy Control Settings 35 9.0 UNIT MAINTENANCE 36 10.0 TROUBLESHOOTING 37 10.1 Sequence of Operation (SOO) 37 11.0 FACTORY ASSISTANCE 39 12.0 WARNTY 39 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 3

TABLE OF WIRING SCHEMATICS Dry Bulb Controller Partial Wiring Schematic 14 Enthalpy Controller Partial Wiring Schematic 15 Dry Bulb Control Wiring Schematic 18 Enthalpy Control Wiring Schematic 19 TABLE OF ILLUSTTIONS Typical Dry Bulb Controller 5 Typical Enthalpy Controller 6 Dry Bulb Controller 7 Return Air Enthalpy Transmitter 7 Outdoor Air Enthalpy Controller 7 Typical With Core Bypass 8 Typical Without Core Bypass 8 RenewAire Option Code 9 HE1XINH Duct Layout 10 HE1.5XINH Duct Layout 10 HE2XINH Duct Layout 11 HE3XINV Duct Layout 11 HE6XIN & HE8XIN Duct Layout 11 Psychometric Chart (Dry Bulb Control) 12 Psychometric Chart (Enthalpy Control) 13 Dual Dry Bulb Controller 14 Typical Thermistor 14 Enthalpy Dry Bulb Controller 15 Outdoor Air Enthalpy Controller 15 Return Air Enthalpy Transmitter 15 Chart of Actuators by RenewAire Model 17 HE1XINH Dimension Drawings (Horizontal Airflow Orientation) 20 HE1XINV Dimension Drawings (Vertical Airflow Orientation) 21 HE1.5XINV Dimension Drawings (Horizontal Airflow Orientation) 22 HE1.5XINV Dimension Drawings (Vertical Airflow Orientation) 23 HE2XINH Dimension Drawings (Horizontal Airflow Orientation) 24 HE2XINV Dimension Drawings (Vertical Airflow Orientation) 25 HE3XINH Dimension Drawings (Horizontal Airflow Orientation) 26 HE3XINV Dimension Drawings (Vertical Airflow Orientation) 27 HE4XINH Dimension Drawings (Horizontal Airflow Orientation) 28 HE4XINV Dimension Drawings (Vertical Airflow Orientation) 29 HE6XIN Dimension Drawings 30 HE8XIN Dimension Drawings 31 Table of Installed Features by Model 32 Typical Actuator Stop Adjustment 34 Dry Bulb Controller 35 Enthalpy Controller 35 Core Bypass Sequence of Operations (SOO) 37 4 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

UNIT RECORDS UNIT RECORDS Record information as shown below. A permanent record should be maintained so that damper stop and controls settings can be verified at a later date. In the unlikely event that factory assistance is ever required, this information will also be needed. Locate the RenewAire unit label, to be found on either the left or right side of the unit. Record the following: Option Code: NOTE: this page and the following page are to be completed by the installing contractor. The completed document is to be turned over to the owner after start-up. Model: Serial Number Option Code Model Serial Number Type of Bypass Controls: (check one) Typical Unit Label (found on either left side or right side of the unit) Dry Bulb Enthalpic If controls are dry bulb, record the following: Low Limit (setting at time of start-up) (Low Limit Factory Setting: 53 0 ) Show any changes to Low Limit setting (include date and reason for change) High Limit (setting at time of start-up) Show any changes to High Limit setting (include date and reason for change) (High Limit Factory Setting: 75 0 ) Typical Dry Bulb Controller (low limit on left, high limit on right) 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 5

UNIT RECORDS If controls are enthalpic, record the following: Low Limit (setting at time of start-up) (Low Limit Factory Setting: 53 0 ) Show any changes to Low Limit setting (include date and reason for change) Typical Enthalpy Controller 6 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

OVIEW 1.0 OVIEW The Bypass Economizer Option is a system that provides energy conservation during operation of an. It accomplishes this by sensing ambient conditions and it then allows the air stream to move through an alternate duct, bypassing the enthalpic core. This avoids unnecessary tempering of Supply Air. The Bypass Economizer Option consists of one extra duct, two electrically actuated dampers and a control system. The bypass duct is field-supplied, fabricated and installed. See illustrations on page 8. There are two variations of the control system, one of which uses a single outdoor air dry bulb controller and sensor and the second variation uses a Return Air enthalpy sensor in conjunction with an OA enthalpy controller and a dry bulb temperature controller. 1.1 Dry Bulb Control 1.1 DRY BULB CONTROL The first control scheme has one thermistor to sense outdoor air temperature. The controller itself has two user-adjusted setting dials. The adjustable Low Limit setting is the temperature below which the will operate without the core bypass (normal operation). The adjustable High Limit setting is the temperature above which the will again go into normal operation without bypassing the core. In other words, there is a temperature band when the bypass should be actuated and these two settings determine the upper and lower limits of that temperature band. 1.2 Enthalpy Control 1.2 ENTHALPY CONTROL The second control scheme incorporates a more sophisticated level of bypass control. In addition to the dry bulb controller, the Core Bypass controller measures enthalpy in both the outdoor air and the return air streams to provide a more precise means of determining the upper and lower limit shutoff points. See Section 8.0 for detailed controls information. NOTE: The default condition of the core bypass is OFF. When ambient conditions fall within the user-applied presets, the dampers will actuate and cause the stream to be diverted through the bypass duct. Dry Bulb Controller 1.3 s 1.3 DAMPERS s are used to move the air stream through the bypass duct instead of through the enthalpic core (bypass ON) and also to return the air stream to normal operation (bypass OFF). They are also used to balance the air stream during bypass operation by means of setting the stops on the actuators. Return Air Enthalpy Transmitter Outdoor Air Enthalpy Controller 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 7

OVIEW Typical Without Core Bypass Typical With Core Bypass 8 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

CONFIGUTIONS 2.0 RENEWAIRE OPTION CODE There are seven different models of RenewAire s that can be ordered with the Bypass Economizer Option. Every has a unit label that shows the exact model with its options, as ordered. In the Option Code, units with the bypass economizer option will have a number in place of a letter for character 18. The individual number indicates which type of bypass controls are installed and whether any isolation dampers are installed. See Page 5 for instructions on how to locate the Option Code on the unit label. MODEL NUMBER HE - 2 X J I NH - S1 1UU - - 1 ANT - - - L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Digit 18: Flow Control* "-" = No Isolation s (with no Bypass) "D" = Motorized both Airstreams (with no Bypass) "E" = Motorized EA or Airstream (with no Bypass) "F" = Motorized FA or OA Airstream (with no Bypass) "0" = Drybulb Bypass s only (no Isolation s) "1" = Drybulb Bypass with Motorized s all Airstreams "4" = Drybulb Bypass with Motorized OA Airstream "5" = Enthalpy Bypass s only (no Isolation s) "6" = Enthalpy Bypass with Motorized s all Airstreams "9" = Enthalpy Bypass witih Motorized OA Airstream Restrictions: Face damper also acts as Isolation damper in EA or Airstream. Bypass not available in EV450. Bypass only available in indoor units. RenewAire Option Code 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 9

