Technical Journal September 2012

Similar documents
Residual Current Circuit-breaker (RCCB) FH 200 Series

R.C.B.O. SP / 1 module

DSE201 Compact design with enhanced protection

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

QUALITY ASSURANCE & DOCUMENTATION

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

DS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)

18TH EDITION BS7671 HOW THIS AFFECTS YOU. BITESIZE II. wylexreasons.co.uk WHY CHOOSE ANYTHING LESS?

Domae. The right solution for distribution boards

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

New DX 3 High rating & breaking capacity

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

DX³ 4-pole RCBO 6000 A/10 ka

The effective choice The benefits of a product with the highest quality standards

Residual current devices

and other modular devices for low voltage installation

RESIDUAL CURRENT CIRCUIT BREAKER

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

COMPLETE SOLUTIONS FOR POWER PROTECTION

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

POWERSOURCEPURE INSTRUCTIONS. Pure Sine Wave Inverter. RINV1200P REINV1200P RINV2200P REINV2200P

Main catalogue. Distribution Innovation

Ultra Fast Earthing Switch UFES retrofit Overview

The young energy ensures more safety

Voltage limiting device HVL

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

P.1 CONTENTS. Industrial Earth Leakage Protection. Page

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

Maximum safety and easy installation

Technical catalogue. System pro M. Residual current devices 2CSC420001D0201

Voltage limiting device HVL

DX³ RCBO 6000A Phase + Neutral, neutral on left

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

Jaeshininformation Co., of Korea Distributor

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Overview Overvoltage protection

MCBs and RCDs LR TM 6000

Schneider Electric India As a global specialist in energy management with operations in more than 00 countries, Schneider Electric offers integrated s

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

LED control gear Compact fixed output

5. High voltage warning labels should be placed on all cabinet doors and terminal covers enclosing equipment operating at above 50 volts.

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

Power System Solutions (PSS)

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

Btdin RCBO 6000A up to 63A (2P)

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Miniature circuit breaker Application guide

New System pro M compact All that you need. 2CSC004011B0201

Protection and control P. 1 /2. Smart earth leakage protection

GENERAL. CONSTRUCTION External

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

Miniature Circuit-Breakers (MCBs)

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Presented to the IAPMO Standards Review Committee on December 9, 2013

DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection

Selective main circuit breakers S 750 series Technical Data

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

KD LV Motor Protection Relay

Effective discrimination of protective devices

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013.

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

l Suitable for most residential, commercial and light industrial applications

DX³ RCBO 6000A Phase + Neutral, neutral on right

Phase + Neutral, neutral on left side

Power systems Protection course

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

F200 - Ground Fault Equipment Protectors Complete protection of your equipment

Major changes within the New 18 th Edition Wiring Regulations announced by The IET

E.V.READY Specification for Installer Training Content

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Phase + Neutral, neutral on right side

FREQUENCY INVERTER INSTALLATION & USER GUIDE

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

cor Long Run Experience

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

AutoLink Frequently Asked Questions

(1,5 modules per pole)

Smart earth leakage protection

Delta Products VFD CP2000 Bypass Control Packages.

MINIATURE CIRCUIT BREAKER

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

LED Driver Linear / area fixed output

Variable Frequency Drive Basics

RX 3 M.C.B A up to 63 A

Transcription:

Technical Journal September 2012 Earth leakage protection in polluted low voltage network In present day irrespective of the application be it in process industry or in IT industry, Pollution of electrical network is on the rise. These electrical pollutions give rise to lot of problems in routine operations of the electrical products and system including safety devices which protects human against electrocution. The predominant contribution for network pollution is from wide use of electronic devices. Most of these electronic devices are nonlinear in nature which contributes harmonics into power networks. Some of the serious issues which have to be taken into consideration during electrical network design as well selection of protection devices. The consequences of this pollution are Nuisance tripping of protection devices Overloading of equipment due to harmonics Voltage and current distortions Increase in temperature cables and generators Poor reliability of electrical network. The most common non-linear loads are VFD s, Electronic ballast, Lift electronics and Computer equipment. The distortions might lead to malfunctioning of equipment and create an unsafe electrical distribution. We will analyze in this document the effect of distortions on earth leakage protection devices and counter measures to be taken to ensure safety of the people. According standards IEC 61008 and 61009, Type AC and A are clearly defined type Residual protection devices. The application is clearly defined in the standards.

Type AC residual protection devices are suitable for only alternating current system (AC system) Type A residual protection devices are suitable for alternating or pulsating current with DC component. Typical wave form is shown below. One more type of RCD is introduced by international standards under IEC 62423. It is categorized as Type B. Type B RCD s shall comply to IEC 62423 as well IEC 61008/61009. The standards clearly define the connected load parameters to these RCD s. The device is required to detect fault current up to 1000Hz. This type of RCD s are specifically designed for use in electrical network which are having current or voltage distortions. This avoids use of standard RCD s with higher current sensitivity in these networks (to protect against unwanted tripping) and ensures safety of people are not compromised.

The below curve indicates the distorted wave form due to 5 th harmonic. One need to take note that the Type B defined in Annex M of IEC 947 is different from Type B defined in IEC 62423. The earth leakage protection devices considered shall be based on electrical network conditions at site. When a network is polluted, the selection of RCD s shall be based on the following so that no unwanted tripping takes place. Environment which are polluted due to harmonics. Environments subjected to overvoltage due to lightning Fluorescent lamps with electronic ballasts can create unwanted tripping due to Permanent leakage currents value can be from 0,5 to 1mA for each device according to the lamp type. Switching peaks are caused when the devices are switching ON/OFF. These peaks can reach higher current during 10 s transitory. IT apparatus (computers or electronic devices) These devices generate permanent leakage currents of 50 Hz, of the order of 0,5-3,5 ma for each instrument. If this value reached 30% if sensitivity of standard RCD, any disturbance in the network leads to nuisance tripping

The RCD s which are used in these types of networks requires special design to overcome these surges without compromising the safety of the people. The devices are required to very special filtering circuits which ensures no unwanted tripping takes place at the same time protection is guaranteed. When RCD used with both over current and earth leakage protection, care needs to be taken in selecting RCD with short circuit withstand capacity. For example, in a distribution board, Miniature circuit breaker selected is with 10kA breaking capacity, then RCD s which are part of same distribution board shall also have same breaking capacity. In India, most of the cases MCB s used are of 10kA breaking capacity and accordingly breaking capacity required for RCD s are also has to be of 10kA only. Another important aspect which has to be taken into consideration is that selective type RCD should not considered when a device is connected closed to load where people are required to be protected. The following conditions are to be taken in to consideration before using Selective type devices. Upstream I n > 3 x downstream I n Upstream non-operating time t > downstream total time t. Selectivity can be achieved based on sensitivity current as well as use of selective type. The following charts gives overview of selectivity in residual current devices.

ABB offers complete range special type of RCD for this type application. These are APR type RCD s. The range is available from 30,100 and 300mA sensitivity. As a customer choice breaking capacity is available from 4.5kA (30mA), 6kA and 10kA. ABB is having complete range products which can provide perfect selectivity between upstream and downstream devices. The RCBO has a standard feature of trip indication for in the event residual current has initiated the trip. This gives the benefit to customer to know whether tripping is due to earth leakage of over current. These devices are perfectly suited for application in IT industries, Data centers, Industry where huge number of non-linear loads are present. Contact us for further information ABB Limited Design Institute 88/3, 88/6, Basavanahalli Village 562123, Bangalore North, Karnataka, INDIA email: Ramprasad.satyam@in.abb.com Technical Journal 09/12