B297SB-01-1K40. AnyWireASLINK System Product Guide. ASLINKSENSOR [Photo Interrupter type] -B297SB011K40 1/7- [Function] [Notes on Safety]

Similar documents
EVS RP6020. Instruction Manual

Filterpack FR-BFP2-(H)0.4K to (H)15K

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

RP Instruction Manual

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Lumitester PD-20 Control Kit

DIN Track Terminal Blocks with Screw Terminals

DIN Track Terminal Blocks with Screw Terminals XW5T

24V Supply Operation & Specifications Manual. Field Tools. General Description

Grundfos MAGNA, Relay Module

DC REGULATED POWER SUPPLY

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

High-speed detection even a little liquid leak

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

User Manual. Solar Charge Controller 3KW

DIN Track Terminal Blocks with Screw Terminals XW5T

Duplex Booster System Instruction Manual

OPERATING INSTRUCTIONS

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Extended Panel Operation Manual RKP001Z-0

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

TOWA SEIDEN INDUSTRIAL CO., LTD.

User Manual Solar Charge Controller 3KW

HV Gate Valve with pneumatic actuator

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Model 1693, 1694 Switching DC Power Supply

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Unit 2, Rivington View Business Park, Station Road, Blackrod, Bolton BL6 5BN Tel: +44(0)


SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

RECHARGEABLE 24 LED WORK LIGHT

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

Power Inverter 400 MW Owner s Manual

High Frequency SineWave Guardian TM

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

LS200 Series Instruction Manual

POWER REGULATOR LD -40PSU

EX-F70 SERIES EX-F60 SERIES

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

BEFORE USING THE PRODUCT

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

INSP-3 Wiring Inspection Tester

Technical Documentation

HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC)

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

SHOCK RELAY R INSTRUCTION MANUAL WARNING

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

Switching DC Power Supply

Operations Manual. Zero Speed Switch Sensor Model ZS09P

SI unit for AS-Interface EX250-SAS#

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

SG-B1 SERIES / SG-A1 SERIES

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

A22LK CSM_A22LK_DS_E_6_2

Differential Pressure Transmitter

Better Productivity by Standstill and Low-speed Monitoring

Table of Contents 文管中心 發行章

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Universal 8-Bay Charger. for AA/AAA/C/D/9 NiMH & NiCd Rechargeable Batteries. Owner's Manual

SeekTech Inductive Clamp

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

230VAC Power Inverter 400W Owner s Manual

Geotech Hand Pump. Installation Guide. Rev. 2 6/18/02 Part #

19mm Thickness. Phone: Fax: Web:

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Tina 4A Connection block

FX2N-2LC SPECIAL FUNCTION BLOCK

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Model 1900, 1901, 1902 Switching DC Power Supply

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Pneumatic Drive Type Drill Bit Breakage Detection Sensor. DFM3 Series. The World's First!! Pneumatic-Drive Type. Catalog / Instruction Manual US.PAT.

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Installation and Operating Instructions. Solar System Controller ISC3020

Aura Interior Wiring Manual (5-Wire and BACnet)

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

RU BMS Power Supply and Battery Management System Owners Guide

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

VF-S11 RS485 built-in board option RS4003Z Instruction Manual

Not affected by drops, bubbles or froth

Introduction. Tool units covered by this Instruction manual NX020T2-07M1-20 NX050T2-07M1-20 NX100T2-07M1-20

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Tina 11A Connection block

General Guidelines. Instructions for Part # SC-SWING-AWAY-V2. Safety

BIM-17-2 Bus Interface Module for compass and outside temperature

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Transcription:

READER/WRITER LotNo.*** MADE JAPAN AnyWireAS System Product Guide ASSENSOR [Photo Interrupter type] B297SB-01-1K40 [Notes on Safety] Precautions that must be observed in order to use this system safely are indicated as shown below. You must observe these precautions. [Function] Model Detection method Function ASSENSOR (non-insulation) Transmission type Alarm judgment value Alarm judgment time Light ON/dark ON Operation mode Sensing level drop Slave unit voltage drop! WARNG! CAUTION A WARNG indicates a potentially hazardous situation which, if not handled correctly, could result in death or serious injury. A CAUTION indicates a potentially hazardous situation which, if not handled correctly, may result in personal injury or property damage. [Contents in package]! WARNG! CAUTION System Safety This system is intended for general industrial applications. It does not have functions for supporting applications requiring higher levels of safety such as safety-related devices or accident prevention systems. The product must not be used for these purposes. Always turn off the power before attempting to mount or replace. Prolonged continuous flow of a rated load current or higher or a transit current due to load short-circuit, etc., in the hybrid unit including the output unit and the output circuit may result in smoking or firing. An external safety device such as a fuse must be installed. System Use a stable, DC. Use of an unstable may cause problems with the system. Separately route high-voltage and power cables Although the AnyWireAS has a high noise margin, lay the transmission lines and I/O cables so as to keep them away from high-voltage and power cables. Connectors and s Pay careful attention to the length and installation of cable wiring to ensure that connectors and cables are neither stressed nor disconnected even if they are stressed. Make sure to prevent any metal objects from getting inside the connectors or the blocks. Short-circuits caused by metal objects or mis-wiring are likely to damage the device. Do not impose any external loads on the units. Doing so may cause a failure. Do not disconnect or reconnect between the transmission line and slave units. A malfunction may occur. Use the AnyWireAS within the range of the specifications and conditions shown below. Unit 1 unit *An address writer ARW-04 (Ver.04-1.01 or higher) or ARW-03 (Ver.2.10 or higher) is required for setting to the unit. Prepare it together. ARW-03 [Name of each part] Transmission type Front Setting port The version is displayed when POWER is on. A Ver.*.** is described on this label. indication Input indication indication ARW-03 Ver.2.10 Back Optical axis mark Detection part [Warranty] Warranty period The warranty on the delivered Product shall continue to be effective for one (1) year after the delivery thereof to a location as designated by the original owner. Scope of warranty Should a defect occur in any part of the Product during the foregoing warranty period when it is used normally in acordance with the specifications described in this User's Manual, the Company shall replace or repair the defect free of charge, except when it arises as a result of: [1] Misuse or abuse of the Product by the owner; [2] Fault caused by other than the delivered Product; [3] The unauthorized modification or repair of the Product by any person other than the Company's personnel; [4] Any unusual force of nature, disaster or other cause beyond the Company's control. The term "warranty," as used herein, refers to the warranty applicable to the delivered product alone. The Company shall not be liable for consequential or incidental damages resulting from any malfunction. Repair at cost After the expiration of the warranty period, the owner shall be responsible for all costs and expenses incurred for the troubleshooting and repair of the Product. Even during the warranty term, the Company shall repair any defects arising from causes other than within the scope of the warranty as specified above, at the owner's cost. Transmission cable Installation hole Installation hole (Red) (Black) [Type] AnyWireAS: Photo interrupter type (U-shaped standard) B297SB-01-1K40 Input 1 point -B297SB011K40 1/7-