LAYOUT RECOMMENDATIONS 3.0 LAYOUT RECOMMENDATIONS HE1XINH SUGGESTED DUCT LAYOUT - FRONT same parts for HE1XINV HE1XINH SUGGESTED DUCT LAYOUT - BACK same parts for HE1XINV HE1INH Duct Layout HE1.5XINH SUGGESTED DUCT LAYOUT - FRONT same parts for HE1.5XINV HE1.5XINH SUGGESTED DUCT LAYOUT - BACK same parts for HE1.5XINV NOTE: All duct installations must conform to SMACNA guidelines. HE1.5INH Duct Layout NOTE: All duct layouts depicted in this manual are suggested and may be modified to accommodate field conditions. 10 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

LAYOUT RECOMMENDATIONS HE2XINH SUGGESTED DUCT LAYOUT - FRONT routing same for HE3XINH and HE4XINH (duct size changes) HE2XINH SUGGESTED DUCT LAYOUT - BACK routing same for HE3XINH and HE4XINH (duct size changes) HE2XINH Duct Layout HE3XINV SUGGESTED DUCT LAYOUT - FRONT routing same for HE2XINV, HE4XINV (duct size changes) HE3XINV SUGGESTED DUCT LAYOUT - BACK routing same for HE2XINV, HE4XINV HE3XINV Duct Layout HE6XIN & HE8XIN SUGGESTED DUCT LAYOUT - FRONT HE6XIN & HE8XIN SUGGESTED DUCT LAYOUT - BACK HE6XIN & HE8XIN Duct Layout 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 11

PERFORMANCE DATA 4.0 PERFORMANCE DATA 5 4 4 3 HUMIDITY TIO - GINS OF MOISTURE PER POUND OF DRY AIR 45 50 160 150 PSYCHROMETRIC CHART Normal Temperature I-P Units SEA LEVEL BAROMETRIC PRESSURE: 29.921 in. HG HIGH LIMIT 140 130 120 110 100 90 80 90% 70 80% LOW LIMIT 60 70% 50 60% 40 50% 25% 40% 30 20 8% RELATIVE HUMIDITY 30% 15% 6% 20% 4% 10 10% RELATIVE HUMIDITY 2% -20-15 -10-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 Chart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com DRY BULB TEMPETURE - F Psychometric Chart (Dry Bulb Control) 12 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

PERFORMANCE DATA 50 45 40 35 30 HUMIDITY TIO - GINS OF MOISTURE PER POUND OF DRY AIR ENTHALPY - BTU PER POUND OF DRY AIR 45 50 160 150 PSYCHROMETRIC CHART Normal Temperature I-P Units SEA LEVEL BAROMETRIC PRESSURE: 29.921 in. HG HIGH LIMIT 140 130 120 110 100 90 80 90% 70 80% LOW LIMIT 60 70% 50 60% 40 50% 25% 40% 30 20 8% RELATIVE HUMIDITY 30% 15% 6% 20% 4% 10 10% RELATIVE HUMIDITY 2% -20-15 -10-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 Chart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com DRY BULB TEMPETURE - F 0 5 10 15 20 25 Psychometric Chart (Enthalpy Control) 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 13

COMMON TECHNICAL DATA 5.0 COMPONENT TECHNICAL DATA 5.1 Dry Bulb Controllerr 5.1 DRY BULB CONTROLLER The Dry Bulb Controller is the simpler of the two control options. It is connected to a thermistor that senses the ambient temperature. There are two user-adjusted controls on the dry bulb controller, one for Low Limit Set Point and a second for High Limit Set Point. When the temperature sensed by the thermistor is greater than the Low Limit Set Point, it activates the bypass function. If the temperature drops below the Low Limit Set Point, the bypass function will switch OFF. If the temperature rises above the High Limit Set Point, the bypass function will again switch OFF. Dual Dry Bulb Controller The temperature band that falls between the Low Limit Set Point and the High Limit Set Point is the only time that the bypass function is switched ON. THERMISTOR 2,252 OHMS @ 25 C THERMISTOR 24 VAC LOW LIMIT SETPOINT F P1 HIGH LIMIT SETPOINT F P2 K1 MODEL NR: NGE: LINE VOLTAGE: BA32X6-95 41 TO 95 F 24 VAC LOAD VAC TYPICAL LOAD CONNECTION 5.2 Thermistor Dry Bulb Controller Partial Wiring Schematic 5.2 THERMISTOR The thermistor is used with all control schemes. It is factory-installed in the Energy Recovery Ventilator and operates on 24 VAC. Typical Thermistor 14 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

TECHNICAL DATA 5.3 Enthalpy Dry Bulb Controller 5.3 ENTHALPY DRY BULB CONTROLLER The enthalpy dry bulb controller is the device where the user sets the low limit setpoint. It is connected to both a thermistor and to the Outdoor Enthalpy Controller. 5.4 Outdoor Air Enthalpy Controller 5.4 OUTDOOR AIR ENTHALPY CONTROLLER The outdoor air enthalpy controller is connected to both the dry bulb controller and the Enthalpy Transmitter. The outdoor air enthalpy controller compares its enthalpy reading to that of the return air enthalpy transmitter. If the outdoor air enthalpy is less than the return air enthalpy, and the outdoor air temperature is greater than the low limit setpoint, the bypass function will switch ON. 5.5 Return Air Enthalpy Transmitter 5.5 RETURN AIR ENTHALPY TNSMITTER The return air enthalpy transmitter is used in conjunction with the Outdoor Air Enthalpy Controller. The controller takes enthalpy readings from the transmitter to establish if ambient conditions fall within the user-defined setpoints to activate or deactivate the bypass. See Section 8.2 for more details. Enthalpy Dry Bulb Controller LOW LIMIT DRY BULB CONTROLLER 24 VAC TO DAMPERS Outdoor Air Enthalpy Controller P2 F 24 VAC LOW LIMIT SETPOINT THERMISTOR Return Air Enthalpy Transmitter ENTHALPY CONTROLLER (has built-in enthalpy sensor) ENTHALPY TNSMITTER (has built-in enthalpy sensor) SLIDE SWITCH (always set to "A") Enthalpy Controller Partial Wiring Schematic 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 15

TECHNICAL DATA NOTE: All duct installations must conform to SMACNA guidelines. 5.6 Round 5.6 ROUND DAMPER Round dampers are typically used in field-supplied and installed 12 round bypass ductwork. They are also used as face dampers for HE1XIN units. When the damper is shipped loose for field installation, the damper actuator is pre-assembled to the damper. Whenever a round damper is used, it operates in conjunction with a Belimo LF24-S Actuator (if bypass damper) or Ruskin RUS-S24-S (if face damper). See chart of Actuators on page 17. 5.7 Rectangular 5.7 RECTANGULAR DAMPER Rectangular dampers are typically used as either face dampers or bypass dampers, depending on the field-supplied and installed bypass ductwork. Rectangular bypass dampers are always used in conjunction with Belimo Actuators and rectangular face dampers are used in conjunction with Ruskin Actuators, except for HE6XIN and HE8XIN units. See chart of Actuators on page 17. 16 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

