Geberit Assisted Toilet Pre-Installation Instructions

Similar documents
Geberit Concealed cisterns

Clos-o-Mat Lima Lifter installation & user guide

7. Geberit Exposed Cisterns

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

cover plate Instructions for Use suitable for Viega Eco Plus universal shower WC element, model from 08/2015 en_int

Ropox Shower & Changing Bed

Systems for Wall-Hung Toilets, Pre-Wall, 2x6 Installation

Operating Instruction for Downlights

Sanitary systems. TECElux TECHNICAL GUIDELINES

HOSPITAL & PROFESSIONAL. Equipment

Universal flushing cisterns for front operation date of production since 09/2007, for large toilet operation panel: Model F 102, F 106, F 500, F 502

Electronic Bidet Seat

SECTION LAUNDRY WASHER-EXTRACTOR, 100 LB. (45.4 KG) CAPACITY

Instruction Manual. Sewage lifting station compli 300

Installation manual portable distributors

Electric Bathroom Accessories

LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS

Infrared Control Valve Installation Guide

Infrared Control Valve Installation Guide

Designed to touch. Geberit actuator plates for WC flush controls

Systems for Wall-Hung Toilets for Sigma 2x6 Installation

Urinal Flushing. Hydraulic Valve Infrared Control (IRC) Valve Direct Flush

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

Duo water control system

Operating instructions Flow monitors SI / / 2010

Chapter 6. Plumbing Elements and Facilities

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

Systems for Floor-Mounted, Back Outlet Toilets, 2x6 Installation

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

LED.Commercial 12W LED DD

Water, vibration and oil resistant LED work light, suitable for machine tools applications and high temperature water cleaning environments

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

Kitchen Tara Ultra. UNI SET Single-lever mixer Article number: Single-lever mixer Article number:

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

Designed to touch. Geberit actuator plates for WC flush controls

Mira Mode Shower and Bath Fittings

Operating Instructions

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features:

SY PVC / BS EN Control Flexible Cable

User Manual Rittal PMC UPS 6kVA

Installation Instructions 1662SG SG.223

San Remo. Uncluttered design. Ideal Standard S.A. Regions: Greece Mediterranean Middle East, Asia

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features:

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

BATHROOM EXTRACT FANS DECOR-100 Series

Installation manual wall-mounted distributor

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Installation Instructions 1662SG SG.222

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

COMFORT THROUGH ELECTRONICS

Installation Instructions 1662SG SG.224

ENGELS GROUP Shaping Inspiration NINETY YEARS. PRODUCT LIST lavanto 2017 / 2018

The Impact of the 18 th edition (BS 7671:2018)

Doodad Tape Light & Halcyon Controller Single Colour Installation Instructions

STAINLESS STEEL WASHROOM SOLUTIONS

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

STAINLESS STEEL WASHROOM SOLUTIONS

SAFETY EQUIPMENT VOLTAGE DETECTORS. PHE Voltage Detector Nominal voltages up to 30 kv / 50 Hz

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NEWS MARCH RRP excl. V.A.T.

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

F L B Metal Halide Light Generator for Fiber Optic Lighting Systems

Viega Flushing System Technology. List Price Book Volume

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

tapware bath set wall top assemblies washing machine stops basin set Also available with ceramic disc

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

Data sheet chainflex CF8821

LEAD ACID BATTERY CHARGER

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

CB14 CB14 XW CB14 Full Flush

10W LED Die Cast Small Rectangle Bulkhead Light

WC PANS, SQUAT PANS, URINALS & SHOWERS FRANKE WC PANS ARE DESIGNED TO REDUCE WATER CONSUMPTION BY UP TO

G SERIES - E TOUCH MIXER / TAP

METLAM PARTITION HARDWARE. Metlam Partition Hardware. > Washroom Hardware & Accessories

WC UNITS. WC units. 68 Products Ifö

28W WORK LAMP Model: CTL28 Part No:

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Bathroom Collection Vanity Units Vitreous China Basins Toilet Suites Mixer Taps

OPERATION & MAINTENANCE INSTRUCTIONS

X-JET (Counter current system)

Sanitary Ware Expert, Your best choice!