[AnyWireAS Connection Method] The AnyWireAS can employ a two-wire or four-wire selectively depending on the load current. This Products Guide describes a two-wire (non-isolated). If the load current is small, using a two-wire (non-isolated) allows for achieving simplified wiring without local. In the case of prioritizing the sites of concentrated loads and/or the number of connections, hybridization with a four-wire (isolated), which supports local, is also possible. Make sure to use a four-wire (isolated) in the case of input and load driving using an external. In the case of hybridization, refer to the Four-Wire (Isolated) Terminal Products Guide separately. [Connection Example] Connection example using a two-wire (non-isolated) AnyWireAS DC* Black: * Make sure to use a DC stabilized for the to be connected. * When complying with the UL Standard, make sure to use a DC stabilized of NEC Class 2 Output. Red: Red: Black: Red: Black: Red: Black: Red: Black: Red: Black: Red: Black: ASAMP ASAMP ASAMP ASAMP Example of mixture of (non-insulation), (insulation) s AnyWireAS DC* Red: Black: AS filter Red: Black: Red: Black: Red: Black: Red: Black: Red: Black: Red: Black: Red: Black: Eight points Red: Black: ASAMP ASAMP ASAMP ASAMP General-purpose cabtire cable Dedicated flat cable 1.25mm 2 (two-wire) 2P link connector is convenient for branching. Total of line portions of, is total length. The branching has no limitation. Black: Red: Dedicated flat cable 1.25mm 2 (four-wire) 4P link connector is convenient for branching. Eight points Black: Red: Red: Black: Total of line portions of, is total length. The branching has no limitation. Black: Red: AnyWireAS terminator One terminator should be connected to the, farthest from the AnyWireAS. Connect it correctly so as not to set the wrong polarity. Relationship between the size and length of the transmission line and the supply current (Table 1) Size of Supply current on the transmission line (, ) the transmission line (, ) Total length Total length: Over 50 m, Total length: Over 100 m, 50m or less no longer than 100 m no longer than 200 m 1.25mm 2 0.75mm 2 MAX 2A MAX 1.2A MAX 1A MAX 0.6A MAX 0.5A MAX 0.3A 0.5mm 2 MAX 0.8A MAX 0.4A MAX 0.2A DC* Black: Two points Red: Two points AnyWireAS terminator Red: Black: One terminator should be connected to the, farthest from the AnyWireAS. Connect it correctly so as not to set the wrong polarity. - Refer to Table 1 so that the size and length of the transmission CAUTION line and the allowable supply current lie within an appropriate range. - Connect the same symbols (, ) correctly between the AnyWireAS and each device. - The branching length or branch number has no limitation. - Include the length of the cable provided with the in the total line length. - Connect the terminator (polar) to the on the transmission line farthest from the AnyWireAS. In the case of connection to a load (e.g. CAUTION input/output port) controlled by a different than that used in the AnyWireAS, make sure to use a four-wire (isolated). Otherwise, a malfunction may occur. -B297SB011K40 2/7-

[Notes on Combined Use with Four-Wire (Isolated) Terminal] 2Local /branching of,, and exceeds the total length of 50m in a system to be supplied, serially connect the AS filter [Type ] or filter of COSEL Co., Ltd. [Type EAC-06-472] to and in the starting position of the side-by-side lines. This will improve noise resistance, reduce the impact of crosstalk by transmission signals and stabilize the signals. In any case of to the entire system from the driving or from the local, insert a filter. AnyWireAS POWER PE Insert the AS filter [Type ] regardless of installation method and distance when complying with CE Standard. DC stabilized Filter allowable power current Model Type Allowable power current AS filter MAX 5A/ DC Filter of COSEL Co., Ltd. EAC-06-472 MAX 6A/ DC of,, and exceeds AnyWire Type: Connection example (Figures below are wiring diagrams for explanation. Adjust actual arrangement depending on each device.) 1Power supply to the entire system DC stabilized AnyWireAS POWER PE DC stabilized N L FG POWER PE A B of,, and exceeds If (A+B) of the side-by-side lines of,, and exceeds Filter notation in the drawing POWER PE For details of, refer to Products Guide. -B297SB011K40 3/7-

COSEL Co., Ltd. Type: EAC-06-472 Connection example 2Local /branching (Figures below are wiring diagrams for explanation. Adjust actual arrangement depending on each device.) 1Power supply to the entire system DC stabilized AnyWireAS PE LE DC stabilized AnyWireAS PE LE of,, and exceeds of,, and exceeds DC stabilized N L FG PE LE * When using this filter, please be careful of the positions of and LE. A B If (A+B) of the side-by-side lines of,, and exceeds * When using this filter, please be careful of the positions of and LE. Filter notation in the drawing PE LE -B297SB011K40 4/7-