TECHNICAL DATA 5.8 Belimo Actuator 5.8 BELIMO TFB24-S DAMPER ACTUATOR The Belimo TFB24-S actuators are used for all rectangular bypass dampers. For further information on this specific damper actuator, see the manufacturer s website: https://www.belimo.us/shop/en_us/actuators/-actuators-%28fail-safe%29/tfb24-s/p?code=tfb24-s 5.9 Belimo FSLF-24S 5.9 BELIMO LF-24S DAMPER ACTUATOR The larger Belimo LF24-S damper actuators are typically used in 12 round bypass damper and for the 26 X 38 face dampers on the HE6XIN and HE8XIN s. For further information on this specific damper, see the manufacturer s website: https://www.belimo.us/shop/en_us/actuators/-actuators-%28fail-safe%29/lf24-us/p?code=lf24+us 5.9 Belimo FSLF-24S 5.10 RUSKIN RUS-S24-S DAMPER ACTUATOR The Ruskin RUS-S24-S damper actuators are used for most rectangular face dampers, and the 12 round face damper. For further information on this specific damper, see the manufacturer s website: https://www.ruskin.com/model/rus-s24-s RenewAire Model Face Actuator Bypass Actuator HE1XIN RUS-S24-S LF24-S HE1.5IN RUS-S24-S LF24-S HE2XIN RUS-S24-S TFB24-S HE3XIN RUS-S24-S TFB24-S HE4XIN RUS-S24-S TFB24-S HE6XIN LF24-S TFB24-S HE8XIN LF24-S TFB24-S Chart of Actuators by RenewAire Model NOTE: All bypass damper actuators have a built-in adjustable stop that is used for balancing air flow. See Section 7.0 of this manual for instructions on balancing the air flow at time of start-up. 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 17

1 2 1 2 TECHNICAL DATA 5.10 Dry Bulb Control Wiring Schematic 5.11 DRY BULB CONTROL WIRING SCHEMATIC Dry bulb control is comprised of two dampers and their actuators, a dry bulb controller and a thermistor. The only user adjustments that are made to this system during normal operation are the LOW and HIGH settings on the controller.. U1 V1 W1 U2 V2 W2 PE Exhaust VFD SHLD AI1 GND +10 VDC OUT AIN 2 GND 1 2 3 4 5 6 7 AO 8 GND 9 +24 VDC 10 GND 11 DCOM 12 DIN1 13 DIN2 14 DIN3 15 DIN4 16 DIN5 S3 Bypass DAMPER S1 S3 Face/Bypass Relay Face DAMPER S1 4 8 12 24 VAC 13 14 U1 V1 W1 U2 V2 W2 PE Supply VFD SHLD AI1 GND +10 VDC OUT AIN 2 GND 1 2 3 4 5 6 7 AO 8 GND 9 +24 VDC 10 GND 11 DCOM 12 DIN1 13 DIN2 14 DIN3 15 DIN4 16 DIN5 Supply Relay 4 12 8 24 VAC 13 14 Exhaust Relay 4 12 8 24 VAC 13 14 Dry Bulb Controller - 24V + SENS N.O. C Thermistor (OA Airstream) 1 2 3 4 5 Dry Bulb Control Wiring Schematic 18 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

1 2 1 2 TECHNICAL DATA 5.11 Enthalpy Control Wiring Schematic 5.12 ENTHALPY CONTROL WIRING SCHEMATIC Enthalpy control is comprised of two dampers and their actuators, an enthalpy transmitter that contains a thermistor, an enthalpy controller that receives data from the enthalpy transmitter, and an enthalpy dry bulb controller. The only user adjustment that may be made to this system during normal use is the LOW LIMIT setpoint on the dry bulb controller.. Bypass DAMPER Face DAMPER S1 S3 S1 S3 Face/Bypass Relay 4 8 12 24 VAC Low Limit Dry Bulb Controller - 24V + NC NO C 13 14 SENS F Supply Relay 4 12 8 Exhaust Relay 4 12 8 Thermistor (OA Airstream) GND 24 4-20 Vout VAC IN Vin 4-20mA Out 24 VAC 24 VAC 13 14 13 14 SENS SENS Differential Enthalpy Controller (OA Airstream) Enthalpy Transmitter ( Airstream) 1 2 3 4 5 Enthalpy Control Wiring Schematic 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 19

TECHNICAL DATA 5.12 Model HE1XIN Dimension Drawings 5.13 MODEL HE1XIN DIMENSION DWINGS 21 3/4" Case 29" EA FA OA BYPASS AIRFLOW SCHEMATIC FRONT VIEW -interlocked Disconnect Switch 2 7/8" Typ. 49 1/8" Case Pressure Ports (4) Typ. OA Isolation Wiring Conn. EA OA 3/4" - 1 7/8" Typ. 34 7/8" Case 8 7/8" 27 1/2" 38 3/8" Overall 49" Minimum (s can be Removed from Hinges.) Bypass 12" Round Bypass Duct Connection (Direct Mount to, By Others) Face ABBREVIATIONS EA: Exhaust Air to Outside OA: Outside Air Intake : Room Air to be Exhausted FA: Fresh Air to Inside : Bypass Air Intake INSTALLATION ORIENTATION Unit may be installed in any orientation. NOTE 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. TOP VIEW Alternate Power Wiring Inlet 7/8" 20 1/8" Minimum (s can be Removed from Hinges.) 12" TYP. ISOMETRIC VIEW 6" TYP. FRONT VIEW RIGHT VIEW (OA//) DAMPER OPTION (QTY.3) (SHIPPED LOOSE) SCALE 1:18 9" TYP. 3. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 4. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. 5. DAMPERS SHIPPED LOOSE, FIELD INSTALLATION REQUIRED 23 3/4" Overall Control Wiring Inlet 1 1/8" 10 3/8" Power Wiring Inlet 7/8" FA Face/Isolation Wiring Conn. 12" Typ. Leveling Feet (4) Conn. Location 12" Bypass (Not Shown) LEFT VIEW FRONT VIEW RIGHT VIEW 10 3/8" 54 3/4" Overall 7 5/8" 8 1/8" Alternate Control Wiring Inlet 7/8" HE1XINH Dimension Drawings (Horizontal Airflow Orientation) 12 7/8" 8 7/8" 27 5/8" 8 5/8" 20 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

