Geberit Assisted Toilet Pre-Installation Instructions Pre-Install Instructions Please see the below for instructions to prepare site for installation. All electrical connections are to be carried out by a qualified electrician. AC Power to be tested and available in advance of OpeMed engineers arrival. All flooring must be level and complete. All walls must be decorated and complete. Information: The factory setting for the seat height is 42.5 cm. If you wish to use this height, proceed to step B. If the customer wishes the seat height to be different from the factory setting, proceed to step A. 385 50 5 42 5 230 V ESD 3 Please note: 87 1 Cold water supply can be placed anywhere in the specified area. 56 28 28 9 Fused 2 Fuse Spur can be installed outside of the toilet however, distance is limited as there is only 700mm flex (see pages 3-5). Please always ensure the fuse is positioned above the water supply pipe. 140mm 40 6 40 3 If the soil / waste pipe is positioned through floor, ensure 140mm from centre of pipe to wall (see page 2). Waste pipe can be 90mm or 110mm. 1
Waste PIpe:- The Diagram below shows the positioning of the waste outlet. 1 Only for sideways soil connection: Outlet bend can also be fitted in a Left or Right position. ø 12 mm 20 10 10 2 4 Determine the height of the outlet pipe with the seat height: Select the appropriate dimension for Y depending on the set frame height. D (14 28) D = 14 15 16 17 18 19 20 21 X = 17 2 16 4 15 13 9 12 9 11 8 10 7 9 6 D = 22 23 24 25 26 27 28 X = 8 6 7 5 6 4 5 4 4 3 3 2 2 1 x 18 Y H Y 38 5 21 40 5 23 42 5 25 44 5 27 46 5 29 48 5 31 50 5 33 3 2
Electrical Connection:- The Geberit AquaClean requires a 230V AC 50Hz power supply. The power connection must be made in an area that is kept free from moisture or connected via a IPX4 waterproof socket with isolation switch be decorated and complete. The Diagram below shows the recommended positioning of the IP rated fuse. The electrical connection of Geberit AquaClean may only be installed by skilled persons in accordance with the local regulations. The following recommendations apply according to DIN VDE 0100-701:2008-10. The country-speciþc conditions for Austria and Switzerland are taken into account therein. Installation in rooms with bath tub or shower tray - The Geberit AquaClean models correspond to protection degree IPX4 and may only be installed outside of the edge of the tub or tray. 60 60 60 60 Protection area around the bath tub Protection area around the shower tray 1. Hidden connection IPX4 a) with unswitched b) with Þxed connection via junction box (at least IPX4, Geberit AquaClean may be closer than 60 cm to the edge of the tub or tray) 3
2. Visible connection Geberit AquaClean complete solution Geberit AquaClean enhancement solution Installation in rooms with showers without tray - The power outlet has to be installed outside the protection area. Protection area around the shower without tray (with Þxed fixed shower head) Protection area around the shower without tray (with ßexible flexible hose) ³ cm ³ cm Geberit AquaClean complete solution Geberit AquaClean enhancement solution 4
Geberit AquaClean in the protective area Approach: Construct a Þxed shower partition with a height of 225 cm between shower and WC system. This will mean that the WC system is outside the protective area. Non-conforming installation of the Geberit AquaClean models will then be possible. *In the case of shower partitions with heights less than 225 cm, the the minimum distance in in horizontal (encompassing radius) and vertical (thread measure) direction must be maintained. ³ ³ 225* a) Minimum distance, horizontal b) Minimum distance, vertical 5
Product data sheet Technical data Protection class Protection degree Nominal voltage Mains frequency Power consumption Power consumption standby / with heating switched on Cable length Flow pressure 1 Operating temperature Water temperature, adjustment range I IPX4 230 V AC 50-60 Hz 1000 W 1/9 W 0.7 m -10 bar 1 bar 10-40 C 10-39 C Water temperature, factory setting 37 C Dryer temperature, factory setting 45 C Flush volume, factory setting 6 and 3 l Spray time 2 Maximum load WC seat Scope of delivery 0.13 l/s 0 s 150 kg Water supply connection set with angle stop valve, reinforced braided hose and screw connection Spray shield Nozzle cleaner, 400 ml Cleaning set Connection set for WC, 9 0 mm Cover plate for remote control compartment Remote control with LC display, wall-mounted case and batteries, LR03 (AAA ) Fastening material Article Art. no. 185.200.11.1 Colour / Surface white alpine This product is supplied with the Geberit AquaClean nozzle cleaner and the Geberit Information, instructions and measures for handling hazardous substances safely can be found in the appendix or at www.geberit.co.uk. Accessories Accessory overview: Water supply and electrical connection for Geberit concealed cisterns 6