ECON-ZIP-DETF; ZIP PACK

Similar documents
ZIP Economizer Fault Detection and Diagnostics (FDD) Table

INSTALLATION INSTRUCTIONS ECOHLX Series Horizontal Economizer and PEHALX Series Economizer with Power Exhaust for York LX Series. Warning.

Installation Instructions

Installation Instructions

Installation Instructions

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

Metasys Zoning Package Installation

Installation Instructions

Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory.

Installation Instructions

VisionPRO 8000 Thermostats

Installation Instructions

Appendix A: Inputs, Outputs, and Parameters

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

SE8300 Series Installation Guide 24 Vac Low Voltage

LF Series At A Glance

Extending A99 Sensor Cables

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

ECONOMIZERS. 5/2012 Supersedes

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Installation Instructions DNECOMZR020A02, DNECOMZR021A03 (For 3 to 12.5 Ton Units) and DNECOMZR062A00 (For RHS 12.5 Ton Heat Pump Units)

ECONOMIZERS. 1/2012 Supersedes

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

Installation Instructions

Installation Instructions

MicroMetl. INSTALLATION INSTRUCTIONS Dual Stage Relief Economizer ECD-SRT12DR, ECD-SRT34DR, ECD-SRT5SDR & ECD-SRT5LDR

Mated ERV I/O/M manual

Description. functions including single duct pressure dependent or pressure independent systems.

Installation Instructions

Installation Instructions

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

Installation Instructions

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

Signet Pressure Transmitter

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient

Functional Performance Test

Minimum 27 in-lb Torque

TECHNICAL INFORMATION MANUAL

Combined Ventilation Controller RVWS-T-224HA

Installation, Service, and Troubleshooting Instructions

- Wiring Brochure tekmarnet 4 Thermostat 545

SSZ 14 SEER Split System Heat Pumps

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

FAST-STAT. Model 3000 Installation Instructions. Application. Troubleshooting not operating. Before Installing This Product. Sender Installation

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

Package Unit Modulating Economizer Installation Instructions

ECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102*

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

FSAF24(-S) US, FSAF120(-S) US

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

SSZ 16 SEER Split System Heat Pumps

Engineering Bulletin. IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51)

RDG160TU Commercial Thermostat

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

Package Unit Modulating Economizer Installation Instructions

Signet Temperature Transmitter

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h

E1.x Instruction Manual Supplement for Model 32 and 40

SMT-AZC INSTALLATION / OPERATION MANUAL

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h

Signet Pressure Transmitter

Quick Setup Guide for IntelliAg Model YP Air Pro

ULTRA-ZONE FORCED AIR ZONE CONTROLS EWC

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

N-1001 Economizer Logic Network

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

Combined Ventilation Controller RVWS-T-113HA

SE7200 Series Installation Guide

MicroTech Applied Rooftop Unit Controller: VAV Control

WATER CONTROL SYSTEM QUICK START +1 (208)

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

Minimum 18 in-lb Torque

INSTRUCTIONS FOR (-)XRX-AW04 or (-)XRX-AW05 MOTORIZED FRESH AIR DAMPER KIT

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h

Versatile and Powerful

SP PRO ABB Managed AC Coupling

SE8300 Series Installation Guide 24 Vac Low Voltage

Installation, Operation and Maintenance Manual

Minimum 27 in-lb torque

STRA-24 for chilled beams

Installation Instructions

Installation Instructions

Torque min. 35 in-lb, for control of air dampers

2001 Dodge Caravan Sport MANUAL A/C-HEATER SYSTEMS Caravan, Town & Country, & Voyager

P445 Series Electronic Lube Oil Control

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Transcription:

71765-00001_A INSTUTION MANUAL EON-ZIP-DETF; ZIP PAK EON-ZIP-DETF; ZIP PAK Differential Enthalpy with DV apability and TF Spring eturn Actuator ontains: Application This kit offers all the components to retrofi t an economizer on a direct expansion TUs up to 7.5 tons while utilizing single enthalpy changeover strategy. In this, the ZIP Economizer will calculate the Outdoor Air Enthalpy and eturn Air Enthalpy compare the values to each other- as well as analyze the Outdoor Air Temperature & Humidity Values to the referenced temperature and humidity high limits. One outside temperature & humidity sensor will be place in the outside damper, one temperature & humidity sensor will be placed in the return, and one temperature sensor the other in the supply duct. That high limit changeover temperature and enthalpy value is adjustable. EON-ZIP-BASE (2) EON-ZIP-TH TFB24-S and etrofit Kit When the included energy module is used (EON-ZIP-EM), the following options become available: demand control ventilation, pre occupancy purge, power exhaust, remote damper position override, fan speed switch. EON-ZIP-EM EON-ZIP-10K Wiring Diagrams AT 1 57 1 - ommon Notes: THEMOSTAT 51 G O W1 52 56 O/B Y1 Y2 Single Dry Bulb TU TEMINAL O W1 Y1 Y2 TU Stage 1 Mechanical ooling ircuitry 53 TU Stage 2 Mechanical ooling ircuitry 1 2 AT1 AT2 AT3 AT5 G W1 SAT+ SAT- Y1 Y2 1 2 AT+ AT- AH+ AH- OAT+ OAT- OAH+ OAH- EON-ZIP-BASE AT+ T (+) AT- T (-) AH+ H (+) H (-) AH- 24 V () EON-ZIP-TH eturn Air Enthalpy 50 AT 2 AT 3 AT 5 SAT + SAT - OAT + OAT - OAH + OAH - 2 + Hot 3 Y Input, 2 to 10V 5 U Output, 2 to 10V -S EON-ZIP-10K Supply Air Temp T (+) T (-) H (+) H (-) 24 V () EON-ZIP-TH Outside Air Enthalpy 50 50 54 50 Power source should be the same as EON-ZIP-BASE. 51 52 53 When the thermostat is not equipped with occupancy control, "Fan On" output "G" shall be wired to the EON-ZIP-BASE. W1 must be wired for Heat Pump operation if conventional thermostat is used in conjunction with Defrost Board. If Thermostat and TU use O/B control reversing valve position, O/B must be wired to W1 on EON-ZIP-BASE. Existing refrigeration safety devices may exist, consult TU wiring diagram 54 Not supplied by Belimo. 55 Sold separately by Belimo 56 57 If TU is not a Heat Pump using a conventional thermostat and it is desired to record heating operation hours, connect W1 to EON-ZIP-BASE. Actuators can be mounted in parallel with the AT3 output from the ZIP Economizer. The AT5 feedback input should be wired to the Outside Air damper actuator feedback wire. 1 - ommon 2 + Purge ontact Thermostat 24 VA AUX1+ AUX1 + O2 + O2 + 3 + Y Input, 0 to 10 VD 4-0 to 10 VD ommon - 1 + 2 Y Input, 2 to 10 VD + 3 2 to 10 VD + 4 SGA24 SGF24 50 AUX2 + AUX1 - AUX1 - O2 - AUX2 + IF AUX2 - EF EON-ZIP-EM O2 - O2 Sensor Indoor Fan Low Speed elay / VFD Enable Exhaust Fan ircuit 52 55 Energy Module

Setup and onfiguration Quick Setup WANING Live Electrical omponents! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Installation 1. Shut off power to TU before beginning installation. 2. Note orientation, opening rotation, and spring return rotation of damper assembly. Mount Actuator to Outside Air and eturn Damper assembly. To ensure tight outside air shutoff; while tightening actuator clamp push damper closed. 3. Terminate required Inputs and Outputs(I/O): For the ZIP Economizer to function correctly, the following I/O, at a minimum, are required to be terminated, wired, and functioning (,, Y1, Y2, G, 1, OAT, SAT, AT1, AT2, AT3, AT5). See wiring diagrams. 4. Sensor confi guation: The ZIP Economizer automatically detects sensors attached and automatically confi gures for single dry bulb, single enthalpy, differential dry bulb and differential enthalpy. MMI Keypad Moves up through the menu on the same level. Will increase values by one increment at a time. When setting values holding key down will fast scroll Enter sub menu level. Start editing a setting. Store an entered value. esc Moves down through the menu on the same level. Will decrease values by one increment at a time. When setting values holding key down will fast scroll. Escape sub menu to next higher level. ancel current actions. i Show additional information on the current menu Item when i appears in lower right of display. Settings Settings is the menu displayed when the ZIP Economizer is fi rst powered. Press OK to parameterize required settings. eference above Keypad Key defi nition instructions and navigate as needed. Functions 1. Monitor Live onditions is used to display settings and live values. 2. Settings is used to parameterize the ZIP Economizer. (Note: Devices 1 is for 1, 2, EF, IF; Devices 2 is for OAH, AH) 3. Present Devices is used to verify that the ZIP Economizer's Auto Detected connections are terminated properly. If connected device is not shown, verify wiring. If wiring has continuity and device is verifi ed operational re-enter Settings and enable missing device by changing from Auto to Available or Installed. 4. Alarms is used to view current and historical alarms and delete inadvertently caused alarms. 5. Service and ommissioning submenu is used to operate the TU in Manual Mode or to perform Acceptance Test. Settings must to be completed to access. 6. Status is a display of the current operating mode. It can be accessed by pressing esc. The action of pressing any key will drop the user down from Status to the next level, so repeatedly pressing esc will toggle the display between Status and Monitor Live onditions. (Note: If status Setup incomplete is displayed the TU cooling operation will be disabled and additional parameters must be set to achieve Setup complete.) 2