TECHNICAL DATA 26 1/2" Overall ABBREVIATIONS EA: Exhaust Air to Outside OA: Outside Air Intake : Room Air to be Exhausted FA: Fresh Air to Inside : Bypass Air Intake EA BYPASS AIRFLOW SCHEMATIC TOP VIEW (OA/FA Airstream Not Shown) 10 3/8" Typ. 12" Typ. Pressure Ports (4) Typ. 34 7/8" Case Bypass Location 2 7/8" Typ. 20 1/8" Minimum (s can be Removed from Hinges.) 29" 21 3/4" Case 3/4" - 1 7/8" Typ. 49 1/8" Case 49" Minimum (s can be Removed from Hinges.) FA -Interlocked Disconnect Switch Leveling Feet (4) FRONT VIEW EA 16 1/4" Typ. 40 3/4" Typ. 50 3/4" Overall 9 3/4" 40 3/8" Overall 27 5/8" TOP VIEW 12" TYP. FRONT VIEW ISOMETRIC VIEW 6" TYP. RIGHT VIEW 9" TYP. (OA//) DAMPER OPTION (QTY.3) (SHIPPED LOOSE) SCALE 1:18 12" Round Bypass Duct Connection (Direct Mount to, By Others) Face Bypass INSTALLATION ORIENTATION Unit may be installed in any orientation. NOTE 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 3. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 4. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. 5. DAMPERS SHIPPED LOOSE, FIELD INSTALLATION REQUIRED Face/Isolation Wiring Conn. Conn. Location 12" Bypass (Not Shown) 12 7/8" LEFT VIEW Power and Control Wiring Inlets 7/8" OA OA Isolation Wiring Conn. 8 5/8" RIGHT VIEW HE1XINV Dimension Drawings (Vertical Airflow Orientation) 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 21

TECHNICAL DATA 5.13 Model HE1.5XIN Dimension Drawings 5.14 MODEL HE1.5XIN DIMENSION DWINGS EA 5" Frames Typ. 3 1/4" 6 1/4" Typ. 48 3/4" Overall Pressure Ports (4) Typ. EA OA 12" Bypass Location FA -interlocked Disconnect Switch 1 1/4" Duct Receiving Flange Typ. FRONT VIEW 52 3/4" Case 6" 32" 6" 10 5/8" 32" 53 5/8" Overall 16" X 14" Isolation (Optional) Acts as Face for Bypass Units FA Location (Optional) Power Wiring Inlet 7/8" dia. Control Wiring Inlet 7/8" dia. Plug Location 12" Bypass (Not Shown) LEFT VIEW 18" X 18" Duct Receiving Flange Typ. 24 1/2" 20 1/8" Minimum (s can be Removed from Hinges.) 6 3/8" Typ. RIGHT VIEW 36 3/8" Overall 31 7/8" Case 49 3/8" Minimum 12" Round Bypass Duct Connection (Direct Mount to, By Others) Face Bypass BYPASS AIRFLOW SCHEMATIC TOP VIEW (OA/FA Airstream Not Shown) 42 5/8" Case 1 1/4" 13 7/8" TOP VIEW ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake : Room Air to be exhausted FA: Fresh Air to inside : Bypass Air outlet INSTALLATION ORIENTATION Unit may be installed in any orientation. NOTE 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 3. MIN. DUCT CLEANCE FROM DAMPER BLADE WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. 4. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 5. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. HE1.5XINH Dimension Drawings (Horizontal Airflow Orientation) 22 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

TECHNICAL DATA 2 7/8" OA FA EA BYPASS AIRFLOW SCHEMATIC FRONT VIEW FA 59 1/2" Overall 1 1/4" Pressure Ports (4) Typ. FRONT VIEW OA EA 5" Frames Typ. -Interlocked Disconnect Switch 48 1/2" Overall 45 3/4" Case 4 1/4" 24 5/8" 3 1/4" 6 1/4" Typ. 18" X 18" Duct Receiving Flange Typ. LEFT VIEW 6 1/4" Typ. 4 1/4" 24 5/8" 49 5/8" Case 11 5/8" 12" 16" X 14" Isolation (Optional) Acts as Face for Bypass Units Power Wiring Inlet 7/8" Control Wiring Inlet 7/8" 6 1/4" RIGHT VIEW 20 1/8" Minimum (s can be Removed from Hinges.) 15 1/4" 24 1/2" 31 7/8" Case 34 1/2" Overall 12" Round Bypass Duct Connection (Direct Mount to, By Others) Bypass Face FA Location (Optional) Plug Location 12" Bypass (Not Shown) 49 1/2" Minimum TOP VIEW ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake : Room Air to be exhausted FA: Fresh Air to inside : Bypass Air outlet INSTALLATION ORIENTATION Unit may be installed in any orientation. NOTE 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. Patch Pan (Opening Used for Alternative Unit Configurations.) Typ. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 3. MIN. DUCT CLEANCE FROM DAMPER BLADE WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. 4. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 5. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. HE1.5XINV Dimension Drawings (Vertical Airflow Orientation) 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 23

TECHNICAL DATA 5.14 Model HE2XIN Dimension Drawings 5.15 MODEL HE2XIN DIMENSION DWINGS EA OA FA BYPASS AIRFLOW SCHEMATIC FRONT VIEW 9" Typ. 41 7/8" Overall 1 3/4" 34 3/4" Case 18 1/4" 8 1/2" Wiring 5" 3/4" - 1 7/8" Typ. 1 5/8" 19 3/8" 16" X 12" Duct Receiving Flange Typ. 4 1/4" Duct Flange Typ. E-Box EA FA C L 1/8" Wiring Disconnect Switch 20 1/2" 49 1/8" Case 64 3/8" Overall C L 5 3/4" Power In C L 2 5/8" Control In Pressure Taps (4) Typ. OA 5" Frames Typ. OA Inlet 24" X 14" Duct Receiving Flange OA Location (Optional) 8 1/4" Inlet 24" X 14" Duct Receiving Flange Isolation (Optional) Acts as Face for Bypass Units 42 7/8" Overall 41 1/2" Case 20 1/8" Minimum 9 7/8" 16" X 16" Bypass Duct Connection (Direct Mount to, By Others) 16" X 16" Bypass Location (Optional) Bypass Face LEFT VIEW Note: Lifts Away 59 3/8" Minimum TOP VIEW (2) 7/8" Holes for Wiring in Bottom of E-Box FRONT VIEW ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake : Room Air to be exhausted FA: Fresh Air to inside : Bypass Air Intake INSTALLATION ORIENTATION Unit must be installed in orientation shown. NOTE 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 3. MIN. DUCT CLEANCE FROM DAMPER BLADES WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. 4. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 5. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. RIGHT VIEW HE2XINH Dimension Drawings (Horizontal Airflow Orientation) 24 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

