Three axis ( X, Y, Z ) electromagnetic field measurement 3 D EMF TESTER. Model : EMF-828

Similar documents
TABLE OF CONTENTS 1. FEATURES CAUTION OF ELECTROMAGNETIC FIELD EXPOSURE SPECIFICATIONS...2

EMF TESTER OPERATION MANUAL. ELECTROMAGNETIC FIELD RADIATION TESTER Model : EMF-832

MANUAL ELECTROMAGNETIC FIELD RADIATION TESTER EMF 823

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

Instruction Manual. IM-191 Magnetic Field Meter

Model LE-300C/LH-300C/LZ-300C Coating Thickness Tester. Operating Manual

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

OPERATING INSTRUCTION

Autoranging Multimeter

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Digital Force Gauge with RS232 Output Instruction Manual

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

1.Safe testing IMPORTANT:

True RMS Autoranging Multimeter

DIGITAL 5000 g x 1 g FORCE GAUGE TENSION & COMPRESSION

Mini Multimeter with Non-Contact Voltage Detector (NCV)

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

DPS280 / DVS280 Series

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

RS MODEL 2030

Dawson DDM190D. Digital Multimeter User s Manual

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Autoranging Industrial Multimeter

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

2-Color Display High-Precision Digital Pressure Switch

KMP Insulation-Continuity Tester. Users Manual

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Marin Control Digital

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

Solar Powered Wireless Temperature Station & Sensor

Model Insulation Tester / Megohmmeter. User Manual

SOKAR FPV DRONE. Quick Start Manual SkyRC Technology Co., Ltd. All Rights Reserved. Version

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

USER MANUAL. Insulation Tester + DMM. Model MG320

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

Instruction Manual. Coating Thickness Gauge. Optionally with Memory

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

A2 Humidity Temperature Indicator SUPPLEMENTAL INSTRUCTIONS

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Measuring Instruments for Paper Machines. Temperature Relative Humidity Air Flow

产品技术规范. Product Name: Product Technical Specification SMARTSTONE. No.: CPFL0002 Version: A Issued date: Page 1 of 16

TMA5 Mini Vane Anemometer

Safety design conforming to the following provisions

1 Form A 5A small size power relay for interface

Breath Alcohol Tester

JINLONG MACHINERY & ELECTRONICS CO., LTD. PRODUCT SPECIFICATION

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

BATTERY OPERATED DIGITAL MILLI-OHMMETER

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Flexible stop method Mounting attachment with slide stop mechanism

Check-Rod Type Mounting Attachment with Slide Stop Mechanism CCACC010- B (S) Instruction Manual EN E

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

Analog Input Terminal

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Pre-lab Questions: Please review chapters 19 and 20 of your textbook

Inductive Proximity Sensor

DIGITAL CLAMP TESTER MODEL HCL-5000D

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

DIGITAL MULTIMETER INSTRUCTION MANUAL

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

Data sheet SMD Wire Wound Chip Inductor WL Series

PRODUCT SPECIFICATION

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Chapter 7. Magnetic Fields. 7.1 Purpose. 7.2 Introduction

Portable Surge Protective Device Tester SPD T8 tester User Manual

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

Weatherproof Tubular Slip Ring Assembly

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

Advanced Test Equipment Rentals ATEC (2832)

Asset Protection Cathodic Protection Testing of Insulating Joints. Work Instruction No.:

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

RATE CONTROLLED TORQUE WRENCH TESTER

Inductive Proximity Sensor

Sensor SNS06 Shown. Monitor. Toughened Nut Sensor Installation Instructions With thread detection calibration procedures. 1.

Transmitter CSA-591 Instruction Manual

Digital/Analog Megohmmeter Model 1026

User Guide. Model Insulation Tester / Megohmmeter

testo 535 Instruction manual

DIGITAL RCD(ELCB) TESTER

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

APPEFNDIX 1 SPECIFICATIONS OF THE TEST ENGINE

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

SA1W: Water Detection Sensors

Wire Wound Chip Inductor-WB Series

Transcription:

Three axis ( X, Y, Z ) electromagnetic field measurement 3 D EMF TESTER Model : EMF-828

TABLE OF CONTENTS 1. FEATURES...1 2. APPLICATIONS...2 3. CAUTION OF ELECTROMAGNETIC FIELD EXPOSURE... 2 4. SPECIFICATIONS... 3 5. FRONT PANEL DESCRIPTION...5 5-1 Display...5 5-2 Power button... 5 5-3 Hold button...5 5-4 XYZ axis select button...5 5-5 Unit button...5 5-6 Range button... 5 5-7 Battery compartment/cover... 5 5-8 Stand...5 5-9 Probe input socket...5 5-10 Probe plug...5 5-11 Probe handle... 5 5-12 Probe sensing head...5 6. MEASURING PROCEDURE...6 7. RECOMMENDATION... 7 8. BATTERY REPLACEMENT... 7