[How to connect] Connect the transmission line included with the base unit body to the transmission line from the unit. Connect correctly for the polarity of +/. Core finish outside diameter φ1.5 Transmission line Red: (+) Black: ( ) [Precautions for use] - This unit is used by connecting to the AnyWireAS transmission line. This unit does not operate even if it is directly connected to the I/O card etc., of the sequencer. - Use this unit in a proper voltage range. - Also include the attached transmission line included with the unit in the total length. [Various settings] Items UL style 2103 Two cores of No.24 AWG (black) φ4.1 Address No. setting Parameter setting Example of mounting an LP connector to the end of the transmission line Applicable LP connector: LP2-PWH-10P Place the lines in the groove so that the black line () is positioned nearer the hinge side of the cover, and fold the part A onto the part B side and then hitch the hook C to fix the cover. Common procedure for address writer operation Be sure to connect to the AnyWireAS unit to use. The operation requires the address writer ARW-04 (Ver.04-1.01 or higher) or ARW-03 (Ver.2.10 or higher). Refer to the address writer s Products Guide for details of the operation method. A C B Cover In this cover-mounted state, check if the hooks 1 and 2 are fitted. 1 2 1. Connect the ASSENSOR slave to the unit of the AnyWireAS system. Set with the address writer while supplying the transmission signal (, ). Transmission signal Hole to pass the clamp Insert the body clamp into the hole of the cover and crimp them with a dedicated tool. Clamp Red: Black: AnyWireAS DC* * Make sure to use a DC stabilized power supply for the to be connected. Dedicated tool: LP-TOOL 3 4 2 1 2. Setting is required for all ASSENSORs. Direct the address writer to the setting port (Fig. 1) of the unit to set. (Put the light emitting and receiving surface as close to the setting port as possible.) After crimping, check if the hooks 3 to 6 are fitted securely. 5 6 [Example of installation] This can be installed in 2 directions. M3 fastening torque: 0.5N m or less Indication section Fig. 1 Setting port CAUTION When securing the unit, allow a margin so that no stress is applied to the cables and connecting connectors etc. Do not tighten the screws excessively. Doing so may cause a failure. When predicting confirmation of operating state and change of setting, install it so that the indication section is on the front. Address No. setting An address number is set as a beginning number from which part of the transmission frame is occupied to the. Set the address number within the range of 0 to 254. [Installation Location] - Places free from direct vibration or shock - Places not directly exposed to dust - Places not directly exposed to metal waste or sputter - Places free from condensation - Places free from corrosive gas, flammable gas or sulfur - Places away from cables of high voltage or large current - Places away from cable controllers generating high-frequency noise such as servomotors or inverters CAUTION The factory address-number setting of the is 255, which means no setting. If the address number setting is 255, the cannot perform an input/output operation. Make sure to use the after setting the address number within the range of 0 to 254. -B297SB011K40 5/7-

Parameter setting Setting alarm value Hi Set the upper limit of an alarm judgment value. Address writer (ARW-04, ARW-03): Parameter 03 Unit 0-100 % Before shipment: 80 * Set the alarm value under the condition of Hi>Lo. Setting alarm value Lo Set the lower limit of an alarm judgment value. - Address writer (ARW-04, ARW-03): Parameter 04 Unit 0-100 % Before shipment: 20 * Set the alarm value under the condition of Hi>Lo. Setting alarm value monitor time Set the monitor time of the alarm judgment value. - Address writer (ARW-04, ARW-03): Parameter 05 Unit 3-255 100ms Before shipment: 50 [Troubleshooting] When the following errors are indicated on the display window of the main body, take measures as shown below. Cause Measures Off Off Off On Off Flashing Off (0.5 seconds alternately) Off Flashing (0.5 seconds alternately) - - Flashing (On for 0.2 seconds, off for 1.0 second) Flashing - On - Power supply, AnyWireAS are not connected to the ASSENSOR. - Power supply for the AnyWireAS system itself is not turned on. - Directly connected to 24-. - The ASSENSOR maintains the address 255 (setting before shipment). - The ASSENSOR has an address duplicated with the other unit. - The internal power voltage of the ASSENSOR lowers. - The sensing level lowers. When the following errors are indicated on the address writer, take measures as shown below. Indication Cause Measures E-0303 The set parameter is incorrect. - Confirm that there is no disconnection between the ASSENSOR and the AnyWireAS system, and recover the connection. - Confirm the power status of the AnyWireAS system, and turn on the power. - Re-connect to the AnyWireAS system. - Set any address other than 255. - Look for any other unit which has the same error indication, and set any address different from it. - Decrease the number of units connected to the same AnyWireAS system. - Shorten the transmission line between the ASSENSOR and the unit. - Check the status of the ASSENSOR, then adjust the optical axis, and clean the light emitting and receiving surfaces, etc. Confirm the parameter correspondence table and set the correct parameter. Setting Light ON/Dark ON Set light ON/dark ON - Address writer (ARW-04, ARW-03): Parameter 06 0 Dark ON 1 Light ON Content Setting operation mode change Before shipment: 0 Set with/without alarm diagnosis function. - Address writer (ARW-04, ARW-03): Parameter 07 Take measures as follows in the following case. Symptom Measures Detection - Is the wiring correct? cannot be performed. Confirm that the transmission line of ASSENSOR is correctly connected to the transmission line (, ) of AnyWireAS. - Is power of proper capacity supplied to the AnyWireAS unit and slave unit? Check the power. Setting cannot be performed with an address writer. - Is connecting correct? Re-confirm the sensor head and the connection of the transmission line. - Is power fed to the AnyWireAS system? Confirm the. - Is the set parameter correct? Confirm the parameter correspondence table and set the correct parameter. 0 Simple mode 1 Normal mode [Monitor Display] Content Alarm diagnosis function unavailable Alarm diagnosis function available Unit operation status is indicated by the LED. Display name Indication class Content Before shipment: 0 Parameter [8.] and subsequent parameters are parameters in the system domain. Do not change the setting with the address writer. (Green) Power/Transmission indication Flashes when transmission signal is received. (Orange) Work detection indication Turns on or off when work is detected. (Yellow) Unit trouble indication Indicates trouble status of the unit. [Parameter and Item] Parameter Content 03. 0-100% Set the upper limit of the light receiving Alarm value Hi value that generates an alarm. 04. 0-100% Set the lower limit of the light receiving Alarm value Lo value that generates an alarm. 05. 3-255 Set the monitor time of the light receiving Alarm value Monitor time value that generates an alarm. (1=100 ms) 06. 0 Dark ON Light ON/ Dark ON 1 Light ON 07. Operation 0 Simple mode mode 1 Normal mode before shipment 80 20 50 0 0 (Orange) (Green) (Yellow) Setting port -B297SB011K40 6/7-