TECHNICAL DATA OA FA EA BYPASS AIRFLOW SCHEMATIC FRONT VIEW 51 1/2" Overall 33 5/8" Minimum 42" Overall 41 5/8" Case 34 7/8" Minimum 5" Frames Typ. 34 7/8" Case 4 1/4" Duct Flange Typ. OA E-Box FA EA Disconnect Switch C L 2 5/8" Control In C L 5 3/4" Power In Pressure Ports (4) Typ. OA Inlet 24" X 14" Duct Receiving Flange 8 1/4" OA Location (Optional) 3/4" - 1 7/8" Typ. 17 5/8" 1 3/4" Typ. 37" 16" X 16" Bypass Location (Optional) 10 3/8" 12 3/8" 52 3/8" Overall 51 5/8" Case 9 3/8" Wiring 37" Bypass Location 16" X 16" Bypass Duct Connection (Direct Mount to, By Others) Face Bypass Inlet 24" X 14" Duct Receiving Flange Isolation (Optional) Acts as Face for Bypass Units 8 1/4" 16" X 12" Duct Receiving Flange Typ. C L 5 3/8" Wiring LEFT VIEW TOP VIEW (2) 7/8" Holes for Wiring in Bottom of E-Box FRONT VIEW ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake : Room Air to be exhausted FA: Fresh Air to inside : Bypass Air Intake INSTALLATION ORIENTATION Unit must be installed in orientation shown. NOTE 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 3. MIN. DUCT CLEANCE FROM DAMPER BLADE WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. 4. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 5. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. RIGHT VIEW HE2XINV Dimension Drawings (Vertical Airflow Orientation) 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 25

TECHNICAL DATA 5.15 Model HE3XIN Dimension Drawings 5.16 MODEL HE3XIN DIMENSION DWINGS EA OA FA BYPASS AIRFLOW SCHEMATIC FRONT VIEW 47 3/8" Overall 41" Case 21 7/8" 5" 16" X 12" Duct Receiving Flange Typ. C L 5 3/8" Wiring 8 1/2" Typ. 10 3/8" 4 1/4" Duct Flange Typ. E-Box EA FA Disconnect Switch 18 1/2" 72 3/4" Overall 57 1/8" Case 54 1/2" Lifting Lugs OA OA Location (Optional) 63 1/8" Overall 59 3/8" Lifting Lugs 12 1/4" OA Inlet 36" X 14" Duct Receiving Flange 6" 24 7/8" C L 5 3/4" Power In C L 2 5/8" Control In Pressure Ports (4) Typ. Inlet 36" X 14" Duct Receiving Flange Isolation (Optional) Acts as Face For Bypass Units 62 1/4" Case 17 3/8" 30" X 16" Bypass Location (Optional) 5" Frames Typ. 33 3/4" Minimum 8 1/4" 65 5/8" Minimum TOP VIEW 2 1/8" 1 1/8" 30" X 16" Bypass Duct Connection (Direct Mount to, By Others) Bypass Face LEFT VIEW ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake : Room Air to be exhausted FA: Fresh Air to inside : Bypass Air Intake INSTALLATION ORIENTATION Unit must be installed in orientation shown. NOTE 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 3. MIN. DUCT CLEANCE FROM DAMPER BLADE WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. 4. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 5. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. (2) 7/8" Holes for Wiring in Bottom of E-Box FRONT VIEW RIGHT VIEW HE3XINH Dimension Drawings (Horizontal Airflow Orientation) 26 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

TECHNICAL DATA E-Box Disconnect Switch FA C L 5 3/4" Power In C L 2 5/8" Control In (2) 7/8" Holes for Wiring in Bottom of E-Box FRONT VIEW 5" Frames Typ. OA Pressure Ports (4) Typ. EA 4 1/4" Duct Flange Typ. 25 5/8" Wiring Location (Optional) 1 5/8" Typ. 36 5/8" Typ. C L 7 3/4" Wiring LEFT VIEW Inlet 36" X 14" Duct Receiving Flange OA Inlet 36" X 14" Duct Receiving Flange OA Location (Optional) 61 1/2" Overall 61 1/2" Case 16" X 12" Duct Receiving Flange Typ. RIGHT VIEW 46 5/8" Typ. 9 7/8" Typ. 50 3/4" Overall 35 1/4" Case 45 5/8" Minimum 4" 62" Overall 58" Case TOP VIEW 33 7/8" Minimum ABBREVIATION EA: Exhaust Air to outside OA: Outside Air intake : Room Air to be exhausted FA: Fresh Air to inside INSTALLATION ORIENTATION Unit must be installed in orientation shown. NOTE: 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 3. MIN. DUCT CLEANCE FROM DAMPER BLADES WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. HE3XINV Dimension Drawings (Vertical Airflow Orientation) 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 27

TECHNICAL DATA 5.16 Model HE4XIN Dimension Drawings 5.17 MODEL HE4XIN DIMENSION DWINGS EA OA FA BYPASS AIRFLOW SCHEMATIC FRONT VIEW 37 3/8" Typ. 34" X 12" Duct Receiving Flange Typ. C L 76" Wiring 4 1/2" 21 3/8" 41" Case 79 3/4" 10 1/4" EA FA 54 1/2" Lifting Lugs Pressure Ports (4) Typ. 47 3/8" Overall 5 7/8" 24 5/8" 82" Case 82 7/8" Overall 4 1/8" Duct Flange Typ. E-Box Disconnect Switch 72 3/4" Overall 57 3/8" Case 5 1/8" 5" Frames Typ. 48 7/8" 34" X 16" Bypass Location (Optional) 2 1/8" OA Location (Optional) 79 1/8" Lifting Lugs OA Inlet 42" X 14" Duct Receiving Flange 1 1/8" 67 3/8" Minimum TOP VIEW OA 56 7/8" C L 2 5/8" Control In C L 5 3/4" Power In Isolation (Optional) Acts as Face For Bypass Units Inlet 42" X 14" Duct Receiving Flange 19 1/8" Typ. 38 7/8" Minimum 34" X 16" Bypass Duct Connection (Direct Mount to, By Others) Bypass Face LEFT VIEW ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake : Room Air to be exhausted FA: Fresh Air to inside : Bypass Air Intake INSTALLATION ORIENTATION Unit must be installed in orientation shown. NOTE 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 3. MIN. DUCT CLEANCE FROM DAMPER BLADE WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. 4. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 5. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. FRONT VIEW (2) 7/8" Holes for wiring in bottom of E-Box RIGHT VIEW HE4XINH Dimension Drawings (Horizontal Airflow Orientation) 28 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