Setup and onfiguration Quick Setup equired "Settings" Parameters for All onfigurations Note: you may enter parameters in any order - eg: Vent min Pos before ZIP ode - If the TU is a heat pump or uses a 2 speed indoor fan, these paramaters should be enabled fi rst, otherwise the logic may go to Setup omplete prematurely. 1. ZIP ode US or anada (sets the free cooling changeover high limit and temperature units F/) a. When the Zip ode submenu is displayed enter OK to begin US Zip ode parameterization. If anada Postal ode is desired press the up/ down arrow to access. i. Press OK to access digit 1 (fl ashing) then use the up/down arrow to parameterize; enter OK when complete. epeat until all digits are complete. If a mistake is made press esc and repeat from beginning ii. When all Zip ode or Postal ode digits are entered press esc to move up a level then press the up/down arrow to access next settings parameter. 2. Vent Min Pos (Outdoor Air Damper Ventilation Minimum Position) a. When the Vent Min Pos submenu is displayed press OK to parameterize (fl ashing). b. Use the up/down arrow to parameterize, press OK when complete. The actuator will immediately drive the damper to the minimum position. 3. Additional Parameters may require setting. The ZIP Economizer will autodetect added Devices such as a O2 sensor etc. When the ZIP Economizer detects a new device, it will prompt the user in the Status level; navigate to Settings and parameterize blank fi elds. If the devices are connected upon fi rst start up their settings will require parameterization then. 4. When all parameters have been set, the ZIP Economizer will show Setup omplete if there are still parameters to set, there will be no action. You can verify by pushing esc until status level is reached and it will display Setup Incomplete. If this is the case, re-enter settings menu and use up down arrows to fi nd the parameter with blank fi elds and parameterize as described above. Setup omplete - Initializing Automatic Mode 1. When all entries have been completed, the ZIP Economizer will switch to Status display and show Setup omplete, and will immediately show a Damper scaling starts in 10secs and will countdown to 0 (be aware, at 0 the damper will start to move at high speed). A message will scroll saying Damper scaling for better operation if obstruction is present rescale damper in commissioning menu. (For detailed instructions on this please see the section Service and ommissioning below. This will open damper to 100% (re-scale control signal if needed). (Note: failure to identify obstructions or improper setup of damper assembly may result in an improper scaling and operation of the damper.) Once scaling is complete, a message will appear saying Damper scaling successful. The ZIP will then show maximum at 80 = 100% That message will show maximum rotation of the damper. This process ensures the damper is always operating and displayed from 0-100%. 2. Once the message has appeared, the actuator immediately closes the damper and a countdown begins, until the unit starts to operate in Automatic Mode (be aware, when countdown complete, the TU will respond to thermostat calls which may enable mechanical cooling). Service and ommissioning (Acceptance Test & Manual Mode) The ZIP Economizer has built in commissioning processes found in Acceptance Test. 1. Economizer Test. Use Economizer Test to verify TU Integrated Economizer operation. Navigate to the Service and ommissioning menu, press OK ; press the down arrow to access Acceptance Test. Press OK again when Economizer Test appears. Press OK again to confi rm running test. Follow prompts during test. This test will open damper to 100%, enable power exhaust fan (if connected), enable 1st stage of Mechanical ooling, reverse this process and then drive to Vent Min Position. When used with a Belimo actuator, the actuator will speed up to reduce test time. 2. Manual Mode is used to override outputs after entering a Timeout duration. 3. Damper Scaling. The test will re-scale the control signal range to maximum resolution (0-100%) over the calibrated (reduced) angle. When using a Belimo actuator, the actuator will speed up to reduce test time. Note: Failure to identify obstructions or improper setup of damper assembly may result in an improper scaling and operation of the damper.) Note: Additional testing can be found on page 36 of this document. 3