NEOZED D0 fuse-links gg 400/440VAC

Operating instructions

OPERATION & MAINTENANCE INSTRUCTIONS

Operating instructions Spray nozzle SDU

Medifab AU 1300 b NZ Page 1

Data sheet chainflex CF886

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

Planning and dimensioning of the drinking water system

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Is a good feeling to be sure and independent

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

GENERAL REQUIREMENTS FOR ACCESS


600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

Lighting series JLZ Lighting series JELZ

Transcription:

Geberit Assisted Toilet Pre-Installation Instructions Pre-Install Instructions Please see the below for instructions to prepare site for installation. All electrical connections are to be carried out by a qualified electrician. AC Power to be tested and available in advance of OpeMed engineers arrival. All flooring must be level and complete. All walls must be decorated and complete. Information: The factory setting for the seat height is 42.5 cm. If you wish to use this height, proceed to step B. If the customer wishes the seat height to be different from the factory setting, proceed to step A. 385 50 5 42 5 230 V ESD 3 Please note: 87 1 Cold water supply can be placed anywhere in the specified area. 56 28 28 9 Fused 2 Fuse Spur can be installed outside of the toilet however, distance is limited as there is only 700mm flex (see pages 3-5). Please always ensure the fuse is positioned above the water supply pipe. 140mm 40 6 40 3 If the soil / waste pipe is positioned through floor, ensure 140mm from centre of pipe to wall (see page 2). Waste pipe can be 90mm or 110mm. 1

Waste PIpe:- The Diagram below shows the positioning of the waste outlet. 1 Only for sideways soil connection: Outlet bend can also be fitted in a Left or Right position. ø 12 mm 20 10 10 2 4 Determine the height of the outlet pipe with the seat height: Select the appropriate dimension for Y depending on the set frame height. D (14 28) D = 14 15 16 17 18 19 20 21 X = 17 2 16 4 15 13 9 12 9 11 8 10 7 9 6 D = 22 23 24 25 26 27 28 X = 8 6 7 5 6 4 5 4 4 3 3 2 2 1 x 18 Y H Y 38 5 21 40 5 23 42 5 25 44 5 27 46 5 29 48 5 31 50 5 33 3 2

Electrical Connection:- The Geberit AquaClean requires a 230V AC 50Hz power supply. The power connection must be made in an area that is kept free from moisture or connected via a IPX4 waterproof socket with isolation switch be decorated and complete. The Diagram below shows the recommended positioning of the IP rated fuse. The electrical connection of Geberit AquaClean may only be installed by skilled persons in accordance with the local regulations. The following recommendations apply according to DIN VDE 0100-701:2008-10. The country-speciþc conditions for Austria and Switzerland are taken into account therein. Installation in rooms with bath tub or shower tray - The Geberit AquaClean models correspond to protection degree IPX4 and may only be installed outside of the edge of the tub or tray. 60 60 60 60 Protection area around the bath tub Protection area around the shower tray 1. Hidden connection IPX4 a) with unswitched b) with Þxed connection via junction box (at least IPX4, Geberit AquaClean may be closer than 60 cm to the edge of the tub or tray) 3

2. Visible connection Geberit AquaClean complete solution Geberit AquaClean enhancement solution Installation in rooms with showers without tray - The power outlet has to be installed outside the protection area. Protection area around the shower without tray (with Þxed fixed shower head) Protection area around the shower without tray (with ßexible flexible hose) ³ cm ³ cm Geberit AquaClean complete solution Geberit AquaClean enhancement solution 4

Geberit AquaClean in the protective area Approach: Construct a Þxed shower partition with a height of 225 cm between shower and WC system. This will mean that the WC system is outside the protective area. Non-conforming installation of the Geberit AquaClean models will then be possible. *In the case of shower partitions with heights less than 225 cm, the the minimum distance in in horizontal (encompassing radius) and vertical (thread measure) direction must be maintained. ³ ³ 225* a) Minimum distance, horizontal b) Minimum distance, vertical 5

Product data sheet Technical data Protection class Protection degree Nominal voltage Mains frequency Power consumption Power consumption standby / with heating switched on Cable length Flow pressure 1 Operating temperature Water temperature, adjustment range I IPX4 230 V AC 50-60 Hz 1000 W 1/9 W 0.7 m -10 bar 1 bar 10-40 C 10-39 C Water temperature, factory setting 37 C Dryer temperature, factory setting 45 C Flush volume, factory setting 6 and 3 l Spray time 2 Maximum load WC seat Scope of delivery 0.13 l/s 0 s 150 kg Water supply connection set with angle stop valve, reinforced braided hose and screw connection Spray shield Nozzle cleaner, 400 ml Cleaning set Connection set for WC, 9 0 mm Cover plate for remote control compartment Remote control with LC display, wall-mounted case and batteries, LR03 (AAA ) Fastening material Article Art. no. 185.200.11.1 Colour / Surface white alpine This product is supplied with the Geberit AquaClean nozzle cleaner and the Geberit Information, instructions and measures for handling hazardous substances safely can be found in the appendix or at www.geberit.co.uk. Accessories Accessory overview: Water supply and electrical connection for Geberit concealed cisterns 6