TECHNICAL DATA 1 5/8" 5" Frames Typ. E-Box Disconnect Switch FA OA FA EA BYPASS AIRFLOW SCHEMATIC FRONT VIEW Pressure Ports (4) Typ. OA EA C L 5 5/8" Power In C L 2 1/2" Control In (2) 7/8" Holes for Wiring in Bottom of E-Box FRONT VIEW 46 5/8" 10 1/8" Typ. 25 5/8" Wiring Isolation (Optional) Acts as Face For Bypass Units Inlet 42" X 14" Duct Receiving Flange Bypass Location 37 3/4" Typ. C L 8" Wiring LEFT VIEW OA Location (Optional) 81 7/8" Overall 81 1/2" Case OA Inlet 42" X 14" Duct Receiving Flange 1 5/8" 4" 28" 46 5/8" 58" Case 62" Overall 42" X 14" Bypass Location (Optional) 34" X 12" Duct Receiving Flange Typ. 5 1/4" RIGHT VIEW 5" Typ. 51 3/8" Overall 35 1/8" Case 5" Typ. 42 1/2" Minimum 34 1/8" Minimum TOP VIEW 42" X 14" Bypass Duct Connection (Direct Mount to, By Others) Face Bypass ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake : Room Air to be exhausted FA: Fresh Air to inside : Bypass Air Intake INSTALLATION ORIENTATION Unit must be installed in orientation shown. NOTE 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 3. MIN. DUCT CLEANCE FROM DAMPER BLADE WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. 4. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 5. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. HE4XINV Dimension Drawings (Vertical Airflow Orientation) 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 29

TECHNICAL DATA 5.17 Model HE6XIN Dimension Drawings 5.18 MODEL HE6XIN DIMENSION DWINGS ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake : Room Air to be exhausted FA: Fresh Air to inside : Bypass Air Intake OA INSTALLATION ORIENTATION Unit must be installed in orientation shown. NOTE 1.ALL UNITS HAVE INTERNAL EA BACKDFT DAMPER. UNLESS AN EA MOTORIZED ISOLATION DAMPER IS SPECIFIED. 16" X 38" Bypass Location Optional 116 3/4" Overall 112 5/8" Case 5 1/8" 2.UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. FA EA 3.SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 4. DAMPER SWINGS IN DIRECTION OF AIRFLOW. MIN. DUCT CLEANCE FROM DAMPER BLADE WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. 69 1/4" 32 3/8" 36" Power and Control Wiring Entries 7/8" Dia. INDOOR UNITS: EA BLOWER Outlet is 16" X 22" (Nom.) 24"X36" Duct Flange is also supplied. Field install only in location shown. 86 3/4" Overall 85 5/8" Case 6 3/8" Typ. 75 7/8" Lifting Lugs 2" 22" 53 1/2" 63 1/4" 81" 21 1/8" EA 108" Internal EA Motorized Location (Optional) BYPASS AIRFLOW SCHEMATIC RIGHT VIEW (OA/FA Airstream Not Shown) RIGHT VIEW 63 1/4" FRONT VIEW 2 1/4" 5" Typ. 4" 10 1/2" 78 1/4" Case 83 3/8" Overall FA Blower Outlet is 16" X 22" (Nom.) 24" X 36" Duct Flange is also supplied. Field install only in location shown. 102 7/8" Lifting Lugs Core Access Pressure Ports (4) Typ. 6 3/8" Typ. 26" X 38" Face Location Optional OA Duct Flange 24" X 36" LEFT VIEW 8 3/4" 48 3/4" Internal OA Location (Optional) BACK VIEW 34 3/4" Minimum 39 1/4" Minimum Service Area E-Box Minimum 85 5/8" Minimum 62" 34 3/4" Minimum Service Area 16" X 38" Bypass Duct Connection (Direct Mount to, By Others) TOP VIEW Bypass Face 5. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 6. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. HE6XIN Dimension Drawings 30 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

TECHNICAL DATA 5.18 Model HE8XIN Dimension Drawings 5.19 MODEL HE8XIN DIMENSION DWINGS ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake : Room Air to be exhausted FA: Fresh Air to inside : Bypass Air Intake OA INSTALLATION ORIENTATION Unit must be installed in orientation shown. NOTE 1.ALL UNITS HAVE INTERNAL EA BACKDFT DAMPER. UNLESS AN EA MOTORIZED ISOLATION DAMPER IS SPECIFIED. 16" X 38" Bypass Location Optional 116 3/4" Overall 112 5/8" Case 5 1/8" 2.UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. FA EA 3.SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 4. DAMPER SWINGS IN DIRECTION OF AIRFLOW. MIN. DUCT CLEANCE FROM DAMPER BLADE WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. 69 1/4" 32 3/8" 36" Power and Control Wiring Entries 7/8" Dia. INDOOR UNITS: EA BLOWER Outlet is 16" X 22" (Nom.) 24"X36" Duct Flange is also supplied. Field install only in location shown. 86 3/4" Overall 85 5/8" Case 6 3/8" Typ. 75 7/8" Lifting Lugs 2" 22" 53 1/2" 63 1/4" 81" 21 1/8" EA 108" Internal EA Motorized Location (Optional) BYPASS AIRFLOW SCHEMATIC RIGHT VIEW (OA/FA Airstream Not Shown) RIGHT VIEW 63 1/4" FRONT VIEW 2 1/4" 5" Typ. 4" 10 1/2" 78 1/4" Case 83 3/8" Overall FA Blower Outlet is 16" X 22" (Nom.) 24" X 36" Duct Flange is also supplied. Field install only in location shown. 102 7/8" Lifting Lugs Core Access Pressure Ports (4) Typ. 6 3/8" Typ. 26" X 38" Face Location Optional OA Duct Flange 24" X 36" LEFT VIEW 8 3/4" 48 3/4" Internal OA Location (Optional) BACK VIEW 34 3/4" Minimum 39 1/4" Minimum Service Area E-Box Minimum 85 5/8" Minimum 62" 34 3/4" Minimum Service Area 16" X 38" Bypass Duct Connection (Direct Mount to, By Others) TOP VIEW Bypass Face 5. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL SPACE FOR THE CONNECTION OF THE BYPASS DUCT (BY OTHERS). 6. FOR INSTALLATION DETAILS, REFER TO I&O MANUAL SUPPLEMENT FOR BYPASS. HE8XIN Dimension Drawings 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 31

INSTALLATION 6.0 INSTALLATION For every RenewAire Energy Recovery Ventilator with Bypass Economizer Option, controls and dampers are installed at the factory, with the exception of those components shown below. Bypass ductwork is always supplied, fabricated and installed by others, in the field. For further information on the needed bypass ductwork, see the technical data sheet for the specific model, found in this manual in Sections 5.11 through 5.18. In those cases where a damper(s) must be field-installed, the damper is labeled either FACE or BYPASS and is already assembled to its actuator. The damper and actuator are then field-installed and the actuator is plugged into the factory-installed wiring harness using the plug located outside the unit. RenewAire Model Controls Installed? Control Wiring Installed? Bypass Installed? Shipped Loose Face Installed? Shipped Loose Recommended Bypass Duct Size* HE1XIN Yes Yes 12" Round HE1.5IN Yes Yes Shipped Loose Yes 12" Round HE2XIN Yes Yes Yes Yes 16" X 16" HE3XINH Yes Yes Yes Yes 30" X 16" HE3XINV Yes Yes Yes Yes 36" X 14" HE4XINH Yes Yes Yes Yes 34" X 16" HE4XINV Yes Yes Yes Yes 42" X 14" HE6XIN Yes Yes Yes Yes 38" X 16" HE8XIN Yes Yes Yes Yes 38" X 16" *Recommended duct sizes are based on ensuring that the pressure drop in the bypass duct is less than the presssure drop through the core. Equivalent duct sizes at the same pressure drop are acceptable. Table of Installed Features by Model 1. Fabricate and install bypass ductwork in accordance with the guidelines shown for each model in this section of this manual. 2. Install dampers and damper actuators as required, shown on the chart above. 3. Balance the air flow through the bypass duct. See Section 7.0 of this manual. Adjust the damper actuator stops as needed. 4. Verify the settings on the dry bulb controllers. See Section 8.0 of this manual. 5. Complete the Unit Records on pages 5 and 6 of this manual. 32 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

