Fan Performance Curves - FDCLP2 with ECM Unit Size 1 1 2 3 4 5 6 7 8 9 1 11 Unit Size 2 1 2 3 4 5 6 7 8 9 1 11 12 No Coil 1 Row 2 Row FDCLP2 Fan Curves-1 v1
Fan Performance Curves - FDCLP2 with ECM Unit Size 3 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 Unit Size 5 2 4 6 8 1 12 14 16 18 2 22 No Coil 1 Row 2 Row FDCLP2 Fan Curves-2 v1
Fan Performance Curves - FDCLP2 & Sensible Cooling Coil (DOAS) with ECM Unit Size 1-2 Row Cooling Coil 1 2 3 4 5 6 7 8 9 1 11 Unit Size 2-2 Row Cooling Coil 1 2 3 4 5 6 7 8 9 1 11 12 Max 1 Row RH Coil 2 Row RH Coil FDCLP2 Fan Curves-3 v1
Fan Performance Curves - FDCLP2 & Sensible Cooling Coil (DOAS) with ECM Unit Size 3-2 Row Cooling Coil 1 2 3 4 5 6 7 8 9 1 11 12 13 14 Unit Size 4-2 Row Cooling Coil 2 4 6 8 1 12 14 16 18 2 Max 1 Row RH Coil 2 Row RH Coil FDCLP2 Fan Curves-4 v1
Fan Performance Curves - FDCLP2 & Sensible Cooling Coil (DOAS) with ECM Unit Size 5-2 Row Cooling Coil 2 4 6 8 1 12 14 16 18 2 22 Max 1 Row RH Coil 2 Row RH Coil FDCLP2 Fan Curves-5 v1
Fan Performance Curves - FDCLP2 with PSC Unit Size 2 2 4 6 8 1 12 Unit Size 3 2 4 6 8 1 12 No Coil 1 Row 2 Row Min FDCLP2 Fan Curves-6 v1
Fan Performance Curves - FDCLP2 with PSC Unit Size 5 5 1 15 2 25 No Coil 1 Row 2 Row Min FDCLP2 Fan Curves-7 v1
FDCLP2, PSC Capacities Unit Size 2 3 5 FDCLP2, ECM Capacities Unit Size 1 2 3 5 Inlet Size Primary Airflow Fan Airflow Full Load Amps Motor HP Minimum Maximum Minimum Maximum 115V 28V 24V 277V 6 3 55 8 56 1 45 1 1/5 3.9 1.5 1.5 1.4 1 94 1 6 3 55 8 56 175 45 175 1/4 4.2 1.6 1.7 1.6 1 94 175 1 94 18 14x8 31 19 825 1925 2 x 1/5 8.8 3.2 3.3 3. Inlet Size Primary Airflow Fan Airflow Full Load Amps Motor HP Minimum Maximum Minimum* Maximum 115V 28V 24V 277V 4 45 4 5 6 5 6 65 55 1 1 1/3 4.4 3.6 3.1 2.9 7 95 8 6 65 55 8 125 175 1 11 1/3 4.3 2.7 2.5 2.4 1 21 175 6 65 55 8 125 11 1 135 1/2 7.3 5.1 4.2 4 1 21 135 1 21 18 14x8 295 19 2 25 2 x 1/3 7.8 5.4 4.5 4.2 FDCLP2 with Sensible Cooling Coil (DOAS), ECM Capacities Unit Size Inlet Size Primary Airflow Fan Airflow Full Load Amps Motor HP Minimum Maximum Minimum* Maximum 115V 28V 24V 277V 4 45 4 1 5 6 5 6 65 55 1 1 1/3 5.6 3.6 3. 2.7 7 95 8 4 45 4 5 6 5 2 6 65 55 1 11 1/3 4.6 2.8 2.6 2.4 7 95 8 8 125 11 4 45 4 5 6 5 3 6 65 55 1 135 1/2 7.7 4.4 4.4 4. 7 95 8 8 125 11 4 45 4 5 6 5 4 6 65 55 7 95 8 2 1775 1/2 6.2 4.7 3.5 3.3 8 125 11 1 21 1775 4 45 4 5 6 5 5 6 65 55 8 95 11 2 1925 2 x 1/3 7.8 5.8 4.5 4.3 1 125 18 14x8 295 19 *Minimum flow with High-Turndown Flow motor program Notes: 1. Minimum primary airflow limit based on digital controls and a min.2 in. w.g. [5Pa] differential pressure signal from airflow sensor. 2. Maximum primary airflow limit based on max 1.5 in. w.g. [375 Pa] differential pressure signal from airflow sensor. 3. Minimum fan flow with High-turndown Flow motor program (ECM only). FDCLP2 Fan Curves-8 v1
FDCLP2 - Electric Coil Max kw Size 1 Phase Voltage 3 Phase Voltage 12 28 24 277 48 28 48 6 1** 4.7 7.5 7. 7. 6.5* 7.5 7. 7.5 2 4.9 8.5 8.5 8.5 6.5* 9. 8.5 9. 3 4.9 8.5 8.5 8.5 6.5* 9. 8.5 9. 5 5.1 8. 9. 1. 17 14. 17. 22. *Available up to 2 stage only **EC Motor Only FDCLP2 DOAS - Electric Coil Max kw Size 1 Phase Voltage 3 Phase Voltage 12 28 24 277 48 28 48 6 1 4.9 9. 8.5 8.5 6.5* 9. 8.5 9. 2 4.9 9. 8.5 8.5 6.5* 9. 8.5 9. 3 4.9 8.5 8.5 8.5 6.5* 9. 8.5 9. 4 4.7 8.5 9.5 1. 1 14. 17. 18. 5 4.5 8. 9. 1. 17 14. 17. 22. *Available up to 2 stage only FDCLP2 Fan Curves-9 v1