Menu Structure Tables Settings Menu Item Parameter Default ange Notes Zip ode 1 US 00000 5 Digit Num anada 000000 6 Digit Alpha/Num Setting of either US or anada code required for Economizer Operation. Setting the ZIP code automatically configures the economizer high limit change over temperature to comply with local energy code. If the user desires a different high limit value, this can be modified in the settings menu under high limit modification. Setting of either US or anada code required for Economizer Operation. Setting the ZIP code automatically configures the economizer high limit change over temperature to comply with local energy code. If the user desires a different high limit value, this can be modified in the settings menu under high limit modification. Heat Pump Op Heat Pump Op HP (O) = pow = ool HP (B) = pow = Heat HP (W1) = pow = Heat If the TU that the economizer is installed in, is a heat pump, then this value shall be set to one of the following: (O) = eversing valve powered for cooling. (B) = eversing valve powered for heating. (W1) = Standard thermostat, reversing valve controlled by internal TU defrost board. ompressor Qty 8 Number of ompressors Auto 2 No compressor detected ompressor 1 detected ompressor 2 but no ompressor 1 detected ompressors 1 and 2 detected ompressors 1 and 2 selected ompressor 1 selected Message appears only during initial setup. If No ompressor is detected, verify wiring, check continuity, if all is correct, push OK to set quantity. If only 1 compressor is detected, and there are 2 installed verify wiring, check continuity, if all is correct, push OK to set quantity. Fan 2 Speed 4 Auto 2 Auto, Available, Not Available Allows for 2 speed indoor fan control circuit (IF) to be automatically detected when wired. If circuit is not automatically detected, the functionality can be manually enabled by choosing available. If there is a desire to disable functionality for any reason, the operator can choose not available and the operation of the economizer will function as if the device is not installed or configured. Devices 1 1, 2, IF, EF, (as connected) Devices 2 OAH, AH, (as connected) ompressor Qty 3 Auto 2 Auto, 1, 2 Exh Fan Install 4 Auto 2 Auto, Installed, Not Installed OAH 5 Auto 2 Auto, Installed, Not Installed AH 5 Auto 2 Auto, Installed, Not Installed Allows for up to 2 compressor circuits (1, 2) to be automatically detected when wired. If circuit is not automatically detected, the functionality can be manually enabled by setting compressor Qty to 1 or 2. Allows for exhaust fan control circuit (EF) to be automatically detected when wired. If circuit is not automatically detected, the functionality can be manually enabled by choosing available. If there is a desire to disable functionality for any reason, the operator can choose not available and the operation of the economizer will function as if the device is not installed or configured. Allows for the Outside Air Humidity Sensor to be automatically detected when wired for enthalpy change over strategy. If the sensor is not automatically detected, the humidity sensor can be manually enabled by choosing installed. If there is a desire to disable functionality for any reason, the operator can choose not installed, and the operation of the economizer will function as if the device is not installed or configured. Allows for the eturn Air Humidity Sensor to be automatically detected when wired for differential enthalpy change over strategy. If the sensor is not automatically detected, the humidity sensor can be manually enabled by choosing installed. If there is a desire to disable functionality for any reason, the operator can choose not installed, and the operation of the economizer will function as if the device is not installed or configured. 4