INSTALLATION 6.1 Bypass Status Indicator Circuit THIS PAGE LEFT BLANK 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 33

START-UP Start-Up is defined as the process of activating each system within a newlyinstalled after it has been properly installed in the system in which it is expected to operate. A full and proper start-up cannot be performed unless the Occupied Space with all its associated ductwork, controls and design options are completed and intact and ready for full-load testing. 7.0 UNIT START-UP DAMPER ADJUSTMENT At time of unit start-up, it is required that the air streams be balanced to achieve maximum efficiency of the and the bypass system. Balancing of the air streams is accomplished by measuring air flow in the two air streams and then adjusting the damper stops. This procedure will ensure that the static pressure drop through the bypass airpath equals that of the energy recovery airpath, which will cause the ventilation flow rate to be the same in both energy recovery mode and free cooling mode. 7.1 Tools Required for Adjustment 7.1 TOOLS REQUIRED FOR DAMPER ADJUSTMENT Air velocity manometer or similar device. 7.2 Adjustment Procedure 7.2 DAMPER ADJUSTMENT PROCEDURE The bypass duct size is designed to allow more air than is needed in regular ventilation and is combined with a damper and an adjustable damper actuator to achieve balanced airflow. When the is in ventilation/recovery mode (not in bypass), use an air velocity manometer or similar device to determine the airflow CFM in both airstreams. Take note of the air flow in the to EA airstream. The airflow CFM in the to EA airstream during free cooling mode should match the airflow CFM during energy recovery. 1. Before starting the balancing procedure, confirm that the supply, exhaust, and bypass connections have been connected properly. 2. Make sure all power to the unit is off and all disconnect switches are in the off position. 3. In order to put the unit in free cooling mode manually, first disconnect the face and bypass damper actuators from the internal wire harness. 4. Connect each actuator to a known 24V power source with an appropriate cable. 5. Power on the unit and the bypass damper, allowing at least 60 seconds for the actuator to move to the proper position and the flow to stabilize. 6. Using an air velocity manometer or similar device, read the amount of airflow in the to EA airstream. 7. The actuator on the bypass damper has an adjustable stop that can be loosened and set so that the airflow (CFM) when in bypass is similar to the airflow (CFM) when in ventilation/recovery mode. a. If the airflow in recovery free cooling mode is too high, adjust the actuator so that the bypass damper opens to something less than 90 degrees (fully open). Repeat steps 5 and 6. When the desired flow rate is achieved move on to step 8. 8. Power down the unit and reconnect the damper actuators to the proper wire harnesses. Shaft Adjustable Stop (moves in slot on actuator body) Shaft Clamp Assy When Actuator Opens the, Shaft and Shaft Clamp Rotate Until the Ear on the Shaft Clamp Bumps Against the Adjustable Stop Movement of Shaft Clamp Assy is Stopped by the Adjustable Stop Actuator Stop Adjustment (shown in fully closed position) Typical Actuator Stop Adjustment 34 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

START-UP 8.0 UNIT START-UP CONTROLS ADJUSTMENT At time of unit start-up, the bypass controls must be checked for correct settings. The controls have been pre-set at the factory but they may become out of adjustment during shipping and handling. Remember that there are two different kinds of controls: dry bulb and enthalpy. Follow the settings information for the type of controls on the unit. 8.1 Dry Bulb Control Settings 8.1 DRY BULB CONTROL SETTINGS The dry bulb temperature controller features a thermistor placed in the outside air stream (internal to the unit) that senses the outside air temperature as it enters the unit. There are two dials on the dry bulb temperature controller to adjust both the high and low limits of the bypass range, and each dial has a range of 40 F to 95 F. Any time the outside air temperature rises through the temperature indicated on the high limit dial (labeled H ), the controller calls for energy recovery. Any time the outside air temperature falls through the temperature indicated on the low limit dial (labeled L ), the controller also calls for energy recovery. Any time the outside air temperature is above the low limit setpoint and below the high limit setpoint, the controller calls for bypass. Typical settings for the dry bulb temperature controller are 53 F for the low limit setpoint and a high limit setpoint that matches the desired room air temperature. (Note: It is possible to choose a low limit setpoint that is greater than the high limit setpoint for the dry bulb temperature controller. Doing so will result in a control scheme where there is no outside air temperature that will satisfy both setpoint conditions and cause the controller to call for bypass. 8.2 Enthalpy Control Settings 8.2 ENTHALPY CONTROL SETTINGS The differential enthalpy controller features two enthalpy sensors placed in the outside air and return air streams (internal to the unit), and a thermistor placed in the outside air stream (internal to the unit). There is one low limit temperature dial (labeled L ) on the controller with a range of -20 F to 120 F. The controller compares the outside air enthalpy to the room air enthalpy, and any time the outside air enthalpy rises above the room air enthalpy, the controller calls for energy recovery. Any time the outside air temperature falls through the low limit setpoint, the controller calls for energy recovery. Any time the outside air enthalpy is below the room air enthalpy and the outside air temperature is above the low limit setpoint, the controller calls for bypass. The typical setting for the low limit setpoint is 53 F. Note: To ensure proper operation, DO NOT choose a low limit setpoint that is greater than the high limit setpoint. Dry Bulb Controller Enthalpy Controller 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 35

MAINTENANCE 9.0 UNIT MAINTENANCE The most critical factor in maintaining the and Core Bypass is cleanliness. Experience on the part of the customer will dictate the frequency of maintenance activities. Air conditions can change seasonally or even day-by-day. Follow the maintenance instructions for the RenewAire, as found in the Installation, Operation and Maintenance Manual.. CAUTION Risk of damage to the enthalpic core. Improper maintenance procedures may lead to damage of the enthalpic core. When performing maintenance of the or the core bypass, organic solvents are not to be used within the enclosure. In addition, high pressure air is not to be applied to the enthalpic core. Risk of damage to the Core Bypass controls. CAUTION Whenever a control device is connected to or disconnected from the controls circuits, the power supply to the must be disconnected. Lock and tag the disconnect switch or circuit breaker to prevent accidental reconnection of electric power. 36 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