[Specifications] General Specifications Ambient temperature/humidity use Ambient temperature/humidity storage Atmosphere use Altitude use * 1 Pollution level * 2 0 to 55 C, 10 to 90RH (No condensation) -25 to 75 C, 10 to 90RH (No condensation) No corrosive gas 0 to 2000m 2 or less *1 Do not use or store AnyWireAS devices in an environment where the pressure is larger than the atmospheric pressure at an elevation of 0 m. A malfunction may occur. *2 Indicates the degree of occurrence of conductive objects in an environment where the device is used. At the level of pollution level 2, only non-conducive contaminants occur. However, the environment may cause temporary conduction due to accidental condensation. Transmission specifications Power supply voltage use Transmission method Synchronization method Transmission procedures Connection form Number of connection points Number of connection devices RAS function Voltage 24[V] DC+15 to -10%(21.6 to 27.6[V] DC Ripple 0.5[V]p-p max. DC superimposing total frame cyclic method Frame/bit synchronization method Dedicated protocol Bus type (multi-drop, T-branch, tree method) MAX 512 points (: 256 points, OUT: 256 points) MAX 128 devices Transmission disconnection detection, transmission short-circuit detection, transmission drop detection, ID duplication and ID non-setting detection Individual specifications I/O points Current consumption Detection method Detection distance Response time*3 Mass Input 1 point Supplied from AnyWireAS transmission signal (, ) 11 ma Infrared ray transmission 5 mm (groove width) One cycle 27g *3 Time from detection of ON or OFF to sending of transmission signal. This time and transmission 1 cycle time are transmission delay time. Sensing Specifications Function Light source (Light emitting wavelength) Invisible light light source type Infrared ray LED 940 mm [Outside Dimensions] Unit: mm 1000 26 9 2-φ3.8 5 19 25.4 19 Red: Black: 2-φ3.8 Core finish outside diameter φ1.5 11 7 16.7 [Address] Anywire Corporation 6.4 Bending-proof cable (2 24AWG) Headquarters :1 Babazusho, Nagaokakyo-shi, Kyoto 617-8550 JAPAN Contact :Contact by mail info_e@anywire.jp :Contact by website http://www.anywire.jp Blackφ4.5 -B297SB011K40 7/7- Printed in Japan 2013, 2014, 2015, 2016, 2017 UMA-09380E-EN