1. FEATURES * Three axis ( X, Y, Z direction ) electromagnetic field measurement. * The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, electrical appliances and industrial devices. * Wide measuring ranges, 3 ranges of 20 micro Tesla, 200 micro Tesla & 2000 micro Tesla. * The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at wide bandwidths from 30 Hz to 300 Hz. * LCD display, jumbo digit size. * Data hold. * Separate probe, easy operation. * DC 9V battery power supply. * Hard case included. 1

2. APPLICATIONS This EMF tester is specifically designed to determine the magnitude of electromagnetic field radiation generated by power lines, computer's monitor, TV sets, video machinery and many other similar devices. 3. CAUTION OF ELECTROMAGNETIC FIELD EXPOSURE Claims by some scientists that long term exposure to electromagnetic field may be the cause of childhood leukemia & other forms of cancer. Complete answers to any of these and related questions are not currently available. At the present time the most common practice is to avoid excess exposure over long period of time. "Prudent Avoidance" as stated by the Environmental Protection Agency(EPA) USA is recommended. 2

4. SPECIFICATIONS Display Range / micro Tesla : Resolution LCD, 3 1/2 digits. LCD size : 55 mm x 47 mm. Max. indication 1999 counts. With display units. 20 micro Tesla/0.01 micro Tesla 200 micro Tesla/0.1 micro Tesla 2000 micro Tesla/1 micro Tesla mili-gauss : 200 mili-gauss/0.1 mili-gauss 2,000 mili-gauss/1 mili-gauss 20,000 mili-gauss/10 mili-gauss Number of Axis Three axis ( X, Y, Z direction ). Axis selected by push button. Band width 30 Hz to 300 Hz. Accuracy ± (4 % + 3 d) @ 20 micro Tesla range @ 200 mili-gauss range ± (5 % + 3 d) @ 200 micro Tesla range. @ 2,000 mili-gauss range ± (10 % + 5 d) @ 2,000 micro Tesla range. @ 20,000 mili-gauss range * Spec. accuracy tested under 50 Hz or 60 Hz. * Spec. tested under the environment RF Field Strength less than 3 V/M & frequency less than the 30 MHz only. 3

Over-input Display shows " 1 ". Sampling Time Approx. 0.4 second. Battery DC 9 V battery (006P, 6F22). Power Current Approx. DC 2.7 ma. Operating Temp. 0 to 50 ( 32 to 122 ). Operating Less than 85 %RH. Humidity Weight 460 g/1.01 LB (including battery). @ Including Probe and battery Dimension Main meter : 195 x 68 x 30 mm ( 7.6 x 2.6 x 1.2 inch ) Probe : 70 x 58 x 220 mm ( 2.8 x 2.3 x 8.7 inch ). Probe Cable Length Accessories Included @ Sensor probe head : 70 x 58 mm. 930 mm. Operation Manual... 1 PC Carrying case... 1 PC 4

5. FRONT PANEL DESCRIPTION Fig. 1 5-1 Display 5-2 Power button 5-3 Hold button 5-4 XYZ axis select button 5-5 Unit button 5-6 Range button 5-7 Battery compartment/cover 5-8 Stand 5-9 Probe input socket 5-10 Probe plug 5-11 Probe handle 5-12 Probe sensing head 5

6. MEASURING PROCEDURE 1)Power ON the meter by pushing the " Power button " ( 5-2, Fig. 1 ). 2)Select the desired unit ( micro Tesla or mili-gauss ) by pushing the " Unit button " ( 5-5, Fig. 1 ). 3)Use the " Range button " ( 5-6, Fig. 1 ) to select the suitable range. For the unknown EMF measurement, start with the highest range and keep decreasing until the higher resolution's reading is obtained. 4)Hold the " Probe handle " ( 5-11, Fig. 1 ), move the " Probe sensing head " ( 5-12, Fig. 1 ) slowly towards to the object under measurement until it is physically touched. 5)Use the " XYZ axis select button " ( 5-4, Fig. 1 ) to select the EMF value in the X, Y or Z axis. Note : @Due to the electromagnetic interference of the environment, the display reading may show small values before testing, for example less than 0.05 micro Tesla. This is not malfunction of the tester. @If the object under measurement is turned off during the measurement, the EMF tester reading should then return to zero, unless a field from other sources are detected. 6)During the measurement, if push the " Hold button " ( 5-3, Fig. 1 ) will freeze the display value. Push the " Hold button " again will release the Hold function. 6

7. RECOMMENDATION It is recommended to measure the presence of the electromagnetic field inside and outside of your home and business locations regularly. As "hot spots" are detected by the EMF tester, re-arrangement of the living and working areas is lightly recommended. Always try the best to avoid long term exposure to strong electromagnetic field. 8. BATTERY REPLACEMENT 1)When the left corner of LCD display show " ", it is necessary to replace the battery. However, in-spec. measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. 2)Slide the " Battery Cover " ( 5-7, Fig. 1 ) away from the instrument and remove the battery. 3)Replace with 9V battery ( Alkaline or Heavy duty type ) and reinstate the cover. 4)Make sure the battery cover is secured after changing the battery. 7 0412-EMF828