TROUBLESHOOTING 10.0 TROUBLESHOOTING Risk of damage to the Core Bypass controls. CAUTION Whenever a control device is connected to or disconnected from the controls circuits, the power supply to the must be disconnected. Lock and tag the disconnect switch or circuit breaker to prevent accidental reconnection of electric power. The most important resources for troubleshooting a suspected problem are the Sequence of Operation (SOO) and the wiring schematics. By referring to the SOO, it is possible to determine if an issue is a fault in the Core Bypass system or if the issue is a symptom of some other problem. Example: the and its Bypass Option may be controlled by a BMS that is not allowing the to go into free cooling mode. The symptom appears to be that the Core Bypass is not working, but the cause is actually the BMS. Using the SOO, identify the stage in the sequence where the issue appears. Identify the reason why the core bypass is thought to be an issue. Using the electrical wiring schematics, further isolate the problem to a single component. NOTE: There is no known pattern of failures with Core Bypass units. This section is provided as a guide for the user. NOTE: If a controls contractor was engaged to set-up the controls during installation of the, refer to that contractor s documentation regarding settings and connections. The SOO is found below and the electrical schematics are to be found in Section 5 of this document and the unit schematics located in the red envelope in the unit electrical box. 10.1 Sequence of Operation (SOO) 10.1 SEQUENCE OF OPETION (SOO) 1. Power is applied to the 2. The bypass controls draw power from the onboard 24V transformer and begin sensing the OA and (differential enthalpy only) conditions. 3. One of two things occurs: Energy recovery mode The sensors report to the controller that the should be in energy recovery mode and the controller supplies power to the face damper actuator. The face damper begins to power open, which may take up to 60 seconds. Powering on the OA blower will begin immediately if there are no isolation damper on that airstream, or will be delayed until the isolation damper has been opened. Powering on the EA blower will be delayed until the face damper has been opened. Recovery free cooling mode The sensors report to the controller that the should be in recovery free cooling mode and the controller immediately supplies power to the bypass damper actuator. The bypass damper begins to power open, which may take up to 60 seconds. Powering on the OA blower will begin immediately if there are no isolation damper on that airstream, or will be delayed until the isolation damper has opened. Powering on the EA blower will be delayed until the bypass damper has been opened. 4. If there is any significant distance between the OA inlet and the intake at the building wall, it may take some time for the outdoor air to reach the s sensors. Allow for the airflows to reach a steady state, during which time the unit could change modes. 5. When powering down the, the blowers will turn off and both the bypass and face dampers will return to their default positions. The bypass damper and the face damper will be closed. Any installed isolation dampers will also spring closed. Core Bypass Sequence of Operations (SOO) 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 37

FACTORY ASSISTANCE Case Mechanical Issues: Either the face damper or the bypass damper does not open when the enters free cooling mode or energy recovery mode. Steps to Identify Malfunctioning Component 1. Ensure that damper blades are not blocked or otherwise obstructed in the duct. 2. Ensure that the actuator has not come loose from the damper blade shaft. 3. Apply 24V power to the actuator to confirm that the actuator moves when it is powered, and spring returns when it is unpowered. Each damper should open when powered. Action If the damper blades are blocked, remove any obstruction. If the actuator clamp is loose, retighten the clamp on the blade shaft. If the actuator does not respond or behave as expected when powered, replace the actuator. Controls Issues: Neither damper responds when the unit is turned on or changes modes. 4. Ensure that the ambient conditions are correct for the unit to be in free cooling mode. For dry bulb controls: The air entering the OA inlet for the unit has a temperature between the high and low Limit settings. (Note: The low limit setting must be below the high limit setting in order for the unit to be in free cooling mode.) For enthalpic controls: The air entering the OA inlet has a temperature above the low limit setting, and an enthalpy below that of the air entering the inlet. If the air conditions are such that the should be in free cooling mode and it is not, use the SOO to isolate the control component that seems to be malfunctioning and replace it. 38 RENEWAIRE.COM INSTALLATION, OPETION AND MAINTENANCE MANUAL 1.800.627.4499

WARNTY 11.0 FACTORY ASSISTANCE In the unlikely event that you need assistance from the factory for a specific issue with the or its Bypass Economizer Option, make sure that you have the information called for in the Unit Records pages at the front of this manual. The person you speak with at the factory will need that information to properly identify the unit and the installed options. To contact RenewAire Customer Service: Call 800-627-4499 Email: RenewAireSupport@RenewAire.com Remember that RenewAire Customer Service can only assist with the and its options, it cannot resolve engineering issues that result from air handling system design by others. 12.0 WARNTY The Bypass Economizer Option is covered under the standard RenewAire warranty. A copy of the warranty is included with the unit manuals. If the warranty should be lost or misplaced, a PDF version can be downloaded from: http://www.renewaire.com/support/for-the-professional/documentation/warranty-information 1.800.627.4499 INSTALLATION, OPETION AND MAINTENANCE MANUAL RENEWAIRE.COM 39

ABOUT RENEWAIRE For over 30 years, RenewAire has been a pioneer in improving people s health, cognitive function, productivity and wellbeing by enhancing indoor air quality (IAQ) in homes and buildings of every type. This is done energy-efficiently, cost-effectively and sustainably via our fifth-generation, static-plate, enthalpy-core Energy Recovery Ventilators (s) and Dedicated Outdoor Air Systems (DOAS) that reuse otherwise-wasted energy to condition incoming outdoor air. This process optimizes energy efficiency, lowers capital costs by reducing HVAC loads and decreases operational expenses by downsizing equipment, resulting in major energy and cost savings. RenewAire technologies also enjoy the industry s best warranty with the fewest claims due to tremendous reliability, flexibility and ease of use. USA (800) 627-4499 FAX: (608) 221-2824 201 EMISCH ROAD WAUNAKEE, WISCONSIN 53597 USA WWW.RENEWAIRE.COM CANADA (905) 475-8989 FAX: (905) 475-5231 WWW.MITSUBISHIELECTRIC.CA MEXICO, CENTL &SOUTH AMERICA 52 (222) 2 233 911 FAX: 52 (222) 2 233 914 WWW.SOLER-PALAU.MX RenewAire was the first innovator with static-plate, enthalpy-core technology in the U.S., and is currently one of the largest companies in the country. Committed to sustainability and protecting the environment, our manufacturing facility in Madison, WI is 100% powered by renewable energy and is on track to be one of the few buildings worldwide with LEED Gold, Green Globes and ENERGY STAR certifications. Our technology excels in every geography, every climate, every building and every application, enabling RenewAire to be everywhere. In 2010, RenewAire joined the Soler & Palau Ventilation Group, providing direct access to state-of-the-art, air-moving technology. For more information, visit: www.renewaire.com. 138283_001 (05/18) 40 RENEWAIRE LLC COPYRIGHT MAY 2018