Menu Structure Tables Menu Item Parameter Default ange Notes Vent Min Pos 1 Vent Min Pos % 0-100% DV Min Pos 4 DV Min Pos % 0% - Vent Min Pos % DV PPM Set Pnt 4 DV PPM Set Pnt ppm 500-2000 ppm Setting the minimum position required for Economizer Operation. This is where the outdoor damper minimum position is set. This is the position that the damper will travel to during occupied periods (when terminal G on economizer is powered). The amount of outdoor air is different per application. Please consult local ventilation codes. This setting is typically related to a calculation that determines amount of fresh air for building area and people (Vbz = Ventilation Breathing Zone per ASHE 62.1). Actual airflow at a given position should be verified by field measurement. This is the Demand ontrol Ventilation minimum position. The DV min pos is a value always less than the design ventilation position. This is the position that the damper will travel to during occupied periods (when terminal G on economizer is powered) when the measure O2 Value is below the DV PPM Set Pnt. The amount of outdoor air is different per application. Please consult local ventilation codes. This setting is typically related to a calculation that determines amount of fresh air for building area (a = outdoor airflow rate required per unit area per ASHE 62.1) to allow continue flushing of VOs during occupied periods. Actual airflow at a given position should be verified by field measurement. This is the O2 concentration that is desired to maintain in the space. When the O2 sensor measures a concentration below this value, the damper control point will be reset and the damper will modulate towards DV Min Pos. When the measured O2 level increases above this value, the damper will start to modulate towards the Vent Min Pos to lower the O2 in the space. 2 Speed Fan Op 2 Speed Fan Operation On If the unit is factory installed with 2 speed fan capability, then this setting must be set to On to provide proper ventilation. Low Sp Vent Min 6 Low Sp Vent Min % "Vent Min Pos" % - 100% When a 2 Speed strategy is used to save energy, an additional Vent Min Pos needs to be entered for low speed operation due to less available static pressure from the fan. This position will be greater than Vent Min Pos, however equal the same measured airflow rate value. Low Sp DV Min 6 Low Sp DV Min % Exh Fan On Pos 4 Exh Fan On Pos % 0-100% Low Exh Fan Pos 6 Low Exh Fan Pos % 0-100% Temp Unit Temp Unit F F, Purge Enable 4 Purge ontrol On, "DV Min Pos" % - "Low Sp Vent Min" % Purge Dmp Set 4 Purge Dmp Set % 0% - "Vent Min Pos" % When a 2 Speed strategy is used to save energy, an additional DV Min Pos needs to be entered for low speed operation due to less available static pressure from the fan. This position will be greater than DV Min Pos, however equal the same measured airflow rate value. This is where the desired enable point for exhaust fan operation is set. As the outdoor damper increases or decrease past this position, the exhaust fan will be turned on or off. When a 2 Speed strategy is used to save energy, an additional Exh Fan On Pos needs to be entered for low speed operation due to less available static pressure from the fan. This position will be greater than Exh Fan On Pos, however equal the same measured space pressure. Allows the user to select Fahrenheit or elsius temperature display. When the ZIP Economizer is set up with a anadian Postal ode, the units are default to. This is where Pre-Occupancy purge control is enabled. Pre-Occupancy purge is a requirement in some codes to ventilate the building just prior to normal occupancy times. The function removes VOs that have gathered in the building during unoccupied period when the Outside air damper is normally closed. Purge ontrol requires using the expansion energy module and a thermostat or other time driven control that will enable supply fan and provide 24V to Aux 1 during the desired purge period. Setting of Purge Dmp Set is required for the function to work. This determines the position that the damper will open to during Pre-Occupancy purge. This position is usually based what will achieve the desired number of air changes. emote Dmp ntrl 4 emote Dmp ntrl On, This is where an optional outdoor air damper position override can be enabled. Input into AUX2 is 2-10 VD (2V damper closed - 10V 100% open). This function overrides all other damper position settings Except: not in Automatic, G not energized FP. 5

Menu Structure Tables Menu Item Parameter Default ange Notes Dry Bulb ZIP ode Dependent 60-80 F 16-27 Modification Fixed Enthalpy 5 Diff Enthalpy 28 BTU/lb 47 kj/kg ZIP ode Dependent 30 BTU/lb 52 kj/kg ZIP ode Dependent 25-28 BTU/lb 40-52 kj/kg 60-80 F 16-27 25-30 BTU/lb 40-52 kj/kg 60-80 F 16-27 SAT Y2 Limit SAT Y2 Limit On On, If the hange Over Setpoint that was determined by the ZIP ode setup is deemed to be not desirable for the application, then it can be modified here. With Differential Enthalpy, temperature can also be changed; offsets cannot. Note: a modification may result in less energy savings and non compliance with local energy code. SAT Y2 Limit is an energy saving function that prevents 2nd stage to get engaged when the Supply Air Temperature is at 56.5 F or below. When "On" there will be 4 min delay from the time Y2 is on until the 2nd stage compressor will be enabled allowing 1st stage to try to satisfy SAT requirement. When off, 2nd stage is not limited and compressor delay is 10 seconds. This function saves energy by having one stage of cooling satisfy space cooling requirements. 1. equired setting for Economizer operation. If the value is not set, outputs of the economizer such as compressors will not operate regardless of thermostat call. 2. Attached Devices will be automatically detected and the related functionality will be enabled. When devices are detected, they will appear in the Present Devices menu and the Setup Settings menu will also automatically configure to display parameter to setup. For example, when an Exhaust Fan (EF) is detected, the "Exh Fan On Pos" will show in the menu and will require setup. 3. At least 1 compressor is required (auto detected or chosen) for economizer to function. 4. equires the Energy Module connected and the accessory component powered, wired, and terminated to the Energy Module. 5. Only visible when Humidity Sensor is present. 6. equires the Energy Module connected, 2 speed fan installed, and the accessory component or device powered, wired, and terminated to the Energy Module. 2 Speed Fan can be enabled in settings menu. 7. Not visible when differential dry bulb or differential enthalpy change over strategies are used. 8. Only present at initial setup. 6